This publication describes how to install and verify the operation of the Catalyst 4500 E-series
Supervisor Engine 6L-E. Refer to the software configuration guide for your switch for configuration
information for the supervisor engines and switching modules.
NoteCatalyst 4500 E-series switching modules require an E-Series Supervisor Engine running a software
Contents
image compatible with that supervisor engine. Refer to your switch’s release notes for compatibility
information.
This document contains these sections:
• Safety Overview, page 2
• Supervisor Engine 6L-E, page 7
• Port Cabling Specifications, page 12
• Installing the Supervisor Engine, page 15
• Memory Upgrade, page 18
• Attaching Module Interface Cables, page 23
• Configuring Your Supervisor Engine, page 25
• X2 Installation, page 25
• Related Documentation, page 27
• Obtaining Documentation and Submitting a Service Request, page 28
Americas Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Throughout this publication, safety warnings appear in procedures that can harm you if performed
incorrectly. A warning symbol precedes each warning statement.
Warning
Waarschuwing
Varoitus
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device.
SAVE THESE INSTRUCTIONS
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan
veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij
elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard
praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de
waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt
raadplegen.
BEWAAR DEZE INSTRUCTIES
TÄRKEITÄ TURVALLISUUSOHJEITA
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin
käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu
onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen
mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien
lausuntonumeroiden avulla.
Statement 1071
2
SÄILYTÄ NÄMÄ OHJEET
Attention
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant
entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez
conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures
couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des
avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS
OL-19334-02
Safety Overview
Warnung
Avvertenza
Advarsel
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen
kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und
den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder
Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
IMPORTANTI ISTRUZIONI SULLA SICUREZZA
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle
persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli
relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti.
Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le
traduzioni delle avvertenze riportate in questo documento.
CONSERVARE QUESTE ISTRUZIONI
VIKTIGE SIKKERHETSINSTRUKSJONER
Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du
begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med
elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten
av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne
enheten.
Aviso
¡Advertencia!
TA VARE PÅ DISSE INSTRUKSJONENE
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de
lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos
perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de
prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para
localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo.
GUARDE ESTAS INSTRUÇÕES
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular
cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los
procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el
número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña
a este dispositivo.
GUARDE ESTAS INSTRUCCIONES
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
3
Safety Overview
Varning!
VIKTIGA SÄKERHETSANVISNINGAR
Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada.
Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och
känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av
varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna
anordning.
SPARA DESSA ANVISNINGAR
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
4
OL-19334-02
Safety Overview
Aviso
Advarsel
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões
corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os
circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o
número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de
segurança traduzidos que acompanham o dispositivo.
GUARDE ESTAS INSTRUÇÕES
VIGTIGE SIKKERHEDSANVISNINGER
Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for
legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de
involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til
undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de
oversatte advarsler, der fulgte med denne enhed.
GEM DISSE ANVISNINGER
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
5
Safety Overview
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
6
OL-19334-02
Supervisor Engine 6L-E
Supervisor Engine 6L-E
This section describes the Catalyst 4500 E-series Supervisor Engine 6L-E (WS-X45-SUP6L-E). See
Figure 1. This supervisor engine provides IPv6 data path and data control for all Layer 2 network
interfaces, and provides 10-Gigabit Ethernet interfaces for uplinks.
The Supervisor Engine 6L-E is supported in the Catalyst 4503, 4506, 4507R, 4503-E, 4506-E, and
4507R-E switches. On the Catalyst 4503, 4503-E, 4506, and 4506-E switches, you can install the
Supervisor Engine 6L-E only in slot 1. On the Catalyst 4507R switch, you install the primary supervisor
engine in slot 1, and you can install an optional redundant supervisor engine in slot 2. On the Catalyst
4507R-E switch, you install the primary supervisor engine in slot 3, and you can install an optional
redundant supervisor engine in slot 4. The supervisor engines in a redundant system must be of the same
type.
The supervisor engine is hot swappable, but packets are not forwarded when the last supervisor engine
has been removed from the switch. When a supervisor engine is reinserted into the switch, the supervisor
engine reboots.
