Thank you for purchasing this CLARKE Portable Air Conditioner.
Before attempting to operate the machine, it is essential that you read this
manual thoroughly and carefully follow all instructions given. In doing so you
will ensure the safety of yourself and that of others around you, and you can
also look forward to the product giving you long and satisfactory service.
GUARANTEE
This CLARKE product is guaranteed against faulty manufacture for a period of
12 months from the date of purchase. Please keep your receipt as proof of
purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product can
be returned to us without prior permission.
This guarantee does not affect your statutory rights.
ENVIRONMENTAL PROTECTION
Recycle unwanted materials instead of disposing of them as
waste. All unwanted accessories and packaging should be sorted
and taken to a recycling centre for disposal in a manner which is
compatible with the environment.
R410A is a refrigerant that complies with EEC environmental
standards. Nonetheless, the refrigerant circuit on the machine
should never be punctured. At the end of its working life, consign
the air conditioning unit to a special collection centre.
Through purchase of this product, the customer is taking on the obligation to
deal with the WEEE in accordance with the WEEE regulations in relation to the
treatment, recycling & recovery and environmentally sound disposal of the
WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 3
SAFETY WARNINGS
WARNING: IF THE SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY
THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED
PERSONS IN ORDER TO AVOID A HAZARD.
1. Please read these instructions carefully and retain for future reference.
2. Position the power cable so that it cannot be inadvertently pulled or
pinched, and where it does not cause a trip hazard.
3. This appliance is designed for use in residential environments and must not
be used for other purposes.
4. If the appliance requires repair, always contact your CLARKE dealer.
Always insist on original spare parts. Repairs carried out by unauthorized
persons may be dangerous and invalidate the guarantee.
5. This appliance must only be used by adults. Children should not be allowed
to play with this appliance.
6. Do not use extension power cables.
7. Before cleaning or maintenance operations, always unplug the appliance
from the power supply.
8. Do not move the appliance by pulling the power cable.
9. Do not install the appliance close to sources of gas, oil or sulphur. Do not
install near sources of heat.
10. Do not use the appliance on inclined surfaces.
11. Always keep the appliance at least 50 cm away from walls or furniture.
12. Keep the appliance at least 50 cm away from flammable substances
(solvents etc) or pressurised containers (e.g. aerosol cans).
13. Do not rest heavy or hot objects on top of the appliance.
14. Do not use the appliance outdoors.
15. Do not obstruct or restrict the airflow to the inlet or from the air outlet.
3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 4
ELECTRICAL CONNECTIONS
Plug must be BS1363/A approved.
Always fit a 13 Amp fuse.
Ensure that the outer sheath of the cable is firmly held by the clamp
Neutral
(Blue)
Live
(Brown)
Earth
(Green and Yellow)
WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE
MAINS SUPPLY.
Before switching the product on, make sure that the voltage of your electricity supply is
the same as that indicated on the rating plate. This product is designed to operate on
230 V AC 50Hz. Connecting it to any other power source may cause damage.
This product may be fitted with a non-rewireable plug. If it is necessary to change the
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or
damaged, the plug must not be used until a suitable replacement is obtained.
If the plug has to be changed because it is not suitable for your socket, or due to
damage, it should be cut off and a replacement fitted, following the wiring instructions
shown below. The old plug must be disposed of safely, as insertion into a mains socket
could cause an electrical hazard
WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT
ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
Blue = Neutral Brown = Live Yellow and Green = Earth
If the colours of the wires in the power cable of this product do not correspond with the
markings on the terminals of your plug, proceed as follows.
• The wire which is coloured Blue must be connected to the terminal which is
marked N or coloured Black.
• The wire which is coloured Brown must be connected to the terminal which
is marked L or coloured Red.
• The wire which is coloured Yellow and Green must be connected to the
terminal which is marked E or or coloured Green.
.
.
We strongly recommend that this machine is connected to the mains supply via a Residual
Current Device (RCD)
If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
4
Page 5
OVERVIEW
1
3
2
4
6
8
5
7
9
NO DESCRIPTIONNODESCRIPTION
1Air Outlet Flap 6Lower Air Filter Frame
2Control Panel 7Power Cable with storage
3Handle 8Water Drain Port
4Upper Air Filter Frame (Air Intake) 9Power Plug Storage Socket
5Air Outlet Port
5
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 6
CONTENTS
Ensure the air conditioner and its components suffered no damage during
transit and that all components are present. Should any loss or damage be
apparent, please contact your CLARKE dealer immediately.
The following components are supplied with the unit;
1. Flexible exhaust duct.
2. Adjustable window slider plate.
3. Remote control unit.
INSTALLATION
IMPORTANT: Do not position your air conditioner where it will be exposed to
sources of heat above 40
1. Always transport the air conditioner upright or resting on one side.
Remember to drain the tank before moving the appliance.
• It is recommended to wait up to 24 hours after transporting the air
conditioner before using it, to allow the refrigerant gasses to settle.
2. Position the unit on a level, dry
surface with at least 50 cm of free
air space around the unit.
NOTE: Do not use the air exhaust
duct when in DRY or FAN
only modes.
