Cisco UCS C210 Server
Installation and Service Guide
Covers UCS C210 Server Generations M1 and M2
July 31, 2013
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Text Part Number: OL-20887-02
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required
to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be
determined by turning the equipment off and on, users are encouraged to try to correct the interference by using one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
StackPower, Cisco StadiumVision, Cisco TelePresence, Cisco TrustSec, Cisco Unified Computing System, Cisco WebEx, DCE, Flip Channels, Flip for Good, Flip
Mino, Flipshare (Design), Flip Ultra, Flip Video, Flip Video (Design), Instant Broadband, and Welcome to the Human Network are trademarks; Changing the Way We Work,
Live, Play, and Learn, Cisco
Access Registrar, Aironet, AllTouch, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the
Cisco
Certified Internetwork Expert logo, Cisco IOS, Cisco Lumin, Cisco Nexus, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,
Collaboration Without Limitation, Continuum, EtherFast, EtherSwitch, Event Center, Explorer, Follow Me Browsing, GainMaker, iLYNX, IOS, iPhone, IronPort, the
IronPort logo, Laser Link, LightStream, Linksys, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, PCNow, PIX, PowerKEY,
PowerPanels, PowerTV, PowerTV (Design), PowerVu, Prisma, ProConnect, ROSA, SenderBase, SMARTnet, Spectrum Expert, StackWise, WebEx, and the WebEx logo are
registered trademarks of Cisco and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or website are the property of their respective owners. The use of the word partner does not imply a partnership relationship
between Cisco and any other company. (1002R)
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display
output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in
illustrative content is unintentional and coincidental.
Cisco UCS C210 Server Installation and Service Guide
Connecting and Powering On the Server (Standalone Mode)2-9
NIC Modes and NIC Redundancy Settings2-12
System BIOS and CIMC Firmware2-13
Updating the BIOS and CIMC Firmware2-13
Accessing the System BIOS 2-14
Motherboard Jumpers2-15
Using the BIOS Recovery Jumper J1E5 to Recover Corrupt BIOS2-16
Clearing the CIMC Admin Password Using Jumper J45 2-17
Using the Clear CMOS Jumper J1E6 2-18
Clearing the BIOS Admin Password Using Jumper J1E4 2-19
CHAPTER
OL-20887-02
3Maintaining the Server3-1
Server Monitoring and Management Tools3-1
Cisco Integrated Management Interface (CIMC)3-1
Server Configuration Utility3-1
Cisco UCS C210 Server Installation and Service Guide
iii
Contents
Status LEDs3-2
Front Panel LEDs 3-2
Rear Panel LEDs 3-4
Preparing for Component Installation3-7
Required Equipment 3-7
Shutting Down and Powering Off the Server3-8
Removing and Replacing the Server in a Rack 3-9
Removing and Replacing the Server Top Cover 3-10
Removing and Replacing the Server Front Cover 3-11
Replaceable Component Locations 3-12
Installing or Replacing Components3-13
Installing Hard Drives and Solid State Drives 3-14
Installing Power Supplies 3-16
Installing a DVD Drive 3-17
Installing a Fan Tray 3-19
Installing DIMMs 3-21
Memory Performance Guidelines and Population Rules3-21
DIMM Installation Procedure3-24
Installing CPUs and Heatsinks 3-26
Additional CPU-Related Parts To Order With RMA Replacement Motherboards3-26
CPU Replacement Procedure3-26
Installing a Motherboard CMOS Battery 3-29
Installing a Trusted Platform Module (TPM) 3-30
Replacing a PCIe Riser Card Assembly 3-32
Replacing a PCIe Card 3-34
Replacing a PCIe Card3-34
Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01)3-37
Installing Multiple PCIe Cards and Resolving Limited Resources3-38
Replacing a SAS Extender or SAS Expander3-40
The SAS Extender3-40
The SAS Expander3-40
Replacing a SAS Extender or SAS Expander Card3-41
Replacing an LSI MegaRAID Battery Backup Unit3-42
Installing a Mezzanine Card 3-44
APPENDIX
iv
ATechnical SpecificationsA-1
Physical Specifications A-1
Environmental Specifications A-2
Power Specifications A-2
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Contents
APPENDIX
APPENDIX
APPENDIX
BCable and Power Cord SpecificationsB-1
KVM Cable B-1
Supported Power Cords and Plugs B-2
AC Power Cord IllustrationsB-3
CRAID Controller ConsiderationsC-1
Supported RAID Controllers and Required CablesC-1
Enabling the Integrated Intel ICH10R RAID Controller in the BIOSC-2
Enabling the Mezzanine Card RAID Controller in the BIOSC-3
RAID Controller CablingC-3
How to Determine Which Controller Is in Your Server C-4
How to Disable Quiet Boot for CIMC Firmware Earlier Than Release 1.2(1)C-5
How To Launch Option ROM-Based Controller Utilities C-5
Restoring RAID Configuration After Replacing a RAID ControllerC-6
For More Information C-7
DInstallation for Cisco UCS IntegrationD-1
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
v
Contents
vi
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Preface
This preface describes the audience, organization, and conventions of the Cisco UCS C210 Server
Installation and Service Guide. It also provides information on how to obtain related documentation.
