Cisco UCS C460 M2 User Manual

Page 1
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Spec Sheet
CISCO SYSTEMS PUBLICATION HISTORY
170 W
EST TASMAN DR.
S
AN JOSE, CA, 95134 REV B.6 SEPTEMBER 6, 2013
WWW.CISCO.COM
Page 2
CONTENTS
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 7
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
STEP 1 VERIFY BASE SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
STEP 2 CHOOSE CPU(S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
STEP 3 CHOOSE MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs . . . . . . . . . . . . . . . . . . . . . . 18
STEP 5 CHOOSE RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
STEP 6 CHOOSE PCIe OPTION CARD(S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 26
STEP 8 ORDER POWER SUPPLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
STEP 9 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
STEP 10 ORDER OPTIONAL SLIDE RAIL KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
STEP 11 ORDER OPTIONAL CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . . . . . . . . . . 34
STEP 12 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE . . . . . . . . . . . . . . . . . . . . . . . . 35
STEP 13 ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
STEP 14 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . 37
STEP 15 CHOOSE OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
STEP 16 CHOOSE SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
OPTIONAL STEP - ORDER RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Cisco UCS C460 M2 High-Performance Rack-Mount Server
2
Page 3
OVERVIEW
Front View
Rear View
OVERVIEW
The Cisco UCS C460 M2 High-Performance Rack Server (Figure 1) is a four-rack-unit (4RU) server supporting
the Intel® Xeon® processor E7-4800 and E7-8800 product families, with up to 2 terabytes (TB) of double-data-rate 3 (DDR3) memory in 64 slots, and up to 12 small form factor (SFF), hot-pluggable SAS and SATA disk drives.
10 PCI Express (PCIe) slots support the Cisco UCS C-Series network adapters, with an eleventh PCIe slot reserved for a hard disk drive array controller card. Additional I/O is provided by 2 Gigabit Ethernet LOM ports, 2 10-Gigabit Ethernet ports, and 2 dedicated out-of-band (OOB) management ports.
Figure 1 Cisco UCS C460 M2 High-Density Rack Server
Cisco UCS C460 M2 High-Performance Rack-Mount Server
3
Page 4
DETAILED VIEWS
198383
DETAILED VIEWS
Chassis Front View
Figure 2 is a detailed front view of the Cisco UCS C460 M2 General-Purpose Rack Server.
Figure 2 Chassis Front View
3
2
1
1 HDDs (up to 12) 6 CPU status LED 2 SATA DVD drive 7 Network activity LED
8 9 104 5 6 7
3 Fans (up to 8) 8 Operations panel (see Figure 3 on page 5 for a
4 Power supply status LED 9 VGA connector 5 Memory status LED 10 USB ports (3)
Figure 3 is a detailed view of operator panel.
4
detailed view)
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 5
Figure 3 Chassis Front View
12 7
8
9
35
197617
4 6
1 ID LED 6 Power status LED 2 ID button 7 Power button 3 HDD fault LED 8 Reset button 4 System health LED 9 NMI button
DETAILED VIEWS
5 Fan fault LED
Cisco UCS C460 M2 High-Performance Rack-Mount Server
5
Page 6
DETAILED VIEWS
Chassis Rear View
Figure 4 shows the external features of the rear panel.
Figure 4 Chassis Rear View
7
8
9
10
11
12
6
5
4
3
2
1
1 Power supplies (up to 4) 7 10G SFP+ LOM ports, two total 2 ID button 8 1 Gigabit LOM ports (2 total)
198384
3 USB ports (2 total) 9 10/100 Management ports M1 and M2 4 VGA connector 10 Serial connector 5 10GBase-T LOM ports, two total 11 PCIe slots 1 through 10 (left to right as
shown)
6 SAS riser slot 12 Power supply LEDs
6
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 7
BASE SERVER STANDARD CAPABILITIES and FEATURES
NOTE: CPU3 must be installed to support PCIe slots 5, 6, 7, 9, and
10. Legacy I/O devices like video cards are only supported on slots 1,2,3, 4 and 8.
BASE SERVER STANDARD CAPABILITIES and FEATURES
Table 1 lists the capabilities and features of the base server. Details about how to configure the server for
a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in
Table 1 Capabilities and Features
Capability/Feature Description
Chassis Four rack unit (4RU) chassis
CPU Either 2 or 4 Intel® Xeon® E7-8800/4800 family processors
Chipset Intel® 7500 chipset and Intel 7510 scalable memory buffer
Memory Eight slots for memory riser boards. Each memory riser can hold up to 8
CONFIGURING the SERVER on page 10.
Two-CPU configurations require 2 power supplies
Four-CPU configurations require 4 power supplies
DIMMs, for a maximum DIMM population of 64 DIMMs.
Maximum memory capacity is 2 TB. This is accomplished with 64 DIMMs, consisting of 32 DIMM kits (2 32 GB matched DIMMs per kit) in a 4-CPU configuration.
USB Flash drive Optional 2 GB internal eUSB flash drives (up to 2) can be used as bootable
drives
Expansion slots There are 10 PCIe expansion slots:
Slots 1 and 2: Gen 2x8, 3/4 length card, x24 hot-swappable connectors
Slots 3 and 4: Gen 2x4, 1/2 length card, x8 connectors
Slot 5: Gen 2x16, 3/4 length card, x16 connector
Slots 6 and 7: Gen 2x8, 3/4 length card, x8 hot-swappable connectors
Slot 8: Gen 1x4, 3/4 length card, x8 connector
Slot 9: Gen 1x4, 1/2 length card, x8 connector
Slot 10: Gen 2x4, 1/2 length card, x8 connector
Cisco UCS C460 M2 High-Performance Rack-Mount Server
7
Page 8
BASE SERVER STANDARD CAPABILITIES and FEATURES
Table 1 Capabilities and Features (continued)
Capability/Feature Description
Storage controller Factory-configured RAID support options:
RAID 0, 1, 5, 6, 10, 50, and 60 support for up to 12 SAS or SATA drives
with either the optional LSI MegaRAID SAS 9260-8i controller, or
RAID 0 and 1 support for up to 8 SAS or SATA drives with the optional LSI
MegaRAID 9240-8I RAID controller.
There is a dedicated SAS riser slot in the chassis for either RAID controller card.
There is also a location inside the chassis for the optional LSI RAID battery backup unit that can be used with the 9260-8i controller card.
Internal storage devices Up to 12 SFF 2.5” SAS or SATA hard disk drives (HDDs) or solid state drives
(SSDs).
UCS Storage Accelerators are also available. These PCIe flash storage devices provide independent high-speed storage.
Video The server CIMC chip includes a Matrox G200 core. The first 8 MB of memory
are allocated to the video core.
