To verify that the router has been successfully installed and connected to the network, use the show
interface command to confirm that the router Ethernet interface is up.
CGR1240> show interface
Ethernet0 is up, line protocol is up
Hardware is Cisco, address is 0019.076c.1a78 (bia 0019.076c.1a78)
Internet address is 192.0.2.111/23
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec)
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 5/75, 32 drops
5 minute input rate 10000 bits/sec, 27 packets/sec
5 minute output rate 10000 bits/sec, 26 packets/sec
16076431 packets input, 1280716531 bytes, 27 no buffer
Received 1809290 broadcasts, 0 runts, 0 giants
1105 input errors, 0 CRC, 0 frame, 0 overrun, 1105 ignored, 0 abort
0 input packets with dribble condition detected
16196175 packets output, 1011044938 bytes, 0 underruns
19 output errors, 184 collisions, 3 interface resets
0 babbles, 0 late collision, 1474 deferred
19 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
Serial0 is administratively down, line protocol is down
Hardware is HD64570
MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, rely 255/255, load 1/255
Encapsulation HDLC, loopback not set, keepalive set (10 sec)
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Input queue: 0/75/0 (size/max/drops); Total output drops: 0
Queueing strategy: weighted fair
Output queue: 0/64/0 (size/threshold/drops)
Conversations 0/0 (active/max active)
Reserved Conversations 0/0 (allocated/max allocated)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 1 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions
DCD=down DSR=down DTR=down RTS=down CTS=down
Basic Hardware Installation
OL-26223-01
For more information about using the show interface command, see the Cisco 1000 Series Connected
Grid Routers Software Configuration Guide.
This section provides information about making other, additional router cable connections. Follow the
procedures in this section based on your network configuration and requirements. This section contains
these procedures:
•External Connections and Chassis Cable Ports, page 6-10
•Using Cable Glands, page 6-11
•Connecting the Console Port, page 6-15
•Connecting the Serial Port, page 6-16
•Connecting the USB Ports, page 6-17
•Connecting the SFP Ports, page 6-18
•Connecting the Ethernet Ports, page 6-20
•Connecting the Alarm Port, page 6-22
•Connecting the IRIG-B Port, page 6-23
Chapter 6 Installing the Router
External Connections and Chassis Cable Ports
When connecting the router internal ports to external cables or exterior devices, you must thread the
router cables through the chassis cable ports designated for this purpose. Some chassis ports are reserved
for specific cables and remaining ports can be used based on your network configuration and cabling
requirements.
There are nine cable ports on the chassis base and two ports on the chassis door (Figure 6-8). Some ports
are reserved for a specific cables types, as indicated Figure 6-8.
CautionWhen you make router cable connections through these ports, you must use cable glands as described in
Using Cable Glands, page 6-11, to protect the router interior from environmental elements, including
moisture, heat, cold, and dust. Failure to use cable glands with the chassis cable ports can result in
damage to the router.
1AdapterConnects directly to the chassis cable port on the router.
2GrommetSecures the split gasket over the cable
3Split gasketFits over the cable and creates an liquid-tight seal inside the glands.
4CapFits over gasket-and-cable assembly and connects it to the chassis cable port.
Cables used with the cable glands should meet the following criteria:
•Outdoor-rated
•UV-stabilized
•Plenum-rated
•Minimum 1/2 in. (12.7 mm) in diameter
CautionCables must be a minimum of 1/2 in. in diameter to create an adequate seal within the cable glands.
Using smaller cables could result in an inadequate seal and therefore expose the router interior to
environmental elements.
Cable Glands Installation Steps
Follow these steps for every cable that you will connect through the chassis cable ports on the router.
Step 4 and Step 5 can be done ahead of time and the prepared cable gland assembly can be transported
to the router installation site.
The cable glands components referred to in this section are shown in Figure 6-10.
Additional Router Connections
NoteFigure 6-12 shows an Ethernet cable but the steps are the same for all cable types.
Step 1Verify the cable you are using meets the requirements described in Cable Requirements, page 6-13.
Step 2Remove the liquid tight-seal from the port on the router. Use the 13-mm wrench if needed.
The router is shipped with liquid tight seals in unused ports. Figure 6-8 illustrates a liquid tight seal.
Step 3Use your hands to attach the cable glands adapter (item 1 in Figure 6-10) into the chassis cable port on
the router (Figure 6-11).
Step 4Thread the following cable glands components over the cable in this order (Figure 6-12):
1. Cap
2. Split gasket
3. Grommet
Step 5Slide the split gasket along the cable and into the grommet, pressing firmly to ensure the gasket is
completely seated in the grommet.
Step 6Thread the connector-end of the cable through the router port and insert it into the corresponding router
connector.
Step 7Slide the cap along the cable, over the grommet, and then over the router port. Hand-tighten, then use
the 13-mm wrench to tighten to 6-7 foot-pounds of torque.
To configure the router through the Cisco IOS command-line interface (CLI), you must establish a
connection between the router console port and either a terminal or a PC. The console port is located on
the router exterior (
Use this port to connect a PC terminal, enabling you to log directly into the router system software to
perform configuration or other commands.
CautionThe console port does not support cable glands. When a cable is connected to this port, the router interior
is exposed to environmental elements, which can damage the port and the router interior. This port
should be exposed only during terminal sessions, when a cable is connected to the port. This port should
never be left unattended when in use.
Figure 6-13Console Port Location
Figure 6-13) and is labeled CON.
Additional Router Connections
Connecting
OL-26223-01
This section describes how to connect a PC terminal to the console port.
When a terminal is connected to the console port, you can connect directly to the router and configure
it. You can connect a PC terminal to this port while the router is operating normally.
To connect a PC terminal to the router, you must provide:
•RJ-45-to-RJ-45 rollover cable
•One of the following adapters, depending on the device port: RJ-45-to-DB-25 female DTE adapter,
Follow these steps to connect a PC or PC terminal to the console port:
Step 1Connect one end of the RJ-45 cable to the console port on the router.
Step 2Connect the adapter you provide to the other end of the RJ-45 cable.
Step 3Connect the adapter end of the cable to the router.
Related Information
•For information about starting a terminal session over the console port with Microsoft Windows,
•For more information about this port, see the chapter Router Hardware Description.
Chapter 6 Installing the Router
RJ-45-to-DB-9 female DTE adapter (labeled TERMINAL), or USB-to-DB-9 adapter.
Mac
OS X, or Linux, see the appendix Starting a Router Terminal Session.
Connecting the Serial Port
NoteCurrently not supported. This hardware feature will be supported in a future software release.
