Clack T.F.C.-400 Installation, Operation & Service Manual

Page 1
R.O. DRINKING WATER SYSTEM
MODEL T.F.C.-400
INSTALLATION, OPERATION & SERVICE MANUAL
IMPORTANT NOTICES:
This reverse osmosis system contains replaceable treatment components critical for effective performance. It is the user's responsibility to, and the manufacturer strongly recommends that the user, periodically test the product water to verify the system is performing satisfactorily.
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY, WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
Page 2
TABLE OF CONTENTS
Page
SECTION I. INTRODUCTION ...................................................................................3
SECTION II. SPECIFICATIONS ................................................................................5
SECTION III. INSTALLATION STEPS ........................................................................6
A. Faucet Installation ...........................................................................6
B. Feed Water Saddle Valve Installation .............................................8
C. Drain Clamp Installation ..................................................................8
D. R.O. Manifold Assembly Installation ...............................................9
E. Position the Drinking Water Holding Tank
and Make the Final Hose Connections .........................................10
F. Start Up .........................................................................................10
SECTION IV. OPERATION AND MAINTENANCE ...................................................11
A. Normal Operation ..........................................................................11
B. Changing Filters ............................................................................ 11
C. Changing the In-Line Activated Carbon Post Filter .......................12
SECTION V. TROUBLE SHOOTING GUIDE ...........................................................16
EXPLODED VIEW AND PARTS LIST ..................................................................................18
Page 3
SECTION I. INTRODUCTION
Your new Reverse Osmosis (R.O.) Drinking Water
System uses a combination of ltration technologies to
reduce unwanted contaminants in a water supply. The following steps combine to give you the best in clear sparkling drinking water:
MECHANICAL FILTRATION–The Sediment Prelter
has been designed to reduce the larger particles such as silt, rust and scale. Its 5 micron (equal to 0.0002 inch) nominal rating R.O. Membrane.
helps to give maximum life to the
ACTIVATED CARBON–The Activated Carbon
Prelter contains carbon particles with a vast network
of pores. The tremendous surface area of these pores (typically 800–1200 square meters per gram of carbon) gives the carbon very good adsorptive sites for substances that contribute to tastes and
odors. The activated carbon in the Prelter has been
designed to reduce any chlorine that may be present in the feed water. This pretreatment is necessary for membrane protection.
REVERSE OSMOSIS MEMBRANE–The R.O.
Membrane is the heart of the ltration system. It is
designed to reduce the dissolved mineral content of
the water. Minerals picked up in the environment by the water are measured as Total Dissolved Solids (TDS). In the Reverse Osmosis process, dissolved minerals are separated from the incoming water (Feed Water) to produce the product water (the Permeate). The excess minerals are rinsed to drain (the Reject Water).
The membrane is a specially constructed, fully
aromatic polyamide lm, and is classied as a Thin
Film Composite (T.F.C.).
The spiral wound construction of the R.O. Membrane
provides maximum surface area for water production and is less susceptible to fouling by particulate matter, turbidity and colloidal materials.
IN–LINE ACTIVATED CARBON POST FILTER–The
In–Line Activated Carbon Post Filter is located after the Holding Tank and has been designed to reduce the tastes and odors that may pass through the
system. It adds a nal polish to the water.
AUTOMATIC SHUTOFF VALVE–The ASO Valve
senses when the Holding Tank is full and closes the feed water supply to prevent excess reject water from going to drain when the unit is not producing water.
