Citel EXTender 3000, EXTender 3000u Code Manual

070707 Page 1 of 3  Copyright 2007 Citel plc All Rights Reserved
EXTender 3000u Error Codes
To view these errors:
1. Access the Go Online? Menu
2. Press 3 (NEXT) until Diagnostics Menu? Press 2 (OK)
3. Press 3 (NEXT) until you see View RMT Stats or View Office (SWT) Stats, Press 2 (OK)
4. Scroll through and write down the number of times each error has occurred. Eg. 104A:1288
5. These errors will point out if problem is with the Office or Remote telco circuit or with hardware
ERROR
CODE
DESCRIPTION EXPLANATION
101A
Number of received ISDN Voice packets that contained a CRC error.
Occurs on old ISDN only.
102A
Number of received ISDN TCM Signaling packets that contained a CRC error.
Occurs on old ISDN only.
103A
Number of received ISDN User Data packets that contained a CRC error.
Occurs on old ISDN only.
104A
Number of received ISDN Packets that contained an Invalid V42 Address.
Received HDLC packet that was not ADPCM, Signaling or User Data. Should not occur on current code. Would need further investigation by MCK.
105A
Number of rejected MCK or phone signaling packets received because they were out of sequence.
Far end rejected signaling packet. Might occur often. Should not cause a significant functional problem.
106B
Number of times MCK or phone signaling packet re-transmissions exceeded maximum (Causes Digital Port Data to be lost).
A packet of signaling data was sent with no acknowledgement. After 5 tries this error is incremented.
107B
Number of times MCK or phone signaling channel had to be re­synchronized.
There was a request to re-synchronize signaling channel from far end because
there was no acknowledgement.
Excessive errors would indicate a problem with data delivery in the ISDN network.
070707 Page 2 of 3  Copyright 2007 Citel plc All Rights Reserved
108B
Number of times MCK or phone signaling channel had no data for 16 consecutive seconds.
Indicates that no data has been received for 16 sec. MCK always sends a keep alive every 8 sec. so this error would indicate data is not getting through the ISDN network.
109A
Number of times MCK or phone signaling channel timed out waiting for packet acknowledgment.
Did not get a V42 signaling acknowledgement. As long as you are not getting 106B errors, this is not necessarily a problem. Excessive errors or 106B errors indicate a problem with the ISDN line.
110C
Number of times MCK or phone signaling channel transmit locked up (transmit buffers full when no data to send).
The 8 second TX timer timed out and
buffers were full. This should not occur.
Needs further investigation by MCK.
111A
Number of rejected serial data packets received because they were out of sequence.
Same as ‘105A’ except this is Serial Data.
112B
Number of times serial data packet re-transmissions exceeded maximum (Causes serial data to be lost).
Same as ‘106B’ except this is Serial Data.
113B
Number of times serial data channel had to be re­synchronized.
Same as ‘107B’ except this is Serial Data.
114A
Number of times serial data channel timed out waiting for packet acknowledgment.
Same as ‘109A’ except this is Serial Data.
116B
Number of times carrier detect lost from ISDN termination.
ISDN call was lost or far end disconnected because of errors. May be an ISDN problem or problem with unit on far end. ISDN problems should have other errors accompanying this one.
117C
Number of times Terminal Adapter check failed.
Occurs on old ISDN only.
118C
Number of times communications to DSP failed.
Contact MCK. Should never occur.
119B
Number of times Digital port link re-activated.
Digital port or phone was disconnected.
Check wiring. However, using the TTI feature could cause these errors under normal operation.
120B
Number of times Digital port connection was lost or de­activated.
Contact MCK. Should never occur.
121A Number of times Digital port data
was re-transmitted.
Contact MCK. Should never occur.
070707 Page 3 of 3  Copyright 2007 Citel plc All Rights Reserved
122B
Number of times IVP (V42) link failed.
Could be the wrong ‘Connect Rate’ or the V42 process failed. Problem with ISDN network or connect rate between units.
123A
Number of times User disconnected by pressing HOLD key 4 times and then disconnecting.
The user pressed the HOLD key four times and disconnected. Normal Operation.
124C
Number of times Synchronous Communications Controller IC transmit locked up.
Occurs on old ISDN only.
125B
Number of fatal errors that caused unit to restart (caused by errors 124C, 118C, and 120B).
Occurs on old ISDN only.
126C
Invalid length of SCC Tx packet Contact MCK. Should never occur.
127B
SCC Transmit Busy Contact MCK. Should never occur.
128A
SCC Rx Status Error Received a bad packet. Excessive errors
could affect voice quality. Usually network related.
129A
SCC Tx Status Error Contact MCK. Should never occur.
130A
Invalid Voice Packet ID detected Not used.
131A
Number of times all Serial Data buffers were in use
132A
Number of times Serial Data packets too long
133A
Number of times all MCK or phone signaling buffers were in use
Contact MCK. Should never occur.
134A
Number of times MCK or phone signaling packets too long
Contact MCK. Should never occur.
139A
PBX ISDN Connect failed Switch could not establish an ISDN
connection. Problems with ISDN service.
140A
RMT ISDN Connect failed Remote could not establish an ISDN
connection. Problem with ISDN service.
141B
V42 Connect Failed
The V42 Connect Process failed.
Problem with ISDN service.
144X
144 not available at this time N/A
Note:
When a user is receiving functional errors with their EXTender 3000 units, it is important to check for the presence of these errors. If they are receiving serious functional errors and there are no applicable error codes, the problem may be with the EXTenders themselves. Functional errors should always produce a cause that would be indicated through the error codes above.
For Further Assistance, Please Contact Citel Technical Support @ 1-877-248-3587