About
Before you connect a device to the router serial port (Figure 6-14), you need to know the following:
•Type of device, data terminal equipment (DTE) or data communications equipment (DCE), you are
connecting to the synchronous serial interface
•Type of connector, male or female, required to connect to the device
•Signaling standard required by the device
These are the most common devices connected to the router serial ports:
Serial DeviceNetwork Options
Asynchronous modemAsynchronous
dial-up line
Network Encapsulation
(Framing)
Network Type
Point-to-Point (PPP)Remote location to data center
NoteCurrently not supported. This hardware feature will be supported in a future software release.
About
You can connect up to two optional USB devices to the router USB ports (Figure 6-15), which will
provide power to the USB devices. You can also connect USB devices that are powered by an external
source, such as an AC adapter or batteries.
Connecting
•You can connect devices to these ports while the router is operating normally.
•The USB ports are labeled 1 and 2 (with a USB icon).
•Depending on the USB devices you connect to these ports, you might require a USB extension cable
to connect devices to these ports.
Chapter 6 Installing the Router
•To prevent connected USB devices from being stolen or accidently removed, secure any connected
•When connecting to external USB devices, you must use cable glands and thread USB cables
Related Information
For detailed information about these ports, including supported USB standards and power output, see
the chapter
Figure 6-15USB Port Location
USB device with a locking mechanism designed for this purpose.
through the chassis cable ports on the router. See
Small Form-Factor Pluggable (SFP) modules are devices that plug into the router SFP connectors shown
in
Figure 6-16. The transceiver connects the electrical circuitry of the module with the optical or copper
network.
The SFP module used on each port must match the wavelength specifications on the other end of the
cable, and the cable must not exceed the stipulated cable length for reliable communications.
Use only Cisco SFP transceiver modules with the router. Each SFP transceiver module supports the
Cisco Quality Identification (ID) feature which allows a Cisco switch or router to identify and validate
that the transceiver module is certified and tested by Cisco.
Additional Router Connections
Warning
CautionDo not remove the dust plugs from the fiber-optic SFP module port or the rubber caps from the
CautionCisco recommends that you not install or remove the SFP module while the fiber-optic cable is attached
Class 1 laser product.
fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP module
ports and cables from contamination and ambient light.
to it because of the potential damage to the cables, to the cable connector, or to the optical interfaces in
the SFP module. Disconnect the cable before you remove or install an SFP module.
Materials and Tools You Supply
You must provide these tools and materials to install the SFP transceiver module:
•Wrist strap or other personal grounding device to prevent ESD occurrences.
•Antistatic mat or antistatic foam to set the transceiver on.
•Fiber-optic end-face cleaning tools and inspection equipment. For complete information on
inspecting and cleaning fiber-optic connections, see the white-paper document at this URL:
This section describes how to install SFP modules. SFP modules are inserted into the SFP ports shown
in
Figure 6-16.
Step 1Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.
Step 2For fiber-optic SFP modules, remove the dust plugs and store them in a clean location for reuse.
Step 3Position the SFP transceiver module in front of the socket opening, and insert the SFP into the socket
until you feel the connector latch into place.
Step 4Remove the dust plugs from the network interface cable LC connectors.
Step 5Inspect and clean the LC connector's fiber-optic end-faces.
Step 6Remove the dust plugs from the SFP transceiver module optical bores.
Step 7Thread the SFP cable through the chassis cable ports that are reserved for the SFP cables (Figure 6-8).
NoteYou must use cable glands with the chassis cable ports on the router. See External Connections and
Chassis Cable Ports, page 6-10.
Step 8Attach the network interface cable connector to the SFP transceiver module.
Related Information
•For supported SFP modules, see the chapter Router Hardware Description.
•For detailed information on connecting the SFP module cable to the network, see Cisco.com for the
The router features four Fast Ethernet (FE) ports and two Gigabit Ethernet (GE) ports for connecting the
router to an Ethernet network through a hub or switch (
Connecting
•See Figure 6-17 for the Ethernet port labels.
•You can connect SFP modules to these ports while the router is operating normally.
•One or two Ethernet cables are typically provided with the router. Additional cables and transceivers
can be ordered from Cisco. For ordering information, contact customer service.
•When the Ethernet ports, you must use cable glands and thread cables through the chassis cable ports
on the router. See
•The GE ports (ETH 2/1 and ETH 2/2) have identical labels to the SFP ports because the SFP ports
share physical ports with the GE ports. For detailed information about how to use these ports, see
Hot Swapping SFP Modules, page 2-25, in the chapter Router Hardware Description, page 2-1.
External Connections and Chassis Cable Ports, page 6-10 for more information
Additional Router Connections
Figure 6-17).
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Related Information
Router Hardware Description includes detailed information about these ports, including:
NoteCurrently not supported. This hardware feature will be supported in a future software release.
About
The alarm port provides data about fatal or severe errors that can cause the system software to crash.
The alarm port is connected to a normally closed solid state relay. Cisco IOS writes to a hardware port
and the relay contact opens. If the system enters into a ROM monitor (ROMmon) or watchdog reset state,
the relay contacts close. The closing contacts alert the alarm annunciator or monitor that a Cisco IOS
crash has occurred.
•Connect the IRIG port to an external device that requires precise time-of-the day information for
•You must provide the device and the cable for this connection.
•When connecting this port to an external device, you must use cable glands and thread cables
Related Information
Router Hardware Description includes detailed information about this port, including:
•Supported serial time code formats
•Location on the router
Figure 6-19IRIG-B Timing Port
synchronizing data with time.
through the chassis cable ports on the router. See
page 6-10 for more information
Chapter 6 Installing the Router
External Connections and Chassis Cable Ports,
Installing Modules and Antennas
The router supports up to four Cisco Connected Grid modules. Each module requires one or two
antennas, which are installed on or near the router. See these documents for detailed information about
installing Connected
URLs for these documents are TBD
•Connected Grid Antenna Installation Guide
•Cisco Connected Grid Cellular 3G Module for CGR1000 Series Installation and Configuration
Guide
•Cisco Connected Grid WiMAX Module for CGR1000 Series Installation and Configuration Guide
•Cisco Connected Grid WPAN Module for CGR1000 Series Installation and Configuration Guide
The Cisco 1240 Connected Grid Router supports up to four Cisco Connected Grid modules to enable
wireless connections from the router to field devices, such as smart meters, and from the router to the
utility or data management center.
Module Installation and Configuration Information
Depending on the configuration, your router could arrive in the shipping container with all required
modules already installed.
For instructions on how to install, replace, and configure the modules, see the corresponding installation
and configuration guide for each Cisco
URLs for these documents TBD.
Table 7-1Connected Grid Modules for CGR 1000 Series Routers Documentation
Connected Grid module.
