DEVIL QUARTZ HALOGEN HEATER
MODEL NO: DEVIL 370SPD
PART NO: 6920259
OPERATING & MAINTENANCE
INSTRUCTIONS
ORIGINAL INSTRUCTIONS GC08/22
Page 2
Thank you for purchasing this CLARKE Quartz Halogen Infra-red Heater.
Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.

SPECIFICATIONS

Model Number Devil 370SPD
Part Number 6920259
Weight 13.8 kg
Dimensions (LxWxH) mm 630 x 610 x 810
Rated Input Wattage 2.8 kW (2 x 1.4kW)
Rated Input Amperage 12.17 A
Supply Voltage 230V - 50Hz
Fuse Rating 13 A
Ingress Protection Class IP20
Duty cycle Continuous

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not effect your statutory rights.
2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 3
THE FOLLOWING TABLE ADDRESSES THE INFORMATION REQUIREMENTS OF REG.2015/1188
Item Symbol Value Unit
Heat output
Measured seasonal space heating energy efficiency 35%
Nominal heat output P
Minimum heat output (indicative) P
Maximum continuous heat output P
nom
min
max
Auxiliary electricity consumption
At nominal heat output el
At minimum heat output el
In standby mode el
max
min
SB
Type of heat input for electric storage local heaters only
Manual heat charge control with integrated thermostat No
Manual heat charge control with room and/or outdoor temperature feedback No
Electronic heat charge control with room and/or outdoor temperature feedback
Fan assisted output No
Type of heat output/room temperature control (select one)
Single stage heat output, no temperature control No
With mechanical thermostat temp control No
With electronic temperature control Yes
Electronic temperature control with day timer No
Electronic temperature control with week timer No
Other control options (multiple selections possible)
Room temperature control with presence detection No
Room temperature control with open window detection Yes
Room temperature control with distance control option No
Room temperature control with adaptive start control No
Room temperature control with working time limitation Yes
Room temperature control with black bulb sensor Yes
2.8 kW
1.4 kW
2.8 kW
n/a kW
n/a kW
0.001kw kW
No
3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 4

GENERAL SAFETY RULES

1. These heaters are for INDOOR USE ONLY.
2. DO NOT expose the heater or power cable to rain or wet conditions. Any water entering the heater will increase the risk of electric shock. DO NOT use this heater in a bathroom, shower room or any other wet environment.
3. NEVER locate the heater near combustible materials such as curtains, furniture etc. Allow at least 1 metre distance.
4. DO NOT locate the heater close to an adjacent wall or low ceiling. Allow a distance of at least 1 metre from a wall or ceiling. Avoid placing the heater directly below power socket outlets.
5. Take care to ensure that the wire guard cannot be covered.
6. DO NOT operate heater in explosive atmospheres such as in the presence of flammable liquids, gases or dust such as in a paint spray booth or any explosive environment.
7. NEVER stand the heater on a movable vehicle where it could tip over.
8. DO NOT allow the halogen tubes to become covered with dust which could become a fire hazard. If used in a dusty workplace the heater should be cleaned as described under Cleaning and Maintenance.
9. NEVER touch the halogen tubes for at least 15 minutes after switching off.
10. DO NOT leave the heater unattended.
11. If children are present always use with a fireguard.
12. Store the heater out of the reach of children and do not allow persons unfamiliar with these instructions to operate it.
13. ALWAYS manoeuvre the heater using the handles provided and avoid trapping the fingers between the handle and the heater body.
14. NEVER leave the heater unattended while in use. Turn off at night if unattended.
ELECTRICAL SAFETY
1. Electrical appliances must match the power outlet. Never modify the plug in any way. DO NOT use adaptor plugs with earthed (grounded) appliances. Correct plugs and outlets will reduce the risk of electric shock.
2. DO NOT use this product with an extension cable.
3. DO NOT abuse the electrical cable. Never use the cable for pulling or unplugging the heater. Keep the cable away from sources of heat, oil,
4
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 5
sharp edges or moving parts. Damaged or tangled cables increase the risk of electric shock.
4. Keep the power cable well away from machines and ensure an adequate electrical supply is close at hand so that the operation is not restricted by the length of the cable.
5. ALWAYS disconnect from the power supply before moving the heater or performing any cleaning or maintenance tasks.
6. Inspect the power cable regularly for signs of damage. DO NOT use if it is damaged, and ALWAYS keep it away from the source of heat.
7. Check the heater for damage before use. DO NOT use if the heater tubes are damaged or broken. Any damage should be properly repaired or the part replaced. If in doubt, DO NOT use. Consult your local CLARKE dealer.
SERVICE & REPAIRS
1. If necessary, have your heater repaired by a qualified person using identical replacement parts. This will ensure that the safety of the product is maintained.
Please keep these instructions in a safe place for future reference.