Close-up of Manifold
DRAIN
BLACK
RESTRICTOR
YELLOW
RED
See Page 9
TYPICAL T.F.C.–400 UNDER SINK INSTALLATION DIAGRAM
IN
DRAIN
OUT
HOLDING TANK
SHUTOFF VALVE
(Open Position)
7
HOLDING TANK
6
DRINKING
WATER
5
FEED WATER
SADDLE VALVE
(Cold Water Line Only)
TANK
(3/8" Yellow)
DRAIN
(3/8" Black)
LOCATE DRAIN CLAMP
ABOVE "P" TRAP
1
PRODUCT
(3/8" Blue)
(1/4" Black)
(1/4" Red)
(1/4" Yellow)
4
POLYTUBE TEE
DISPENSING FAUCET WITH AIR GAP
DRAIN CLAMP
2
8
IN-LINE ACTIVATED CARBON POST FILTER
DRAIN
INLET
REVERSE OSMOSIS
4" MIN
MEMBRANE HOUSING
ACTIVATED CARBON PREFILTER HOUSING
RO MANIFOLD
SEDIMENT PREFILTER HOUSING
Figure 1
3
Page 4
OPTIONAL T.F.C.–400 BASEMENT INSTALLATION DIAGRAM
Close-up of Manifold
FLOOR
POLYTUBE
TEE
IN-LINE ACTIVATED CARBON POST FILTER
FEED WATER
SADDLE VALVE
(COLD WATER
LINE ONLY)
1” AIR GAP REQUIRED
DISPENSING FAUCET
PRODUCT (3/8” Blue)
INLET
(1/4” Red)
DRAIN
(1/4” Black)
(1/4" Yellow)
REVERSE OSMOSIS
MEMBRANE
HOUSING
DRAIN
BLACK
RESTRICTOR
YELLOW
RED
See Page 9
NOTE: FOR REFRIGERATOR WATER DISPENSER OR ICE MAKER HOOKUP, TEE INTO 3/8" BLUE TUBING TO DISPENSING FAUCET.
HOLDING TANK SHUTOFF VALVE (Open Position)
TANK
(3/8” Yellow)
RO MANIFOLD
ACTIVATED
CARBON
PREFILTER
SEDIMENT PREFILTER
HOUSING
HOUSING
IN
DRAIN
OUT
DRINKING
WATER
HOLDING
TANK
MOUNT HOLDING TANK ON SHELF OR STRAP BETWEEN FLOOR JOISTS (shelf or straps not included)
BASEMENT
FLOOR
PLEASE NOTE: IF AIR GAP IN FAUCET IS NOT USED IN BASEMENT INSTALLATIONS, A PROPER AIR GAP MUST BE CREATED. PLEASE CHECK WITH LOCAL PLUMBING CODES. SEE EXAMPLE ABOVE.
4
Page 5
SECTION II. SPECIFICATIONS
TABLE A – QUALIFIED SYSTEM PERFORMANCE
Because the performance of an R.O. Membrane is highly dependent upon pressure, temperature and TDS, the
following should be used for comparison purposes only.
U.S. Metric
Membrane Production
Membrane TDS Reduction
1
40-60 gpd 151–227 lpd
1
93% minimum 93% minimum
Drain (reject water) Flow 3–5 x product ow 3–5 x product ow
Empty Storage Tank Precharge 5–7 psig air 35–48 kPa air
1
Industry standards measure R.O. Membranes performance with no backpressure on the product water, at 65 psig (448kPa) and 77°F
(25°C). Further conditions on the above are 600 ppm TDS. Production rate and TDS reduction gures are for a new Membrane that
has been rinsed for 24 hours. The production rate of a new Membrane can decrease by 10% per year or more, depending upon the scaling and fouling tendencies of the Feed Water.
TABLE B – RECOMMENDED OPERATING LIMITS FOR FEED WATER
Specications    T.F.C. Membrane
Water Pressure 40–100 psig (280–690 kPa)
TDS 2000 ppm (also mg/l) max.
Temperature 40–100°F (4–38°C)
pH 4–11 (optimum rejection at pH 7.0 - 7.5)
Hardness Less than 10 gpg (170 mg/l) or soften
Iron Less than 0.1 ppm (also mg/l)
Manganese Less than 0.05 ppm (also mg/l)
Hydrogen Sulde None
Chlorine See note
Bacteria Must be potable**
NOTE: Chlorine will damage a T.F.C. Membrane. The Activated Carbon Prelter has been designed to reduce chlorine from the  incoming water. Change lter every 6 to 12 months, more often if the water contains more than 1 ppm chlorine.
**DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY, WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
5
Page 6
SECTION III. INSTALLATION STEPS
All plumbing should be done in accordance with
state and local plumbing codes.
NOTE: Some codes may require installation by a
licensed plumber; check with the local plumbing authority prior to installation.
In restricted under–sink areas, it may be easier to
install the faucet rst. Allow adequate tubing lengths for any nal component position.
2c. Drilling a counter top:
NOTE: The counter top must be less than
1¼" thick. Treat ceramic tile as porcelain until the tile is penetrated, then use the carbide tipped metal cutter.
Formica counter tops may be drilled with a
good 1¼" wood bit; drilling a
3
/32" pilot hole
will help keep the bit going straight.
A.  Faucet Installation –
The faucet contains
an anti–siphon air gap. While the system is
producing water, the drain water ows from
the R.O., through the air gap and then to the household drain. The purpose of the air gap is to prevent water in the drain from backing up into the R.O. Drinking Water System.