7
Connected Grid ModuleRelated Documentation
Cisco Connected Grid Modules for
CGR 1000 Series – WiMax
Cisco Connected Grid Modules for
CGR 1000 Series – Cellular 3G
Cisco Connected Grid Modules for
CGR 1000 Series – WPAN
Cisco Connected Grid WiMAX Module for CGR 1000
Series Installation and Configuration Guide
Cisco Connected Grid Cellular 3G Module for CGR 1000
Series Installation and Configuration Guide
Cisco Connected Grid WPAN Module for CGR1000 Series
Installation and Configuration Guide
This chapter contains detailed information about the antennas for the
Cisco
1240 Connected Grid Router. Router antennas provide connectivity to the router internal GPS and
access point, as well as to any Cisco
This chapter contains the following sections:
•Installing or Replacing Antennas, page 8-1
•Antennas Overview, page 8-2
•Antenna Ports, page 8-5
•Safety Information, page 8-7
•Antenna Technical Specifications, page 8-7
Installing or Replacing Antennas
Connected Grid modules installed in the router.
CHAPTER
8
Depending on the configuration you specified, the router could arrive in the shipping container with all
required antennas already installed and connected to the corresponding Cisco
also installed in the router.
However, you might need to install an antenna when:
•You purchase a module separately from the router. The antenna is included with the module, and
must be installed on the router to complete the module installation.
•You purchase an antenna separately to replace a faulty or damaged antenna.
Procedures and safety information required to install or replace antennas are in the Connected Grid
Antennas Installation Guide:
Every external Connected Grid antenna that is installed on the router requires a lightning arrestor.
External antennas are any antennas that are connected to the router antenna port N-connector with a
cable.
You can order lightning arrestors from Cisco using Product ID (PID): CGR-LA-N-N.
The router ships with one omni-directional, monopole WiFi antenna already installed and connected
internally to the router internal short-range access point. The router WiFi link enables users to connect
to the router from anywhere within WiFi range. For example, a technician can check the status of the
router from the ground (instead of having to physically open the router on its poletop installation) by
remotely connecting to the router over the WiFi link.
The WiFi antenna is a field replaceable component. The Cisco Product ID (PID) for the Wifi antenna is
ANT-MP-INT-OUT-M.
•For detailed technical information about the WiFi antenna, see the section WiFi Antenna
Specifications, page 8-9.
•For information about the WiFi status LED, see the chapter Router LED Locations and States.
•For more information about the Short-Range Access Point, which provides the WiFi connection to
the router, see the chapter Router Hardware Description.
In addition to the two fixed antennas (GPS and WiFi), the router supports up to seven additional
antennas, which provide connectivity to the Connected
module requires one or two antennas, which are mounted on the exterior of the router and connected
through chassis antenna ports to the module installed inside the router.
The router supports up to four Cisco Connected Grid modules. Each module requires one antenna or two
antennas (one main antenna and one diversity antenna). Diversity antennas improve the quality and
reliability of the wireless connection. Because they are placed in different locations on the router, main
and diversity antennas detect different amounts of interference. The router uses the antenna with the
least interference to obtain the best signal.
The total number of antennas installed on the router depends on:
•Number of modules installed in the router.
•Module types that are installed in the router
For detailed information about the Connected Grid module antennas, see the Connected Grid Antennas
Installation Guide:
This section describes the antenna ports, and includes the following topics:
•Unused Antenna Ports, page 8-5
•Antenna Port Numbering, page 8-5
Unused Antenna Ports
Liquid-tight, female N-connectors are installed in any unused antenna ports. The N-connector protects
the router interior from environmental elements including water, heat, cold, and dust. The N-connectors
are installed in unused antenna ports before the router is shipped.
When you install or replace an antenna in a port with an N-connector:
•Chassis-mounted antennas—Remove the N-connector before installing a chassis-mounted antenna.
•External antennas—Connect the supported Cisco lightning arrestor to the N-connector, then connect
the antenna cable to the lightning arrestor.
Antenna Ports
For detailed instructions for installing antennas, Connected Grid Antennas Installation Guide:
Figure 8-3N-Connector Installed in Unused Antenna Port
Antenna Port Numbering
This section illustrates the antenna port locations on the router. Each antenna port is numbered. The
antenna port numbers should be referenced by installers, support technicians, and other end users when
installing, replacing, or troubleshooting the antennas.
CautionSupported Connected Grid antennas can be installed in any of the router antenna ports, however Cisco
recommends that antennas be installed in the locations recommended in the antenna installation guide.
Installing antennas in the recommend locations optimizes ease of installation, antenna performance. and
antenna cable management.
The recommended location for each antenna depends on several factors, including:
•The type and number of Connected Grid modules installed in the router
•The type and number of antennas required to support the installed modules
The procedures in the antenna installation guide refer to the port numbers illustrated in this section.
TypeActive GPS, chassis mounted
Frequency1575.42 MHz
Height22.1 mm
Base diameter50 mm
Maximum gain (dBi)5
PolarizationRHCP
Coaxial cable length10 in. (25.4 cm)
Coaxial cable type50 ohm, double-shielded
ConnectorSMA-male
EnvironmentOutdoor
Temperature range, operational -40 to 185° F (-40 to 85° C)
Temperature range, storage -40 to 185° F (-40 to 85° C)
Vertical
Coaxial cable length14.5 in. (5.7 cm)
Coaxial cable typeLMR195 double-shielded
ConnectorRight angle QMA-male
Temperature range, operational-40 to 185° F (-40 to 85° C)
Temperature range, storage -40 to 185° F (-40 to 85° C)
Maximum input power10 W (avg.)
This chapter describes the Secure Digital (SD) flash memory module (or SD card) that is used with the
Cisco 1240 Connected Grid Router, and includes instructions for installing and removing the SD card.
This chapter contains the following sections:
•SD Card Overview, page 9-1
•Supported SD Cards, page 9-2
•Inserting the SD Card, page 9-3
•SD Card Status, page 9-6
•Related Commands, page 9-7
SD Card Overview
CHAPTER
9
The Cisco 1240 Connected Grid Router features an SD card connector, which supports a single Cisco SD
card. The SD card stores router data and software, including:
•Router operating software
•Running configurations
•Network management software configuration
•Network registration data
•Router firmware
•Billing data
•Outage data
•Event data
SD Card File System
The SD card uses a Linux-based EXT2/3 file system. The router configuration is stored in a binary file
in an invisible partition on the card.
Sharing SD Cards Across Systems
The card cannot be used to configure or operate any system other than the system with which is it
shipped.
Table 9-1 lists the SD cards that can be used with the router.
Table 9-1Supported SD Flash Modules
Chapter 9 Using the SD Flash Memory Module
Cisco Part Number
16-3704-011 GB
16-3795-012 GB
16-3798-014 GB
1. At FCS, these internal part numbers must be replaced with customer-facing Product ID (PID)
numbers. (PIDs not available yet in InBiz. November 29, 2011.)