1280 x 1024 resolution
32-bit color depth
8 MB video memory
Interfaces Rear panel
• Two 10/100 dedicated management Ethernet ports
• Two 1-Gigabit ports (10/100/1000 Mbps capable). These integrated Gigabit ports support the Wake on LAN (WoL) and TCP/IP Offload Engine (TOE) standards
• Two 10-Gigabit Base-T Ethernet ports
• Two 10-Gigabit SFP+ Ethernet ports
• One RS232 serial connector
• One 15-pin VGA connector
• Two USB 2.0 connectors
Front panel
• One 15-pin VGA connector
• Three USB 2.0 connectors
8
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 9
BASE SERVER STANDARD CAPABILITIES and FEATURES
NOTE: You can use 2 power supplies with a 2-CPU configuration. In
this case, 1+1 redundancy is supported only if your server’s overall power consumption can be supported by a single 850W power supply during the failure and hot-swap. For more information about your server’s power consumption, use the power calculator accessible at
http://www.cisco.com/assets/cdc_content_elements/flash/dataC enter/cisco_ucs_power_calculator/
Table 1 Capabilities and Features (continued)
Capability/Feature Description
Power subsystem Either 2 or 4 850 W power supplies
Power supplies are hot-swappable, rear-accessible, and redundant as
2+2 or 3+1
Fans Chassis:
8 fans, hot-swappable
Power supply:
Each of the 4 power supplies is equipped with a fan.
Integrated management processor
The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI interface enables you to monitor the server inventory, health, and system event logs.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
9
Page 10
CONFIGURING the SERVER
CONFIGURING the SER VER
Follow these steps to configure the Cisco UCS C460 M2 High-Performance Rack Server:
STEP 1 VERIFY BASE SKU, page 11
STEP 2 CHOOSE CPU(S), page 12
STEP 3 CHOOSE MEMORY, page 13
STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs, page 18
STEP 5 CHOOSE RAID CONFIGURATION, page 20
STEP 6 CHOOSE PCIe OPTION CARD(S), page 22
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 26
STEP 8 ORDER POWER SUPPLIES, page 29
STEP 9 SELECT AC POWER CORD(s), page 30
STEP 10 ORDER OPTIONAL SLIDE RAIL KIT, page 33
STEP 11 ORDER OPTIONAL CABLE MANAGEMENT ARM, page 34
STEP 12 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE, page 35
STEP 13 ORDER A TRUSTED PLATFORM MODULE, page 36
STEP 14 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 37
STEP 15 CHOOSE OPERATING SYSTEM MEDIA KIT, page 40
STEP 16 CHOOSE SERVICE and SUPPORT LEVEL, page 41
OPTIONAL STEP - ORDER RACKS on page 46
OPTIONAL STEP - ORDER PDU on page 47
10
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 11
STEP 1 VERIFY BASE SKU
Verify the product ID (PID) of the base server as shown in Table 2.
Table 2 PID of the Base C460 M2 Rack Server
Product ID (PID) Description
UCSC-BASE-M2-C460 UCS C460 M2 Rack SVR w/o CPU, Mem, HDD, PCIe
The base server:
Includes:
Two 850 W power supplies (required for 2-CPU systems)
Blanking panels for empty drive locations (to maintain cooling air flow)
Cable management arm
—Rail kit
Does not include:
CONFIGURING the SERVER
Third and fourth 850 W power supplies (required for 4-CPU systems)
—CPUs
Four empty memory riser boards (for 2-CPU systems) or 8 empty memory riser
boards (for 4-CPU systems)
Hard disk drives (HDDs)
Solid-state Drives (SSDs)
Plug-in PCIe cards.
NOTE: Use the steps on the following pages to configure the server with
the components that you want to include.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
11
Page 12
CONFIGURING the SERVER
STEP 2 CHOOSE CPU(S)
The standard CPU features are:
Intel Xeon E7-8800 or E7-4800 (Westmere EX) series CPUs
Intel 7500 chipset and Intel 7510 scalable memory buffer
Cache size of 18, 24, or 30 MB
Choose CPUs
The available CPUs are listed in Table 3.
Table 3 Available CPUs: Intel Xeon Westmere E7-48xx/88xx Family
Product ID (PID)
Intel
Number
Clock
Freq
(GHz)
Power
(W)
Cache
Size (MB)
Cores QPI
Highest DDR3
DIMM Clock
Support (MHz)
UCS-CPU-E78837 E7-8837 2.67 130 30 8 6.40 1066
UCS-CPU-E74870 E7-4870 2.40 130 30 10 6.40 1066
UCS-CPU-E74860 E7-4860 2.26 130 24 10 6.40 1066
UCS-CPU-E78867L E7-8867L 2.13 105 30 10 6.40 1066
UCS-CPU-E74830 E7-4830 2.13 105 24 8 6.40 1066
UCS-CPU-E74850 E7-4850 2.00 130 24 10 6.40 1066
UCS-CPU-E74807 E7-4807 1.86 95 18 6 4.80 1066
Approved Configurations
(1) Two-CPU Configuration
Choose two identical CPUs from Table 3.
(2) Four-CPU Configuration
Choose four identical CPUs from Table 3.
Caveats
You must select either two or four identical processors.
12
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 13
STEP 3 CHOOSE MEMORY
The standard memory features are:
Plug-In Memory Riser Boards
Up to eight DIMMs per riser board
Riser boards plug vertically into the motherboard
Up to two riser boards per CPU (total maximum of eight per system)
DIMMs
Clock speed: 1066 MHz
Ranks per DIMM: 1, 2, or 4
Operational voltage: 1.5 or 1.35 V
—Registered
Each CPU controls four serial memory interface (SMI) channels. Memory buffers on the
memory risers convert each SMI channel into two DDR3 subchannels. There are two memory risers for each CPU. Memory is organized as two paired-DIMM kits (4 DIMMs) per memory channel, as shown in
Figure 5.
CONFIGURING the SERVER
Cisco UCS C460 M2 High-Performance Rack-Mount Server
13
Page 14
CONFIGURING the SERVER
Figure 5 C460 M2 Memory Organization
14
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 15
CONFIGURING the SERVER
Choose Memory Riser Boards
You may choose four memory riser boards for a two-CPU system or eight memory riser boards for a four-CPU system.
Table 4 Available Memory Riser Boards
Product ID (PID) PID Description Max DIMMs per Riser
Riser Board Options
UCSC-MRB-002-C460 Memory riser board for C460 M2 server only 8
Approved Configurations
(1) Two-CPU System
Choose four memory riser boards from Table 4.
(1) Four-CPU System
Choose eight memory riser boards from Table 4.
Caveats
You should order enough risers with enough sockets to accommodate your maximum
forseeable memory needs.
Choose DIMMs and Memory Mirroring
Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in
Table 5.
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously
writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
15
Page 16
CONFIGURING the SERVER
DIMMs are orderable as kits, with two DIMMs per kit. Choose the desired number of DIMMs and the memory mirroring option if desired. The available memory DIMMs are listed in
Table 5 Available DDR3 DIMM Kits (2 DIMMs per Kit)
Table 5.
