Cisco 5000, NCS 5011, NCS 5002, NCS 5001, NCS 5064 Series Manual

Page 1
Overview
This chapter provides an overview of the Cisco 5000 Series routers.
The Network Convergence System 5000 Series offers a high-density, small-form-factor MPLS aggregation router for metro aggregation. It is designed to economically scale large enterprise, over-the-top (OTT), and service provider Data Center networking architectures.
Overview, on page 1
Cisco NCS 5001, on page 1
Cisco NCS 5002, on page 3
Cisco NCS 5011, on page 6
Cisco NCS 5064, on page 9
This chapter provides an overview of the Cisco 5000 Series routers.
The Network Convergence System 5000 Series offers a high-density, small-form-factor MPLS aggregation router for metro aggregation. It is designed to economically scale large enterprise, over-the-top (OTT), and service provider Data Center networking architectures.

Cisco NCS 5001

Cisco NCS 5001 Overview
The Cisco NCS 5001 router is an extension to Cisco's routing platform portfolio enabling Service Providers and MPLS enabled data center architectures to offer elastic networks with improved business agility and simplified operations to deliver high-bandwidth mobile, video, and cloud services.
It can also operate as an extension shelf of Cisco ASR 9000 Series Aggregation Services Routers using Network Virtualization (nV) technology, consolidating multiple layers in the network and dramatically reducing operational costs.
The Cisco NCS 5001 router is a small form factor dense GE/10GE aggregation systems. Powered by industry leading routing operation system, IOS-XR, the system also offers rich functions such as third party application hosting, machine-to-machine interface, telemetry and flexible package delivery.
Overview
1
Page 2
Cisco NCS 5001
Overview
Figure 1: Cisco NCS 5001 Router - Back (Fan Side) View
Figure 2: Cisco NCS 5001 Router - Front (Port Side) View
Ports
Cisco NCS 5001 router consists of the following ports:
• 40 x One GE/10GE SFP+ ports
• 16 x Regular 10G SFP+ Ports
• 24 x DWDM and ZR Capable 10G SFP+ Ports (Purple in color)
• 4 x 100G QSFP28 ports (Light Green in color)
Features
The Cisco NCS 5001 router has the following features:
• Two 1+1 redundant, hot-swappable power supplies, which provide port side intake or exhaust for cooling
• Two 1+1 redundant, hot-swappable fan modules, which provide port side intake or exhaust for cooling
• A management and console interface are on the port (front) side of the router whereas the USB interface on the fan (back) side of the router.
Power Supply
The Cisco NCS 5001 chassis has slots for two 1+1 redundant power supplies. Power supply options need to be configured with the base chassis. A minimum of one power supply is required for normal operation. The following table lists the power supplies that are configurable with the Cisco NCS 5001 router.
Overview
2
Page 3
Overview