This guide covers UCS C210 Server Generations M1 and M2. Differences between the generations are
noted in text.
Related Documentation
The documentation set for the Cisco Unified Computing System (UCS) C-Series rack-mount servers is
described in the roadmap document at the following link:
Cisco UCS C-Series Documentation Roadmap
Audience
To use this installation guide, you must be familiar with electronic circuitry and wiring practices and
preferably be a technician who is experienced with electronic and electromechanical equipment.
Organization
This guide is organized as follows:
ChapterTitleDescription
Chapter 1OverviewProvides a brief overview of the Cisco Unified Computing
Chapter 2Installing the ServerDescribes how to install the server into a rack, how to cable and
Chapter 3Maintaining the Server Identifies the replaceable components of the server and describes
Appendix A Technical
Appendix B Cable and Power Cord
System (UCS) and the role that the Cisco UCS C210 server plays
in the Cisco Unified Computing System environment.
power on the server, and how to connect to the service processor
and your network.
how to replace them.
Lists physical, environmental, and power specifications.
Specifications
Lists specifications for the supported international power cords.
Specifications
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
vii
ChapterTitleDescription
Appendix C RAID Controller
Appendix D Installation for Cisco
Conventions
This document uses the following conventions for notes, cautions, and safety warnings.
Notes and Cautions contain important information that you should know.
NoteMeans reader take note. Notes contain helpful suggestions or references to material that are not covered
in the publication.
CautionMeans reader be careful. You are capable of doing something that might result in equipment damage or
loss of data.
Considerations
UCS Integration
Provides information about the RAID controller options for this
server and links to LSI documentation for the controllers.
Provides installation and upgrade procedures for installing the
server into Unified Computing System (UCS) integration.
Warning
Waarschuwing
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, can
cause physical injuries. A warning symbol precedes each warning statement.
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device.
SAVE THESE INSTRUCTIONS
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan
veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij
elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard
praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de
waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt
raadplegen.
BEWAAR DEZE INSTRUCTIES
Statement 1071
viii
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Varoitus
Attention
Warnung
TÄRKEITÄ TURVALLISUUSOHJEITA
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin
käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu
onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen
mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien
lausuntonumeroiden avulla.
SÄILYTÄ NÄMÄ OHJEET
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant
entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez
conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures
couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des
avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen
kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und
den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder
Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
Avvertenza
Advarsel
BEWAHREN SIE DIESE HINWEISE GUT AUF.
IMPORTANTI ISTRUZIONI SULLA SICUREZZA
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle
persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli
relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti.
Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le
traduzioni delle avvertenze riportate in questo documento.
CONSERVARE QUESTE ISTRUZIONI
VIKTIGE SIKKERHETSINSTRUKSJONER
Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du
begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med
elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten
av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne
enheten.
TA VARE PÅ DISSE INSTRUKSJONENE
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
ix
Aviso
¡Advertencia!
Varning!
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de
lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos
perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de
prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para
localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo.
GUARDE ESTAS INSTRUÇÕES
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular
cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los
procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el
número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña
a este dispositivo.
GUARDE ESTAS INSTRUCCIONES
VIKTIGA SÄKERHETSANVISNINGAR
Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada.
Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och
känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av
varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna
anordning.
SPARA DESSA ANVISNINGAR
Cisco UCS C210 Server Installation and Service Guide
x
OL-20887-02
Aviso
Advarsel
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões
corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os
circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o
número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de
segurança traduzidos que acompanham o dispositivo.