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
LinkIndicates the status of the 10/100/1000 BASE-T Ethernet
ActiveIndicates whether the uplink port is active.
10-Gigabit Ethernet Uplink Ports
The 10-Gigabit Ethernet uplink ports operate in full-duplex mode only. These ports use the
hot-swappable X2 optical transceivers. The X2s have SC connectors to interface with multimode fiber
(MMF) and single-mode fiber (SMF) cable. For further information on X2s, see the “X2 Installation”
section on page 25.
When two Supervisor Engine 6L-Es are present in a Catalyst 4507R or Catalyst 4507R-E switch, one
X2 uplink is active on both the primary (active) and secondary (standby) supervisor engines by default,
or two uplinks will be active in a nonredundant configuration.
management port or uplink ports.
GreenThe link is operational.
OrangeThe link is disabled by user.
Flashing orange The power-on self-test indicates a faulty port.
OffNo signal is detected or there is a link configuration failure.
GreenThe port is active.
OffThe port is not active.
Gigabit Ethernet SFP Uplink Ports
If you want to use SFPs instead of X2s as your uplink transceivers, you can use the Cisco TwinGig
converter modules already provided in the X2 slots. Installation documentation for Cisco TwinGig
converter modules can be found at:
NoteThe 10-Gigabit Ethernet ports default to operating at 10-Gigabit, and will need to be configured in
Software to use the Cisco TwinGig converter modules. For details on this configuration change, refer to
the chapter on configuring interfaces in the configuration guide for your software release.
Ethernet Management Port
The Ethernet management port, also referred to as the Fa1 or fastethernet1 port, is a Layer 3 host port
to which you can connect a PC. You can use the Ethernet management port instead of the switch console
port for network management. When managing a switch, connect the PC to the Ethernet management
port on a Catalyst 4500 series switch. (Figure 2).
NoteWhen connecting a PC to the Ethernet management port, you must assign an IP address.
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
10
OL-19334-02
Supervisor Engine 6L-E
157549
Switch
PC
Network
cloud
Ethernet
management
port
Network
ports
157551
Switch
PC
Network
cloud
Network
cloud
Ethernet
management
port
Network
ports
Figure 2Connecting a Switch to a PC
By default, the Ethernet management port is enabled. The switch cannot route packets from the Ethernet
management port to a network port, and from the network port to the Ethernet port. To obtain these, the
Fa1 interface is automatically placed in a separate routing domain (or VRF domain), called mgmtVrf.
(You observe the ip Vrf forwarding mgmtVrf line in the running configuration when you boot up.)
Even though the Ethernet management port does not support routing, you might need to enable routing
protocols on the port. As illustrated in Figure 3, you must enable routing protocols on the Ethernet
management port when the PC is multiple hops away from the switch and the packets must pass through
multiple Layer 3 devices to reach the PC.
Figure 3Network Example with Routing Protocols Enabled
The specific implementation of Ethernet management port depends on the redundancy model you are
applying.
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
11
Port Cabling Specifications
Console Port
NoteEIA/TIA-232 was known as recommended standard RS-232 before its acceptance as a standard by the
Reset Button
NoteUse a paper clip or other small, pointed object to press the Reset button.
The Catalyst 4500 E-series Supervisor Engine 6L-E console port has an EIA/TIA-232 RJ-45 connector.
The console port allows you to perform the following functions:
• Configure the switch from the CLI
• Monitor network statistics and errors
• Configure SNMP agent parameters
Electronic Industries Alliance (EIA) and Telecommunications Industry Association (TIA).
The Reset button is used to restart the switch.
Compact Flash Port
The Flash port accepts both 64 MB and 128 MB Type 1 CompactFlash cards. You can use it for file
transfer tasks such as loading a new software image. The Flash card is optional and can be obtained from
third-party suppliers.
