Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Voltage (Peak) - V
L
- - 400 V
Load Current* (Continuous)
AC/DC Configuration - I
L
- - 150 mA
Peak Load Current 10ms I
LPK
- - 400 mA
On-Resistance
AC/DC Configuration IL=150mA R
ON
-1522Ω
Off-State Leakage Current VL=400V I
LEAK
--1µA
Switching Speeds
Turn-On I
F
=5mA, VL=10V T
ON
--1ms
Turn-Off IF=5mA, VL=10V T
OFF
- - 0.25 ms
Output Capacitance 50V; f=1MHz C
OUT
-25-pF
Load Current Limiting I
CL
---mA
Input Characteristics @ 25°C
Input Control Current IL=150mA I
F
5-50mA
Input Dropout Current - I
F
0.4 0.7 - mA
Input Voltage Drop IF=5mA V
F
0.9 1.2 1.4 V
Reverse Input Voltage - V
R
--5V
Reverse Input Current VR=5V I
R
- - 10 µA
Input to Output Capacitance - C
I/O
-3-pF
Input to Output Isolation - V
I/O
3750 - - V
RMS
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 50 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 8002mW
Isolation Voltage
Input to Output 3750 - - V
RMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Flatpack/Surface Mount
Package - - +220 °C
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/˚C
2
Derate Linearly 6.67 mw/˚C
www.clare.com
2
PAA110
Rev. 3.0
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of
the device to the absolute maximum ratings for an extended period may degrade the device and effect its reliability.
Absolute Maximum Ratings (@ 25˚ C)
Electrical Characteristics