The easiest installation is to use an existing
spray attachment hole. If the spray faucet hole is not available, then the sink top must be drilled.
1. Mark the location of the center of the faucet base.
2a. Drilling a stainless steel sink:
•Center punch the hole to provide a starting
point for the drill.
•Start with a smaller drill as a pilot, and then
drill a ½" diameter hole to accept the bolt of a 1¼" Greenlee Hole Punch (1¼" chassis punch).
•Clean away any chips.
•Install the punch and tighten the nut to cut
the hole.
3. Assemble the 1/8” Screws & Toggle Wings into the Faucet Base. Adjust the Wings approximately 1” plus the thickness of the mounting surface away from the bottom of the Faucet Base.
•Deburr any sharp edges.
2b. Drilling a porcelain sink:
It is best to use a special 1¼" diameter cutter
designed for porcelain. A carbide tipped masonry bit is a second choice.
•Place a piece of tape over the area to be
drilled to help prevent chipping.
•Drill a pilot hole for the porcelain cutter.
Use the pilot drill supplied with the kit or a carbide tipped drill.
•When drilling the 1¼" hole, drill slowly and
carefully; the porcelain chips easily.
•After drilling, clean the area well. Iron lings,
if left in place, can cause rust stains.
6
Page 7
4. Place the Base Assembly through the mounting hole on the sink or counter top.
Drop the handle of the Wrench through the Faucet Base opening. This will separate and orient the Toggle Wings. Position the Faucet Base so that the arrows are pointing in the direction that the faucet handle will face.
Tighten the 1/8” Screws with a Phillips screwdriver. When the Toggle Wings make contact with the mounting surface, adjust the Faucet Base to the exact desired position. Tighten the 1/8” Screws an additional 2 –3 turns while holding the Faucet Base in place.
TAB
HOSE BARBS
6. Determine which direction the handle should face (right or left). As shown, it can be mounted in two directions. With the handle facing the chosen direction, slide the fastened Polytubes through the Faucet Base and slide the Faucet Assembly into the Faucet Base, lining up the tabs on the Faucet with the slots on the Base. The Faucet Assembly may have to rotate slightly to get the tabs into the slots. When aligned, apply
rm downward pressure to get the Faucet
to fully seat. After the Faucet Assembly is seated, lock it into place by rotating it clockwise about 30 degrees.
3/8” QUICK
CONNECT FITTING
BLACK 1/4” POLYTUBE
(TO DRAIN PORT
ON RO SYSTEM)
BLUE 3/8” POLYTUBE
(PRODUCT OUTLET)
BLACK 3/8” POLYTUBE (TO DRAIN CLAMP)
5. Connect the tubing to the Faucet. Push the Blue 3/8” Polytube into the 3/8” Quick Connect Fitting. Push the Black 3/8” Polytube onto the large Hose Barb. Push the Black ¼” Polytube onto the small Hose Barb.
7
Page 8
Handle
Compression
Red Tubing To
FEED WATER SADDLE VALVE
Cold Water
Line
Saddle
Valve
Tightening
Insert
Plastic
Ferrule
Nut
Manifold
Inlet
Figure 3
Screw
Reversible Back Plate
2b. To install on (hard) Steel or Brass Tubing
supply line.
•The supply line should now be drained. Use
a battery powered or properly grounded drill to avoid shock hazard.
•Drill a
3
/16" hole in the supply line; (do not
drill through the opposite wall).
•Turn the handle to expose the lance no
more than
3
/16" beyond the rubber gasket.
•Place the body of the valve over the hole so that the lance ts into the hole.
•Assemble and tighten the brass screw.
•Turn the Valve Handle clockwise (inward) until rmly seated. The valve is closed.
3. With the Feed Water Saddle Valve closed, open the sink faucet and the water supply and allow the water to run for a few minutes
to ush any debris caused by the installation.
B.  Feed Water Saddle Valve Installation 
Decide on location. Do NOT connect to a
hot water feed line. If you are not sure of the supply, run the hot water and feel the supply piping. Water over 100°F may cause permanent damage to the R.O. Membrane. (Refer to Fig. 3.)
1. Shut off the water supply and drain the line.
2a. To install on (soft) Copper Tubing supply
line:
•Turn the Handle of the Feed Water Saddle
Valve counter clockwise (outward) until the lance does not protrude from the gasket. It may have to be pushed in.