Cisco NCS 5002

Table 1: Power Supplies for the Cisco NCS 5001 router
Power SupplyPart Number
Cisco NCS 5000 Power DC 930W Front to Back AirflowNC5K-PDC-930W-FR
Cisco NCS 5000 Power DC 930W Front to Back Airflow, spareNC5K-PDC-930W-FR=
Cisco NCS 5000 Power DC 930W Back to Front AirflowNC5K-PDC-930W-BK
Cisco NCS 5000 Power DC 930W Back to Front Airflow, spareNC5K-PDC-930W-BK=
Cisco NCS 5000 Series Router Power AC 650W Front to Back AirflowNC5K-PAC-650W-FR
NC5K-PAC-650W-FR=
Cisco NCS 5000 Series Router Power AC 650W Front to Back Airflow, spare
Cisco NCS 5000 Series Router Power AC 650W Back to Front AirflowNC5K-PAC-650W-BK
NC5K-PAC-650W-BK=
Cisco NCS 5000 Series Router Power AC 650W Back to Front Airflow, spare
Fan Modules
The Cisco NCS 5001 chassis has slots for two 1+1 redundant fan modules. The fan modules are hot-swappable. Fan modules operate in an 1+1 redundancy mode. Fan options need to be configured with the base chassis. The Cisco NCS 5001 system supports both forward and reverse airflow. The system can work with a single fan failure. More than one fan failure leads to system shutdown. The following table lists the fan modules that are configurable with the Cisco NCS 5001 router.
Table 2: Fan Modules for the Cisco NCS 5001 router
Fan ModulePart Number
Cisco NCS 5001 Router Fan Front to Back AirflowNCS-5001-FN-FR
Cisco NCS 5001 Router Fan Front to Back Airflow, spareNCS-5001-FN-FR=
Cisco NCS 5001 Router Fan Back to Front AirflowNCS-5001-FN-BK
Cisco NCS 5001 Router Fan Back to Front Airflow, spareNCS-5001-FN-BK =
Cisco NCS 5002
Cisco NCS 5002
The Cisco NCS 5002 router is also an extension to Cisco's routing platform portfolio enabling Service Providers and MPLS enabled data center architectures to offer elastic networks with improved business agility and simplified operations to deliver high-bandwidth mobile, video, and cloud services.
It can also operate as an extension shelf of Cisco ASR 9000 Series Aggregation Services Routers using Network Virtualization (nV) technology, consolidating multiple layers in the network and dramatically reducing operational costs.
Overview
3
Page 4
Cisco NCS 5002
Overview
The Cisco NCS 5002 router is a small form factor dense GE/10GE aggregation systems in 2RU form factor. Powered by industry leading routing operation system, IOS-XR, the system also offers rich functions such as third party application hosting, machine-to-machine interface, telemetry and flexible package delivery.
Figure 3: Cisco NCS 5002 - Back (Fan Side) View
Figure 4: Cisco NCS 5002 - Front (Port Side) View
Ports
Cisco NCS 5002 router consists of the following ports:
• 80 x One GE/10GE SFP+ ports
• 40 x Regular 10G SFP+ Ports, on baseboard
• 40 x DWDM and ZR Capable 10G SFP+ Ports, on mezzanine (Cisco Metallic Grey in color)
• 4 x 100G QSFP28 ports (Light Green in color)
Features
The Cisco NCS 5002 router has the following features:
• Two 1+1 redundant, hot-swappable power supplies, which provide port side intake or exhaust for cooling
• Two 1+1 redundant, hot-swappable fan modules, which provide port side intake or exhaust for cooling
• A management, console, and the USB interface on the port (front) side of the router
Overview
4
Page 5
Overview
Cisco NCS 5002
Power Supply
The Cisco NCS 5002 chassis has slots for two 1+1 redundant power supplies. Power supply options need to be configured with the base chassis. A minimum of one power supply is required for normal operation. The following table lists the power supplies that are configurable with the Cisco NCS 5002 router.
Table 3: Power Supplies for the Cisco NCS 5002 router
Power SupplyPart Number
Cisco NCS 5000 Power DC 930W Front to Back AirflowNC5K-PDC-930W-FR
Cisco NCS 5000 Power DC 930W Front to Back Airflow, spareNC5K-PDC-930W-FR=
Cisco NCS 5000 Power DC 930W Back to Front AirflowNC5K-PDC-930W-BK
Cisco NCS 5000 Power DC 930W Back to Front Airflow, spareNC5K-PDC-930W-BK=
NC5K-PAC-650W-FR
Cisco NCS 5000 Series Router Power AC 650W Front to Back Airflow
NC5K-PAC-650W-FR=
Cisco NCS 5000 Series Router Power AC 650W Front to Back Airflow, spare
NC5K-PAC-650W-BK
Cisco NCS 5000 Series Router Power AC 650W Back to Front Airflow
NC5K-PAC-650W-BK=
Cisco NCS 5000 Series Router Power AC 650W Back to Front Airflow, spare
Fan Modules
The Cisco NCS 5002 chassis has slots for two 1+1 redundant fan modules. The fan modules are hot-swappable. Fan modules operate in an 1+1 redundancy mode. Fan options need to be configured with the base chassis. The Cisco NCS 5002 system supports both forward and reverse airflow. The system can work with a single fan failure. More than one fan failure leads to system shutdown. The following table lists the fan modules that are configurable with the Cisco NCS 5002 router.
Table 4: Fan Modules for the Cisco NCS 5002 router
Fan ModulePart Number
NCS-5002-FN-FR
Cisco NCS 5002 Router Fan Front to Back Airflow
NCS-5002-FN-FR=
NCS-5002-FN-BK
NCS-5002-FN-BK=
Cisco NCS 5002 Router Fan Front to Back Airflow, spare
Cisco NCS 5002 Router Fan Back to Front Airflow
Cisco NCS 5002 Router Fan Back to Front Airflow, spare
Overview
5
Page 6