Product ID (PID) PID Description Voltage (V)
DIMM Options
UCS-MR-2X041RX-C 2X4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x4/1.35v 1.5/1.35 1
UCS-MR-2X082RX-C 2X8GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x2/1.35v 1.5/1.35 2
UCS-MR-2X164RX-C 2X16GB DDR3-1333-MHz RDIMM/PC3-10600/quad rank/x4/1.35v 1.5/1.35 4
UCS-MR-2X324RX-C 2x32GB DDR3-1333-MHz RDIMM/PC3-10600/quad rank/x4/1.35v 1.5/1.35 4
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Approved Configurations
(1) Minimum Configuration without memory mirroring
One memory riser with at least one matched DIMM pair. The memory riser must be installed
in a slot controlled by either CPU1 or CPU2. All four CPUs can run from a single DIMM pair.
(2) Maximum Configuration without memory mirroring
Ranks/ DIMM
Eight memory risers with at least one matched DIMM pair per riser (16 DIMMs total) and up to
four matched DIMM pairs per riser (64 DIMMs total).
(3) Minimum Configuration with memory mirroring
One memory riser with at least two matched DIMM pairs.
(4) Maximum Configuration with memory mirroring
Eight memory risers with at least two matched DIMM pairs per riser (16 DIMMs total) and up
to four matched DIMM pairs per riser (64 DIMMs total).
NOTE: There are three memory mirroring modes:
1 Intra-socket mirroring
2 Inter-socket cross-memory-controller mirroring
3 Inter-socket complete master-slave mirroring
Mirroring mode can be configured using the UCS Manager BIOS Policy RAS Memory tab
16
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 17
CONFIGURING the SERVER
Caveats
Each CPU controls four DDR3 channels.
The minimum DIMM configuration is at least one matched DIMM pair installed in a memory
riser on either CPU1 or CPU2. All four CPUs can run from a single DIMM pair.
DIMMs are required to be populated in pairs. DIMMs for this server are available as two-DIMM
kits.
The DIMMs in any given pair must be identical.
Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes
inaccessible.
For optimal performance, distribute DIMMs evenly across all installed CPUs and memory
buffers.
DIMMs within a channel are populated starting with the DIMMs farthest from the memory
buffer in a fill-farthest approach.
Matched pairs of risers on paired DDR3 channels must have identical DIMM configurations.
For more information about memory, see CPUs and DIMMs on page 49.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
17
Page 18
CONFIGURING the SERVER
STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs
The standard disk drive features are:
2.5-inch small form factor
Hot-pluggable
Sled-mounted
Choose Drives
The available drives are listed in Table 6.
Table 6 Available Hot-Pluggable Sled-Mounted HDDs and SSDs
Product ID (PID) PID Description
Drive Type
Capacity
HDDs
A03-D146GC2 146 GB SAS 15K RPM SFF HDD SAS 146 GB
A03-D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB
UCS-HDD300GI2F105 300 GB 6 Gb SAS 15K RPM SFF HDD SAS 300 GB
A03-D500GC3 500 GB 6 Gb SATA 7.2K RPM SFF SATA 500 GB
A03-D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB
UCS-HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF HDD SAS 900 GB
A03-D1TBSATA 1 TB SATA 7.2K RPM SFF HDD SATA 1 TB
SSDs
UCS-SD100G0KA2-E 100 GB SATA 2.5 inch Enterprise Performance SSD SATA 100 GB
UCS-SD100G0KA2-G 100 GB 2.5 inch Enterprise Value SSD SATA 100 GB
UCS-SD200G0KA2-E 200 GB 2.5 SATA Enterprise performance SSD SATA 200 GB
UCS-SD300G0KA2-E 300 GB 2.5 SATA Enterprise performance SSD SATA 300 GB
UCS-SD400G0KA2-G 400 GB 2.5 Enterprise Value SSD SATA 400 GB
Approved Configurations
(1) LSI MegaRAID SAS 9260-8i RAID controller (battery backup is optional)
Select up to 12 SAS or SATA drives listed in Table 6 (you can mix SAS/SATA drives, but not
HDD/SSD drives). This configuration supports RAID 0, 1, 5, 6, and 10.
(2) LSI MegaRAID SAS 9240-8i RAID controller (no battery backup)
18
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 19
CONFIGURING the SERVER
Select up to 8 SAS or SATA drives listed in Table 6 (you can mix SAS/SATA drives, but not
HDD/SSD drives). This configuration supports RAID 0and 1.
Caveats
SSDs and HDDs should not be mixed in the same RAID volume.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
19
Page 20
CONFIGURING the SERVER
STEP 5 CHOOSE RAID CONFIGURATION
The C460 M2 server accommodates either an LSI MegaRAID SAS 9260-8i or LSI MegaRAID SAS 9240-8i RAID controller. The C460 M2 contains a drive bay housing up to 12 HDDs or SSDs.
Cisco can provide factory-configured RAID 0, 1, 5, 6, and 10 systems depending on the RAID implementation chosen, the RAID controller chosen, and the number of drives ordered. Factory-configured RAID options are listed at the end of 60 are supported on the 9260-8i, but are not factory configurable.
Choose RAID Options
Choose one RAID controller, one RAID configuration option, and, if desired, the battery backup option listed in
Table 7 Available RAID Options
Product ID (PID) PID Description
RAID Controllers
Table 7.
Table 7. Note that RAID levels 50 and
RC460-PL001 LSI MegaRAID SAS 9260-8i (RAID 0, 1, 5, 6, 10, 50, 60 supported)
Plugs into the dedicated SAS riser on the rear of the server on the left (see
Figure 4 on page 6).
Supports from 1 to 12 internal SAS or SATA drives
Battery backup (R2XX-LBBU2) is required (see the RAID Battery Backup
section later in this table)
Factory-configured RAID options: RAID 0, 1, 5, 6, 10 (see the RAID PIDs
section in this table)
RC460-PL002 LSI MegaRAID SAS 9240-8i (RAID 0 and 1)
Plugs into the dedicated SAS riser on the rear of the server on the left (see
Figure 4 on page 6).
Supports from 1 to 8 internal SAS or SATA drives
Battery backup option not available
Factory-configured RAID options: RAID 0 and 1 (see the RAID PIDs section in
this table)
RAID Battery Backup Option
R2XX-LBBU2 Battery Backup (for LSI MegaRAID SAS 9260-8i controller only)
RAID Configuration
R2XX-RAID0 Factory pre-configured RAID striping option
Enable RAID 0 Setting. Requires a minimum of 1 hard drive.
R2XX-RAID1 Factory pre-configured RAID mirroring option
Enable RAID 1 Setting. Requires exactly 2 drives, with same size, speed, capacity.
20
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 21
Table 7 Available RAID Options (continued)
Product ID (PID) PID Description
R2XX-RAID5 Factory pre-configured RAID option
Enable RAID 5 Setting. Requires minimum 3 drives of same size, speed, capacity.