GUARDE ESTAS INSTRUÇÕES
VIGTIGE SIKKERHEDSANVISNINGER
Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for
legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de
involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til
undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de
oversatte advarsler, der fulgte med denne enhed.
GEM DISSE ANVISNINGER
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
xi
xii
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed
and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free
service and Cisco currently supports RSS
technical documentation, at:
New in Cisco Product Documentation, which also lists all new and
Ve r si o n 2.0.
Cisco UCS C210 Server Installation and Service Guide
xiii
xiv
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
8
195911
1
410
5
2
3
6
7
9
CHAP T ER
1
Overview
The Cisco UCS C210 Server, which is a part of the Cisco UCS C-Series Rack-Mount Server family,
operates in a wide range of data center environments, including those environments that use the Cisco
Unified Computing System, Cisco Nexus family products, and discrete Ethernet and Fibre Channel
switches from Cisco and third parties.
The server is a general-purpose, two-socket, two rack unit (2RU), rack-mount server. The server is
designed to balance performance, density, and efficiency for workloads that require up to 8 terabytes of
economical, high-capacity, reliable internal storage.
Figure 1-1 shows the external features of the front panel. Figure 1-2 shows the external features of the
rear panel.
Figure 1-1Front Panel Features
1Locator button/LED2Network activity LED
3System fault LED4Power button/Power status LED
5CPU fault LED6Memory fault LED
7Power supply fault LED8Console connector (with supplied KVM
cable, provides DB15 video, DB9 serial, and
two USB 2.0 connectors)
9DVD drive (optional)10 Hard drives (up to 16)
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
The Cisco UCS C210 server has the following hardware components and features:
.
Ta b l e 1-1Hardware Features of the Server
Feature or
Component
Cisco UCS C210 Server
EnclosureTwo rack unit (2RU) chassis.
ProcessorsUp to two quad-core Intel Xeon Series processors.
Memory12 DIMM1 slots supporting up to 96 GB of industry-standard DDR32 main
memory.
StorageUp to 16 internal SAS3 or SATA4 hard drives or solid state drives, supporting up to
8 TB total.
Server Generation M2 only—There is also one internal USB port on the
motherboard that you can use with a USB thumb drive (see
Figure 3-5).
Cisco UCS C210 Server Installation and Service Guide
1-2
OL-20887-02
Chapter
Table 1-1Hardware Features of the Server (Continued)
Feature or
ComponentCisco UCS C210 Server
Disk
Management
PCIe I/OUp to five standard-profile PCIe6 expansion cards (or low-profile cards with a
Factory-configured RAID5 support options:
•RAID 0 and 1 support for up to five SATA drives with the integrated SATA
controller.
NoteThe integrated ICH10R RAID controller is not compatible for use with
VMWare ESX/ESXi Server software in any generation or version of
the Cisco UCS C210 server.
•RAID 0, 1, and 1E support for up to four SAS or SATA drives with the optional
LSI 1064-based controller mezzanine card.
•RAID 0, 1, 5, 6, 00, 10, 50 and 60 support for up to 16 SAS or SATA drives
with the optional LSI 9261-8i MegaRAID controller card.
•RAID 0, 1, 5, 6, 00, 10, 50 and 60 support for up to 4 SAS or SATA drives with
the optional LSI 9280-4i4e MegaRAID card.
See Appendix C, “RAID Controller Considerations” for more information about
RAID in this server.
standard-profile adapters), plugged into horizontal riser card sockets.
Two of the riser card sockets are full-length, x8-lane, with a x16 connector. The
other three riser cards are half-length, x8-lane, with a x16 connector.
These integrated Gigabit ports support the Wake on LAN (WoL) and TCP/IP
Offload Engine (TOE) standards.
•One 10/100 Ethernet management port (RJ-45 connector).
•One DB9 serial connector.
•One 15-pin VGA
•Two USB
8
7
connector.
2.0 connectors.
The server also has one front-panel console connector (with supplied KVM9 cable
provides DB15 video, DB9 serial, and two USB 2.0 connectors).
Removable media
devices
One internal DVD drive (orderable option).
