port. Use only this SIOC 1 management port;
do not use the SIOC 2 management port.
4Server node Power button/LED 12 Not used at this time
5Server node reset button (resets processor
chipset in server node)
6KVM console connector on server node
13 Solid state drive 2.5-inch drive bays
(only the top two bays are supported)
14 Drive expander module status LED
Used with a KVM cable that provides two
USB, one VGA, and one serial connector
7(Optional) Drive expander module with up to
four 3.5-inch drive bays
15 Optional: 10-Gb SFP+ ports (two on each
SIOC that contains a dual-port SFP+ adapter
card)
8System I/O controller (SIOC), one or two.
Port types vary, depending on the type of
16 Do not use this SIOC 2 port. Use the
management port on SIOC 1.
adapter card installed.
353376
Cisco UCS C3160 Rack Server Installation and Service Guide
1-2
OL-32062-01
Page 3
Chapter 1 Overview
Replaceable Component Locations
This section contains the following topics:
• Replaceable Components Inside the Main Chassis, page 1-3
• Components Inside the Server Node, page 1-5
• Components Inside the System I/O Controller, page 1-6
Replaceable Components Inside the Main Chassis
This section shows the locations of the replaceable components that are inside the main chassis. Some
components are accessible from the rear panel and others are accessible by opening the top covers.
The top view of the system in Figure 1-3 shows the top covers open.
NoteThe internal drives and cooling fans in the system are hot-swappable and are accessed by opening the
top covers. When you rack and cable the system, be sure to allow enough slack in the power and other
cables so that the system can be pulled out on the slide rails far enough to allow clearance for opening
the top covers.
Replaceable Component Locations
OL-32062-01
Cisco UCS C3160 Rack Server Installation and Service Guide
1-3
Page 4
Replaceable Component Locations
Figure 1-3Replaceable Components Inside the Main Chassis (Top View and Rear View)
Chapter 1 Overview
HDD01
HDD02
HDD03
HDD04
HDD05
HDD06
HDD07
HDD08
HDD09
HDD10
HDD11
HDD12
HDD13
HDD14
HDD15
HDD16
HDD17
HDD18
HDD19
HDD20
HDD21
HDD22
HDD23
HDD24
HDD25
HDD26
HDD27
HDD28
2
HDD29
HDD30
HDD31
HDD32
HDD33
HDD34
HDD35
HDD36
HDD37
HDD38
HDD39
HDD40
HDD41
HDD42
HDD43
HDD44
HDD45
HDD46
HDD47
HDD48
HDD49
HDD50
HDD51
HDD52
HDD53
HDD54
HDD55
HDD56
1
FANS
1
2
FANS
3
4
FANS
5
6
FANS
7
8
3
4
HDD 57HDD 58HDD 59HDD 60
5
SSD 1
PSU 1PSU 2PSU 3PSU 4
SSD 2
SIOC 2SIOC 1
8
7
353377
6
1Fan modules (four, hot-swappable)
Each fan module contains two fans. Even numbers are
upper fans, odd numbers are lower fans.
2Internal drive bays (up to 56 3.5-inch drives,
5System I/O controller (SIOC) (one or two)
See also Components Inside the System I/O Controller,
page 1-6.
62.5-inch solid state drives (up to two)
hot-swappable)
3Server node
7Power supplies (four, redundant as 2+2)
See also Components Inside the Server Node, page 1-5.
4Drive expander module 83.5-inch drives (up to four in the optional drive expander
module)
Cisco UCS C3160 Rack Server Installation and Service Guide
1-4
OL-32062-01
Page 5
Chapter 1 Overview
353378
G1
G2
H1
H2
CPU 2CPU 1
F2
F1
E2
E1
C1
C2
D1
D2
B2B1A2
A1
1635
2
4
Components Inside the Server Node
This section shows the locations of the replaceable components that are inside the server node, which is
accessible from the rear of the chassis. The view shown is with the server node removed from the system
and with the cover of the server node removed.
Figure 1-4Replaceable Components Inside the Server Node
Replaceable Component Locations
1RTC battery CR 2032
(accessible with the node cover on)
2DIMMs (8 sockets for each CPU, 16 total)5Cisco modular RAID controller card with
3CPUs and heat sinks (two)6Internal USB port for USB thumb-drive
OL-32062-01
4Trusted platform module socket
SuperCap power module (backup) attached
(accessible with the node cover on)
Cisco UCS C3160 Rack Server Installation and Service Guide
1-5
Page 6
Replaceable Component Locations
Components Inside the System I/O Controller
This section shows the locations of the replaceable components that are inside the system I/O controller,
which is accessible from the rear of the chassis. The view shown is with the cover of the module
removed.
Figure 1-5Replaceable Components Inside the System I/O Controller
Cisco UCS C3160 Rack Server Installation and Service Guide
1-6
OL-32062-01
Page 7
Chapter 1 Overview
System Features Overview
Table 1-1 lists the features of the system.
.
Table 1-1Cisco UCS C3160 System Features
ChassisFour rack-unit (4RU) chassis.
ProcessorsTwo Intel Xeon E5-2600 v2 Series processors inside the server node.
MemoryUp to 16 DIMMs inside the server node.
Multi-bit error
This system supports multi-bit error protection.
protection
StorageThe system has the following storage options:
• Up to 56 internally accessible 3.5-inch drives
• Up to four 3.5-inch drives in the optional drive expander module, accessible
from the rear panel
• Up to two 2.5-inch solid state drives, accessible from the rear-panel
All drives are hot-swappable
Disk
Management
There is one dedicated mezzanine-style socket for a RAID controller with a 1-GB
or 4-GB cache inside the server node.
System Features Overview
1
.
For a list of supported RAID controller options, see RAID Controller
Considerations, page C-1.
RAID BackupThe optional supercap power module (SCPM) mounts to the RAID controller card
that is inside the server node.
PCIe I/OThis system has no PCIe expansion slots.
Network and
management I/O
The system can have one or two system I/O controllers (SIOCs). These each
provide rear-panel connectivity. The ports differ, depending on which adapter card
is installed in the SIOC:
• If the quad-port 1-Gb RJ-45 adapter card is in the SIOC:
–
Four 1-Gb BASE-T Ethernet ports (RJ-45)
–
One 1-Gb dedicated management Ethernet port
• If the dual-port 10-Gb SFP+ adapter card is in the SIOC:
–
Two 10-Gb SFP+ ports
–
One 1-Gb dedicated management Ethernet port
The server node also has one rear-panel KVM connector that can be used with a
KVM cable, which provides two USB, one VGA, and one serial connector.
Internal USBThe system includes one internal USB 2.0 slot inside the server node.
PowerTwo or four power supplies, 1050 W each (hot-swappable and redundant as 2+2).
OL-32062-01
Cisco UCS C3160 Rack Server Installation and Service Guide
1-7
Page 8
System Features Overview
Table 1-1Cisco UCS C3160 System Features (continued)
Chapter 1 Overview
CoolingFour internal fan modules that pull front-to-rear cooling, hot-swappable. Each fan
module contains two fans.
In addition, there is one fan in each power supply.
Baseboard
management
1. Hot-swappable = No preconditioning of the component is required before removal while the system is powered on.