Cisco NCS 5011

Cisco NCS 5011
Cisco NCS 5011
The Cisco NCS 5011 router is also an extension to Cisco's routing platform portfolio enabling Service Providers and MPLS enabled data center architectures to offer elastic networks with improved business agility and simplified operations to deliver high-bandwidth mobile, video, and cloud services.
The Cisco NCS 5011 router consists of 32 QSFP+/QSFP28 ports. The NCS 5011 system supports 10GE, 25GE, 40GE, 50GE, and 100GE.
The Cisco NCS 5011 system extends 4x10G, 4x25G, and 2x50G breakout support for Copper Optics.
Configure Breakout
Log into the router in the config mode, and type the following command (in this example, the breakout optics is inserted in port 0):
RP/0/RP0/CPU0:router(config)# controller optics 0/0/0/0 breakout 4x10 RP/0/RP0/CPU0:router(config)# controller optics 0/0/0/0 breakout 4x25 RP/0/RP0/CPU0:router(config)# controller optics 0/0/0/0 breakout 2x50
Overview
Note
• The broken out interfaces are named as follows:
• tenGigE 0/0/0/0/0, tenGigE 0/0/0/0/1, tenGigE 0/0/0/0/2, and tenGigE 0/0/0/0/3
• twentyFiveGigE 0/0/0/0/0, twentyFiveGigE 0/0/0/0/1, twentyFiveGigE 0/0/0/0/2, and twentyFiveGigE 0/0/0/0/3
• FiftyGigE 0/0/0/0/0, FiftyGigE 0/0/0/0/1
• The above commands fail if the optics inserted do not support breakout. Only copper optics are currently supported.
• The commands succeed if there are no optics inserted, and the breakout is executed whenever optics are inserted at a later stage.
Overview
6
Page 7
Overview
Cisco NCS 5011
Figure 5: Cisco NCS 5011 - Back (Fan Side) View
Figure 6: Cisco NCS 5011 - Front (Port Side) View
Ports
Cisco NCS 5011 router consists of the following ports:
• 2 x 10GE SFP + ports
• 32 x 100G QSFP28-100 ports
Features
The Cisco NCS 5011 router has the following features:
• Two 1+1 redundant, hot-swappable power supplies, which provide port side intake or exhaust for cooling
• Four 3+1 redundant, hot-swappable fan modules, which provide port side intake or exhaust for cooling
• A management, console, and the USB interface on fan side of the router
Overview
7
Page 8
Cisco NCS 5011
Overview
Power Supply
The Cisco NCS 5011 chassis has slots for two 1+1 redundant power supplies. Power supply options need to be configured with the base chassis. A minimum of one power supply is required for normal operation. The following table lists the power supplies that are configurable with the Cisco NCS 5011 router.
Table 5: Power Supplies for the Cisco NCS 5011 router
Power SupplyPart Number
Cisco NCS 5000 Power DC 930W Front to Back AirflowNC5K-PDC-930W-FR
Cisco NCS 5000 Power DC 930W Front to Back Airflow, spareNC5K-PDC-930W-FR=
Cisco NCS 5000 Power DC 930W Back to Front AirflowNC5K-PDC-930W-BK
Cisco NCS 5000 Power DC 930W Back to Front Airflow, spareNC5K-PDC-930W-BK=
NC5K-PAC-650W-FR
Cisco NCS 5000 Series Router Power AC 650W Front to Back Airflow
NC5K-PAC-650W-FR=
Cisco NCS 5000 Series Router Power AC 650W Front to Back Airflow, spare
NC5K-PAC-650W-BK
Cisco NCS 5000 Series Router Power AC 650W Back to Front Airflow
NC5K-PAC-650W-BK=
Cisco NCS 5000 Series Router Power AC 650W Back to Front Airflow, spare
Fan Modules
The Cisco NCS 5011 chassis has slots for four 3+1 redundant fan modules. The fan modules are hot-swappable. Fan options need to be configured with the base chassis. The Cisco NCS 5011 system supports both forward and reverse airflow. The system can work with a single fan failure. More than one fan failure leads to system shutdown. The following table lists the fan modules that are configurable with the Cisco NCS 5011 router.
Table 6: Fan Modules for the Cisco NCS 5011 router
Fan ModulePart Number
NCS-5011-FN-FR
Cisco NCS 5011 Router Fan Front to Back Airflow
NCS-5011-FN-FR=
Cisco NCS 5011 Router Fan Front to Back Airflow, spare
NCS-5011-FN-BK
Cisco NCS 5011 Router Fan Back to Front Airflow
NCS-5011-FN-BK=
Cisco NCS 5011 Router Fan Back to Front Airflow, spare
Overview
8
Page 9
Overview