The drive supports the following media types: CD-R, CD-ROM, CD-RW, DVD+R,
DVD+RW, DVD-R, DVD-ROM, DVD-RW, +R DL
PowerUp to two power supplies, each with a maximum output of 650 W.
CoolingThree internal fans that force front-to-rear cooling; also one fan in each power
supply.
VideoThe server CIMC chip includes a Matrox G200 core. The Matrox G200 core shares
the same memory as the rest of the CIMC. The first 8 MB of memory are allocated
to the video core, followed by another 5 MB allocated to the compression engine
for difference buffers.
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
See the “Technical Specifications” section on page A-1 for more physical, environmental, and power
details.
1-4
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
CHAP T ER
2
Installing the Server
This chapter describes how to install the server and includes the following sections:
•Unpacking and Inspecting the Server, page 2-2
•Preparing for Installation, page 2-3
•Installing the Server Into a Rack, page 2-5
•Initial Server Setup, page 2-9
•System BIOS and CIMC Firmware, page 2-13
NoteBefore you install, operate, or service a server, review the Regulatory Compliance and Safe ty
Information for Cisco UCS C-Series Servers for important safety information.
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this device.
Statement 1071
OL-20887-02
Warning
SAVE THESE INSTRUCTIONS
Only trained and qualified personnel must be allowed to install, replace, or service this equipment.
Statement 1030
Cisco UCS C210 Server Installation and Service Guide
2-1
Unpacking and Inspecting the Server
TipKeep the shipping container in case the server requires shipping in the future.
NoteThe chassis is thoroughly inspected before shipment. If any damage occurred during transportation or
any items are missing, contact your customer service representative immediately.
To inspect the shipment, follow these steps:
Step 1Remove the server from its cardboard container—save all packaging material.
Step 2Compare the shipment to the equipment list provided by your customer service representative and
Figure 2-1. Verify that you have all items.
Step 3Check for damage and report any discrepancies or damage to your customer service representative. Have
the following information ready:
Chapter
•Invoice number of shipper (see the packing slip)
•Model and serial number of the damaged unit
•Description of damage
•Effect of damage on the installation
Figure 2-1Shipping Box Contents
12
UCS C-Series
Cisco
Nexus 1010
Cisco
3
UCS C-Series
Cisco
4
5
1Server2Drivers and Utilities disc
3Power cord (optional, up to two)4Documentation
5KVM cable
331899
2-2
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Chapter
Preparing for Installation
This section includes the following topics:
•Installation Guidelines, page 2-3
•Rack Requirements, page 2-4
•Required Equipment, page 2-4
•Slide Rail Adjustment Range, page 2-4
Installation Guidelines
Warning
Warning
Warning
Warning
To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of: 35° C (95° F).
Statement 1047
The plug-socket combination must be accessible at all times, because it serves as the main
disconnecting device.
Statement 1019
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated not greater than: 250 V, 15 A.
Statement 1005
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
When installing the server, follow these guidelines:
•Plan your site configuration and prepare the site before installing the server. See the Cisco UCS Site
Preparation Guide for the recommended site planning tasks.
•Ensure that there is adequate space around the server to allow for servicing the server and for
adequate airflow. The airflow in this server is from front to back.
•Ensure that the air-conditioning meets the thermal requirements listed in the “Technical
Specifications” appendix.
OL-20887-02
•Ensure that the cabinet or rack meets the requirements listed in Rack Requirements, page 2-4.
•Ensure that the site power meets the power requirements listed in the “Technical Specifications”
appendix. If available, you can use an uninterruptible power supply (UPS) to protect against power
failures.
CautionAvoid UPS types that use ferroresonant technology. These UPS types can become unstable with systems
such as the Cisco UCS, which can have substantial current draw fluctuations from fluctuating data traffic
patterns.
Cisco UCS C210 Server Installation and Service Guide
2-3
Rack Requirements
This section provides the requirements for the standard open racks, assuming an external ambient air
temperature range of 32 to 95
The rack must be of the following type:
•Standard 19-inch (48.3-cm) wide, four-post EIA rack, with mounting posts that conform to English
universal hole spacing per section 1 of ANSI/EIA-310-D-1992.
•The rack post holes can be square or round when you use the supplied slide rails.
•The minimum vertical rack space per server must be two rack units (RUs), equal to 3.50 inches
(8.89 cm).