R2XX-RAID6 Factory pre-configured RAID option
Enable RAID 6 Setting. Requires minimum 4 drives of same size, speed, capacity.
R2XX-RAID10 Factory pre-configured RAID option
Enable RAID 10 Setting. Requires an even number of drives (minimum 4 drives) of same size, speed, capacity.
.
NOTE: No RAID option can be chosen if you have one of the following configurations:
• A mix of SAS and SATA drives
•No drives
CONFIGURING the SERVER
Approved Configurations
(1) One RAID Controller Card
Choose either the RC460-PL001 LSI MegaRAID SAS 9260-8i RAID controller or the
RC460-PL002 LSI MegaRAID SAS 9240-8i RAID controller listed in
Table 7. You will be able to
control from 1 to 12 drives with the 9260-8i RAID controller and from 1 to 8 drives with the 9240-8i RAID controller.
Caveats
The RAID controller card is preinstalled in a dedicated SAS riser slot in the rear of the server.
See
Figure 4 on page 6.
You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is
pre-configured at the factory. If you do not choose a RAID configuration, the disks will be configured as a JBOD.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
21
Page 22
CONFIGURING the SERVER
STEP 6 CHOOSE PCIe OPTION CARD(S)
The standard PCIe card offerings are:
Converged Network Adapters (CNA)
Network Interface Cards (NICs)
Host Bus Adapters (HBAs)
UCS Storage Accelerators
Choose PCIe Option Cards
The available PCIe option cards are listed in Table 8.
Table 8 Available PCIe Option Cards
Product ID (PID) PID Description
Card Height
Converged Network Adapters (CNA)
N2XX-AEPCI01 Emulex OneConnect OCe10102-F CNA 2-port 10Gbps Half
UCSC-PCIE-BSFP Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI Half
UCSC-PCIE-BTG Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI Half
UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA Half
UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half
UCSC-PCIE-QSFP Qlogic QLE8242-CU Dual Port 10 GbE FCoE CNA Half
Network Interface Cards (NICs)
N2XX-ABPCI03-M3 Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers Half
N2XX-AIPCI01 Intel Dual Port 10 GbE Ethernet X520 Server Adapter Half
Host Bus Adapters (HBAs)
N2XX-AEPCI03 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Half
N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half
N2XX-AQPCI03 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half
N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half
22
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 23
Notes . . .
Table 8 Available PCIe Option Cards (continued)
CONFIGURING the SERVER
Product ID (PID) PID Description
Card Height
UCS Storage Accelerators
UCSC-F-FIO-3000M Cisco UCS 3.0 TB MLC Fusion ioDrive2 for C-Series Servers Full
UCSC-F-FIO-1205M Cisco UCS 1205 GB MLC Fusion ioDrive2 for C-Series Servers Half
UCSC-F-FIO-785M Cisco UCS 785 GB MLC Fusion ioDrive2 for C-Series Servers Half
UCSC-F-FIO-365M Cisco UCS 365GB MLC Fusion ioDrive2 for C-Series Servers Half
Computing Processor Accessory Kit
UCSC-GPU-N01-C460
Accessory Kit for NVIDIA Tesla C2050 GPU1 includes power cable,
N/A
panels)
1. The NVIDIA Tesla card itself can be ordered from a certified NVIDIA Tesla reseller partner or distributor listed at
the following link: http://www.nvidia.com/object/tesla_wtb.html#3. Note that the C2050 is a full-height PCIe x16 dual-slot form factor card and consumes 238 watts (max). It can be installed only in PCIe slot 5.
Approved Configurations
(1) Select up to 10 PCIe Cards
Use Table 9 as a guide for adding PCIe cards. See Figure 6 for the slot locations.
Table 9 PCIe Expansion Slot Numbering
Slot Number Slot Characteristics
1 and 2 PCIe Gen 2x8, 3/4 length card, x24 hot-swappable connectors
3 and 4 PCIe Gen 2x4, 1/2 length card, x8 connectors
5 PCIe Gen 2x16, 3/4 length card, x16 connector
6 and 7 PCIe Gen 2x8, 3/4 length card, x8 hot-swappable connectors
8 PCIe Gen 1x4, 3/4 length card, x8 connector
9 PCIe Gen 1x4, 1/2 length card, x8 connector
10 PCIe Gen 2x4, 1/2 length card, x8 connector
Cisco UCS C460 M2 High-Performance Rack-Mount Server
23
Page 24
CONFIGURING the SERVER
198935
1
6 7
2
3 4
8 9
5
10
Figure 6 PCIe Slot Locations
24
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 25
CONFIGURING the SERVER
Caveats
CPU3 must be installed to support PCIe slots 5, 6, 7, 9, and 10.
Legacy I/O devices such as video cards are only supported on slots 1, 2, 3, 4 and 8.
The Cisco Card NIC mode is currently supported only with a Cisco 1225 VIC
(UCSC-PCIE-CSC-02) that is installed in PCIe slot 1.
The C460 server accommodates the Cisco 1225 Virtual Interface card, which is supported
only in slots 1 and 2.
Only one Cisco 1225 VIC can be used for both UCSM management and data traffic in
the C460 M2 server
The Cisco 1225 VIC in slot 1 handles management and data traffic.
If a second Cisco 1225 VIC is installed in slot 2, it will be used for data traffic only.
This is due to the standby power supplied only to slot 1.
All PCIe slots are standard-height and require a standard-height mounting bracket on the
PCIe card.
Additional considerations for the Cisco 1225 VIC card:
Supports 10G SFP+ optical and copper twinax connections
To use the Cisco Card NIC mode, this card must be installed in PCIe slot 1. Slot 1 can
operate while the server is in standby power mode.
Requires that the server has CIMC firmware version 1.4(6) or later installed. There is
a heartbeat LED on the top of the card that indicates when firmware is active.
To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS
Manager 2.1(0) or later, the minimum card-firmware and uboot image level is
2.1(0.306).
To help ensure that your operating system is compatible with the cards you have selected,
please check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
Cisco UCS C460 M2 High-Performance Rack-Mount Server
25
Page 26
CONFIGURING the SERVER
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES
Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server.
Choose Optional Twinax Cables
Copper twinax cables are listed in Table 10. You can choose cable lengths of 1, 3, 5, 7, or 10
meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.
Table 10 Available Twinax Cables
Product ID (PID) PID Description
SFP-H10GB-CU1M 10GBASE-CU SFP+ Cable (1 M)
SFP-H10GB-CU3M 10GBASE-CU SFP+ Cable (3 M)
SFP-H10GB-CU5M 10GBASE-CU SFP+ Cable (5 M)
SFP-H10GB-ACU7M 10GBASE-CU SFP+ Cable (7 M)
SFP-H10GB-ACU10M 10GBASE-CU SFP+ Cable (10 M)
Approved Configurations
(1) Choose Up to Two Twinax Cables for Each Network Card Ordered
You may choose one or two twinax cables for each network card ordered. The cables can be
different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.
