Thank you for purchasing this CLARKE Submersible Pump. These pumps are
ideal for draining ponds, pools and building excavations, these heavy duty
pumps can handle small solids in suspension.
Before attempting to operate the product, it is essential that you read this
manual thoroughly and carefully follow all instructions given. In doing so you
will ensure the safety of yourself and that of others around you, and you can
also look forward to the product giving you long and satisfactory service.
GUARANTEE
This CLARKE product is guaranteed against faulty manufacture for a period of
12 months from the date of purchase. Please keep your receipt as proof of
purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for its intended purpose.
Faulty goods should be returned to their place of purchase, no product can
be returned to us without prior permission. This guarantee does not effect
your statutory rights.
ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the
obligation to deal with the WEEE in accordance with the WEEE
regulations in relation to the treatment, recycling & recovery and
environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
Declaration of Conformity ........................................................... 9
Parts GSE1 & GSE1A ............................................................ 10 & 11
Parts GSE 150 & GSE150A ................................................... 12 & 13
Parts GSE2 & GSE2A ............................................................ 14 & 15
3
Page 4
SPECIFICATIONS
OutletOutletMaxMotorWeight
ModelVoltageInchesL/MinHead MHPKGPart No
GSE1230vac1”1809.50.5207230070
GSE1A230vac1”1809.50.5207230071
GSE150230vac1½”280170.8247230072
GSE150A230vac1½”280170.8247230073
GSE2230vac2”500100.830.57230074
GSE2A230vac2”500100.830.57230075
GSE2110vac2”500100.830.57230076
GSE2A110vac2”500100.830.57230077
NOTE ‘A’ = Models with automatic float switch.
GSE 1/1AGSE 150/150AGSE 2/2A
Please note that the details and specifications contained herein, are correct
at the time of going to print. However, CLARKE International reserve the right
to change specifications at any time without prior notice.
FEATURES
• Continuously rated, fitted with overload protection.
• Corrosion resistant stainless steel casing.
• Cast iron impeller and base for long and reliable service.
4
Page 5
GENERAL SAFETY PRECAUTIONS
AS WITH ALL AMCHINERY, THERE ARE CERTAIN HAZARDS INVOLVED
WITH THEIR OPERATION AND USE. EXERCISING RESPECT AND CAUTION
WILL CONSIDERABLY LESSEN THE RISK OF PERSONNAL INJURY.
HOWERVER, IF NORMAL SAFERY PRECAUTIONS ARE OVERLOOKED OR
IGNORED, PERSONNEL INJURY TO THE OPERATOR OR DAMAGE TO THE
PUMP OR TO PROPERTY MAY RESULT. FOR YOUR OWN SAFETY AND THAT
OF OTHERS AROUND YOU, PLEASE READ THESE SAFETY INSTRUCTIONS IN
CONJUNCTION WITH THE OPERATING INSTRUCTIONS, AND BEFORE
USING THE PUMP.
1. These pumps are designed to pump Water Only. NEVER use for pumping
flammable liquids or chemicals of any kind.
2. An approved Residual Current Device (RCD) MUST be used when
pumping from ponds or swimming pools.
3. Your submersible pump may ONLY be used
for pumping water from a swimming pool
when there is no person or animal in the
pool.
4. If the water is likely to freeze, the pump MUST
be run continuously, otherwise the pump
must be removed from the water and stored
in a frost free location.
5. If the pump is to be used where there may
be silt or mud etc (e.g., garden ponds),
keep the pump clear of any sediment by
standing it on a platform or brick or
suspending from a rope attached to the
handle.
6. NEVER run the pump dry.
7. NEVER run the pump with the body exposed
for longer than 10 minutes.
8. NEVER install the pump on sand, silt, mud or
ground that is likely to shift.
9. NEVER lift the pump by the mains cable, or the float switch cable.
10. ALWAYS use the handle, with rope or chain attached when lifting the
pump.
11. ALWAYS disconnect the pump from the electrical supply before placing it
into, or removing from the water, and before any cleaning or
maintenance of the pump.
5
Page 6
ELECTRICAL CONNECTIONS
230 VOLT MODELS:
Connect the mains lead to a standard 230 Volt (50Hz) electrical supply through an approved
BS1363, 13amp plug or a suitably fused isolator switch.
