MODEL NO: CPPPSS
PART NO:
PART NO: 6499635
CHEMICAL PLUNGER PUMP
INTRODUCTION
Thank you for purchasing this CLARKE chemical plunger pump,
Suitable for water, alcohol, petroleum, diesel, paraffin, lubricant, NOT SUITABLE for water-based chemicals, acid or
alkaline.
Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully.
LIST OF CONTENTS
•1 x Pump •1 x Outlet tube
• 1 x Handle assembly • 1 x Extension Inlet tube
• 2 x Nuts and Bolts • 1 x 2 piece telescopic extension with filter
ASSEMBLY
FITTING THE OUTLET TUBE
1. Remove the nut from the pump as shown. 2. Place the nut over the outlet tube and back
onto the pump
FITTING THE HANDLE ASSEMBLY
FITTING THE TELESCOPIC EXTENSION TUBE
1. Connect the handle as shown and secure at
each point using the small nuts and bolts.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
1. Fit the telescopic extension with filter together
as shown

FITTING THE PUMP TO A BARREL
1. Fit the telescopic extension with filter to the pump.
• You can fit the extension inlet tube in between if
required.
2. Adjust the telescopic extension tube to the required length.
• The bottom of the telescopic extension should be just off
of the bottom of the barrel when fitted.
3. Screw the pump into the threaded opening of the barrel.
USING THE PUMP
1. Place a suitable container under the outlet tube.
2. Pump the handle to draw fluid from the barrel.
• The first time you use the pump, you may need to pump
the handle a few times to prime the pump.
• Each ‘pump’ of the handle will draw approximately 0.38L
of fluid.
SPECIFICATIONS
Container Adaptor Size 2" BSP
Max Flow 0.38 litres per stroke
Inlet Tube Length 300 mm
Inlet Tube Diameter 21.5mm
Outlet Tube Diameter 16.7mm
Min-Max Height (with extension tube fitted) 1080 - 1360 mm
Maximum Drum Size 205 litres
Dims (WDH) 485 x 90 x 1360 mm (fully extended)
Product Weight 0.8 kg
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12 months from the date of
purchase. Please keep your receipt which will be required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not
used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior
permission.
This guarantee does not effect your statutory rights.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

CHEMICAL RESISTANCE TABLE
• Room Temperature
•% Say Mass Concentration
WATER ACIDS ALKALI PETROLEUM
BASED
Sea Water Acetic Acid
20%
Boric Acid
10%
Citric Acid
10%
Hydrochloric
Acid 35%
Lactic Acid
80%
Nitric Acid
10%
Oxalic Acid
50%
Phosphoric
Acid 50%
Potassium
Hydroxide
25%
Sodium
Hydroxide
solution 50%
Silicone Oil Calcium
HALOGENS ALCOHOL THINNER
Ethanol 96% Acetone
Chloride 10%
Copper
Sulphate
Potassium
Dichromate
10%
Soap Solution Methanol
Sodium
Chloride 10%
Sodium
Nitrate 10%
Sodium
Thiosulphate
Zinc Chloride
10%
Glycerine
Isopropanol
Propanol
Sulphuric
Acid 70%
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com