070707 Page 1 of 3 Copyright 2007 Citel plc All Rights Reserved
EXTender 3000u Error Codes
To view these errors:
1. Access the Go Online? Menu
2. Press 3 (NEXT) until Diagnostics Menu? Press 2 (OK)
3. Press 3 (NEXT) until you see View RMT Stats or View Office (SWT) Stats, Press 2 (OK)
4. Scroll through and write down the number of times each error has occurred. Eg. 104A:1288
5. These errors will point out if problem is with the Office or Remote telco circuit or with hardware
ERROR
CODE
DESCRIPTION EXPLANATION
101A
Number of received ISDN Voice
packets that contained a CRC
error.
Occurs on old ISDN only.
102A
Number of received ISDN TCM
Signaling packets that contained
a CRC error.
Occurs on old ISDN only.
103A
Number of received ISDN User
Data packets that contained a
CRC error.
Occurs on old ISDN only.
104A
Number of received ISDN
Packets that contained an Invalid
V42 Address.
Received HDLC packet that was not
ADPCM, Signaling or User Data. Should
not occur on current code. Would need
further investigation by MCK.
105A
Number of rejected MCK or
phone signaling packets received
because they were out of
sequence.
Far end rejected signaling packet. Might
occur often. Should not cause a
significant functional problem.
106B
Number of times MCK or phone
signaling packet re-transmissions
exceeded maximum (Causes
Digital Port Data to be lost).
A packet of signaling data was sent with
no acknowledgement. After 5 tries this
error is incremented.
107B
Number of times MCK or phone
signaling channel had to be resynchronized.
There was a request to re-synchronize
signaling channel from far end because
there was no acknowledgement.
Excessive errors would indicate a
problem with data delivery in the ISDN
network.

070707 Page 2 of 3 Copyright 2007 Citel plc All Rights Reserved
108B
Number of times MCK or phone
signaling channel had no data for
16 consecutive seconds.
Indicates that no data has been received
for 16 sec. MCK always sends a keep
alive every 8 sec. so this error would
indicate data is not getting through the
ISDN network.
109A
Number of times MCK or phone
signaling channel timed out
waiting for packet
acknowledgment.
Did not get a V42 signaling
acknowledgement. As long as you are not
getting 106B errors, this is not necessarily
a problem. Excessive errors or 106B
errors indicate a problem with the ISDN
line.
110C
Number of times MCK or phone
signaling channel transmit locked
up (transmit buffers full when no
data to send).
The 8 second TX timer timed out and
buffers were full. This should not occur.
Needs further investigation by MCK.
111A
Number of rejected serial data
packets received because they
were out of sequence.
Same as ‘105A’ except this is Serial Data.
112B
Number of times serial data
packet re-transmissions exceeded
maximum (Causes serial data to
be lost).
Same as ‘106B’ except this is Serial Data.
113B
Number of times serial data
channel had to be resynchronized.
Same as ‘107B’ except this is Serial Data.
114A
Number of times serial data
channel timed out waiting for
packet acknowledgment.
Same as ‘109A’ except this is Serial Data.
116B
Number of times carrier detect
lost from ISDN termination.
ISDN call was lost or far end
disconnected because of errors. May be
an ISDN problem or problem with unit on
far end. ISDN problems should have
other errors accompanying this one.
117C
Number of times Terminal
Adapter check failed.
Occurs on old ISDN only.
118C
Number of times communications
to DSP failed.
Contact MCK. Should never occur.
119B
Number of times Digital port link
re-activated.
Digital port or phone was disconnected.
Check wiring. However, using the TTI
feature could cause these errors under
normal operation.
120B
Number of times Digital port
connection was lost or deactivated.
Contact MCK. Should never occur.
121A Number of times Digital port data
was re-transmitted.
Contact MCK. Should never occur.

070707 Page 3 of 3 Copyright 2007 Citel plc All Rights Reserved
122B
Number of times IVP (V42) link
failed.
Could be the wrong ‘Connect Rate’ or the
V42 process failed. Problem with ISDN
network or connect rate between units.
123A
Number of times User
disconnected by pressing HOLD
key 4 times and then
disconnecting.
The user pressed the HOLD key four
times and disconnected. Normal
Operation.
124C
Number of times Synchronous
Communications Controller IC
transmit locked up.
Occurs on old ISDN only.
125B
Number of fatal errors that caused
unit to restart (caused by errors
124C, 118C, and 120B).
Occurs on old ISDN only.
126C
Invalid length of SCC Tx packet Contact MCK. Should never occur.
127B
SCC Transmit Busy Contact MCK. Should never occur.
128A
SCC Rx Status Error Received a bad packet. Excessive errors
could affect voice quality. Usually
network related.
129A
SCC Tx Status Error Contact MCK. Should never occur.
130A
Invalid Voice Packet ID detected Not used.
131A
Number of times all Serial Data
buffers were in use
132A
Number of times Serial Data
packets too long
133A
Number of times all MCK or
phone signaling buffers were in
use
Contact MCK. Should never occur.
134A
Number of times MCK or phone
signaling packets too long
Contact MCK. Should never occur.
139A
PBX ISDN Connect failed Switch could not establish an ISDN
connection. Problems with ISDN service.
140A
RMT ISDN Connect failed Remote could not establish an ISDN
connection. Problem with ISDN service.
141B
V42 Connect Failed
The V42 Connect Process failed.
Problem with ISDN service.
144X
144 not available at this time N/A
Note:
When a user is receiving functional errors with their EXTender 3000 units, it is important to
check for the presence of these errors. If they are receiving serious functional errors and there
are no applicable error codes, the problem may be with the EXTenders themselves.
Functional errors should always produce a cause that would be indicated through the error
codes above.
For Further Assistance, Please Contact Citel Technical Support @ 1-877-248-3587