NoteFor detailed specifications about the SD flash memory module, refer to Router Hardware Description.
Accessing the SD Card
The SD card is accessed from the router exterior, though the router SD card port, shown in Figure 9-1.
CautionRemoving the SD card during normal router operation will cause the router to stop operating. Do not
remove the SD card while the router is operating.
NoteWhen the Cisco mounting bracket is attached the router, the bracket blocks access to the SD card port
slot the router exterior. To access the SD card slot without removing the router from the bracket or any
mounting installation that uses the bracket, refer to the instructions in Mounting the Router.
Before performing any of the tasks in this chapter, read the safety warnings in the Installation Safety and
Site Preparation chapter.
Preventing Electrostatic Discharge Damage
SD flash memory modules are sensitive to electrostatic discharge (ESD) damage, which can occur when
electronic cards or components are handled improperly, results in complete or intermittent failures.
To prevent ESD damage, follow these guidelines:
•Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.
•Connect the equipment end of the strap to an unfinished chassis surface.
•Place a removed the memory card on an antistatic surface or in a static shielding bag. If the card will
be returned to the factory, immediately place it in a static shielding bag.
•Avoid contact between the card and clothing. The wrist strap protects the card from ESD voltages
on the body only; ESD voltages on clothing can still cause damage.
•Do not remove the wrist strap until the installation is complete.
Chapter 9 Using the SD Flash Memory Module
Tools You Supply
You must provide a 13-mm box-end wrench or socket set to access the SD card.
Removing and Inserting the SD Card
To install or remove and SD card:
Step 1Use the wrench to loosen the seal that covers the SD card slot (Figure 9-2).
Step 2Confirm that the SD card LED (Figure 9-3) displays one of the following states:
•Green—Installed SD card is operating normally.
•Amber blinking—An unsupported card is installed in the router SD card slot.
•Amber flashing—No SD card is installed in the router SD card slot.
CautionDo not replace the SD card if the LED is blinking green. A blinking green state indicates that a data
transfer between the router and the SD card is in progress. Removing the card during a data transfer will
interrupt this process and could damage system data.
Step 3To remove an SD card from the router:
a. Press the SD card in slightly. The card moves outward so that it projects from the slot.
b. Pull the SD card out of the slot.
9-4
c. Place the SD card in an antistatic bag to protect it from static discharge.
a. Insert the SD card by sliding it into the SD card slot, with the connector first and the notched corner
facing up. The card is keyed so that you cannot insert it the wrong way.
b. Ensure that the card is seated in the slot connector and the edge of the card is flush with the edge of
the slot.
Step 5Replace and tighten the seal that you removed in Step 1, using the wrench you supply.
CautionYou must replace and tighten the seal that covers the SD card port when not using the port. If the card
port is not sealed, the router interior could be exposed to environmental elements, such as water, heat,
cold, and dust, that can permanently damage the router.
You can check the SD card status by viewing the SD Card LED.
SD Card LED
The SD card LED is located directly next to the SD card slot, and is visible when the SD card slot seal
is removed. This section describes the LED states and descriptions.
The Cisco 1240 Connected Grid Router supports up to three installed battery backup units, which
provide power to the router if the AC power fails. This chapter describes the Cisco
Battery Backup Unit features and how to install the battery backup unit in the router.
This chapter includes the following sections:
•Battery Backup Unit (BBU) Description, page 10-1
•BBU Components, page 10-5
•Battery Backup Unit LED, page 10-14
•BBU Technical Specifications, page 10-16
Battery Backup Unit (BBU) Description
The battery backup unit (BBU) provides the router with an emergency power source if the AC power
source is unavailable. The router supports up to three installed BBU units at one time. The total amount
of time that the installed BBUs can supply power to the router depends on how many BBUs are installed
in the router. The BBU can be installed in the router while the router is powered on and operating
normally.
The BBU is mounted on the router door interior (Figure 10-1). The BBU internal components include
battery cells, a primary protection circuit, a fuel gauge, and a charger. For detailed, illustrated
descriptions of the BBU, see
NOTE TO WRITER: Same illustration file as for Figure 4-4 (Opening Router Chassis)
Battery Backup Unit (BBU) Description
DEC. 2011—EFT REVIEW DRAFT—CISCO CONFIDENTIAL
Figure 10-1Battery Backup Units Mounted on Router Door
ItemCisco Product ID (PID) Description
1CGR-BATT-4AHBattery backup units. The router supports up to three BBUs, as
Enabling the BBU
The BBU is automatically enabled and begins supplying power to the router when the router detects that
power is not being received from the AC power supply. The BBU continues to supply power to the router
until at least one of the following conditions is met:
•The BBU is completely discharged
•AC power to the router is enabled
•The BBU battery cable is disconnected from the router
•The BBU is disabled with the system software (see BBU Technical Specifications, page 10-16)
NoteBBU Technical Specifications, page 10-16, contains technical details about the router power path
selection and the conditions that trigger the BBU to begin operating.
This section describes impact to the router configuration and operating capabilities when the router
switches from AC power to BBU power.
Event Messages
When the router detects that the power supply has changed from AC power to BBU power, the BBU is
enabled and the following syslog message is sent to the network management system:
Power mode changed to battery mode.
Router Configuration
The router software configuration is not impacted when the router switches from AC power to BBU
power.
Ethernet Switch and Connected Grid Module Operation
By default, the Ethernet switch module (module 2) and any Connected Grid modules installed in slots
3, 4, 5, and 6 continue to operate normally when the router switches from AC power to BBU power.
Battery Backup Unit (BBU) Description
You can configure the router to automatically power off specific modules when the router switches to
BBU power. See
number backup-battery command to configure the modules (including the Ethernet switch) that shut
down when the router switches to BBU power.
Router Interface Operation
To conserve power, the router will power off some interfaces when AC power is not available, and the
router is being powered by the BBU. When these interfaces are in power off mode, you cannot configure
them with the system software; however, you can display information about each interface using the
show commands for the interface. These include:
•show running config
•show hardware
•show interface
The following interfaces and router components switch to power off mode when the BBU is supplying
power to the router:
•Both SFP interfaces
•Both external USB ports
•Both serial (S232/485) ports
•IRIG-B port
Related Commands, page 10-15 for information on how to use the poweroff module
BBU Charging and Discharging
This section will discuss BBU charging/discharging cycles. Behavior is TBD. 5-October-11. Per
George Madden on Jan 9, check with software team.
NoteThe BBU provides power durations shown in Table 10-1 when the router is in a reduced power
Chapter 10 Installing Battery Backup Units
The router supports up to three BBUs at one time. You should install as many BBUs as needed, up to
three, to meet your emergency power requirements.