Caveats
The twinax cables listed in Table 10 can be ordered only for the following PCIe cards:
UCS-PCIE-BSFP (Broadcom 57712)
N2XX-AEPCI01 (Emulex OCe10102-F)
N2XX-AIPCI01 (Intel Dual Port Ethernet X520)
N2XX-AQPCI01 (Qlogic QLE 8152-CNA)
UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)
26
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 27
Choose Optional SFP Modules
Optical Cisco SFP+ modules are listed in Table 11.
Table 11 Available SFP Modules
Product ID (PID) PID Description
SFP-10G-SR 10GBASE-SR SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
DS-SFP-FC8G-SW 8 Gbit SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
Approved Configurations
(1) Choose Up to Two SFP+ Modules for Each Network Card Ordered
You may choose one or two SFP+ optical modules cables for each network card ordered. You
would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.
CONFIGURING the SERVER
See Figure 7 on page 28 for typical SFP+ and twinax connections to the network cards.
Caveats
The SFP-10G-SR optical module listed in Table 11 should be ordered only for the following PCIe
cards, as they do not come by default with any optical modules:
UCSC-PCIE-BSFP (Broadcom 57712)
N2XX-AEPCI01 (Emulex OCe10102-F)
UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)
The DS-SFP-FC8G-SW optical module listed in Table 11 should be ordered only for the following
PCIe cards, as they do not come by default with any optical modules:
N2XX-AEPCI05 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA)
Cisco UCS C460 M2 High-Performance Rack-Mount Server
27
Page 28
CONFIGURING the SERVER
Figure 7 Network Card Connections
28
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 29
STEP 8 ORDER POWER SUPPLIES
If you ordered a 2-CPU system, the base server comes with two power supplies, which is adequate to power the server. If you ordered a 4-CPU system, you must order two additional power supplies, listed in
Table 12 Power Supplies
Product ID (PID) PID Description
RC460-PSU2-850W 850W POWER SUPPLY UNIT FOR C-SERIES C460
Table 15.
CONFIGURING the SERVER
Cisco UCS C460 M2 High-Performance Rack-Mount Server
29
Page 30
CONFIGURING the SERVER
1
STEP 9 SELECT AC POWER CORD(s)
Select the appropriate AC power cords listed in Table 13. You may select a minimum of no
power cords and a maximum of two power cords. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
Table 13 Available Power Cords
Product ID (PID) PID Description Images
R2XX-DMYMPWRCORD No power cord (dummy PID to
allow for a no power cord option)
CAB-N5K6A-NA Power Cord, 200/240V 6A, North
America
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,
C13/C14, 10A/250V
CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR,
2 Meter, C13/C14,10A/250V
Not applicable
Plug: NEMA 6-15P
Cordset rating: 10 A, 250 V
Length: 8.2 ft
Connector:
IEC60320/C13
86570
CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6
0320/C13, 3.0M
30
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 31
Table 13 Available Power Cords
2500 mm
Cordset rating: 10 A, 250/500 V MAX
Length: 8.2 ft
Plug:
EL 219
(IRAM 2073)
Connector:
EL 701
(IEC60320/C13)
Plug:
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
EL 701C
(EN 60320/C15)
EL 210
(BS 1363A) 13 AMP fuse
Cordset rating 10A, 250V
(2500 mm)
Plug:
EL 218
(CCEE GB2009)
186573
Connector:
EL 701
(IEC60320/C13)
Connector:
VSCC15
Cordset rating: 10A/16 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Plug:
M2511
186576
1
Cordset rating 10A, 250V/500V MAX
(2500 mm)
Plug:
EL 212 (SI-32)
186574
Connector:
EL 701B
(IEC60320/C13)
EL
-212
16A 250V
Product ID (PID) PID Description Images
SFS-250V-10A-AR Power Cord, SFS, 250V, 10A,
Argentina
CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug,
Australia
SFS-250V-10A-CN Power Cord, SFS, 250V, 10A, China
CONFIGURING the SERVER
CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC
CAB-9K10A-EU Power Cord, 250VAC 10A CEE 7/7
Plug, EU
SFS-250V-10A-ID Power Cord, SFS, 250V, 10A, India
SFS-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel
Plug:
EL 208
Cordset rating 16A, 250V
(2500mm)
OVE
Connector:
EL 701
87490
Cisco UCS C460 M2 High-Performance Rack-Mount Server
31
Page 32
CONFIGURING the SERVER
Plug:
I/3G
(CEI 23-16)
Connector
C15M
(EN60320/C15 )
Cordset rating: 10 A, 250 V
Length: 8 ft 2 in. (2.5 m)
186575
Plug:
MP232-R
Cordset rating: 10 A, 250 V
Length: 8 ft. 2 in (2.5 m)
Connector:
IEC 60320 C15
Plug:
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
186580
Connector:
EL 701C
(EN 60320/C15)
EL 210
(BS 1363A) 13 AMP fuse
Table 13 Available Power Cords
Product ID (PID) PID Description Images
CAB-9K10A-IT Power Cord, 250VAC 10A CEI
23-16/VII Plug, Italy
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
CAB-9K12A-NA Power Cord, 125VAC 13A NEMA
5-15 Plug, North America
CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil
1
76.2 From Plug End
2,133.6 ± 25
CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available
32
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 33
STEP 10 ORDER OPTIONAL SLIDE RAIL KIT
Two different optional slide rail kits can be ordered:
Tool-less slide rail kit (RC460-SLDRAIL)
Short slide rail kit (RC460-SLDRAIL-S), where space is at a premium and a cable management
arm is not needed
You can order one of the slide rail kits listed in Table 14.
Table 14 Slide Rail Kits
Product ID (PID) PID Description
RC460-SLDRAIL Slide rail kit for the UCS C460 rack server
RC460-SLDRAIL-S Short slide rail kit for C460, no CMA
CONFIGURING the SERVER
Cisco UCS C460 M2 High-Performance Rack-Mount Server
33
Page 34
CONFIGURING the SERVER
STEP 11 ORDER OPTIONAL CABLE MANAGEMENT ARM
A cable management arm is available for the tool-less slide rail kit (PID RC460-SLDRAIL). The cable management arm attaches to the left and right slide rails at the rear of the server and is used for cable management. You can order the cable management arm listed in
Table 15 Cable Management Arm
Product ID (PID) PID Description
RC460-CBLARM Cable Management Arm for C460
Table 15.
34
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 35
STEP 12 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE
One or two optional 2 GB eUSB drives may be ordered and used as a boot drive. The eUSB drives plug into vertical USB slots on the motherboard. You can order the eUSB boot drive listed in
Table 16.