Cisco NCS 5064

The Cisco NCS 5064 router, which is also an extension to Cisco's routing platform portfolio enabling Service Providers and MPLS enabled data center architectures to offer elastic networks with improved business agility and simplified operations to deliver high-bandwidth mobile, video, and cloud services.
The Cisco NCS 5064 router is a small form factor dense 100GE aggregation systems in 2RU form factor. Powered by industry leading routing operation system, IOS-XR, the system also offers rich functions such as third party application hosting, machine-to-machine interface, telemetry and flexible package delivery.
Figure 7: Cisco NCS 5064 - Back (Fan Side) View
Cisco NCS 5064
Figure 8: Cisco NCS 5604 - Front (Port Side) View
Overview
9
Page 10
Cisco NCS 5064
Overview
Ports
Figure 9: Cisco NCS 5604 Port Label
• 64 QSFP28 ports with the capability of operating at 100G and 40G rates.
• Ports 0-15 also support dynamic breakout with these combinations: 4x10G, 4x25G, and 2x50G.
• Ports 48-63 may also support MACsec in a future release.
• 2 x 10GE SFP+ ports (although physically present, these are not supported by IOS-XR).
Configure Breakout
Log into the router in the config mode, and type the following command (in this example, the breakout optics is inserted in port 0):
RP/0/RP0/CPU0:router(config)# controller optics 0/0/0/0 breakout 4x10 RP/0/RP0/CPU0:router(config)# controller optics 0/0/0/0 breakout 4x25 RP/0/RP0/CPU0:router(config)# controller optics 0/0/0/0 breakout 2x50
Note
• The broken out QSFP interface will be named as following, depending on the break out mode:
• 4x10G: TenGigE 0/0/0/0/0, TenGigE 0/0/0/0/1, TenGigE 0/0/0/0/2, and TenGigE 0/0/0/0/3
• 4x25G: TwentyFiveGigE 0/0/0/0/0, TwentyFiveGigE 0/0/0/0/1, TwentyFiveGigE 0/0/0/0/2, and TwentyFiveGigE 0/0/0/0/3
• 2x50G: FiftyGigE 0/0/0/0/0, FiftyGigE 0/0/0/0/1
• The above commands fail if the optics inserted do not support breakout.
• The commands succeed if there are no optics inserted, and the breakout is executed whenever optics are inserted at a later stage.
• For 4x10 breakout, copper and non-copper optics are also supported.
For 4x10 breakout, the supported optics type are : 40G SR4, 40G LR, 40G AOC, 40G PSM, 40G AC (active copper), and 40G CR4 (passive copper).
Features
The Cisco NCS 5064 router has the following features:
Overview
10
Page 11
Overview
Cisco NCS 5064
• Two hot-swappable power supply (PSUs) that support 1+1 redundancy under most conditions. Only when the 930W DC supplies (NC5K-PDC-930W-FR and NC5K-PDC-930W-BK) are used, both the PSUs must be inserted and operational in a non-redundant 2+0 mode.
• Different power supply units (PSUs) are available for different air flow configurations.
• Three hot-swappable fan modules that provide port side intake or port side exhaust cooling in 2+1 redundancy mode.