•Assemble the Feed Water Saddle Valve on
the tubing.
3
– for
/8" OD tubing use the back plate side with the small groove to prevent distortion of the tubing.
– for larger tubing (up to
5
/8" OD) use the
large groove of the back plate.
• Close the faucet and check the Feed Water
Saddle Valve for leaks.
C.  Drain Clamp Installation
3/8" DRAIN CLAMP ASSEMBLY
Drain Pipe
Drain Clamp Front Plate
1/4" Screw
Black Drain Tubing
1/4" Nut
Drain Clamp Back Plate
•Assemble and tighten the brass screw.
•To pierce the tubing, turn the Valve Handle
fully clockwise (inward). A small amount of water may escape from the outlet until it is fully pierced.
•When you feel the Valve Handle rmly
seated in the clockwise direction, the copper tube is pierced and the valve is closed.
Figure 4
The following are instructions for discharging
into the sink drain pipe. (Refer to Fig. 1.)
1. Position the Drain Clamp on the sink drain pipe above the drain trap. Allow room for drilling. Tighten securely.
8
Page 9
2. Use a battery powered or properly grounded drill. Using the Clamp port as a drill guide,
7
drill a
/32" hole through the wall of the drain pipe. Do NOT penetrate the opposite side of the pipe.
3. Locate the
3
/8" Black Drain Tubing connected to the Dispensing Faucet. Route the tubing to the Drain Clamp and trim to length.
NOTE: When cutting the polytubing make
clean, square cuts, failing to do so could result in poor connections and possible leaks.
NOTE: The lowest point of the line should be
the point of connection to the Drain Clamp. There should be no sag in the line as this may cause excessive noise as the reject
water is owing to drain.
Route the tubing to the Drain Clamp and
trim to length. Insert the tubing into the Drain Clamp. Make sure the tubing is pressed all the way in.
IN
DRAIN
OUT
DRAIN
RED
BLACK
RESTRICTOR
YELLOW
2. Locate the ¼" Red Feed Water Tubing.
Remove the red plug from the tting labeled
“In” on the manifold and insert the tubing. Reference the special supplement sheet in the carton for proper connection of all tubing and removal of plugs. Run the tubing along its course to the Feed Water Saddle Valve, trim to length. (Refer to Fig. 1.)
Refer to Fig. 3. To the end of the red polytube
install the Compression Nut, the Plastic Ferrule, and the Insert. Connect to the Feed Water Saddle Valve.
D.  R.O. Manifold Assembly Installation 
Various installation sites will require different
types of mounting fasteners; be sure the
fastener selected will provide a rm, solid
mounting. A support panel may be necessary on thin cabinet walls or to span between wall studs on particleboard or drywall.
Do not drill through exterior cabinet walls or
leave sharp wood screw points exposed in readily accessible cabinet interiors.
The close proximity of a dishwasher or a trash
compactor may require special fabrication of a mounting plate.
1. The mounting bracket will accept either #10 or #12 (5mm) mounting screws spaced on 6" (15 cm) centers. Allow at least 4" (10 cm)
of clearance beneath the lter housings to accommodate lter changes. Mark the two
locations (the bracket can be used as a template). Install the screws and tighten them until the heads are about
5
/8" from the wall.
3. Locate the ¼" Black Drain Tubing connected to the Dispensing Faucet. Remove the black
plug from the tting labeled “Drain” on the
manifold. The end of the Black Drain Tubing that should be inserted into the “Drain” port will have a drain restrictor in it.
4. Locate the ¼" yellow tubing with the tee attached to one end. Remove the yellow plug
from the tting labeled "Out" on the manifold
and insert the tubing.
5. Locate the
3
/8" Blue Product Water Tubing
connected to the faucet. Firmly press one
end into the tee. (Refer to Fig. 1.) The tting
will grab the tubing and seal it in place. Make sure the tubing is pressed all the way in to create a pressure tight connection.
6. Hang the Manifold Assembly on the mounting screws and tighten. DO NOT OVERTIGHTEN.
7. Remove the wrapping from the In–Line Activated Carbon Post Filter. Slice
3
the
/8" Blue Polytube where it would be convenient to install and change the In–Line Filter. Make a clean straight cut to insure proper connections. The “Out” port on the In–Line Filter should be towards the faucet.
Firmly press in the tubing. The ttings will
grab the tubing and hold and seal it in place. Make sure the tubing is pressed all the way in to create a pressure tight connection.
