
User manual
User manual
Page 1
Fix the timer to a wall in a covered location, sheltered from weather and splashing water; ambient temperature
between 0 and 50 °C. Do not install the timer outdoors or in underground valve box.
For Multipla AC 230/24V LCD (p/n): 8058
Multipla AC LCD
Multipla AC LCD
Electrical connections.
For Multipla AC 230/24V LCD (p/n): 8058
1
1
2
2
3
3
a
a
c
c
d
d
f
f
e
e
6mm
6mm
TSP 4x30
b
b
c
c
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
30
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
START + ...
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
a
a
a
a
b
b
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10 30
20
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10 30
20
OK!
NO!
min. 0°C
max. 50°C
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10 30
20
9Volt
ALCALINA
MULTIPLA AC 230/24V
Common
junction box
MV
1
2
3
4
5
6
RS
Jumper
24AC
Grommet
Line valves
Rain
Sensor
(optional)
1 2 3 4 5 6
max 50 m (cross section 1.5 mm
2
)
Claber
relay
B
Relè
Claber
to pump
220 V
A

Page 2
Ret the battery cover. Plug the voltage transformer into a 230 V AC mains power socket. The battery serves
purely to maintain the clock function, and therefore the timing of the selected programme, in the event of a
mains power failure.
For Multipla AC 230/24V LCD (p/n): 8058
Multipla AC LCD
Multipla AC LCD
Remove the cover of the battery pocket from its seat, connect the battery and position it in the pocket, with a
light pressure. Use only a new 9 volt alkaline battery, type IEC 6LR61. When the battery is inserted, the message
OFF will be displayed.
For Multipla AC 230/24V LCD (p/n): 8058
User manual
User manual
1
1
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
1
1
2
2
3
3
a
a
a
a
a
a
a
a
b
b
b
b
b
b
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
9 V
Alcaline
click!
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20

Page 3
During a watering cycle, the Multipla activates all the valves on lines 1 to 6 for which a watering time has been
programmed using the LINE SELECTORS, opening them in succession and in ascending order. A watering
programme consists in the repetition of a watering cycle at intervals programmed with the FREQUENCY selector. Having decided which lines are to be activated, turn the LINE selector for each one until it is positioned on
the required time. Watering can be programmed for a duration between 5 and 60 minutes. To exclude watering
on a given line, position the corresponding selector on • (zero).
For Multipla AC 230/24V LCD (p/n): 8058
Multipla AC LCD
Multipla AC LCD
The test function can be used to perform a quick check on the system that will ensure its correct operation, by
activating a given valve manually for a preset duration of 5 minutes. If there is a watering cycle in progress, it can
be interrupted by pressing TEST and START+… . Press the TEST button repeatedly to select and activate one of
the lines; after a few seconds, the relative valve will open for 5 minutes. The display indicates the operating mode
- “TEST” - the line selected, and the time remaining. To close the valve being tested before the end of the 5 minutes, press TEST and START+... simultaneously.
For Multipla AC 230/24V LCD (p/n): 8058
User manual
User manual
1
1
2
2
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
led-valve 1 ... ...
led-valve 2 ... ...
led-valve 3 ... ...
led-valve 4 ... ...
led-valve 5 ... ...
led-valve 6 ... ...
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
Test
START + ...
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
30
20
60
5
10
15
30
20
60
5
10
15
30
20
Test
START + ...
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
30
60
5
10
15
30
20
Test
START + ...
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
Line 3
5
10
15 20
30
60
20 min.
5 min.
1
1
2
2
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
TEST!
1...6
60
10
15
30
20
60
5
10
15
30
20
60
5
10
30
20
x 3
LINE
MIN
TEST
1...6
5 min.

Page 4
To start the programme immediately, press START+…once. The next watering cycle will begin after the time period set with
the FREQUENCY selector has elapsed (example: pressing the START+... button at 20:00 to activate the programme, with the
FREQUENCY set at 8 hours, the next watering cycle will start at 04:00).
For Multipla AC 230/24V LCD (p/n): 8058
Multipla AC LCD
Multipla AC LCD
To set the watering frequency, turn the FREQUENCY selector to the required position (every 8, 12 or 24 hours, or
2, 3, 4 or 7 days)
For Multipla AC 230/24V LCD (p/n): 8058
User manual
User manual
1
1
Start
LINE
MIN
30
20
60
5
10
15
30
20
60
5
10
30
20
x 1
1
1
30
12
1
2
3
4
5
6
7
8
9
10
11
28
29