Table 16 Available USB Drive
CONFIGURING the SERVER
Product ID (PID) PID Description
Drive Type
Capacity
RC460-EUSB 2 GB eUSB Drive USB 2 GB
Approved Configurations
Select one or two eUSB drives from Table 16.
Caveats
None
Cisco UCS C460 M2 High-Performance Rack-Mount Server
35
Page 36
CONFIGURING the SERVER
STEP 13 ORDER A TRUSTED PLATFORM MODULE
Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.
The TPM ordering information is listed in Table 17.
Table 17 Trusted Platform Module
Product ID (PID) PID Description
UCSC-TPM-001-C460 Tr ust e d Pl a tf o rm M o dul e
36
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 37
CONFIGURING the SERVER
STEP 14 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE
Several operating systems and value-added software programs are available. Select as desired
from Table
Table 18 OSs and Value-Added Software (for 4-CPU servers)
PID Description Product ID (PID)
Microsoft Windows Server
MSWS-08R2-STHV Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL)
MSWS-08R2-ENHV Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL)
MSWS-08R2-DCHV2S Windows Svr 2008 R2-2 CPU-Data Center
MSWS-12-ST2S Windows Server 2012 Standard (2 CPU/2 VMs)
MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs)
MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC
MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco Svc
18.
SUSE Linux Enterprise Server
SLES-1A SLES/1yr subscription/svcs required/0 media
SLES-3A SLES/3yr subscription/svcs required/0 media
UCS-SLES-TERMS Acceptance of Terms, Standalone SLES License for UCS Servers
Red Hat Enterprise Linux
RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required
RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required
RHEL-2S-4G-1A RHEL/2 Socket/4 Guest/1Yr Svcs Required
RHEL-2S-4G-3A RHEL/2 Socket/4 Guest/3Yr Svcs Required
RHEL-2S-UG-1A RHEL/2 Socket/U Guest/1Yr Svcs Required
RHEL-2S-UG-3A RHEL/2 Socket/U Guest/3Yr Svcs Required
RHEL-4S-1G-1A RHEL/4 Socket/1 Guest/1Yr Svcs Required
RHEL-4S-1G-3A RHEL/4 Socket/1 Guest/3Yr Svcs Required
RHEL-4S-4G-1A RHEL/4 Socket/4 Guest/1Yr Svcs Required
RHEL-4S-4G-3A RHEL/4 Socket/4 Guest/3Yr Svcs Required
RHEL-4S-UG-1A RHEL/4 Socket/U Guest/1Yr Svcs Required
RHEL-4S-UG-3A RHEL/4 Socket/U Guest/3Yr Svcs Required
RHEL-HA-2S-1A RHEL Option/High-Availability/2 Socket/1Yr Svcs Required
RHEL-HA-2S-3A RHEL Option/High-Availability/2 Socket/3Yr Svcs Required
Cisco UCS C460 M2 High-Performance Rack-Mount Server
37
Page 38
CONFIGURING the SERVER
Table 18 OSs and Value-Added Software (for 4-CPU servers) (continued)
PID Description Product ID (PID)
RHEL-HA-4S-1A RHEL Option/High-Availability/4 Socket/1Yr Svcs Required
RHEL-HA-4S-3A RHEL Option/High-Availability/4 Socket/3Yr Svcs Required
RHEL-RS-2S-1A RHEL Option/Resilient Storage w/HA /2 Socket/1 Yr Svcs Reqd
RHEL-RS-2S-3A RHEL Option/Resilient Storage w/HA /2 Socket/3 Yr Svcs Reqd
RHEL-RS-4S-1A RHEL Option/Resilient Storage w/HA /4 Socket/1 Yr Svcs Reqd
RHEL-RS-4S-3A RHEL Option/Resilient Storage w/HA /4 Socket/3 Yr Svcs Reqd
RHEL-SFS-2S-1A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required
RHEL-SFS-2S-3A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required
RHEL-SFS-4S-1A RHEL Option/Scalable File System/4 Socket/1 Yr Svcs Required
RHEL-SFS-4S-3A RHEL Option/Scalable File System/4 Socket/3 Yr Svcs Required
BMC
BMC-002 BMC BladeLogic CM, Physical Server
BMC-012 BMC BPPM Per Server
BMC-SE-4C BMC BladeLogic Standard Edition, 4 Cores, Support Required
BMC-SE-6C BMC BladeLogic Standard Edition, 6 Cores, Support Required
BMC-SE-8C BMC BladeLogic Standard Edition, 8 Cores, Support Required
BMC-SE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required
BMC-AE-4C BMC BladeLogic Advanced Edition, 4 Cores, Support Required
BMC-AE-6C BMC BladeLogic Advanced Edition, 6 Cores, Support Required
BMC-AE-8C BMC BladeLogic Advanced Edition, 8 Cores, Support Required
BMC-AE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required
UCS-BMC-TERMS Acceptance of Terms, Standalone BMC License for UCS Servers
VMWare 5
VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd
VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd
VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd
VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd
VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Rqd
VMW-VS5-ENT-1A VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Rqd
VMW-VS5-ENT-2A VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Rqd
VMW-VS5-ENT-3A VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Rqd
VMW-VS5-ENT-4A VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Rqd
38
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 39
CONFIGURING the SERVER
Table 18 OSs and Value-Added Software (for 4-CPU servers) (continued)
PID Description Product ID (PID)
VMW-VS5-ENT-5A VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Rqd
VMW-VS5-ENTP-1A VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Rqd
VMW-VS5-ENTP-2A VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Rqd
VMW-VS5-ENTP-3A VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Rqd
VMW-VS5-ENTP-4A VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Rqd
VMW-VS5-ENTP-5A VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Rqd
VMW-VC5-STD-1A VMware vCenter 5 Server Standard, 1 yr support required
VMW-VC5-STD-2A VMware vCenter 5 Server Standard, 2 yr support required
VMW-VC5-STD-3A VMware vCenter 5 Server Standard, 3 yr support required
VMW-VC5-STD-4A VMware vCenter 5 Server Standard, 4 yr support required
VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required
UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers
Cisco UCS C460 M2 High-Performance Rack-Mount Server
39
Page 40
CONFIGURING the SERVER
STEP 15 CHOOSE OPERATING SYSTEM MEDIA KIT
Choose the optional operating system media listed in Table 19.
Table 19 OS Media
Product ID (PID) PID Description
RHEL-6 RHEL 6 Recovery Media Only (Multilingual)
SLES-11 SLES 11 media only (multilingual)
MSWS-08R2-STHV-RM Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media
MSWS-08RS-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media
MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media
MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media
MSWS-12-DC2S-RM Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media
40
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 41
STEP 16 CHOOSE SERVICE and SUPPORT LEVEL
A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:
Three-year parts coverage.
Next business day (NBD) onsite parts replacement eight hours a day, five days a week.
90-day software warranty on media.
Ongoing downloads of BIOS, drivers, and firmware updates.
UCSM updates for systems with Unified Computing System Manager. These updates include
minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.
