Claind Nitro70, Nitro35 User Manual

User’s manual
Nitrogen Generators
Nitro35 Nitro70
Table of contents
1. Introduction 3
2. Safety 4
3. Description of the generator 6
4. Installation 9
2
Nitrogen Generators Nitro35 Nitro70
1.
Introduction
This document is intended for users of Nitrogen generators model Nitro35 and Nitro70 and provides all information regarding installation, use, maintenance, and guarantee. With regard to installation and maintenance, it is presumed that the user is expe­rienced in the use of pneumatic components, and in particular is aware of all sa­fety aspects linked to the use of compressed air and nitrogen.
The margin of the text contains the following symbols, indicating:
m c
e
compulsory safety standards to be observed
electrical hazard
recommendations and important information
It is strongly recommended to carefully read all safety warnings ( before carrying out any operation on the generator.
par. 2.1.
)
3
Safety
2.
Safety
These generators can be installed next to the users without having to classify the nearby area as “dangerous”, since it has been designed with all the neces­sary precautions to guarantee maximum safety.
e
e
2.1.
m m
c
The unit must be installed and used in observance of the instructions in this booklet. Furthermore, use of the generator must be limited to that described in
Chapter 1 Introduction
guarantee null and void and release CLAIND from all liability for direct or indirect damage or physical injury.
The user is responsible for asking local authorities if there are local safety regulations that are stricter than what is described in this manual.
. Failure to observe the foregoing will render the
Warnings
Place the generators FAR FROM SOURCES OF HEAT
Place the generators in an environment PROTECTED AGAINST RAIN AND WIND
NEVER OPEN the generator while it is connected to the electrical mains: RISK OF FATAL INJURY BY ELECTROCUTION
e
e
2.2.
Repairs and inspections must be carried out exclusively by QUALIFIED PERSONNEL: in the event of faults which cannot be resolved according to the procedures listed in the TROUBLESHOOTING chapter, contact exclusively our authorized Technical Assistance.
If the generator has not to be used for a prolonged period of time, it must be depressurised (par. 6.5.)
Consideration on the use of nitrogen
Nitrogen isn’t a toxic gas, but when the percentual content of the air exceed de­terminated values suffucation risk can occur. We recommend therefore to not breath the gas directly and not to work in the nearby of the Nitrogen flux. Due to the low quantities of Nitrogen produced, a normally ventilated enviro­ment is anyway sufficient to prevent the accumulation risk.
4
Nitrogen Generators Nitro35 Nitro70
2.3.
m
2.4.
e
Safety devices
MAXIMUM PRESSURE:
The maximum applicable compressed air pressure to generators is 10 bar. Ple­ase pay attention that this value doesn’t exceed in order to avoid explosion risk due to the structural failure of the components. Pressure in the built-in reservoir is limited by a safety valve.
Technical assistance
CLAIND disclaims any liability for any damages caused from improper use of the generator.
Please contact CLAIND Service center before of any kind of intervention. CLAIND technical assistance can be contacted as follows: Phone ++39 0344 56603 Fax ++39 0344 56627 e-mail: service@claind.it
5
Description of the generator
3.
Description of the generator
3.1.
3.2.
3.2.1.
Equipment supplied
Unless differently agreed, the supply includes:
• n°1 Nitrogen generator model Nitro35 or Nitro70;
• n°1 certificate of conformity of tank and safety valve, that you can found inside the generator;
• n°1 cable for the electrical mains;
• n°2 male fitting for plastic tube external diameter=10mm;
• n°1 CD user’s manual;
• n°2 eyebolts for lifting the generator;
• n°4 feet;
• n°4 stabilizer brackets;
• n°8 screw diameter 6mm, lenght 20mm;
• n°8 washers.
Technical specifications
General requirements
Dimensions Width 26,5 cm
Depth 75 cm Height 92 cm
Weight of Nitro35 75 kg Weight of Nitro70 90 kg Packing dimensions Width 80 cm
Depth 120 cm Height 115 cm
Gross weight of Nitro35 95 kg Gross weight of Nitro70 110 kg Noise (1m from the front panel) 50 dBA* Working temperature from 5°C to 40°C Protection rating IP20
* with the exception of a peak of 63 dBA for second every minute.
6
Nitrogen Generators Nitro35 Nitro70
3.2.2.
3.2.3.
Electrical requiremets
Supply voltage 230 V~ (±10%); 1ph; 50Hz Nominal power 30 W
Gas
Flow rate and purity degree of nitrogen outlet vary depending on the kind of uti­lization and of application. The technical specification of this model are indicated on the related product sheet.
7
Description of the generator
E
C
A
D B
C D
A B
3.3.
3.3.1.
3.3.2.
Generator components
Frontal view
A. ALPHANUMERIC DISPLAY AND
KEYPAD: they indicate the alarm and operative condition; the four keys allow to display and set the working parameters.
B. NITROGEN GAUGE: it indicates the
outlet Nitrogen pressure
C. “POWER” KEY: it is the power switch.
D. AIR GAUGE: it indicates the
compressed ari pressure of the intake line of the generator
E. PRESSURE REGULATOR: it allows to
set the outlet Nitrogen pressure
Rear view
A. LABEL: it shows the identificative data
of the generator and the power supply data.
B. CONNECTORS for the power supply
cable; it includes the main FUSE lodging, whose characteristics are indicated in the “F” label.
C. NITROGEN: pneumatic connection
(G 1/4’’ female) for nitrogen line to be connected to the user.
D. AIR: pneumatic connector for
compressed air line (G 1/4’’ female)
8
Nitrogen Generators Nitro35 Nitro70
4.
Installation
4.1.
4.1.1.
4.1.2.
4.2.
4.2.1.
Installation preparation guide
Moisture and particulate
In order to avoid damages to the electronic components, we recommend to in­stall the generator in a area where the relative moisture and the dust concentra­tion are limited. Moreover, the generator must be protected from dripping, rain and wind.
Temperature
Environmental temperature of the area of the installation must be between 5°c and 40°c. Please avoid proximity to heat sources. Please avoid the direct exposition to sun beams.
Generator positioning
Handling
m
e
4.2.2.
The packed generator can be handled using an adequate instrumentation, such as a transpallet or a fork lift. Once unpacked, it can be moved by his own wheels.
If suddenly moved the generator could fall and generate damage to things or persons.
The generator must be always kept in vertical position since it has not been de­signed to be layed down.
Unpacking
The generator is shipped on a dedicated pallet. Please remove packing paying attention not to damage the panels of the gene­rator. When possible, please keep the original packing to guarantee an adequate pro­tection of the generator in case of future handling.
9
Loading...