• A management, console, and the USB interface on fan side of the router.
Power Supply
The Cisco NCS 5064 chassis has slots for two 1+1 redundant power supplies. Power supply options need to be configured with the base chassis. A minimum of one power supply is required for normal operation.
Caution
When 930W DC power supply (NC5K-PDC-930W-BK or NC5K-PDC-930W-FR) is used, redundancy is not supported.
The following table lists the power supplies that are configurable with the Cisco NCS 5064 router.
Table 7: Power Supplies for the Cisco NCS 5064 router and Redundancy Support Matrix
2+0 Non-Redundant Mode
YesNoNoRedCisco NCS
NC5K-PDC-930W-FR
ColorPower SupplyPart Number
1+0 Non-Redundant Mode
1+1 Redundant Mode
5000 Power DC 930W Front to Back Airflow
NC5K-PDC-930W-BK
YesNoNoBlueCisco NCS 5000 Power DC 930W Back to Front Airflow
NC5K-PAC-1200W-FR
NoYesYesRedCisco NCS 5000 Power AC 1200W Front to Back Airflow
NC55-1200W-ACFW
NC5K-PUV-1200W
NoYesYesBlueCisco NCS 5000 Series Router Power AC 1200W
NoYesYesWhiteCisco NCS 5000 Power HVAC/DC 1200W Bi-direcitonal Airflow
Overview
11
Page 12
Cisco NCS 5064
Overview
Fan Modules
The Cisco NCS 5064 chassis has slots for three 2+1 redundant fan modules. The fan modules are hot-swappable. Fan options need to be configured with the base chassis. The Cisco NCS 5064 system supports both forward and reverse airflow. The system can work with a single fan failure. More than one fan failure leads to system shutdown. The following table lists the fan modules that are configurable with the Cisco NCS 5064 router.
To replace the fan module, see the (Only for NCS 5064) Replacing a 2 (RU) Fan Module procedure.
Table 8: Fan Modules for the Cisco NCS 5064 router
ColorFan ModulePart Number
RedCisco NCS 5064 Router Fan Front to Back AirflowNCS-5064-FN-FR
BlueCisco NCS 5064 Router Fan Back to Front AirflowNCS-5064-FN-BK
System Air flow
Power supplies and fan modules must maintain the same air flow direction. The airflow direction can be identified based on the PID description and the handle color of both power supplies and fan modules.
Note, however, that the NC5K-PUV-1200W power supply can operate in both (front to back and back to front) air flow directions. When this power supply is used, the Cisco IOS-XR software automatically configures the PSU fan direction, based on the system fan modules that are inserted in the chassis. Do not mix power supplies and fan modules with different air flow directions. Such mixing leads to a system shutdown.
Do not mix power supplies and fan modules with different air flow directions. This will lead to a system shutdown.
Note
Filters are not mandatory. At any given time, the system may have either a port side intake filter or a port side exhaust filter, and not both.
Overview
12
Loading...