For more information, refer to Using the Compact Flash on the Catalyst 4500 Series Supervisor Engines
at the following URL:
This section provides port cabling specifications and includes the following subsections:
• Maximum Cable Distances, page 13
• Removing the Supervisor Engine, page 13
The length of your networks and the distances between connections depend on the type of signal, the
signal speed, and the transmission medium (the type of cabling used to transmit the signals). The
distance and rate limits in this document are the IEEE-recommended maximum speeds and distances for
signaling. Table 2 shows the transmission speed versus the distance.
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
12
OL-19334-02
Table 2EIA/TIA-232 Transmission Speed in Contrast with Distance
Rate (bps)Distance (ft)Distance (m)
240020060
480010030
96005015
19,200257.6
38,400123.7
Maximum Cable Distances
Table 3 shows the maximum cable distances for transceiver speed and cable type.
Table 3Maximum Cable Distances
Removing the Supervisor Engine
Transceiver
Speed (Mbps)Cable TypeDuplex Mode
10 Category 3 UTPHalf or full328 ft (100 m)
100 Category 5 UTPHalf or full328 ft (100 m)
1000 Category 5 UTPHalf or full328 ft (100 m)
1000SMFHalf or full43.4 to 62 mi (70 to 100 km)
1000MMFFull1804 ft (550 m)
10 GBSMFHalf or full24.84 mi (40 km)
10 GBMMFFull984.3 ft (300 m)
Removing the Supervisor Engine
All Catalyst 4500 series switches support hot swapping, which lets you install, remove, replace, and
rearrange supervisor engines and switching modules without powering the system off. When the system
detects that a switching module has been installed or removed, it runs diagnostic and discovery routines
automatically, acknowledges the presence or absence of the module, and resumes system operation with
no operator intervention.
This section contains the following subsections:
• Required Tools, page 14
Maximum Distance
Between Stations
• Installing the Supervisor Engine, page 15
• Removing the Supervisor Engine, page 17
NoteWhen installing modules in a chassis with empty slots, populate the upper empty slots first and work
down.
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
13
Removing the Supervisor Engine
Warning
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Required Tools
You will need these tools to install a supervisor engine in a Catalyst 4500 series switch:
• Number 1 and number 2 Phillips screwdrivers for the captive installation screws on most modules
• 3/16-in. flat-blade screwdriver for the captive installation screws on other modules
• Antistatic mat or antistatic foam
• Wrist strap or other grounding device
NoteWhenever you handle supervisor engines, use a wrist strap or other grounding device to prevent
electrostatic discharge (ESD) damage.
Preventing Electrostatic Discharge Damage
ESD damage, which can occur when electronic cards or components are improperly handled, results in
complete or intermittent failures. Port adapters and processor modules consist of printed circuit boards
that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral
components of the carrier. Although the metal carrier helps to protect the board from ESD, use a
preventive antistatic strap during handling.
Following are guidelines for preventing ESD damage:
• Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.
• Connect the equipment end of the strap to an unfinished chassis surface.
• When installing a component, use any available ejector levers or captive installation screws to
properly seat the bus connectors in the backplane or midplane. These devices prevent accidental
removal, provide proper grounding for the system, and help to ensure that bus connectors are
properly seated.
• When removing a component, use any available ejector levers or captive installation screws to
release the bus connectors from the backplane or midplane.
• Handle carriers by available handles or edges only; avoid touching the printed circuit boards or
connectors.
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
14
OL-19334-02
• Place a removed component board-side-up on an antistatic surface or in a static shielding container.
If you plan to return the component to the factory, immediately place it in a static shielding
container.
• Avoid contact between the printed circuit boards and clothing. The wrist strap only protects
components from ESD voltages on the body; ESD voltages on clothing can still cause damage.
• Never attempt to remove the printed circuit board from the metal carrier.
CautionFor safety, periodically check the resistance value of the antistatic strap. The measurement should be
between 1 and 10 megohm (Mohm).