ENVIRONMENTAL RECYCLING POLICY

Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the
treatment, recycling & recovery and environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with
general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
This product contains valuable raw materials. Metal products should be takento your local civic amenity site for recycling of metal products. Recycle unwanted materials instead of disposing of them as waste. All unwanted accessories and packaging should be sorted and taken to a recycling centre for disposal in a manner which is compatible with the environment.
5
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 6

ELECTRICAL CONNECTIONS

Plug must be BS1363/A approved.
Always fit
Ensure that the outer sheath of
Neutral
(Blue)
Live
(Brown)
Earth
(Green and
a 13 Amp
the cable is firmly held by the clamp
fuse.
Yel low)
WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE POWER SUPPLY.
These 230v heaters are provided with a 13 amp BS 1363 plug, fitted with a 13 amp fuse and MUST be connected to a standard, 230 Volt (50Hz) electrical supply, preferably through a suitably fused isolator switch.
If the plug has to be changed because it is not suitable for your socket or because of damage, it must be removed and a replacement fitted, following the wiring instructions shown below. The old plug must be discarded safely as
insertion into a power socket could cause an electrical hazard.
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH.
The wires in the mains lead should be wired up in accordance with the following colour code:
• Connect the GREEN & YELLOW wire to the plug terminal marked with a letter E or
• Connect the BROWN wire to the plug terminal marked a letter “L”.
• Connect the BLUE wire to the plug terminal marked a letter “N”.
The fuse in the plug must be replaced with one of the same rating and this replacement must be ASTA approved to BS1362.
We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD).
If in any doubt, consult a qualified electrician. DO NOT attempt any electrical repairs yourself.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
6
Page 7

UNPACKING AND ASSEMBLY

UNPACKING

When unpacking, please check contents against the following list and advise your dealer immediately if any parts are missing.
1 x Heater
1 x Lower base frame
2 x Handles
3 x Castors (one with brake)
1 x Fixings pack including knobs and spacers
1 x Remote control unit

ASSEMBLY

1. Bolt the handles to the lower frame using the two loose bolts & locknuts noting the orientation of the handles.
2. Lay the heater face down and attach the complete frame to the heater body using the securing knobs and the spacers located either side of the frame tubing.
7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 8

OPERATION

WARNING: FOR SAFE OPERATION OF THIS HEATER IT IS ESSENTIAL TO READ THESE INSTRUCTIONS BEFORE USE.
WARNING: PLEASE NOTE THAT THE HEATING ELEMENTS OF THIS PRODUCT DO NOT GLOW WHILST IN OPERATION. ANY PICTURES SHOWING THIS IN ADVERTISING MATERIAL ARE FOR ILLUSTRATION ONLY.

USING THE REMOTE CONTROL

All operations must be done using the remote control.
• 2 x AAA batteries are required
and are installed as shown by the diagram found inside the control unit.
• The remote control must be
directed at the heater display panel. It has a range of approx
2.5 metres and must be aimed at the correct angle.
• The function of each button on
remote control is the same as operation panel.