If all installed batteries fully discharge while providing backup power to the router, the router will send
a dying gasp message and then shut down.
consumption state, as described in Router Interface Operation, page 10-3. The durations in Table 10-1
are valid for 5 years.
Table 10-1Cisco Connected Grid Battery Backup Unit Model Number
Backup Power (Hours)Number of BBUs
41
82
123
Preparing to Install the BBU
Tools You Supply
You must provide a #1 Phillips screwdriver to install the BBU.
Safety Information for Installation
Safety Warnings
Before performing any of the tasks in this chapter, read the safety warnings in the Installation Safety and
Site Preparation chapter.
Warning
Warning
There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with
the same or equivalent type recommended by the manufacturer. Dispose of used batteries according
to the manufacturer's instructions.
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Statement 1015
Preventing Electrostatic Discharge Damage
The BBUs are sensitive to electrostatic discharge (ESD) damage which can occur when electronic cards
or components are handled improperly, and can result in complete or intermittent failures.
1Mounting bosses, for installing first BBU to router (6)
2BBU cable connector. The BBU is connected to the router cable harness with this
connecctor.
3Non-Cisco module power connector (12 V). If you install a non-Cisco module on the
router exterior, you can optionally use this connector to provide power to the module.
See the chapter
Installing Non-Cisco Modules for details.
4Ground lug (door to chassis)
5BBU cable harness. The cable harness connects the BBU(s) to the router and is the
physical connection over which BBU power is supplied to the router when AC power
is not available. The router is shipped with this cable even if the router is not shipped
with a BBU installed.
Follow these steps to install BBU 1 (the first BBU) in the router. If you are Installing BBU 2 or BBU 3,
you take different steps.
Step 1Open the chassis door by following the steps in the chapter Opening the Router Chassis.
Step 2Align the BBU so that the locating notch and the female battery-to-battery connector are facing out and
the connector is at the top of the router (
Step 3Align the six captive screws on the BBU to the mounting bosses on the router door (Figure 10-7).
Step 4Use your hand to loosely and evenly install the six captive screws into the mounting bosses, then use the
#1 Phillips screwdriver to tighten the screws using 10
Step 5Connect the BBU cable connector to the battery-to-router connector on the BBU. The connector is
shown in
Step 6Verify that the BBU has been successfully installed and is operating normally by viewing the status of
the
a. Red fast blinking—BBU is powered on and is initializing.
b. Red and green alternate blinking— BBU is synchronzing with the router.
c. The final BBU LED state is one of the following:
•Blinking amber—BBU detects that there is no AC power supplied to the router and begins
•Blinking green—The BBU was not fully charged when installed and is charging to full capacity.
•Solid green—The BBU is fully charged. The router is powered by the AC power supply.
Step 7Close the chassis door by following the steps in the chapter Opening the Router Chassis.
Figure 10-6.
Battery Backup Unit LED, page 10-14. The LED will display the following sequence:
discharging (supplying power to the router).
The router is powered by the AC power supply.
Installing a BBU in the Router
Installing BBU 2 or BBU 3
Follow these steps to install BBU 2 or BBU 3 (a second or third BBU) in the router. Installing BBU 1
requires a different set of steps.
Step 1Open the chassis door by following the steps in the chapter Opening the Router Chassis.
Step 2Align the BBU so that thelocating pin and the female battery-to-battery connector are facing out and the
locating notch is at the top of the router.
Step 3Slide the locating notch on the new BBU over the locating pin on the installed battery, and verify that
the BBU male connector on the new BBU is aligned with the female connector on the installed BBU.
Step 4Press firmly against the new BBU to seat the connectors and connect the new BBU to the installed BBU.
Step 5Use your hand to loosely and evenly tighten the six captive screws on the new BBUinto the
corresponding six threaded connectors on the installed BBU. Then use the #1 Phillips screwdriver to
tighten the screws to the installed BBU using 10
Step 6Verify that the BBU has been successfully installed and is operating normally by viewing the status of
the
Battery Backup Unit LED, page 10-14. The LED will display the following sequence:
a. Red fast blinking—BBU is powered on and is initializing.
b. Red and green alternate blinking— BBU is synchronzing with the router and the other BBUs.
c. The final BBU LED state is one of the following:
•Blinking amber—BBU detects that there is no AC power supplied to the router and begins
discharging (supplying power to the router).
to 12 inch-pounds of torque
OL-26223-01
•Blinking green—The BBU was not fully charged when installed and is charging to full capacity.
The router is powered by the AC power supply.
•Solid green—The BBU is fully charged. The router is powered by the AC power supply.
Step 7Close the chassis door by following the steps in Opening the Router Chassis.
The BBU features a single LED that indicates the status of the BBU when it is installed in the router.
Figure 10-8Battery Backup Unit LED Location
Chapter 10 Installing Battery Backup Units
10-14
LEDColor and StateDescription
BBU LED (no label) Green solidIdle state
Green blinkingCharging
Amber blinkingDischarging (providing power to the system)
Amber slow blinkingDisabled with the system software
Red/green blinkingInitializing
Red fast blinkingResetting
Red blinkingBootloader mode
Red slow blinkingTest mode
Red solidBBU failure
OffDisabled (disconnected from router or completely
This section describes system software command that support BBU operation, and includes the
following commands:
•backup-battery reset, page 10-15
•backup-battery inhibit discharge, page 10-15
•poweroff module number backup-battery, page 10-16
backup-battery reset
Use the backup-battery reset EXEC command to power the BBU off, then back on:
CGR1240# battery-backup reset
This command is functional only when AC power is supplying power to the router. If you enter this
command when the router is powered by the BBU, an error message is displayed.
This command resets all BBUs installed in the router.
Related Commands
backup-battery inhibit discharge
Use the backup-battery inhibit discharge EXEC command to disable the BBU automatic discharge
feature. Use this command when you must disconnect the router from AC power and want to prevent the
BBU from automatically discharging, for example when you must service the router or transport it
between locations.
This command is functional only when the BBU is supplying power to the router. If you enter this
command when the router is powered by AC power, an error message is displayed.
CautionEntering the backup-battery inhibit discharge command disables the BBU immediately. You are not
prompted to confirm the command. If you enter this command when the router is operating on the
network and powered by the BBU, the router will immediately power down and no longer operate on the
network.
backup-battery un-inhibit discharge
Take these step to reset the BBU to the default behavior (automatically begin discharging when the
router is not receiving AC power):
Step 1Connect the router to an AC power source.
Step 2Enter the backup-battery un-inhibit discharge EXEC command:
Use the poweroff module number backup-battery global configuration command to configure the
router to power off specific modules (including the Ethernet switch) when the router switches to BBU
power. By default, all modules continue to operate normally when the router is powered by the BBU.