Installing the Supervisor Engine
Catalyst 4500 series and Catalyst 4500 E-series switches have horizontal chassis slots that are numbered
from top to bottom. On the Catalyst 4503, 4503-E, Catalyst 4506, and 4506-E switches, you can install
the supervisor engine only in slot 1. On the Catalyst 4507R switch, you install the primary supervisor
engine in slot 1, and you can install an optional redundant supervisor engine in slot 2. On the Catalyst
4507R-E switch, you install the primary supervisor engine in slot 3, and you can install an optional
redundant supervisor engine in slot 4. The supervisor engines in a redundant system must be of the same
type.
Removing the Supervisor Engine
Warning
CautionTo prevent ESD damage, handle supervisor engines by the carrier edges only.
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing.
Statement 1034
To install a supervisor engine in a Catalyst 4500 E-series switch, follow this procedure:
Step 1Take the necessary precautions to prevent ESD damage as described in the installation guide for your
switch.
Step 2Ensure that you have enough clearance to accommodate any interface equipment that you will connect
directly to the supervisor engine ports.
Step 3Loosen the captive installation screws that secure the switching-module filler plate or the existing
supervisor engine (whichever is present) and remove it.
Step 4Remove the supervisor engine filler plate or the existing supervisor engine from slot 1. If a switching
module filler plate was installed, save it for future use. If you are removing an existing supervisor engine,
see the “Removing the Supervisor Engine” section on page 17.
Step 5To install the new supervisor engine, grasp the switching module front panel with one hand and place
your other hand under the carrier to support the supervisor engine, as shown in Figure 4. Do not touch
the printed circuit boards or connector pins.
Step 6Align the edges of the supervisor engine carrier with the slot guides on the sides of the switch chassis,
as shown in Figure 4.
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
15
Removing the Supervisor Engine
Figure 4Installing the Supervisor Engine in the Chassis (Catalyst 4506-E Shown)
4506
274485
Step 7
W
S
X
4
5-
S
u
p
6L
E
Pivot the two module ejector levers out and away from the faceplate.
Step 8Carefully slide the supervisor engine into the slot until the notches on both ejector levers engage the
chassis sides.
Step 9Using the thumb and forefinger of each hand, simultaneously pivot in both ejector levers to fully seat the
supervisor engine in the backplane connector.
CautionAlways use the ejector levers when installing or removing a supervisor engine. A supervisor engine that
is partially seated in the backplane will not function correctly.
Step 10Use a screwdriver to tighten the captive installation screws on each end of the supervisor engine
faceplate.
To check the status of the module, follow these steps:
Step 1Ensure that the LED labeled Status is green (module operational).
Step 2When the switch is online, enter the show module command. Verify that the system acknowledges the
new module and that the module’s status is good.
Step 3If the module is not operational, reseat it. If the module is still not operational, contact your customer
service representative.
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
16
OL-19334-02
Removing the Supervisor Engine
WS
X
45-
S
up6
L
E
S
TATU
S
RES
ET
A
C
T
I
VE
SU
P
U
T
ILIZ
A
T
ION
1%
100
%
COMP
A
CT
FLASH
UPL
I
N
K 1
X2 10Gb
E
U
PL
I
NK
1
A
CT
IVE
SFP
Gb
E
3
4
UP
L
I
N
K 1
X2
10Gb
E
U
PL
I
NK
A
CT
IVE
SFP
Gb
E
5
6
2
L
IN
K
10/100/
100
0
MGT
C
O
N
SOLE
E
˝
S
ERI
E
S
LIN
K
1
0
/10
0/1000
MGT
C
O
NS
O
L
E
E
˝
S
E
R
I
ES
1
2
274486
Removing the Supervisor Engine
Warning
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing.
Statement 1034
CautionTo prevent ESD damage, handle supervisor engines by the carrier edges only.
To remove a supervisor engine from a Catalyst 4500 E-series switch, follow this procedure:
Step 1Disconnect any network interface cables attached to the ports on the supervisor engine that you intend
to remove.
Step 2Loosen the captive installation screws (see Figure 5).