Page 5
When a watering cycle is in progress, the display shows the ongoing symbol, the number of the line currently active and
the number of minutes remaining until watering is due to nish on that line. The valve currently open is also indicated by
the relative Led, which blinks. Once completed the watering cycle, the standby signal reappears in the display, with the
time remaining until the start of the next watering cycle (example of watering cycle with FREQUENCY selector set to 8h).
For Multipla AC 230/24V LCD (p/n): 8058
Multipla AC LCD
Multipla AC LCD
To delay the start of the programme, press START+… a second time before 5 seconds have elapsed, to set a delay
of one hour, a third time for two hours, and so on up to 23 hours. The display temporarily indicates the number
of hours delay selected, then the watering standby signal appears, along with the time remaining until the start
of the rst cycle.
For Multipla AC 230/24V LCD (p/n): 8058
User manual
User manual
1
1
2
2
LINE
MIN
LINE
MIN
HOUR MIN
led-valve 1
Example of watering cycle with FREQUENCY selector set to 8h
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
TEST/MANUAL
MULTIPLA AC 230/24V LCD
START + ...HOURS
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
15
30
20
60
5
10
15
30
20
60
5
10
30
20
60
15
30
20
60
5
10
15
30
20
60
5
10
30
20
x 1
+
x 7
HOUR MIN
1...23

Page 6
To change a watering programme currently in use, enter the new LINE and FREQUENCY settings as required.
The change will be eective by the timer when appropriate.
Examples: - with watering in progress and line 2 active, the position of the LINE selectors is changed (e.g., from 10 min to 20 min): there will be no
change on the duration of the watering step already in progress on line 2, whereas the new setting of 20 minutes will be eective with the activation of line 3.
- changing the position of the FREQUENCY selector (say, from 8 to 12 hours): the new setting will take eect within 24 hours subsequent to the
change being made; thereafter, the watering cycles will be repeated at the new frequency selected, whilst the START time remains unchanged.
For Multipla AC 230/24V LCD (p/n): 8058
Multipla AC LCD
Multipla AC LCD
Example of programming: at 16:30, the duration is selected for all of the watering lines (LINE selectors) and the
frequency is set at 8h (FREQUENCY selector). Suppose that watering is not required immediately, but at 22:30
(i.e. after 6 hours): press the START+… button once, and then six times in succession, so that the display shows
6:00. The time indicated in the display begins counting down, reaching 0:00 at 22:30; the watering cycle starts,
and will then be repeated every 8 hours as set with the FREQUENCY selector (i.e. at 22.30, at 06:30 and at 14:30).
For Multipla AC 230/24V LCD (p/n): 8058
User manual
User manual
1
1
2
2
3
3
LINE
MIN
from 10 min to 20 min
LINE
MIN
LINE
MIN
from 10 min to 20 min
from 8h to 12h
24h
HOUR MIN
Frequency
a
a
a
a
a
a
c
c
b
b
b
b
b
b
60
30
20
60
5
10
15
30
20
60
5
10
15
30
20
Test
START + ...
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
30
20
60
5
10
15
30
20
60
5
10
15
30
20
Test
START + ...
RESET
60
5
10
15
30
20
7d
FREQUENCY
12h
8h
24h
2d
4d
3d
60
5
10
15
30
20
60
5
10
30
20
60
5
10
15
30
20
60
5
10
15
30
20
60
5
10
15
30
20
5
16:30
16:30
22:30
22:30
HOUR MIN
HOUR MIN
Frequency
16:30
16:30
START
60
10
15
30
20
60
5
10
30
20
60
10
15
30
20
60
5
10
30
20
8 h
a
a
a
a
a
a
b
b
b
b
6:30
b
b
c
c

Page 7
The RESET function closes the valve, if currently open, and switches the timer OFF. Watering will be suspended
until the START+... button is pressed again, or until a TEST is run. To RESET the timer, press the START and
START+… buttons simultaneously and hold them for 5 seconds. The message OFF appears in the display.
For Multipla AC 230/24V LCD (p/n): 8058
Multipla AC LCD
Multipla AC LCD
The STOP function interrupts the watering cycle currently in progress. Watering will restart as normal with eect
from the cycle following the selected pause, as programmed by positioning the FREQUENCY selector.
The STOP function can also be used to close a valve manually, when activated in TEST mode.
For Multipla AC 230/24V LCD (p/n): 8058
For more information and further details, please consult the instruction manual supplied with the product.
User manual
User manual
1
1
60
10
15
30
20
60
5
10
15
30
20
60
5
10
30
20
30
20
60
10
15
30
20
60
5
10
15
30
20
60
5
10
30
20