110 VOLT MODELS:
Connect the mains lead to a suitable 110 Volt (50Hz) electrical supply through an approved
plug or a suitably fused isolator switch. If using a portable 110 Volt transformer make sure it
has a rated capacity sufficient to take the load of the pump.
ALL MODELS:
We recommend that this pump is connected to the mains supply through a Residual Current
Device (RCD).
WARNING! THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the following
code:
As the colours of the flexible cord of this appliance may not correspond with the coloured
markings identifying terminals in your plug proceed as follows:
•Connect GREEN & YELLOW cord to terminal marked with a letter “E” or Earth
symbol “ ” or coloured GREEN or GREEN & YELLOW.
•Connect BROWN cord to terminal marked with a letter ‘L’ or coloured RED
•Connect BLUE cord to terminal marked with a letter ’N’ or coloured BLACK
Green & Yellow-Earth
Blue-Neutral
Brown-Live
230 VOLT MODELS:
If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. nonrewirable) please note:
1. The plug must be thrown away if cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket.
2. Never use the plug without the fuse cover fitted.
3. Should you wish to replace a detachable fuse carrier, ensure that the
correct replacement is used (as indicated by marking or colour code).
4. Replacement fuse covers can be obtained from your local dealer or most
electrical stockists.
5. The fuse in the plug must be replaced with one of the same rating
(13amps) and this replacement must be ASTA approved to BS1362.
IMPORTANT:
If you are in any doubt regarding electrical installation,
you should consult a qualified electrician
6
Page 7
OPERATION
Connect a length of delivery hose (not supplied) to the outlet spigot of the pump (GSE and
GSE1A pumps require1” hose, GSE2 and GSE2A require 2” hose). Suitable hose is available
from your nearest CLARKE dealer.
CLARKE submersible pumps are designed for use with fresh water. Avoid using your pump
with salt water, or with water containing chemicals, as these can cause damage to the
pump. If the pump does come into contact with salt or water containing chemicals, wash
it immediately. GSE pumps will handle small solids in suspension, making it suitable for draining
sumps, pits and excavations etc.
Inspect the pump regularly to check that the base inlet is clear of leaves or other debris.
Any blockage of mud or leaves can be cleared by washing the pump in fresh water, or by
using a hose to flush fresh water back through the pump outlet connector. Never switch on
the pump with the outlet connected to the mains water supply.
GSE 1A, 150A and 2A pumps incorporate an automatic float switch. As the water level
rises, the switch will float, and start the pump. As the water level falls, so will the float switch,
which in turn will switch the pump off. The position of the float switch can be adjusted by
repositioning the cable in its clip.
For the float switch to operate correctly it must be able to move freely. When putting the
pump into position, ensure there is nothing which might impede the float switch movement.
GSE pumps are fitted with automatic overload protection. If the motor overheats (because
of an obstruction in the pump, or pumping warm water, for example), it will shut off
automatically. Switch the pump off and isolate from the main electric supply, check for
blockages, and remove, allow the motor to cool down before attempting to restart. The
thermal overload will normally reset in a few minutes.
This pump should require little or no maintenance other than regular cleaning. If the pump
starts to show signs of wear or damage, contact you nearest CLARKE dealer for advice. Do
Not use the pump if there is any damage to the mains supply or float switch cable.
Do Not attempt to repair the pump yourself, (other than to replace listed parts on pages 10
& 12), as you may invalidate your guarantee, and damage the waterproof seal of the
pump.
If using this pump in a garden pond, please note that there is a small quantity of oil in the
pump seal. If the pump seal is worn or damaged, oil may leak out, and appear as a film on
the surface of the water. Although harmless to people, the oil must be cleared to prevent
any possible harm to pond life. Disconnect the pump from the electrical supply, remove it
from the pond, clear the oil and contact the CLARKE service department for advice, on
020 8988 7400.
Once satisfied the pump is installed, and taking all the necessary safety and electrical
precautions as described on pages 4 & 5, plug into the mains supply and switch ON.
NOTE:
If the pump does not deliver immediately, it is possible that an air lock exists, Leave the
pump for approximately one minute in order for the air lock to be displaced. If necessary
switch OFF and On again, the pump should now deliver water, if not check all hose
connections etc.