Figure 5Captive Installation Screws and Ejector Levers
1Ejector lever2Captive installation screw
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
17
Memory Upgrade
Step 3Grasp the left and right ejector levers and simultaneously pivot the levers outward to release the
Step 4Grasp the front panel of the supervisor engine with one hand and place your other hand under the carrier
Step 5Carefully pull the supervisor engine straight out of the slot, keeping your other hand under the carrier to
Step 6Place the supervisor engine on an antistatic mat or antistatic foam, or immediately install it in another
Step 7In chassis configured with redundant supervisor engines, if the chassis slot is to remain empty, you must
supervisor engine from the backplane connector. Figure 5 shows a close-up of the right ejector lever.
to support and guide it out of the slot. Do not touch the printed circuit boards or connector pins.
guide it.
slot.
install either a blank faceplate (C4K-SLOT-CVR) or a blank line card (C4K-SLOT-CVR-E). The
following guidelines explain when to use a blank faceplate and when to use a blank line card.
• If you have either a Catalyst 4507R or a Catalyst 4510R switch chassis, you must install the blank
line card (C4K-SLOT-CVR-E) rather than the blank faceplate to cover the empty chassis slot. A
blank faceplate does not direct sufficient airflow to adequately cool the remaining Supervisor
Engine 6L-E.
• If you have any other Catalyst 4500 series chassis, you can install the blank faceplate
(C4K-SLOT-CVR) over the empty chassis slot. The airflow is sufficient to adequately cool the
remaining Supervisor Engine 6L-E.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029
Memory Upgrade
This section describes how to perform a memory upgrade from a MEM-X45-512MB-LE (shipped with
the supervisor engine) to a MEM-X45-1GB-LE. You might need to upgrade memory on the Supervisor
Engine 6L-E for the following reasons:
• To upgrade to a new Cisco IOS feature set or release that requires additional memory. (Memory
requirements for each feature set and release are available in the release notes for that release.)
• To use very memory-intensive features.
This document describes how to upgrade dynamic memory. The Supervisor Engine 6L-E ships with
512 MB and can be upgraded to 1 GB in the form of an SDRAM SODIMM.
Tools and Equipment Needed
You need the following tools and equipment to remove and install DIMMs in a Supervisor Engine 6L-E:
• ESD-preventive wrist strap
• Antistatic mat
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
18
OL-19334-02
Performing a Memory Upgrade
274484
WS
X
45-
S
u
p6L-E
ST
ATU
S
RES
E
T
A
CT
I
V
E
SUP
U
TILIZA
T
ION
1%
100
%
C
OMP
A
C
T
FLASH
UPL
I
N
K
1
X
2
10Gb
E
U
PLI
NK
1
A
CT
I
VE
SFP
Gb
E
3
4
UPL
I
N
K 1
X2
10Gb
E
U
PLI
NK
A
CT
IVE
S
F
P
Gb
E
5
6
2
L
IN
K
1
0/100/
100
0
MGT
CONS
O
LE
E˝
S
E
RI
E
S
1
2
4
3
5
7
8
6
9
This procedure presumes you have already removed the supervisor engine from the switch, as described
in the “Removing the Supervisor Engine” section on page 17.
To upgrade the memory, follow these steps:
Step 1Attach an ESD-preventive wrist strap and ensure that it makes good contact with your skin. Connect the
equipment end of the wrist strap to the metal back plate of the chassis, avoiding contact with the
connectors.
Step 2On the mainboard, locate the DIMM module slot. The Supervisor Engine 6L-E has one slot, which
already has a MEM-X45-512MB-LE installed. (See callout 9 in Figure 6.)
1Status LED 4Utilization LEDs7Console port
2Reset button5Compact flash port8Management port
3Active Supervisor LED6Uplink ports9DIMM
CautionHandle the SODIMM by the edges only; do not touch the memory modules, pins, or traces (metal fingers
along the connector edge). Handle carefully. DIMMs are ESD-sensitive components and can be damaged
by mishandling.
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
19
Memory Upgrade
Step 3Release the plastic clips for the DIMM slot, and press down on them to unseat the 512 MB DIMM
module. (See Figure 7.)