Enter this command for each module that you want to automatically shut down.
SyntaxDescription
poweroff module number backup-battery Configures the router to power down the indicated
For example, to configure the router to shut down the Ethernet switch (all Ethernet ports) when the router
is powered by the BBU, enter this command:
CGR1240(config)# poweroff module 2 backup-battery
Chapter 10 Installing Battery Backup Units
module when the router switches to BBU power.
number—The number of module that is powered down:
•2: Ethernet switch module (all ports)
•3-6: Module inserted in the slot with corresponding
number. Slot numbering is described and illustrated
in the chapter
Router Hardware Description.
For example, to configure the router to shut down the module installed in Slot 6 when the router is
powered by the BBU, enter this command:
CGR1240(config)# poweroff module 6 backup-battery
Use the no form of the command to reset a module to the default behavior: continue to operate normally
when the router switches to BBU power. For example:
For detailed information on configuring the router, including configuration modes and saving
configurations, see the Cisco
1000 Series Connected Grid Routers software configuration guides.
BBU Technical Specifications
This section describes the specifications and standards supported by the BBU.
NoteFor BBU connector and cable specifications, see the appendix Connector and Cable Specifications.
Router Power Path Selection
During normal operation, the router is powered by the integrated AC power supply. The BBU is enabled
when the AC power is interrupted outside a range of 85V
BBU Charge/DischargeSupports charging or discharging only (not both simultaneously)
Total power providedAC power provides up to 60W of power to the router as follows:
Table 10-4Battery Backup Unit—Charge Specification s
Charge ConditionsDescription
Power drawNo more than 20 W when charging
State of chargeNo more than 90%
Entry to charging
Exit charging
Chapter 10 Installing Battery Backup Units
1
•BBU cable harness is installed
•Charge is enabled
•SoC <90%
•Ambient temperature is within 0 to 50C
•AC power detected in the range of 85V to 250V for more than 20 ms.
2
•BBU cable harness not installed
•Charge is disabled
•AC power (range of 85V to 250V) not detected for more than 20 ms.
•Ambient temperature is not within 0 to 50 C
1. All conditions are met.
2. Any condition is met
Operating and Storage Temperatures
Table 10-5Battery Backup Unit—Operating and Storage Temperatures
BBU StateTemperature Range
Battery charging0 to 50 C (32 to 122 F)
Battery discharging-20 to 60 C (-4 to 140 F)
Operating-40 to 85 C (-40 to 185 F)
Storage and shipping-40 to 70 C (-40 to 158 F)
The Cisco 1240 Connected Grid Router provides support for a compatible, non-Cisco wireless module,
installed on the router exterior and connected to the router integrated switch module. Wireless
connections send data from the router to field devices, such as smart meters, and from the router to the
utility or data management center.
This chapter contains the following sections:
•Non-Cisco Module Support, page 11-1
•Before Installing, page 11-2
•Install a Non-Cisco Module, page 11-3
•Related Information, page 11-9
Non-Cisco Module Support
CHAPTER
11
This section describes the support for, and requirements for, installing a non-Cisco module on the router.
CautionCisco does not provide technical support for issues related to non-Cisco products. You must contact the
module supplier or your reseller to obtain technical support for the non-Cisco module.
CautionInstalling a module that does not meet these requirements can negatively affect router performance.
Non-Cisco Module Requirements
Non-Cisco modules installed on the router exterior must meet the following requirements:
•Must comply with Type 4X and IP67 standards.
•External devices must have one of the following sets of dimensions:
–
7 x 4 x 2.5 inches (17.78 x 10.16 x 6.35 cm)
Reviewers: Provide the supported dimensions for the configuration shown in Figure 11-2.
A non-Cisco module can be installed or removed while the router is installed (usually on a pole top) and
operating normally.
Reviewers: Please confirm the above statement.
Certification
A non-Cisco module that is installed on the router does not interact with the router chassis. Connecting
a non-Cisco module to the router does not certify the module. Before installing the module, verify that
it is certified for use in your environment.
Power
The router interior features a 4-pin, Micro-Fit 3.0 connector, which provides 12 volts of power to a
connected module. See
Figure 11-5 for an illustration of the power connector.
Chapter 11 Installing Non-Cisco Modules
Before Installing
Read this section and the Installation Safety and Site Preparation chapter before following any
installation procedures in this chapter.
Prepare the Installation Site
The procedures in this chapter assume that you have prepared the installation site according to the
information in the
Read the Safety Information
Before performing any of the tasks in this chapter, you must read the safety warnings in this section and
in the
Installation Safety and Site Preparation chapter.
Preventing Electrostatic Discharge Damage
Many of the components discussed in this chapter are sensitive to electrostatic discharge (ESD) damage,
which can occur when electronic cards or components are handled improperly, results in complete or
intermittent failures.
To prevent ESD damage, follow these guidelines:
•Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.
Installation Safety and Site Preparation chapter.
11-2
•Connect the equipment end of the strap to an unfinished chassis surface.
•Place a removed the memory card on an antistatic surface or in a static shielding bag. If the card will
be returned to the factory, immediately place it in a static shielding bag.
•Avoid contact between the card and clothing. The wrist strap protects the card from ESD voltages
on the body only; ESD voltages on clothing can still cause damage.
•Do not remove the wrist strap until the installation is complete.
Cabling Guidelines
Follow these guidelines for using cables with the router:
•Position cables so that they do not place strain on the router connectors.
•Organize cables into bundles when necessary to avoid intertwining.
•Inspect cables to ensure adequate routing and bend radius.
•Install cable ties that comply with your site requirements.
Install a Non-Cisco Module
This section provides the information you need to connect a non-Cisco module to the router. Some steps
might require that you refer to the documentation that supports the module. This section includes these
installation topics:
•Tools and Materials You Supply, page 11-3
Install a Non-Cisco Module
•Open and Close the Router Door, page 11-3
•Connect the Module to the Chassis, page 11-4
•Cabling Instructions, page 11-6
•Connect to the Network, page 11-8
•Connect to Power, page 11-9
Tools and Materials You Supply
•Wrench—You must supply a 13-mm box-end wrench or socket set to remove liquid-tight seals from
the cable ports and to install the cable glands on the cable ports.
•Hardware—You must provide any hardware required to Connect the Module to the Chassis,
page 11-4.
•Power Connector Adapter—Depending on your module power cable, you might need to provide
an adapter to connect the module to the router 4-pin Micro-Fit 3.0 power connector.
Open and Close the Router Door
You might be required to open the router door to install the module. For instructions on opening and
closing the router door, see the chapter
In the configuration shown in Figure 11-2, install the module above the cable ports, and connect the
cables from the module through the cable ports on the router door.