SMARTnet for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
CONFIGURING the SERVER
For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in
Table 20.
Table 20 Cisco SMARTnet for UCS Service
Product ID (PID) On Site? Description
CON-PREM-C460M2 Ye s ONSITE 24X7X2 C460 M2 Rack Server
CON-OSP-C460M2 Yes ONSITE 24X7X4 C460 M2 Rack Server
CON-OSE-C460M2 Yes ONSITE 8X5X4 C460 M2 Rack Server
CON-OS-C460M2 Ye s ONSITE 8X5XNBD C460 M2 Rack Server
CON-S2P-C460M2 No SMARTNET 24X7X2 C460 M2 Rack Server
CON-SNTP-C460M2 No SMARTNET 24X7X4 C460 M2 Rack Server
CON-SNTE-C460M2 No SMARTNET 8X5X4 C460 M2 Rack Server
CON-SNT-C460M2 No SMARTNET 8X5XNBD C460 M2 Rack Server
Cisco UCS C460 M2 High-Performance Rack-Mount Server
41
Page 42
CONFIGURING the SERVER
SMARTnet for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in
Table 21 SMARTnet for UCS Hardware Only Service
Table 21.
Product ID (PID)
Service Level GSP
On Site?
Description
CON-UCW7-C460M2 UCW7 Ye s UC PLUS 24X7X4OS C460 M2 Rack Server
CON-UCW5-C460M2 UCW5 Ye s UC PLUS 8X5XNBDOS C460 M2 Rack Server
Unified Computing Partner Support Service
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:
Expand their service portfolios to support the most complex network environments
Lower delivery costs
Deliver services that increase customer loyalty
Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets. This helps partners to realize higher margins and expand their practice.
PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL:
www.cisco.com/go/partnerucssupport
The two Partner Unified Computing Support Options include:
Partner Support Service for UCS
Partner Support Service for UCS Hardware Only
42
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 43
CONFIGURING the SERVER
Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. See
Table 22.
Table 22 Partner Support Service for UCS
Product ID (PID)
Service Level GSP
On Site?
Description
CON-PSJ1-C460M2 PSJ1 No UCS SUPP PSS 8X5XNBD C460 M2 Rack Server
CON-PSJ2-C460M2 PSJ2 No UCS SUPP PSS 8X5X4 C460 M2 Rack Server
CON-PSJ3-C460M2 PSJ3 No UCS SUPP PSS 24X7X4 C460 M2 Rack Server
CON-PSJ4-C460M2 PSJ4 No UCS SUPP PSS 24X7X2 C460 M2 Rack Server
Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours. See
Table 23.
Table 23 Partner Support Service for UCS (Hardware Only)
Product ID (PID)
Service Level GSP
On Site?
Description
CON-PSW2-C460M2 PSW2 No UCS W PL PSS 8X5X4 C460 M2 Rack Server
CON-PSW3-C460M2 PSW3 No UCS W PL PSS 24X7X4 C460 M2 Rack Server
CON-PSW4-C460M2 PSW4 No UCS W PL PSS 24X7X2 C460 M2 Rack Server
Unified Computing Combined Support Service
Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:
Optimize the uptime, performance, and efficiency of your UCS
Protect your vital business applications by rapidly identifying and addressing issues
Strengthen in-house expertise through knowledge transfer and mentoring
Improve operational efficiency by allowing UCS experts to augment your internal staff
resources
Enhance business agility by diagnosing potential issues before they affect your operations
Cisco UCS C460 M2 High-Performance Rack-Mount Server
43
Page 44
CONFIGURING the SERVER
You can choose a service listed in Table 24.
Table 24 UCS Computing Combined Support Service
Service
Product ID (PID)
Level GSP
CON-NCF2-C460M2 NCF2 CON-NCF2P-C460M2 NCF2P CON-NCF4P-C460M2 NCF4P CON-NCF4S-C460M2 NCF4S CON-NCFCS-C460M2 NCFCS CON-NCFE-C460M2 NCFE CON-NCFP-C460M2 NCFP CON-NCFT-C460M2 NCFT
On Site?
No
Yes
Yes
Yes
Yes
No
No
No
Description
CMB SPT SVC 24X7X2 C460 M2 Rack Server
CMB SPT SVC 24X7X2OS C460 M2 Rack Server
CMB SPT SVC 24X7X4OS C460 M2 Rack Server
CMB SPT SVC 8X5X4OS C460 M2 Rack Server
CMB SPT SVC 8X5XNBDOS C460 M2 Rack Server
CMB SPT SVC 8X5X4 C460 M2 Rack Server
CMB SPT SVC 24X7X4 C460 M2 Rack Server
CMB SPT SVC 8X5XNBD C460 M2 Rack Server
Unified Computing Drive Retention Service
With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
44
Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.
If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in
Table 25.
NOTE: Cisco does not offer a certified drive destruction service as part of this
service.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 45
Table 25 Drive Retention Service Options
CONFIGURING the SERVER
Service Description
SMARTnet for UCS Service with Drive Retention
SMARTnet for UCS HW ONLY+Drive Retention
For more service and support information, see the following URL:
http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf
For a complete listing of available services for Cisco Unified Computing System, see this URL:
http://www.cisco.com/en/US/products/ps10312/serv_group_home.html
Service
Program Name
UCS DR
UCS HW+DR
Service
Level GSP
Service Level Product ID (PID)
UCSD7 24x7x4 Onsite CON-UCSD7-C460M2
UCSD7 8x5xNBD Onsite CON-UCSD5-C460M2
UCWD7 24x7x4 Onsite CON-UCWD7-C460M2
UCWD5 8x5xNBD Onsite CON-UCWD5-C460M2
Cisco UCS C460 M2 High-Performance Rack-Mount Server
45
Page 46
OPTIONAL STEP - ORDER RACKS
Notes . . .
OPTIONAL STEP - ORDER RACKS
The optional R42610 rack is available from Cisco for the C-Series servers, including the C460 M2 server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in
Table 26 Racks and Rack Options
Product ID (PID) PID Description
Table 26. Racks are shipped separately from the C460 M2 server.
RACK-UCS
RACK-UCS2
1
1
Cisco R42610 expansion rack, no side panels
Cisco R42610 standard rack, w/side panels
RACK-BLANK-001 Filler panels (qty 12), 1U, plastic, toolless
RACK-CBLMGT-001 Cable mgt D rings (qty 10), metal
RACK-CBLMGT-011 Cable mgt straps (qty 10), Velcro
RACK-FASTEN-001 Mounting screws (qty 100), M6
RACK-FASTEN-002 Cage nuts (qty 50), M6
RACK-JOIN-001 Rack joining kit
1. Use these same base PIDs to order spare racks (available only as next-day replacements).
For more information about the R42610 rack, see RACKS on page 51.