Figure 7Removing DIMMs in the Supervisor Engine 6L-E
WS
X
45-
S
up6
L
E
S
TATU
S
RES
ET
A
C
T
I
VE
SU
P
U
T
ILIZ
1%
A
T
ION
100
%
COMP
A
CT
FLASH
X2 10Gb
E
UP
U
PL
L
I
NK
I
N
K 1
1
A
CT
IVE
X210Gb
SFP
Gb
E
E
UPL
U
PL
I
NK
IN
3
K 1
2
A
4
CT
IVE
SFP
Gb
E
C
5
O
NS
OLE
1
0
/100/1
6
MGT
00
0
E
˝SER
I
ES
L
IN
K
274906
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
20
OL-19334-02
Memory Upgrade
274907
CautionHandle the DIMM by the edges only; do not touch the memory modules, pins, or traces (metal fingers
along the connector edge). Handle carefully. DIMMs are ESD-sensitive components and can be damaged
by mishandling.
Step 4Hold the DIMM between your index fingers (See Figure 8). The DIMM is notched on the connection
edge, and there is a corresponding key on the memory slot, make sure they are oriented to seat correctly.
Figure 8Handling a DIMM
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
21
Memory Upgrade
Step 5Tilt the new 1 GB DIMM to the same angle as the socket, then insert the connector edge into the socket.
Gently push into place until the plastic clips snap into place. (See Figure 9.)
Figure 9Installing a DIMM
WS
-X45
-Su
p6L-E
ST
ATU
S
RES
E
T
A
CT
I
V
E
SUP
U
T
ILIZ
1%
A
T
ION
100
%
COMP
A
CT
FLASH
X2
10Gb
E
UPL
U
PLI
NK
I
N
K
1
1
A
CT
I
VE
X2
SFP
10Gb
Gb
E
E
U
U
PLI
P
L
NK
I
N
3
K 1
2
A
4
CT
I
VE
SFP
Gb
E
CONS
5
O
LE
10/100/
100
6
MGT
0
E˝
S
E
RI
E
S
L
IN
K
274908
CautionIt is normal to feel some resistance when installing a DIMM, but do not use excessive force and do not
touch the surface components.
Step 6Check the plastic clips for a secure and similar fit. If necessary, carefully remove and reseat the DIMM.
Step 7Replace the supervisor engine in the switch as described in the “Installing the Supervisor Engine”
section on page 15.
Step 8To verify the upgrade was successful, look for the following output lines in the bootup output, or in the
results of a show version console command:
cisco WS-C4506 (MPC8548) processor (revision 0) with 1048576K bytes of memory.
Processor board ID FOX104810F8
MPC8548 CPU at 1GHz, Supervisor 6L-E
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
22
OL-19334-02
192661
Pin 1
Pin 8
RJ-45 (both ends)
Attaching Module Interface Cables
Figure 10 and Figure 11 show the connector types used to attach interface cables to the supervisor
engine.
Figure 10RJ-45 Connector
Attaching Module Interface Cables
Warning
NoteAlways keep caps and plugs on the fiber-optic connectors on the cable and the switch when they are not
Warning
SC Connector
Warning
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network
voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some
LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables.
Statement 1021
in use.
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
The SC connector, shown in Figure 11, is used to connect fiber-optic module ports or transceivers with
the external SMF or MMF network.
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
NoteMake sure that the optical connectors are clean before making the connections. Contaminated connectors
can damage the fiber and cause data errors.
Always insert the network connector completely into the socket. A secure connection is especially
important when you are establishing a connection between a module and a long distance (1.24 miles)
(2 km) network or a module and a suspected highly attenuated network. If the link LED does not light,
try removing the network cable plug and reinserting it firmly into the module socket. It is possible that
dirt or skin oils have accumulated on the plug faceplate (around the optical-fiber openings), generating
significant attenuation and reducing the optical power levels below threshold levels so that a link cannot
be made.
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
23
Attaching Module Interface Cables
Cable
Plug
Receptacle
Keys
Receiver
Transmitter
Light out
of fiber
Light into
fiber
13087
Key slots
CautionUse extreme care when removing or installing connectors so that you do not damage the connector
housing or scratch the end-face surface of the fiber. Always install protective covers on unused or
disconnected components to prevent contamination. Always clean fiber connectors before installing
them.