9
Page 10
E.  Position the Drinking Water Holding Tank 
and Make the Final Hose Connections. 
1. Check the tank precharge pressure. Make sure it is between 5 to 7 psig. If not, use a bicycle hand pump or other pump to bring the pressure up to the 5 to 7 psig range.
2. Pull the cap/plug off the top of the tank where the Tank Shut–Off should go. (Refer to Fig.
1.)
3. Wrap Teon tape three times around the ¼"
male outlet thread. Wrap in the direction of the threads (clockwise when looking down on the Holding Tank). The tape will act as a thread sealant. Screw on the Holding Tank Shut–Off Valve.
4. Locate the
3
/8" Yellow Tubing. Firmly press one end into the Holding Tank Shut–Off Valve and the other end into the tee. (Refer to Fig.
1.) The ttings will grab the tubing and seal
it in place. Make sure the tubing is pressed all the way in to create a pressure tight connection.
F.  Start Up 
At time of start up and each time the lters are
changed the system should be sanitized (also see Operation and Maintenance Sec. IV, B.1–4).
1. Sanitizing the system and installing the
Sediment Prelter. Use a drip pan to aid
clean–up.
NOTE: The system should be sanitized
BEFORE installing the Activated Carbon
Prelter and the RO Membrane.
•Use a good quality unscented 5¼% liquid
chlorine household bleach.
•Open the Dispensing Faucet and open the
Holding Tank Shut–Off Valve (the handle should be parallel with the valve body).
•Remove the plug on the underside of the
manifold labeled “SEDIMENT”. Pour one capful of bleach (this is approximately 2 tsp. or 10 ml) into one of the white Housings. AVOID GETTING BLEACH ON THREADS AND O-RINGS. Unwrap
Sediment Prelter and install prelter
(O-rings up toward manifold.) Insert a Housing O–ring into the Housing groove,
(press rmly in place). Engage and rmly
tighten the Housing hand tight only.
•Remove the plugs labeled “ACTIVATED
CARBON” and “MEMBRANE” from the underside of the manifold. To each of the remaining white Housings, add one capful of bleach. AVOID GETTING BLEACH ON THREADS AND O-RINGS. Insert a Housing
O–ring, engage and rmly tighten the
Housings hand tight only.
•Slowly open the Feed Water Saddle Valve
(turning counter clockwise).
•As soon as the water begins to come out of
the Dispensing Faucet, close the Faucet.
•Let stand for 15 minutes.
NOTE: During this time, check the system
carefully for leaks.
•At the end of 15 minutes, CLOSE the
Feed Water Saddle Valve and open the Dispensing Faucet.
•Allow the Holding Tank to completely drain. Then remove the Activated Carbon Prelter
Housing (the middle one), empty, and install
the Activated Carbon Prelter. Firmly tighten
the Housing hand tight only.
2. Installing the R.O. Membrane:
•Remove the R.O. Membrane Housing, (the
closest of the three to In/Out ports), and empty.
•Insert the Membrane up into the manifold.
(The O–rings should be up toward the manifold.) Check the Housing O–ring for proper position in its groove, engage and
rmly tighten the Housing hand tight only.
3. Rinsing the system:
•Slowly open the Feed Water Saddle Valve
fully counter clockwise.
•The Holding Tank Valve should be open.
•Check the Air Gap Window on the
Dispensing Faucet to be sure that the drain
water is owing. The R.O. System is now
making water.
•Do not open the Faucet for at least 8 hours.
•Do not use the rst three full tanks of water.
CAUTION: The R.O. Membrane is shipped
with a preservative in it. To ensure proper rinsing of the R.O. Membrane it is important to wait at least 8 hours before emptying each tank.
10
Page 11
When the Faucet is rst opened, expect air
and carbon nes (very ne black powder)
from the In–Line Activated Carbon Post Filter to be rinsed out. This is normal for the
rst tank of water or after the In-line lter is
changed.
SECTION IV. OPERATION & MAINTENANCE
A.  Normal Operation 
1. It is normal for the Total Dissolved Solids (TDS) of the water to be higher than normal
during the rst 5 gallons of operation; this is
due to the sanitizing solution and the new Post Filters. After this water is rinsed to drain, the removal rate should stabilize at a value of greater than 75%.