MANUAL OPERATION

1. Stand the heater on a firm, level surface and following all safety precautions, connect to a suitable power supply.
• The heater is equipped with an anti-tilt switch that automatically
cuts the power off should the heater tip over. If this happens, stand the heater upright and it will immediately re-set.
2. Switch on the power at the primary switch on the side of the heater.
• The heater will be in Standby
with the display showing PO.
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 9
3. Press to turn on the upper heating lamp and the screen will show P1.
4. Press to select the mode from P1-P6, referring to the different temperature settings.
P1 Only the upper element is working
P2
P3
P4
P5
P6 Both elements are working
24
26
28
30
o
o
o
o
• During mode P2-P5 the upper element is working all the time and the
lower element will be turned off automatically according to the set temperature.
5. The user can change from mode
P1 and P6 by pressing . The screen will show a cascade effect when in mode P6.
6. To power off the unit, press again, the heater stops working, and returns to standby with the screen showing ‘PO’.
7. Then switch off the main switch and unplug the heater.
9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 10

SETTING THE SHUTDOWN TIMER

1. Press to set the shutdown timer. The time on the screen flickers with initial status 00:00.
2. Press and to set the time to turn the heater off.
• It increases/decreases 1 hour per press.
3. Press when you finish setting and the heater will be in the countdown mode.
• It will shut down 2 hours later.
4. When the time is up, the heater turns off automatically and enters the standby state P0.

FUNCTION FOR DETECTING OPENING WINDOWS

1. When the ambient temperature drops over 5oC within 10 minutes, the heater will turn off automatically and enter a standby state with three alarm beeps.
• Users need to turn on the heater manually by pressing-
10
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 11

CLEANING & MAINTENANCE

If the heater has been used, always allow it to cool down for at least 15 minutes and disconnect from the mains supply before performing any maintenance tasks.

FITTING/ REPLACING LAMPS

Before attempting to fit/replace halogen tubes, ensure the heater is switched off and disconnected from the electrical supply.
NEVER handle the heater tubes with bare hands. ALWAYS handle using either a soft clean glove or a piece of soft clean cloth wrapped around the tube.
1. Remove the two screws and remove the guard.
2. To remove the tube, grasp it and gently but firmly push it to one end of the heater. The tube holders are spring loaded and will allow the tube sufficient movement to clear the opposite holder.
3. Remove the tube and dispose of, according to local regulations.
4. Fit the new halogen tubes in reverse order.
5. Replace the guard using the screws removed earlier.
The heater is now ready for use.

PERIODICALLY

1. If there is any substantial build up of dirt, wipe the heater body with a damp cloth. Take care that no moisture enters the heater. Take care NOT to touch the tubes with your fingers.
2. Inspect the power cable for damage. Undue heat will cause the cable to stiffen and crack. If this is found, have the cable replaced. Check cable routing and ensure it is well away from the heat source.
3. Ensure heating tubes are clear of dust (use compressed air to clean if possible. (ALWAYS wear a dust mask if performing this operation)
4. Refer to your CLARKE dealer if internal repairs are required.
5. When storing the heater, allow it to cool down, then place it in its packing box for storage in a dry, ventilated place.
11
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 12

FAULT FIN DIN G

SYMPTOM PROBLEM SOLUTION
Heater does not operate, although plugged in and switched on.
Heater tube is glowing hot.
Heater does not respond to remote controller.
Plug is loose/bad connection.
Fuse blown. Replace if necessary and
No power at socket outlet.
Tilt safety switch is disabling unit.
Input voltage incorrect. Ensure power supply
Air supply obstructed. Ensure the heater is kept
Batteries defective. Replace batteries.
Controller is out of range or not pointing at the receiver.
Remove the plug & check the connection of the plug and socket.
investigate the cause. If fuse blows repeatedly, consult your CLARKE dealer.
Insert plug into a suitable socket.
Ensure unit is upright. If switch does not re-set, consult your CLARKE dealer.
matches the rating on the label.
away from any objects or materials which could obstruct the flow of air.
Move closer or try different angles of pointing the controller at the heater.
Controller damaged internally
12
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Consult your CLARKE dealer.
Page 13

COMPONENT PARTS

No Description No Description
1 Castor (standard) 10 Securing knob
2 Castor with brake 11 Control panel assembly (not
shown)
3 Ceramic end cap 12 PCB control unit (not shown)
4 Quartz halogen tube 13 Bolt/locknut
5 Wire guard 14 ON/OFF switch (power)
6 Power cable 15 ON/OFF switches (lamps)
7 Rear Handle (not shown) 16 Tilt safety switch (not shown)
8 Side frame/handle 17 Lower frame
9 Plastic spacers 18 Remote control unit
13
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 14

DECLARATION OF CONFORMITY-UK

14
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 15

DECLARATION OF CONFORMITY-CE

15
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 16
Loading...