With this configuration:
•Use the four mounting bosses indicated in Figure 11-2.
•Supported dimensions: (Need this information from hardware/mechanical engineering.)
•Cables are exposed externally
•Use cable glands to thread cables through the cable ports
•Follow the cabling instructions in External Cabling, page 11-7
When you install the module in the configuration shown in Figure 11-2, the cables are external to the
router, and then threaded through the cable ports on the router from the module.
Cisco Cable Glands
When you install the module in a configuration that uses external cabling from the module through the
cable ports on the router door, you must provide cable glands for each cable port.
Cable glands:
•Create seal to protect the router interior from environmental elements
•Can be ordered from Cisco: CGR-IP67GLAND (one cable gland per kit)
•Are described in detail in Cable Glands Description, page 6-12 in the Installing the Router chapter
CautionThe cable glands must be used for all cables that are threaded through the router chassis cable ports to
prevent exposing the router interior to environmental elements.
Install a Non-Cisco Module
Outdoor Cable Requirements
Verify that the cables you use to connect the module to the router meet the cable requirements described
in
Cable Requirements, page 6-13 of the Installing the Router chapter.
Connecting the Cable Glands
Step 1Use the 13-mm wrench to remove the liquid-tight seals from the cable ports on the router door.
Step 2Follow the steps in Cable Glands Installation Steps, page 6-13, in the Installing the Router chapter to:
•Thread the Ethernet and power cables through the cable glands
•Connect the cable glands to the cable ports on the router door
Internal Cabling
When you install the module in the configuration shown in Figure 11-3, the cables are threaded directly
through the cable ports on the router from the module, and are not exposed externally.
Cisco O-Ring
When you install the module in a configuration that uses internal cabling from the module, through the
cable ports on the router door, insert a rubber O-ring into each port to create an environmental-proof seal.
You can order an O-ring kit from Cisco using the model number xx-xxxxx. Each kit contains one O-ring.
Reviewers: Confirm that this is an orderable part from Cisco.
CautionThe O-ring must be used to prevent exposing the router interior to environmental elements.
Depending on your module power cable, you might need to provide an adapter to connect the module to
a 4-pin Micro-Fit 3.0 power connector.
Step 1Verify that the module power cable is threaded through the router cable port, and that the cable port has
cable glands or an O-ring installed.
Step 2Connect the power cable to the Micro-Fit 3.0 power connector. See in 2 in Figure 11-5 for connector
location.
Figure 11-5Cable Harness (1) and Power Connector (2)
Related Information
1
2
Related Information
This chapter describes installation procedures. For detailed, technical information about the router
hardware, including connector and cable descriptions, specifications, and pinouts, see the following
chapters:
•The Router Hardware Description chapter describes all features of the router hardware, including
the ports and cable glands described in this chapter.
•The Connector and Cable Specifications appendix includes the pinouts for the 12V power connector
View the Cisco 1240 Connected Grid Router LEDs to determine the overall state of the system and to
verify the status of specific connections, ports, and system components.
In addition to viewing the LEDs on the router hardware, you can use the router command line interface
as described in the section
remote locations.
This chapter includes the sections:
•LED Locations and State Descriptions, page 12-2
•Related Commands, page 12-8
Related Commands, page 12-8 to check the system status LED state from
View the system status LED to determine the overall operating and power status of the router.
A second, identical system status LED is located inside the router. See the section Alarm and Network
Connection LEDs, page 12-3 for the location of the interior SYS LED.
Figure 12-1System Status LED (SYS) — Router Bottom Exterior
Green Normal system operating status
Green blinkingThe system is starting up or power cycling, and loading system
software, including BIOS and operating system
Amber System receiving power but there is an error condition
OffSystem not receiving power
OL-26223-01
Page 69
Chapter 12 Router LED Locations and States
DEC. 2011—EFT REVIEW DRAFT—CISCO CONFIDENTIAL
Alarm and Network Connection LEDs
The router LEDs that indicate network activity and connection status, and the LEDs that indicate alarm
states, are located inside the router. To see these LEDs, you must open the router chassis according to
the instructions in the
Figure 12-2Network and Alarm LEDs — Router Front Interior
Opening the Router Chassis chapter.
LED Locations and State Descriptions
ALARM LEDs
OL-26223-01
Alarm LEDs
LED LabelColor and StateMeaning
ALM_IN1
ALM_IN2
ALM_OUT1
ALM_OUT2
OffNo alarm condition is present on the port
Red solidAlarm condition present on the port
The ETH 2/1 and ETH 2/2 interfaces are shared. Each interface (ETH 2/1 and ETH 2/2) supports either
a fiber optic GE connection (using an SFP module) or a copper GE connection, but not both. For more
information, see
Chapter 12 Router LED Locations and States
OffNo link established
Green, 2 blinks/pause10 MB/s link speed
Green, 1 blink/pause100 MB/s link speed
Combo Ports, page 2-26 in the chapter Router Hardware Description.
Combo Port LEDs–SFP Module and Gigabit Ethernet Ports
LED Label LED LabelColor and StateDescription
ETH 2/1
ETH 2/2
SFP_EN–This LED is active only for fiber optic (SFP module) connections on the ETH 2/1
and ETH 2/2 ports.
OffNo SFP installed in the port
Green solidSupported SFP installed in the SFP port
Green blinkingSFP module can be removed or replaced
Amber solidUnsupported SFP installed in the SFP port
SFP_SPD–This LED is active only for fiber optic (SFP module) connections on the ETH
2/1 and ETH 2/2 ports.
Green, 3 blink/pause100 MB/s link speed
Green, 2 blinks/pause 1000 MB/s link speed
OffNo SFP link established on the optical GE port
LNK/SPD–This LED is active only for copper GE connections on the ETH 2/1 and ETH
2/2 ports.
Amber, 3 blinks/pause 100 MB/s link speed
Amber, 2 blinks/pause 1000 MB/s link speed
Green solidEthernet cable connected and link established
OffNo link established
The router supports up to three battery backup units (BBUs). When two or more BBUs are installed, they
are connected to each other in a head-to-tail configuration in the router and the the BBU LED are in the
lcoations shown in
To see the LED for each BBU, open the router chassis according to the Opening the Router Chassis
chapter.
To see the SD card and the SD LED, you must remove the exterior plug that covers the router SD card
port, as shown here.
LED Locations and State Descriptions
Green blinkingCharging
Amber blinkingDischarging (providing power to the system)
Amber slow blinkingDisabled with the system software
Red/green blinkingInitializing
Red blinkingBootloader mode
Red slow blinkingTest mode
Red solidBBU failure
OffDisconnected from router or completely discharged
You can use router software command line interface (CLI) to view the status of System Status LED
described in the section
be installed at the top of an outdoor pole or other inaccessible location, and you might not be able to
view SYS LED on the router hardware. In this case, you can view the status of the LED from a remote
location using the router CLI.