2. R.O. systems produce drinking water at relatively slow rates; it can take up to 5 hours
or more to ll the Holding Tank. Normal operation is to let the Holding Tank ll with
water and then draw water as is needed. When the pressure in the Holding Tank falls to a given pressure (as the water is being used) the Automatic Shut–Off Valve (ASO Valve) will start water production and the
system will rell the Holding Tank. When the
Holding Tank is full and no water is being used, the ASO Valve will automatically shut off the feed water to conserve water. The more water that is used (up to the capacity of the system) the better the R.O. system will function. Other uses for the water are
owers, pets and rinsing glassware.
With each use it is recommended that you
run the faucet for at least 10 seconds prior to using water. This is especially important if the system has not been used daily. After periods of non–use, such as a week of vacation, it is better to empty the Holding Tank and allow the system to produce fresh water for use. If the system is not used for 3–4 weeks or longer, it is a good idea to resanitize the
system and to change the prelter and post lters.
B.  Changing Filters 
THIS R.O. SYSTEM CONTAINS FILTERS
WHICH MUST BE REPLACED AT REGULAR INTERVALS TO MAINTAIN PROPER PERFORMANCE. USE ONLY FACTORY APPROVED FILTERS.
All individuals should take adequate 
precautions when changing the lters,  including wearing protective gloves, to avoid  direct contact with the exhausted lters.
The recommended interval for changing the
lters (not the R.O. Membrane) is every 6 to 12 months. Typical T.F.C. Membrane life expectancy is three years. Local conditions may dictate more frequent changes.
NOTE: If the R.O. Membrane is to be replaced,
see Sec. III, F.1–3 for the proper procedure.
Use a drip pan to catch any water that may spill
when the Filter Housings are removed. Refer to Fig. 1 for component location.
1. Close the Feed Water Saddle Valve by turning fully clockwise and open the Dispensing Faucet. Allow the Holding Tank to empty.
2. Loosen and remove the Sediment Prelter and the Activated Carbon Prelter Housings. Discard the lters.
3. Wash the inside of the Housings using a mild detergent and a soft cloth. Do not use abrasive cleaners or pads. Thoroughly rinse all soap from the Housings before reassembly.
4. To sanitize the system and replace the lters:
NOTE: The system should be sanitized
before installing the Activated Carbon
Prelter.
•Use a good quality unscented 5¼% liquid
chlorine household bleach.
•Add one capful of bleach (this is 2 tsp. or
10 ml) to the Sediment Prelter Housing and install the Sediment Prelter. AVOID
GETTING BLEACH ON THREADS AND O-RINGS. Check the Housing O–ring for proper position in its groove, engage and
rmly tighten the Housing hand tight only.
•Add one capful of bleach to the Activated
Carbon Prelter Housing. AVOID GETTING
BLEACH ON THREADS AND O-RINGS. nstall the Housing without the Activated
Carbon Prelter.
11
Page 12
•The Dispensing Faucet should be open,
OUT
ed
C
arbon Post Filter
3/8
T
o
g
auce
3/8
slowly open the Feed Water Saddle Valve.
IN–LINE ACTIVATED CARBON
POST FILTER ASSEMBLY
•As soon as water begins to drip out of the
Dispensing Faucet, close the Faucet.
•Let the system stand for 15 minutes.
•At the end of 15 minutes, in the following
order, close the Feed Water Saddle Valve, close the Holding Tank Valve and open the Dispensing Faucet to release the pressure.
•Remove the Activated Carbon Prelter
Housing and empty. Remove the wrapping
and install the Activated Carbon Prelter.
Firmly tighten the Housing hand tight only.
•Disconnect the yellow product water tubing
that runs from the Holding Tank to the Tee (see Fig. 1). Put 50 drops of bleach (this is ½ tsp. or 3 ml) into the tubing and reconnect it to the Tee.
NOTE: Now is the convenient time to
change the In–Line Activated Carbon Post Filter, see Sec. IV, C.1–6.
•Slowly open the Feed Water Saddle Valve.
When water begins dripping out of the Dispensing Faucet, in the following order, close the Faucet and then open the Holding Tank Valve.
•Do not open the Faucet for at least 8 hours.
•Discard the rst three full tanks of water
produced, they will contain chlorine.
Dispensin
t
" Blue
" Blue
In-Line Activat
Figure 5
C.  Changing the In–Line Activated Carbon Post 
Filter
1. Close the Feed Water Saddle Valve by turning fully clockwise.
2. Close the Holding Tank Valve and then open the Dispensing Faucet to release the pressure.
3. Remove the In–Line Activated Carbon Post Filter. Disconnect the used Post Filter by
pressing in the connector’s collar and at the same time pulling the tube out of the tting.
