Civacon ROM II Troubleshooting Manual

Civacon World Headquarters:
4304 Mattox Road Riverside, MO 64150
816/741-6600 Fax: 816/741-1061 www.civacon.com
Technical Support Hotline:
©2002 Civacon CK-00107 • FMI1K4/02 • H52402PA
Civacon
ROM II
Troubleshooting Guide
$5
00 US
Other Components:
A
B
FIGURE 1
A) Retain Jumper B) Auxiliary Inputs Jumper
Terminator
Optic Sensor
Optic System Tester
100 SW
Air Interlock
Switch
ST ATUS: Ready to Load
ST ATUS: No LED/Lights lit ACTION: Check incoming voltage at Terminal
Block (TBI). Voltage should be between 11-16 volts. Check the 1/4 amp inline fuse and make sure it hasn’t blown. Replace monitor if fuse checks out as good.
ST ATUS: Yellow power LED/Light lit, but no
permit light
ACTION: Check Auxiliary (AUX) connections.
All three auxiliary lights must be on/lit to get a permit light. If no auxiliary inputs are being used, a jumper must be installed (see OTHER COMPONENTS).
ST ATUS: Solid red LED/Light on top sensor ACTION: Check compartment for wet sensor.
Remove sensor wire corresponding with LED. Substitute with wire from nearest working sensor. If the LED remains lit, replace monitor. If the LED corresponding to the substituted wire is lit, replace the sensor or check wiring.
ST ATUS: Flashing red LED/Light in top sensor ACTION: Remove sensor wire corresponding with
the flashing LED. Substitute with a working sensor. If the same LED continues to flash, replace monitor. If flashing LED changes to the location of the sub­stituted wire, check the wiring or replace the sensor.
ST ATUS: Flashing red top sensor LED/Light in
compartment 6 on a 5 or less compartment trailer
ACTION: Check wiring at the terminator. If
connections are good, replace terminator.
ST ATUS: All top red LED/Lights are flashing ACTION: Check common wire. Check for
low voltage at Terminal Block (TBI).
ST ATUS: Solid red
LED/Light on bottom sensor.
ACTION: Check
compartment for product. Hit blue Retain/Reset Button to see if condition clears. If condition persists, repeat action from #4.
ST ATUS: Flashing red LED/Light on
bottom sensor.
ACTION: Check compartment for
product. Hit Retain/Reset Button to see if light clears. Check wiring connections.
1
2
3
6
5
4
7
9
8
Loading...