46
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 47
OPTIONAL STEP - ORDER PDU
An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC460 M2 server. This PDU is available in a zero rack unit (RU) style (see
Table 27 PDU Options
Product ID (PID) PID Description
RP208-30-2P-U-2 Zero RU PDU
For more information about the PDU, see PDUs on page 53.
OPTIONAL STEP - ORDER PDU
Table 27).
Cisco UCS C460 M2 High-Performance Rack-Mount Server
47
Page 48
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
CHASSIS
An internal view of the C460 M2 chassis with the top cover removed is shown in Figure 8.
Figure 8 C460 M2 With Top Cover Removed
48
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 49
SUPPLEMENTAL MATERIAL
D D C C
2 1 2 1
CPUs and DIMMs
Physical Layout
Each CPU controls four serial memory interface (SMI) channels (see Figure 5 on page 14). There is one
memory riser for every two channels. There are therefore two memory risers per CPU. Each CPU channel drives a memory buffer on a riser card, and each memory buffer converts a CPU SMI into two DDR3 subchannels that each read and write two DIMM pairs on a memory riser.
The physical layout of a memory riser is shown in Figure 9.
Figure 9 Memory Riser Physical Layout
1
1
2 1 2
A
2
A B B
1 Memory buffer #1 2 Memory buffer #2
In Figure 9, the buffers and channels are:
Buffer 1, subchannel 1: slots 1B and 1D
Buffer 1, subchannel 2: slots 1A and 1C
Buffer 2, subchannel 1: slots 2B and 2D
Buffer 2, subchannel 2: slots 2A and 2C
Memory Population Rules
When considering the memory configuration of your server, you should observe the following:
The minimum configuration for the server is at least one matched DIMM pair installed in a
memory riser on either CPU1 or CPU2 All four CPUs can run from a single DIMM pair.
DIMMs are required to be populated in pairs. DIMMs for this server are configured as
two-DIMM kits.
199466
Cisco UCS C460 M2 High-Performance Rack-Mount Server
49
Page 50
SUPPLEMENTAL MATERIAL
The DIMMs in any given pair must be identical.
Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes
inaccessible.
For optimal performance, distribute DIMMs evenly across all installed CPUs and memory
buffers.
DIMMs within a subchannel are populated starting with the DIMMs farthest from the memory
buffer in a fill-farthest approach.
For example, the order that you should populate the four channels on a memory riser is as
follows (see also
1.Slots 1B and 1D (buffer 1, subchannel 1)
2.Slots 1A and 1C (buffer 1, subchannel 2)
3.Slots 2B and 2D (buffer 2, subchannel 1)
4.Slots 2A and 2C (buffer 2, subchannel 2
Figure 9 on page 49):
50
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 51
SUPPLEMENTAL MATERIAL
RACKS
The Cisco R42610 rack (see Figure 10) is certified for Cisco UCS installation at customer sites and is
suitable for the following equipment:
Cisco UCS B-Series servers and fabric interconnects
Cisco UCS C-Series and select Nexus switches
The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in
Table 28 Cisco R42610 Rack Specifications
Parameter Standard Rack Expansion Rack
Table 28.
Dimensions (H x W x D) 78.74 x 24 x 43.38 in.
(2000 x 610 x 1102 mm)
Dimensions (H x W x D) with packaging
Distance from front
89 x 33 x 47 in. (2261 x 838 x 1194 mm)
29.2 in. (741 mm) 29.2 in. (741 mm)
78.74 x 23.58 x 43.38 in. (2000 x 599 x 1102 mm)
89 x 33 x 47 in. (2261 x 838 x 1194 mm)
mounting rail to rear mounting rail
Weight 299.83 lb (136 kg) 231. 49 lb (105 kg)
Weight with packaging 354 lb
(161 kg)
284 lb (129 kg)
Side panels included Yes No
Equipment mounting
42RU 42RU
capacity
Static load capacity 2100 lb
(954 kg)
2100 lb (954 kg)
Dynamic load capacity Not applicable Not applicable
NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
51
Page 52
SUPPLEMENTAL MATERIAL
Front view - door closed Front view - door open Front view - door removed
Figure 10 Cisco R42610 Rack
52
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 53
SUPPLEMENTAL MATERIAL
PDUs
Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.
Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
The C-series severs accept the zero-rack-unit (0RU) PDU. See Figure 11).
Figure 11 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)
1 Breakers 3 C19 plugs 2 Ground connection 4 C13 plugs
Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.
Cisco UCS C460 M2 High-Performance Rack-Mount Server
53
Page 54
TECHNICAL SPECIFICATIONS
Notes . . .
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 29 UCS C460 M2 Dimensions and Weight
Parameter Value
Height 6.8 in. (174 mm)
Width 16.7 in.(424 mm)
Depth 27.7 in. (704 mm)
Front Clearance 3 in. (7.62 cm)
Side Clearance 1 in. (25.4 mm)
Rear Clearance 6 in. (152.4 mm)
Weight (maximum configuration, including slide rail brackets and cable management arm)
1. The system weight given here is an estimate for a fully configured system and will vary depending on the number of peripheral devices and power supplies.
1
110.23 lbs (50 kg)
*
Power Specifications
The general power specifications for the C460 M2 server are listed in Table 30.
Table 30 UCS C460 M2 Power Specifications
Description Specification
AC input voltage 100 to 127 VAC nominal (Range: 90 to 264 VAC)
AC input frequency 50 to 60 Hz nominal (Range: 47 to 63 Hz)
Maximum AC input current 9 A at 100 VAC
Maximum AC inrush current 30 A peak sub-cycle duration
Maximum output power for each power supply
Power supply output voltage Main power: 12 VDC
Power supply efficiency 92% Peak, complies with 80Plus Gold Standard
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
54
850 W
Standby Power: 5 VDC
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Page 55
TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the C460 M2 server are listed in Table 31.
Table 31 UCS C460 M2 Environmental Specifications
Parameter Minimum
Temperature operating 10°C to 35°C (50°F to 95°F)
Temperature nonoperating -40°C to 70°C (-40°F to 158°F)
Altitude -30 m to 1500 m (-100 ft to 5000 ft)
Humidity nonoperating 95%, noncondensing at temperatures of 25ºC (77ºF) to 30ºC (86ºF)
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in Table 32.
Table 32 UCS C-Series Regulatory Compliance Requirements
Parameter Description
Regulatory Compliance Products should comply with CE Markings per directives
2004/108/EC and 2006/95/EC
Safety UL 60950-1 Second Edition
CAN/CSA-C22.2 No. 60950-1 Second Edition EN 60950-1 Second Edition IEC 60950-1 Second Edition AS/NZS 60950-1 GB4943 2001
EMC - Emissions 47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A
EMC - Immunity EN55024
CISPR24 EN300386 KN24
Cisco UCS C460 M2 High-Performance Rack-Mount Server
55
Page 56
TECHNICAL SPECIFICATIONS
56
Cisco UCS C460 M2 High-Performance Rack-Mount Server
Loading...