4. Firmly reconnect the polytubes to the new Post Filter. (Refer to Fig. 5) Make sure the tubing is pressed all the way in to create a pressure tight connection.
NOTE: If you want to pull the tubing out for some
reason, push the ring around the tubing in and pull the tubing out.
5. Slowly open the Feed Water Saddle Valve.
6. When water begins dripping out of the Faucet, in the following order, close the Faucet and open the Holding Tank Valve.
When the Faucet is rst opened, expect air and carbon nes (very ne black powder),
from the new Post Filter to be rinsed out. This
is normal for the rst tank of water.
12
Page 13
NOTES:
13
Page 14
NOTES:
14
Page 15
NOTES:
15
Page 16
SECTION V. TROUBLE SHOOTING GUIDE
Problem Possible Cause Solution
Low quantity of Product Water  from Holding Tank
Low pressure at the Dispensing  Faucet
Feed Water Saddle Valve is plugged or closed.
Clogged Sediment Prelter or Activated Carbon Prelter.
Low water pressure Feed Water pressure must be above
R.O. Membrane is fouled. See Feed Water operating limits.
Plugged In–Line Activated Carbon Post Filter. Air precharge pressure in Holding Tank is too high. Air precharge is too low. Air bladder in the Holding Tank is ruptured. Holding Tank Valve is closed. Open Valve.
No drain ow, the Drain Restrictor is
plugged.
No drain ow, the drain orice in the
Dispensing Faucet is plugged. The Check Valve is stuck. Free check. The ASO Valve is malfunctioning. Replace ASO Valve components. In-Line Activated Carbon Post Filter is plugged. Air precharge in the Holding Tank is too low.
Holding Tank Valve is partially closed. Open Valve.
Open Valve or unclog.
Replace lters.
40 psig.
Correct cause of fouling, replace Membrane. Replace Post Filter.
Empty water from Holding Tank, and with the faucet open, adjust air pressure to 5–7 psig (35–48 kPa) range. Replace tank.
Clear or replace Drain Restrictor.
Clear or replace the Dispensing Faucet.
Replace Post Filter.
Empty water from Holding Tank and with the faucet open, adjust the air pressure to 5–7 psig (35–48 kPa) range. Check for leakage at the Air Valve Stem.
High Total Dissolved Solids (TDS) in  the Product Water
The Dispensing Faucet is out of adjustment or faulty. Heavy water use, Holding Tank is depleted.
Low Water Production. See Low Quantity of Product Water
Clogged Sediment Prelter or Activated Carbon Prelter.
Low Water Pressure. Feed Water Pressure must be above
R.O. Membrane O–ring is crimped. Check O–ring. R.O. Membrane brine seal is not sealing up into the manifold head. R.O. Membrane is expended. If Membrane life is unusually short,
16
Repair or replace Dispensing Faucet.
Allow Holding Tank to rell (adding a
second Holding Tank will increase storage capacity).
from Holding Tank section above Replace Filters.
40 psig.
Check Feed Water Saddle Valve.
Check the brine seal.
nd and correct the problem. Replace Membrane.
Page 17
Problem Possible Cause Solution
High Total Dissolved Solids (TDS) in  the Product Water (continued)
Tastes and odors in the Product Water The In-Line or Activated Carbon
Drain Water overows at the  Dispensing Faucet
Faucet leaks or drips Leaks from base of the delivery
Fitting leaks in general Close the Feed Water Saddle Valve and relieve pressure before disconnecting
The Product Water and Drain Water lines are reversed.
No drain ow, Drain Restrictor is
clogged. No drain ow, the drain orice in the Dispensing Faucet is plugged. The ASO Valve is not closing. Repair or replace the ASO Valve
New In-Line or Activated Carbon
Prelter not rinsed completely.
The Feed Water TDS has increased. An increase in Feed Water TDS will
Prelter is exhausted.
There is foreign matter in the Holding Tank. The Product Water and Drain Water lines are reversed. Dissolved gasses in the Feed Water. Pretreat Feed Water to remove
Increase in Product Water TDS. See high TDS in the Product Water
Air Gap is blocked. Clear Air Gap.
Drain tubing is clogged. Clear tubing. Drain Clamp hole is misaligned. Align with hole in the drain pipe. Excessive drain ow rate. Replace Drain Restrictor.
tube.
any tubing or replacing any tting. Before replacing a tting, re–cut the tubing and re–insert into the tting to see if that solves the leak. If pipe threads are leaking, remove and retape with Teon tape.