3. Fit the flexible exhaust duct by
pushing some of the ducting ribs
past the locking channels and
then keep twisting the whole
ducting anti-clockwise until the ducting tightens in the outlet port.
4. Fit the window exhaust adaptor to the other end of the duct.
5. Move the air conditioner into position, and extend the flexible exhaust duct
to suit your window layout.
6. Pass the discharge end out of the nearest window.
NOTE: The length of the exhaust duct is variable between 480 mm and
1500 mm (adaptors included). Using a shorter length of ducting
uses less energy.
o
C.
6
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 7
NOTE: The length of duct has been designed to suit the specification of
the air conditioner. Do not use an extension or change to a
different size duct as it may lead to poor performance.
7. The flexible exhaust ducting can
be bent to an angle if followed by
a straight section, but tight curves
and kinks must always be
avoided.
7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 8
8. The window slider plate is
designed to fit most standard
vertical sash type and horizontal
sliding windows. However, it may
be necessary for you to adapt the
installation procedure for various
other types of window.
9. Extend the two parts of the
window slider and fit into the
window opening, below or beside
the window panel. Secure in
position by closing the window, or if not secure, wedge or otherwise secure
the window slider plate so that it cannot fall out.
10. Fit two AAA size batteries to the
remote control unit by sliding the
battery cover away and installing
the batteries to face in opposing
directions as indicated by the
symbols inside the unit.
• Follow the polarity diagram inside
the battery compartment.
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 9
CONTROL PANEL
The control panel has the following buttons:
1. POWER: Press this button to turn the unit on & off. When turned on, the
machine will start running in the previously selected mode.
• If the ambient temperature is above 35
enter standby mode.
o
• If it is below 5
C it will indicate “L” and the unit will enter standby mode.
2. TIMER: Press this to select the timer mode and the main display will initially
show “0”. Set the running time from 0-24 hours using the UP/DOWN buttons.
3. MODE: Press this button to select from COOLING, FAN, DRYING or ENERGY
SAVER modes.
4. UP/DOWN: Press the UP or DOWN buttons to set the required temperature
or adjust the running time in the TIMER mode.
• Press these buttons simultaneously to switch from Celsius to Fahrenheit
display.
5. FAN: Press this button to select Low, Medium or High (F1-F3) fan speed. If
switching between cooling and fan mode, the fan speed remains the
same. During dehumidifying, the fan will run at low speed. "In fan mode,
press this button for 5s, the up motor and down motor will start
simultaneously. This function is to dry the water on the evaporator, to avoid
the damp and mildew."
o
C, the display will indicate “H” and
9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 10
REMOTE CONTROL
The remote control can be stored in the holder provided at the top of the air
conditioning unit as shown. It requires 2 x AAA batteries to be installed as
shown on page 8.
The remote control incorporates the following pushbuttons:
POWERTurns the unit on or off.
TIMERSets the timer On/Off and allows the running time
duration to be adjusted using the Up/Down arrows.
SWINGSets the air outlet cover to open and close. The
cover automatically closes when the unit is
switched off to prevent the ingress of dust.
oC/o
F
MODESelects either: COOLING mode
UP or DOWN (arrows)Sets the target temperature or adjusts the run time
FAN
Switches the display between degrees Celsius to
degrees Fahrenheit.
DRYING mode
FAN mode
duration in TIMER mode
.
"Selects the fan speed to HIGH(F3), MID(F2) or
LOW(F1).
10
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 11
OPERATION
GENERAL OPERATION
If the room is exposed to direct sunlight, draw any curtains during the sunniest
part of the day.
NOTE: Always drain any remaining water from the unit via the drain plug
after operating in DRY mode. The unit will automatically stop
working when water reaches the high level.
NOTE: Do not use the air exhaust duct when in DRY or FAN modes.
SETTING THE TIMER
1. Press TIMER button once, the "TIMER" on the LED display and the double 8
area will be light and flashing, then press UP or DOWN button to adjust the
set time.
2. This function can work whether the machine in on or off, and when the set
time has elapsed, the unit will switch off or switch on automatically.
3. When the timer is set, press TIMER button once to show the remaining time;
and press TIMER button twice within 5s to cancel the timer.
4. Turn on or turn off the unit will cancel the timer.
SETTING COOLING MODE (TARGET TEMPERATURE)
1. With the unit turned on, press the MODE button & choose COOLING mode.
2. Press the UP/DOWN button to set the desired room temperature.
• The selectable range is 16-30
3. Press the FAN button to choose a fan speed from F1 to F3.
4. Press the swing button to set the air outlet flap moving up and down to
o
C or 1oF each time the button is pressed.
by 1
circulate the air more freely if required.
o
C (61-86oF) and the temperature will change
SETTING DRYING (DEHUMIDIFYING) MODE
1. With the unit turned on, press MODE button on the panel to select DRY
mode.
• The fan speed will run at F1and the LED will display the actual room
temperature.
11
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 12
DRAINING OFF THE WATER
The air conditioner has a self-evaporating system. The condensing water will
recycle to cool the condenser, which improves cooling efficiency but also
saves energy and reduces noise. The condensation may eventually collect
faster than the system can cycle and the water container will become full.
