www.clare.com
PAA110L
Rev. 4
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25˚ C)
2
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 50 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 8002mW
Isolation Voltage
Input to Output 3750 - - V
RMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Flatpack/Surface Mount
Package - - +220 °C
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/˚C
2
Derate Linearly 6.67 mw/˚C
Electrical Characteristics
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Voltage (Peak) - V
L
- - 250 V
Load Voltage (Peak) - V
L
- - 400 V
Load Current* (Continuous)
AC/DC Configuration - I
L
- - 150 mA
Peak Load Current 10ms I
LPK
---mA
On-Resistance
AC/DC Configuration I
L
=150mA R
ON
-1825Ω
Off-State Leakage Current V
L
=400V I
LEAK
--1µA
Switching Speeds
Turn-On I
F
=5mA, VL=10V T
ON
--1ms
Turn-Off I
F
=5mA, VL=10V T
OFF
- - 0.25 ms
Output Capacitance 50V; f=1MHz C
OUT
-25-pF
Load Current Limiting I
CL
190 235 280 mA
Capacitance
Input to Output - - - 3 - pF
Input Characteristics @ 25°C
Input Control Current I
L
=150mA I
F
5-50mA
Input Dropout Current - I
F
0.4 0.7 - mA
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Reverse Input Voltage - V
R
--5V
Reverse Input Current V
R
=5V I
R
- - 10 µA
Input to Output Capacitance - C
I/O
-3-pF
Input to Output Isolation - V
I/O
3750 - - V
RMS
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.