Clarke DAF 1, 4500155 User guide

Page 1
DIGITAL ANGLE FINDER
MODEL: DAF-1
Part No: 4500155
OPERATING MANUAL
11/08
Page 2
INTRODUCTION
Thank you for purchasing this CLARKE product
GUARANTEE
This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not effect your statutory rights.
ENVIRONMENTAL PROTECTION
Do not dispose of this product with general household waste. All tools, acessories and packaging should be sorted, taken to a re-cycling centre and disposed of appropriately.
SPECIFICATION
metI noitacificepS
egnargnirusaeM)sgnittes-4(seerged063-0
ecnarelotgnirusaem/ycaruccAeerged1.0
htgnelmrAmm502
yal
psiDDCLthgiehretcarahcmm21
thgieW smarg054
)wxhxl(snoisnemiD32x05xx562
tnemeriuqeRyrettaByrettabmuihtiL2302r
2
CV3
Page 3
DIGITAL ANGLE FINDER
The DAF-1 is an inovative Angle Finder with LCD display. It can be used for measuring, marking and setting angles with the following features:
• Absolute and relative measurement display
• Easy calibration & zero setting
• Lockable blade at any angle through 360 degrees
• Level bubble located on top
• Aluminium body & stainless steel arm
• 2000 hours Lithium battery life
Moving blade
Fixed blade/body
LCD display
Locking knob
Spirit Level on top
Please note that the details and specifications contained herein are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice.
3
Page 4
OPERATING INSTRUCTIONS
PUSH BUTTONS & LCD
Analogue quadrant indicated
High resolution 0.05
“ABS” mode
Conversion between absolute measurement and relative measure­ment by short press
Holding
Press more than 8 seconds to turn off, short press to shut off LCD
ABS SETTING
In ABS mode the device will;
automatically record the original ZERO position after powering off
display always reads upright
In ABS mode, a long press on the ZERO/ABS button for 5 seconds will set the ZERO position of the movable blade.
Position the moving blade in the same plane as the fixed blade.
4
Page 5
USE OF THE SPIRIT LEVEL
Standard level surfce
USE OF THE ANALOGUE QUADRANT/MOVING BLADE
Plumb surface for measuring
5
Page 6
DIGITAL READOUTS
Both internal and external angles can be measured, the reading displayed as a positive or negative angle.
6
Page 7
LOCKING POSITIONS FOR A SPECIFIC MEASURING RANGE
A different measuring angle can be chosen by locking the arm at one of four different locking holes. With the arm locked precisely in position,the workpiece can be marked out accurately.
REPLACING THE BATTERY
Press and twist with the thumb/fingrer tips to loosen the battery cover and remove the cover.
Replace the old battery with a new one. A single CR2032 (3volt) button cell is required.
Put the battery cover back on and twist to secure.
GENERAL CARE OF THIS PRODUCT
If dirty, always clean the angle finder with mild liquid soap and a damp cloth. never immerse the unit in water.
7