This section includes these commands:
•show led, page 12-8
•show interface, page 12-8
show led
Use the show led command in any command mode to view the status of the router SYS LED.
One SYS LED is located on the router exterior, as shown in Figure 12-1 and the other is located inside
the router chassis, as shown in Figure 12-2.
The values displayed in the System LED field are described in the section System Status (SYS) LED,
page 12-2.
Related Commands
System Status (SYS) LED, page 12-2. During normal operation, the router can
This appendix includes specifications for the Cisco 1240 Connected Grid Router connectors, adapters,
and compatible cables, and is organized into the following sections:
•Connector Specifications, page A-1
•Cable and Adapter Specifications, page A-8
Connector Specifications
•GPS Serial Port, page A-1
•Alarm Ports, page A-2
•Console Port, page A-2
•Serial Port, page A-4
•AC Power Supply Connector, page A-4
•AC Power Supply Output Connector, page A-5
APPENDIX
A
•Battery Backup Unit Cable Connector, page A-5
•Non-Cisco Module Power Connector, page A-6
•Connected Grid Module Slots, page A-6
GPS Serial Port
For detailed information about the integrated GPS, see the chapter Router Hardware Description.
Table A-12SFP Port Cabling Specification (continued)
Cable and Adapter Specifications
SFP Module
Wavelength
(nm)
Cable
Type
Core size/
Cladding Size
(micron)
Modal
Bandwidth
(MHz/km)Cable Distance
1000BASE-BX-U1310SMF——32,808 ft (10,000 m)
1000BASE-BS-D1490SMF——32,808 ft (10,000 m)
1. A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF or 1000BASE-LX/LH SFP modules
and a short link distance can cause transceiver saturation and an elevated bit error rate (BER). When using the LX/LH SFP
module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module and
the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link
distances greater than 984 feet (300 m).
2. 1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF;
the distance depends on the fiber quality, the number of splices, and the connectors.
This appendix describes how to start a terminal session with the Cisco 1240 Connected Grid Router
using the console port. Start a terminal session with the router when you are at the router installation
location and want to administer the router with a direct connection using the command-line interface
(CLI) software.
Before You Begin
Before you start a terminal session with the router, you must connect a PC or PC terminal to the router
console port following the instructions in
Installing the Router.
About the Console Port
APPENDIX
Connecting the Console Port, page 6-15 in the chapter
B
CautionThe console port does not support cable glands. When a cable is connected to this port, the router interior
is exposed to environmental elements, which can damage the port and the router interior. This port
should be exposed only during terminal sessions, when a cable is connected to the port. This port should
never be left unattended when in use.
The console port is an asynchronous serial port that allows you to connect to the device for initial
configuration through a standard RS-232 port with an RJ-45 connector. Any device connected to this
port must be capable of asynchronous transmission.
Console Port Settings
Configure the following parameters for the console port:
ParameterConsole Port SettingDescription
Baud9600Specifies the transmission speed for the connection.
Data bits8Specifies the number of bits in an 8-bit byte that is used for data.
Connecting to the Console Port with Microsoft Windows
DEC. 2011—EFT REVIEW DRAFT—CISCO CONFIDENTIAL
ParameterConsole Port SettingDescription
ParityNoneSpecifies the odd or even parity for error detection.
Stop bits1Specifies the stop bits for an asynchronous line.
Using the Ctrl-C Command
The router console port is located on the router exterior and is accessible by removing the seal over the
console port. (For details, see
On many Cisco routers, you can enter Ctrl-C to interrupt the router startup process and then delete or
change the admin password, or view or delete the router configuration.
To prevent unauthorized access to the router configurations and passwords, the Ctrl-C command is
disabled on the Cisco
CGR 1240 Router while it is booting up and loading the system software.
Console Port, page 2-15 in the chapter Router Hardware Description.)
Connecting to the Console Port with Microsoft Windows
This section describes how to connect to the router console port using Microsoft Windows.
Step 1Start a terminal emulator application, such as Windows HyperTerminal (included with some versions of
Windows
Step 2Configure the terminal emulation software with the parameters described in About the Console Port,
page B-1.
Step 3Connect to the router.
OS) or PuTTY.
Connecting to the Console Port with Mac OS X
This procedure describes how to connect a Mac OS X system USB port to the console using the built-in
OS
X Terminal utility.
Step 1Use the Finder to go to Applications > Utilities > Terminal.
Step 2Connect the OS X USB port to the router.
Step 3Enter the following commands to find the OS X USB port number:
macbook:user$ cd /dev
macbook:user$ ls -ltr /dev/*usb*
crw-rw-rw- 1 root wheel 9, 66 Apr 1 16:46 tty.usbmodem1a21
DT-macbook:dev user$
B-2
Step 4Connect to the USB port with the following command followed by the router USB port speed:
To Disconnect the OS X USB Console from the Terminal Window
Enter Ctrl+A followed by Ctrl+\
Connecting to the Console Port with Linux
This procedure shows how to connect a Linux system USB port to the console using the built-in Linux
Terminal utility.
Step 1Open the Linux Terminal window.
Step 2Connect the Linux USB port to the router.
Step 3Enter the following commands to find the Linux USB port number:
root@usb-suse# cd /dev
root@usb-suse /dev# ls -ltr *ACM*
crw-r--r-- 1 root root 188, 0 Jan 14 18:02 ttyACM0
root@usb-suse /dev#
Connecting to the Console Port with Linux
Step 4Connect to the USB port with the following command followed by the router USB port speed:
root@usb-suse /dev# screen /dev/ttyACM0 9600
To Disconnect the Linux USB Console from the Terminal Window
output pinout A-5
asynchronous serial baud rates 3-7
auxiliary port
pinout A-2
B
baud rate
asynchronous serial 3-7
C
Ethernet cable types 3-5
I
installation
tools required 3-7
L
LAN
interface types 3-5
N
network connections 3-5
P
connections
asynchronous/synchronous serial 3-7
DCE 3-6
DTE 3-6
Ethernet 3-5
network 3-5
serial 3-5
console port
pinout A-2
D
DCE connections 3-6
DTE connections 3-6
E
ESD
damage prevention 3-2
ESD-preventive wrist strap 3-2
pinouts
AC power supply connector A-6
AC power supply output A-5
auxiliary port A-2
battery backup unit connector A-5
battery connector A-6
console port A-2
third party radio power connector A-6
S
serial connections, considerations 3-5
serial port specifications 3-6
site