•The distance between the front and rear rack posts must be as follows to fit the Cisco slide rails:
–
–
TipThe Cisco R-Series racks and RP-Series PDUs have been designed for optimum performance with Cisco
products and are available from Cisco.
Chapter
°F (0 to 35°C).
For the older rails (R200-1032RAIL), 27 to 37 inches (68.6 to 94.0 cm)
For the new style rails (R2XX-G31032RAIL), 23.5 to 36 inches (59.7 to 91.4 cm)
Required Equipment
The slide rails supplied by Cisco Systems do not require any tools for installation, but you might want
to use a tape measure and level to help level the slide rails during installation.
The slide rails include screws that you can optionally use to apply additional stability. These screws are
not required.
Slide Rail Adjustment Range
The slide rails for this server have an adjustment range of 24 to 36 inches (610 to 914 mm).
2-4
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Chapter
Installing the Server Into a Rack
The qualified and supported part numbers for this component are subject to change over time. For the most
up-to-date list of replaceable components, see the following URL and then scroll to Technical Specifications:
This section describes how to install the server into a rack.
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to ensure
your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component
at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.
Statement 1006
To install the slide rails and the server into a rack, follow these steps:
Step 1Install the slide rails into the rack:
TipUse two people to help keep the slide rails and server level during installation. You can use a tape
measure and level or count the holes in the rack posts to ensure that the slide rails and server are level.
a. Align the slide-rail assembly inside the rack posts with the length-adjustment bracket (item 4)
toward the rear of the rack (see
b. Compress the length-adjustment bracket until the mounting pegs (item 6) and locking clips (item 5)
Figure 2-2).
on the slide-rail assembly engage the desired rack holes on the front and rear rack posts.
If your rack has #10-32 rack-post holes, align the mounting pegs with the holes and then compress
the spring-loaded pegs to expose the #10-32 inner peg (see
Figure 2-3).
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
2-5
Chapter
1
35
2
64
195968
330245
1
2
Figure 2-2Attaching a Slide-Rail Assembly
1Front-left rack post 2Rear-left rack post
3Slide-rail assembly4Length-adjustment bracket
5Locking clip (one on each end of assembly)6Mounting pegs (two on each end of assembly)
NoteThe mounting pegs that protrude through the rack-post holes are designed to fit round or square #12-24
holes, or #10-32 holes when the mounting peg is compressed (see
Figure 2-3). If your rack has #10-32
rack-post holes, align the mounting pegs with the holes and then compress the spring-loaded pegs to
expose the #10-32 inner peg.
Figure 2-3Spring-Loaded Mounting Pegs
1Pegs in standard (uncompressed) position2Pegs compressed to expose 10-32 inner peg
c. Pull the inner slide rails on each assembly out toward the rack front until they hit the internal stops
and lock in place.
2-6
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Chapter
195955
1
345
2
d. Attach the second slide-rail assembly to the opposite side of the rack. Ensure that the two slide-rail
assemblies are level and at the same height with each other.
e. Pull the inner slide rails on each assembly out toward the rack front until they hit the internal stops
and lock in place.
TipYou can optionally use the #2 Phillips screws that come with the slide rails to increase stability after
installation. These screws can be installed on the front attachment bracket on each assembly, but are not
required.
Step 2Attach mounting brackets to the server:
a. Set a mounting bracket (item 3) on the side of the server, aligning its keyed holes over the pegs on
the server (item 2). The plastic installation release clip (item 5) on the bracket should be toward the
server front. See
b. Push the mounting bracket toward the server rear until the locking clip clicks over the server peg.
c. Attach the remaining mounting bracket to the opposite side of the server.
Figure 2-4.
TipYou can optionally use the #1 Phillips screws that come with the slide rails to increase stability after
installation. You can install two of these screws on each side of the server to more permanently attach
the mounting brackets to each side of the server, but they are not required.
Figure 2-4Attaching Mounting Brackets to the Server
CautionThis server weighs approximately 50 pounds (23 kilograms) when fully loaded with components. We
recommend that you use a minimum of two people when lifting the server. Attempting this procedure
alone could result in personal injury or equipment damage.
a. Align the mounting brackets that are attached to the server sides with the front of the empty slide
rails.
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
2-7
b. Push the server into the slide rails until it stops at the internal stops.
c. Push the plastic installation release clip on each mounting bracket toward the server rear (see item
5 in
Figure 2-4), and then continue pushing the server into the rack until its front flanges touch the
rack posts.
d. Close the front-flange latches to secure the server to the front rack posts.