Figure 11SC-Type Fiber-Optic Connector
LC Connector
Warning
NoteMake sure that the optical connectors are clean before making the connections. Contaminated connectors
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
The LC fiber-optic connector, shown in Figure 12, is a small form-factor fiber-optic connector that
provides high-density fiber connectivity. The LC connector can be used with either MMF cable or SMF
cable. The LC connector uses a latching clip mechanism that is similar to the one used on the RJ-45
copper connector.
can damage the fiber and cause data errors.
Figure 12LC Fiber-Optic Connector
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
24
OL-19334-02
Configuring Your Supervisor Engine
For information and commands to configure your supervisor engine, refer to the software configuration
guide for your switch. Configuration guides are located at:
An X2 transceiver is a hot swappable input/output device that plugs into the 10-Gigabit Ethernet port of
the supervisor engine and links the supervisor engine with a fiber-optic network. X2 transceivers are
online swappable.
Full documentation of the X2 transceiver is in the 10-Gigabit Ethernet X2 Transceiver Installation Note.
You may also use Cisco TwinGig and Cisco OneX converter modules in these ports. Installation
documentation for Cisco TwinGig converter modules can be found in the Installation Notes for the Cisco
TwinGig Converter Module.
For supported X2 transceiver media types, refer to:
CautionThe 10-Gigabit Ethernet X2 transceiver is a static-sensitive device. Always use an ESD wrist strap or
similar individual grounding device when handling X2 transceivers or coming into contact with
modules.
X2 Transceiver Maintenance Guidelines
To properly maintain X2 transceivers, follow these guidelines:
• To prevent ESD damage, follow normal handling procedures.
• When the transceiver is stored or when a fiber-optic cable is not plugged in, always keep plugs in
the optical bores.
• The most common source of contaminants in the optical bores is debris picked up on the ferrules of
the optical connectors. Use an alcohol swab or Kim-Wipe to clean the ferrules of the optical
connector.
Warning
OL-19334-02
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Statement 1051
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
25
SFP Guidelines
SFP Guidelines
The Supervisor Engine 6L-E has two X2 ports that can support Cisco TwinGig modules providing two
SFP connections to other network devices. You can have a total of four SFPs.
For installation information, refer to the Cisco SFP and SFP+ Transceiver Module Installation Notes.
Use only Cisco SFP modules on your Cisco device. Each SFP module has an internal serial EEPROM
that is encoded with security information. This encoding provides a way for Cisco to identify and
validate that the SFP module meets the requirements for the device.
For supported SFP transceiver media types, refer to:
Fiber-optic cable connectors can be damaged by improper cleaning and connection procedures. Dirty or
damaged fiber-optic connectors can result in communication that is not repeatable or inaccurate.
Fiber-optic connectors differ from electrical or microwave connectors. In a fiber-optic system, light is
transmitted through an extremely small fiber core. Because fiber cores are often 62.5 microns or less in
diameter, and dust particles range from a tenth of a micron to several microns in diameter, dust and any
contamination at the end of the fiber core can degrade the performance of the connector interface where
the two cores meet. Therefore, the connector must be precisely aligned, and the connector interface must
be absolutely free of trapped foreign material.
Connector loss, or insertion loss, is a critical performance characteristic of a fiber-optic connector.
Return loss is also an important factor. Return loss specifies the amount of reflected light; the lower the
reflection, the better the connection. The best physical contact connectors have return losses greater than
-40 dB, although -20 to -30 dB is more common.
The connection quality depends on two factors: the type of connector and the proper cleaning and
connection techniques. Dirty fiber connectors are a common source of light loss. Keep the connectors
clean at all times, and keep the dust covers installed when the connectors are not in use.
Before installing any type of cable or connector, use a lint-free alcohol pad from a cleaning kit to clean
the ferrule, the protective white tube around the fiber, and the end-face surface of the fiber.