When the water container is full, ‘FL’ will flash on the LCD and the appliance
will stop running.
1. Before emptying the water, switch
off and disconnect from the
power supply. Take care not to tilt
the machine causing water to spill
from the collection tray.
2. Remove the drain cap and plug
from the drain port and let the
water flow out into a container.
3. Once drained, replace the plug
and drain cap and switch back
on.
12
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 13
MAINTENANCE
CLEANING
WARNING: ALWAYS TURN OFF THE UNIT AND DISCONNECT FROM THE
POWER SUPPLY BEFORE CLEANING.
1. Clean the outside surfaces of the unit with a duster or a soft, moist cloth.
• Do not use solvents which could damage the plastic components.
2. If the air filters are blocked with
dust, the efficiency of the unit will
be reduced. Clean the filters after
approximately four weeks of use.
3. To remove the air filters, unclip the
grilles and lift away the filters from
inside the grille.
4. Wash the air filters gently in warm
water with a mild detergent. Rinse
the filters and dry them gently out
of direct sunlight.
• Make sure the filter is dry before
use.
5. Clip the filters back into position
and re-fit the grilles.
13
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 14
STORAGE
1. If the appliance is not going to be used for some time, remove the drain
cap/plug and ensure all the water is removed.
2. Operate the unit in FAN mode at low speed until all the drain outlet is dry.
This will discourage the growth of mould inside the unit.
3. Switch off the unit and disconnect the power cable. Coil it around the
hooks at the back of the machine and set the plug in the socket provided.
4. Remove and contract the exhaust duct and store it carefully.
5. Remove the batteries from the remote control to preserve battery life.
6. Cover the unit with a plastic bag and store it in a dry location.
FAULT CODES
The following fault codes can be displayed on the control panel.
Fault CodeDiagnosis of FaultAction Required
E1Coil temperature is
abnormal
E2Room temperature is
abnormal
E4Anti-freezing protectionWaiting for defrosting,
FLWater is full inside the
machine.
Return to Clarke Service
Department to check
coil temperature sensor
or relevant circuit
Return to Clarke Service
Department to check
room temperature
sensor or relevant circuit
function will recover
automatically.
Drain water from drain
port at bottom rear of
unit.
14
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 15
TROUBLESHOOTING
ProblemCheckSolution
The unit fails to
operate
Check for power failure if
unit is plugged in.
Plug the unit into the
socket.
Check the switch is on and
that the fuse is not blown.
Is the set running time
correct?
Check that the water full
alarm is not on.
Room temperature is
unsuitable.
Inefficient coolingUnit is standing in direct
sunlight.
Is air inlet or outlet blocked?
Doors or windows open or
another source of heat in
the room?
Are the air filters very dirty?
Is the set temperature
suitable?
Noise or vibrationIs the unit standing on an
uneven surface?
Compressor doesn't
work
The remote control
doesn't work
Heat protection circuit has
cut in.
The unit is too far away
Batteries are flat.
Remote control not pointing
at the air conditioner.
Replace fuse or switch
on.
Change the set time
duration.
Drain the water
container.
Check that room
temperature is between
O
C
5-35
Draw the curtains to
shield form sunlight.
Clear blockage.
Close windows/doors.
Remove the heat source.
Clean the air filters.
Change the temperature
Stand the unit on a flat,
firm surface.
Wait 3 minutes before restarting unit.
Move closer to the unit
Replace the batteries
Aim the remote control
at the unit.
15
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 16
PARTS DIAGRAM
16
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 17
PARTS LIST
PART NO DESCRIPTIONPART NODESCRIPTION
1Retaining Bracket35Upper Foam Seal
2Discharge Fan Motor36Compressor Exhaust Duct
3Fan Housing Bracket37Condenser Assembly
4Discharge Fan Front Casing38Connecting Pipe Filter
5Discharge Fan39Motor Cover
6Metal Gasket40Pump Flywheel
7Nut41Float Holder
8Discharge Fan Rear Casing42Float
9Evaporator43Sealing Plug
10Air Outlet Grille44Drain Socket
11Moving Cover Base45Control Box
12Moving Cover top46Control Board
13Display Panel47Temperature Sensor
14Top Cover Panel48Capacitor Holder
15Touch Control Panel49Control Box Cover
16Stepping Motor50Capacitor (compressor)
17Fixing Clip51Connector
18Remote Control52Capacitor
19Rear Shell53Transformer
20Upper Filter Screen54Caster Assembly
21Upper Air Grille55Spring Washer
22Lower Air Grille56Compressor Fixing
23Cable Storage Hook57Base
24Lower Filter Screen58Mounting Bolt
25Power Cable59Compressor Foot
26Temperature Sensor PCB60Switch Fixing
27Capillary61Micro Switch
28Water Tray62Support
29Water Tray Sealing Foam63Pump Motor
30Motor64Compressor
31Motor Support Duct65Suction Pipe 1
32Grille66Air Diffuser
33Lower Fan67Front Cover Panel
34Lower Fan Ducting68Receiving Mirror
17
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com