Correct plumbing.
Clear or replace Drain Restrictor.
Clear or replace Dispensing Faucet.
Components. Flush with several full tanks of Product Water.
give a corresponding increase in Product Water TDS. Replace Filters.
Clean, ush and sanitize the system. Replace the lters.
Correct plumbing.
dissolved gasses.
section.
Rinse with vinegar for removal of calcium buildup.
O–ring is bad, replace O–ring.
17
Page 18
MADE IN USA
EXPLODED VIEW & PARTS LIST
1
2
3 4 5 6
7
8
9 10
11
18
15
17
12
16
13
14
18
Page 19
OUT
IN
19
DRAWING NO. PART NO. DESCRIPTION
1 .................... S2009 ................................ Self Tapping Screw
2 .................... S2005-01........................... ASO Cap
3 .................... S2013 ................................ ASO Cap O–Ring
4 .................... S2011 ................................ ASO Diaphragm – Large
5 .................... S2007-01........................... ASO Piston
6 .................... S2006-01........................... ASO Piston Ring
7 .................... S2010 ................................ ASO Diaphragm – Small
8 .................... NSTFC0405NGPP ............ Manifold Plate Assembly
(Includes diagram numbers 1 through 10 & 15)
9 .................... S1276 ................................ Check Valve
10 .................... S1277 ................................ Check Valve Retainer
11 .................... S7011 ................................ Sediment Prelter
12 .................... S7028 ................................ Activated Carbon Prelter
13 .................... S3069 ................................ Housing O–Ring
14 .................... S7029-09........................... Housing
15 .................... S2116–5 ............................ Drain Restrictor 50 GPD/189 lpd
16 .................... S1764RS ........................... T.F.C. RO Membrane 50 gpd/189 lpd
17 .................... S1405 ................................ 1/4"–3/8" Fitting Wrench
18 .................... S3072 ................................ Wrench for Housing
19 .................... S7206W-JG ....................... In–Line Activated Carbon Post Filter
OTHER COMPONENTS AS SHOWN IN FIGURE 1, PAGE 3.
DRAWING NO. PART NO. DESCRIPTION
1 .................... R7100-CR ......................... Dispensing Faucet
2 .................... S1117–01 .......................... 3/8" Drain Clamp Assembly
4 .................... JG-PI301208S................... 3/8" x 3/8" x 1/4" Union Tee
5 .................... S1118–01 .......................... Feed Water Saddle Valve
6 .................... C2000F ............................. Holding Tank
7 .................... JG-PPSV501222W ........... Holding Tank Shut–Off Valve
19
Page 20
R.O. DRINKING WATER SYSTEM
FIVE/ONE YEAR LIMITED WARRANTY
What Does This Warranty Cover? This warranty covers any defects in materials and workmanship of the R.O. Drinking Water System when installed and operated within recommended parameters, with the exceptions stated below.
How Long Does The Coverage Last? The manufacturer will warrant its R.O. Drinking Water System (except for the reverse osmosis membrane), for a period of ve years from the date of purchase. The reverse osmosis membrane is warranted for one year from date of purchase. All implied warranties including merchantability and tness for a particular purpose are limited to ve years from the date of purchase for the R.O. Drinking Water System, except for the reverse osmosis membrane which is limited to one year from date of purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
What Will The Manufacturer Do? The manufacturer will repair or replace at its discretion any defective component. You must pay any labor charges. You must also pay for shipping or travel charges to return the defective part(s).
What Does This Warranty Not Cover? This warranty does not cover the disposable sediment and carbon lters whose service life depends on feed water conditions. In addition, the membrane is only warranted if the required feed water conditions are met.
The above warranty will also not apply to any part of the R.O. Drinking Water System that is damaged because of neglect, misuse, alterations, accident, misapplication, physical damage, or damage caused by re, acts of God, freezing or hot waters or similar causes. Consequential and incidental damages are not recoverable under this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
We recommend that you use only the manufacturer's replacement parts since improper parts or incorrectly performed maintenance or repair voids this warranty.
How Do You Get Service? In order to be eligible for service under this warranty you must (a) contact your local dealer who supplied the unit.
How Does State Law Apply? This warranty gives you specic legal rights and you may also have other rights which vary from state to state.
Your Water Treatment Professional:
Form No. S1462-04 4/11/2012
Loading...