Step 4Attach the (optional) cable management arm (CMA) to the rear of the slide rails:
NoteThe orientation in these instructions refers to a view from the front of the server.
a. Slide the plastic clip on the right end of the CMA length-adjustment slider (item 2) into the rear of
the right slide rail (item 1) until it clips onto the plastic retaining flange inside the slide rail. See
Figure 2-5.
b. Expand the CMA length-adjustment slider (item 2) until its left end aligns with the rear of the left
slide-rail assembly (item 3).
c. Slide the innermost CMA attachment clip (item 4) into the rear of the left slide rail (item 3) and clip
it onto the CMA flange that is on the mounting bracket that is attached to the server.
Chapter
d. Attach the two-hole slotted bracket (item 5) that is on the left end of the CMA length-adjustment
slider to the left slide rail. Fit the two-hole slotted bracket over the two pegs inside the slide rail.
e. Attach the outermost CMA attachment clip (item 6) onto the CMA flange that is on the left slide rail.
Figure 2-5Attaching the Cable Management Arm
126
5
4
3
195969
1Rear of right slide rail (plastic retaining flange
2CMA length-adjustment slider
is inside the rail)
3Rear of left slide rail assembly4Innermost CMA attachment clip
5Two-hole slotted bracket on end of CMA
6Outermost CMA attachment clip
length-adjustment slider
2-8
Step 5Continue with the “Connecting and Powering On the Server (Standalone Mode)” section on page 2-9.
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Chapter
Initial Server Setup
This section contains the following topics:
•Connecting and Powering On the Server (Standalone Mode), page 2-9
•NIC Modes and NIC Redundancy Settings, page 2-12
Connecting and Powering On the Server (Standalone Mode)
NoteThis section describes how to power on the server, assign an IP address, and connect to server
management when using the server in standalone mode. To use the server in UCS integration, specific
cabling and settings are required. See Installation for Cisco UCS Integration, page D-1.
NoteThe server is shipped with a default NIC mode called Shared LOM, default NIC redundancy is
active-active, and DHCP is enabled. Shared LOM mode enables the two 1Gb Ethernet ports to access
the Cisco Integrated Management Interface (CIMC). If you want to use the 10/100 management ports or
a Cisco network adapter card port to access the CIMC, you must first connect to the server and change
the NIC mode as described in
NIC redundancy and set static IP settings.
Step 3 of the following proced ure. In that step , you can al so change the
Use the following procedure to perform initial setup of the server.
Step 1Attach a power cord to each power supply in your server, and then attach the power cord to a grounded
AC power outlet. See the
Wait for approximately two minutes to let the server boot in standby power during the first bootup.
You can verify power status by looking at the Power Status LED on the front panel (see Figure 1-1 on
page 1-1):
•Off—The server is not receiving power. Check the power cord connections and the power source of
the facility.
•Blinking green—The server is in standby power mode. Power is supplied only to the service
processor and some motherboard functions.
•Solid green—The server is in main power mode. Power is supplied to all server components.
NoteDuring bootup, the server beeps once for each USB device that is attached to the server. Even if there
are no external USB devices attached, there is a short beep for each virtual USB device such as a virtual
floppy drive, CD/DVD drive, keyboard, or mouse. A beep is also emitted if a USB device is hot-plugged
or hot-unplugged during BIOS power-on self test (POST), or while you are accessing the BIOS Setup
utility or the EFI shell.
“Power Specifications” section on page A-2 for power specifications.
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
2-9
Chapter
Step 2Use the supplied KVM cable to connect a keyboard and VGA monitor to the console connector on the
front panel (see
NoteAlternatively, you can use the VGA and USB ports on the rear panel. However, you cannot use the front
panel console connector VGA and the rear panel VGA at the same time. If you are connected to one VGA
connector and you then connect a video device to the other connector, the first VGA connector is
disabled. You can then reactivate the first VGA connector only by rebooting the server.
Step 3Set NIC mode, NIC redundancy, and choose whether to enable DHCP or set static network settings:
a. Press the Power button to boot the server. Watch for the prompt to press F8.
b. During bootup, press F8 when prompted to open the BIOS CIMC Configuration Utility.
Figure 1-1 on page 1-1).