As a general rule, whenever there is a significant, unexplained loss of light, clean the connectors.
CautionUse extreme care when removing or installing connectors so that you do not damage the connector
housing or scratch the end-face surface of the fiber. Always install protective covers on unused or
disconnected components to prevent contamination. Always clean fiber connectors before installing
them.
To clean the optical connectors, use a CLETOP cassette cleaner (type A for SC connectors or type B for
MT-RJ connectors) and follow the product directions. If a CLETOP cassette cleaner is not available,
follow these steps:
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
26
OL-19334-02
Related Documentation
Step 1Use a lint-free tissue soaked in 99 percent pure isopropyl alcohol to gently wipe the faceplate. Wait five
seconds for the surfaces to dry, and repeat.
Step 2Remove any residual dust from the faceplate with clean, dry, oil-free compressed air.
Warning
Step 3Use a magnifying glass or inspection microscope to inspect the ferrule at an angle. Do not look directly
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
into the aperture. Repeat the process if any contamination is detected.
The connectors used inside the system have been cleaned by the manufacturer and connected to the
adapters in the proper manner. The operation of the system should be error free if the customer provides
clean connectors on the application side, follows the previous directions, and follows these guidelines:
• Clean the connectors using either a CLETOP cassette cleaner (Type A for SC connectors and Type
B for MT-RJ connectors) or lens tissues before connecting to the adapters. Use pure alcohol to
remove contamination.
• Do not clean the inside of the connector adapters.
• Do not use force or quick movements when connecting the fiber-optic connectors in the adapters.
• Cover the connectors and adapters to keep the inside of the adapters or the surface of the connectors
from getting dirty when you are not using the connectors or while you are cleaning the chassis.
Related Documentation
For more detailed installation and configuration information, refer to the following:
• Inspection and Cleaning Procedures for Fiber-Optic Connections
• Installation Notes for the Cisco TwinGig Converter Module
OL-19334-02
Installation and Configuration Note for the Cisco Catalyst 4500 E-Series Supervisor Engine 6L-E
27
Related Documentation
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, using the Cisco Bug Search Tool (BST), submitting a
service request, and gathering additional information, see What’s New in Cisco Product Documentation
at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html.
Subscribe to What’s New in Cisco Product Documentation, which lists all new and revised Cisco technical
documentation, as an RSS feed and deliver content directly to your desktop using a reader application. The
RSS feeds are a free service.
This document is to be used in conjunction with the publications documents that support your specific Cisco device.
CCDE, CCENT, CCSI, Cisco Eos, Cisco HealthPresence, Cisco IronPort, the Cisco logo, Cisco Lumin, Cisco Nexus, Cisco Nurse Connect,
Cisco Pulse, Cisco StackPower, Cisco StadiumVision, Cisco TelePresence, Cisco Unified Computing System, Cisco WebEx, DCE, Flip Channels,
Flip for Good, Flip Mino, Flipshare (Design), Flip Ultra, Flip Video, Flip Video (Design), Instant Broadband, and Welcome to the Human Network
are trademarks; Changing the Way We Work, Live, Play, and Learn, Cisco Capital, Cisco Capital (Design), Cisco:Financed (Stylized), Cisco Store,
and Flip Gift Card are service marks; and Access Registrar, Aironet, AllTouch, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP,
CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems,
Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, Continuum, EtherFast, EtherSwitch, Event Center,
Explorer, Fast Step, Follow Me Browsing, FormShare, GainMaker, GigaDrive, HomeLink, iLYNX, Internet Quotient, IOS, iPhone, iQuick Study,
IronPort, the IronPort logo, Laser Link, LightStream, Linksys, MediaTone, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers,
Networking Academy, Network Registrar, PCNow, PIX, PowerKEY, PowerPanels, PowerTV, PowerTV (Design), PowerVu, Prisma, ProConnect,
ROSA, ScriptShare, SenderBase, SMARTnet, Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx,
and the WebEx logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or website are the property of their respective owners. The use of the word partner does not imply
a partnership relationship between Cisco and any other company. (0908R)