SUITABLE HOSE, and SPARE/REPLACEMENT HOSE ADAPTERS ARE
AVAILABLE FROM YOUR NEAREST CLARKE DEALER
7
Page 8
MAINTENANCE
WARNING; Before carrying out any maintenance activities to your
submersible pump, ensure it is isolated from the mains supply, by switching
OFF and removing the plug from the socket.
Your submersible pump should require no maintenance other than regular
inspection and cleaning.
Check the pump installation regularly to ensure the base inlet is clear of
leaves or other foreign objects, mud silt etc.
if the pump starts to show signs of wear or damage, contact your nearest
Clarke dealer for advice.
DO NOT ATTEMPT TO CARRY OUT REPAIRS TO THE PUMP YOURSELF UNLESS YOU ARE FULLY
COMPETENT. REMEMBER WATER AND ELECTRICITY DO NOT MIX.
If in any doubt, contact your nearest CLARKE dealer for advice.
TROUBLE-SHOOTING
A.Pump Will Not Start
1. Float switch may be jammed against side wall, or prevented from moving.
2. Water level too low - float switch in OFF position - lift float to check switch.
B.Pump Will Start But Not Deliver
1. Check to ensure base is not blocked by leaves etc.
2. Discharge tube blocked or obstructed etc.
3. The head may be too great, i.e., you are trying to lift water too great a
distance for the pump to cope with. (See specifications on page 3).
4. Impeller may be damaged - contact your nearest CLARKE dealer.
5. Air lock in system. Switch OFF and ON again to dearate the system.
C.Pump Will Not Stop
1. Float switch may be prevented from moving to fully down position.
2. Float switch may be faulty - contact your nearest CLARKE dealer.
D.PUMP STOPS RUNNING
1. Thermal overload has operated, switch OFF, allow to cool down, switch on
again. Check for possible causes for motor to overheat.
2. Float switch has operated. Check operation of switch.
3. No electrical; supply.... investigate cause, i.e., check fuse/RCD etc.
27GM7137Float Switch (GSE 150A)1
28GM7107‘O’ Ring 2.9 x 1.784
29GM7113Screw4
30GM6429Gasket1
31GM6705Flange For Cable Connection1
32GM7123Stop Cable1
33GM7099Inox Screw1
34GM7144Inox Nut1
35GM7875Cable-Lock1
36GM7876Cable-Lock For Float Switch1
37GM1035Connection 1” x 401
38GM1095Nipple From 1/2” to 1-1/2”1
13
Page 14
Parts Diagram (GSE 2 & 2A)
14
Page 15
Parts List (GSE 2 & 2A)
INDEXPART NUMBERDESCRIPTIONQTY
1GM835710M Cable With Plug for GSE 230V1
1AGM835610M Cable Without Plug for GSE 110V1
2GM8211Inox Handle1
3GM8185Inox Nut2
4GM8235Condenser 16MY For GSE 230V1
4AGM8236Condenser 20MY For GSE 110V2
5GM7093Superior Flange1
6GM7105‘O’ Ring 107.7 x 1.782
7GM7111Bearing 62032
8GM8113Motor For GSE 230V1
8AGM8100Motor For GSE 110V1
9GM8269Inox Screw4
10GM7097Inox Washer4
11GM7082Pump Body1
12GM7109Flexolite Gasket1
13GM7084Bracket1
14GM6062Gasket1
15GM7103Brass Nut1
16GM7005Base1
17GM6623Impeller1
18GM5442Inox Screw3
19GM6774Filter1
20GM7147Counterface2
21GM7153Mechanical Seal2
22GM7117Tap 1/8”2
23GM6048‘O’ Ring 2037-1102
24GM7098Inox Screw4
25GM7106‘O’ Ring 45122
26GM7092Inferior Flange1
27GM9879Inox Housing For GSE 21
27AGM9878Inox Housing For GSE 2A1
28GM7137Float Switch (GSE 2)1
29GM7107‘O’ Ring 2.9 x 1.784
30GM7113Screw4
31GM6429Gasket1
32GM6705Flange For Connection Cable1
33GM7123Stop Cable1
34GM7099Inox Screw1
35GM7144Inox Nut1
36GM7875Cable-Lock1
37GM7876Cable-Lock For Float (GSE 2A)1
37GM1017Connection 2” x 501
38GM1095Nipple From 2” to 2”1
IMPORTANT:
The use of parts other than CLARKE replacement parts may result in safety hazards,
decreased tool performance and may invalidate your warranty.
15