2-10
c. Set the NIC mode to your choice for which ports you want to use to access the CIMC for server
management (see
–
Dedicated—The 10/100 management port is used to access the CIMC. You have to select a NIC
Figure 1-2 on page 1-2 for identification of the ports):
redundancy and IP setting.
–
Shared LOM (default)—The two 1Gb Ethernet ports are used to access the CIMC. This is the
factory default setting, along with Active-active NIC redundancy and DHCP enabled.
–
Cisco Card—The ports on an installed Cisco network adapter card are used to access the CIMC.
You have to select a NIC redundancy and IP setting.
NoteThe Cisco Card NIC mode is currently supported only with a Cisco UCS P81E Virtual Interface
Card (N2XX-ACPCI01) that is installed in PCIe slot 1 (see
Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01),
page 3-37.
Cisco UCS C210 Server Installation and Service Guide
Figure 3-18 on page 3-34). See also
OL-20887-02
Chapter
d. Use this utility to change the NIC redundancy to your preference. This server has three possible NIC
redundancy settings:
–
None—The Ethernet ports operate independently and do not fail over if there is a problem.
–
Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
–
Active-active—All Ethernet ports are utilized simultaneously. See NIC Modes and NIC
Redundancy Settings, page 2-12 for more information.
e. Choose whether to enable DHCP for dynamic network settings, or enter static network settings.
NoteBefore you enable DHCP, your DHCP server must be preconfigured with the range of MAC
addresses for this server. The MAC address is printed on a label on the rear of the server. This
server has a range of six MAC addresses assigned to the CIMC. The MAC address printed on
the label is the beginning of the range of six contiguous MAC addresses.
f. Optional: Use this utility to make VLAN settings, and to set a default CIMC user password.
NoteChanges to the settings take effect after approximately 45 seconds. Refresh with F5 and wait
until the new settings appear before you reboot the server in the next step.
g. Press F10 to save your settings and reboot the server.
NoteIf you chose to enable DHCP, the dynamically assigned IP and MAC addresses are displayed on the
console screen during bootup.
Step 4Connect to the CIMC for server management. Connect Ethernet cables from your LAN to the server by
using the ports that you selected by your NIC Mode setting in
Step 3. The Active-active and
Active-passive NIC redundancy settings require you to connect to two ports.
Step 5Use a browser and the IP address of the CIMC to connect to the CIMC Setup Utility. The IP address is
based upon the settings that you made in
Step 3 (either a static address or the address assigned by your
DHCP server).
NoteThe default user name for the server is admin. The default password is password.
Step 6To manage the server, see the Cisco UCS C-Series Rack-Mount Server Configuration Guide or the Cisco
UCS C-Series Rack-Mount Server CLI Configuration Guide for instructions on using those interfaces.
The links to these documents are in the C-Series documentation roadmap:
To install or replace hardware components, see the “Maintaining the Server” section on page 3-1.
OL-20887-02
Cisco UCS C210 Server Installation and Service Guide
2-11
NIC Modes and NIC Redundancy Settings
This server has the following NIC mode settings that you can choose from:
•Dedicated—The 10/100 management port is used to access the CIMC. You have to select a NIC
redundancy and IP setting.
•Shared LOM (default)—The two 1-Gb Ethernet ports are used to access the CIMC. This is the
factory default setting, along with Active-active NIC redundancy and DHCP enabled.
•Cisco Card—The ports on an installed Cisco network adapter card are used to access the CIMC. You
have to select a NIC redundancy and IP setting.
NoteThe Cisco Card NIC mode is currently supported only with a Cisco UCS P81E Virtual Interface
Card (N2XX-ACPCI01) that is installed in PCIe slot 1 (see
Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01),
page 3-37.
This server has the following NIC redundancy settings that you can choose from:
Chapter
Figure 3-18 on page 3-34). See also
•None—The Ethernet ports operate independently and do not fail over if there is a problem.
•Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
•Active-active—All Ethernet ports are utilized simultaneously.
The active/active setting uses Mode 5 or Balance-TLB (adaptive transmit load balancing). This is
channel bonding that does not require any special switch support. The outgoing traffic is distributed
according to the current load (computed relative to the speed) on each slave. Incoming traffic is
received by the current slave. If the receiving slave fails, another slave takes over the MAC address
of the failed receiving slave.
2-12
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02