CIS CL-OPT200T, CL-OPT200R Product Specification & Operation Manual

Page 1
CL-OPT200T/R Rev.900-759-30-00
©2013 CIS Corporation. All rights reserved.
English
CL-OPT200T/R
Product Specification
& Operation Manual
CIS Corporation
Page 2
CL-OPT200T/R Rev.900-759-30-00
©2013 CIS Corporation. All rights reserved.
2
Table of Contents
PAGE
1.
Scope of Application ........................................................................................................................................... 3
2. Handling Precautions .......................................................................................................................................... 3
3. Product Outline .................................................................................................................................................. 5
3.1. Product Configuration ................................................................................................................................. 5
3.2. Packaging .................................................................................................................................................. 5
4. Specifications ..................................................................................................................................................... 6
4.1. General Specifications ................................................................................................................................. 6
4.2. External Input/Output Signals ..................................................................................................................... 7
5. Function Settings ............................................................................................................................................... 8
6. External Connector Interface ............................................................................................................................... 9
6.1. 6pins circular connector HR10-7R-6PA (HIROSE) or equivalent (for both CL-OPT200T/R) .......................... 9
6.2. Camera Link Connector 12226-1100-00PL (SUMITOMO 3M) ......................................................................... 9
6.3. Optical Module Connector AFBR-57D9AMZ (AVAGO) (for both CL-OPT200T/R) ............................................ 10
7. LED Status Indication ....................................................................................................................................... 11
8. Selection of Power Feeding Method ................................................................................................................... 11
9. Precautions for Power Over Camera Link (PoCL) ................................................................................................ 12
10. Connection Example ......................................................................................................................................... 12
11. Dimensions ...................................................................................................................................................... 13
11.1. CL-OPT200T Dimensions ........................................................................................................................... 13
11.2. CT-OPT200R Dimensions ........................................................................................................................... 14
12. Cases for Indemnity (Limited Warranty) ............................................................................................................. 15
13. Product Service .............................................................................................................................. .................. 15
Page 3
CL-OPT200T/R Rev.900-759-30-00
1. Scope of Application
This is to describe CL-OPT200T/R signal converters enable CIS camera link cameras to connect with frame grabber boards via optical fiber cables. All specifications contained herein are subject to change without prior notice. Reproduction in whole or in part is prohibited.
2. Handling Precautions
The signal converters must not be used for any nuclear equipments or aerospace equipments with which mechanical failure or malfunction could result in serious bodily injury or loss of human life. Our warranty does not apply to damages or defects caused by irregular and/or abnormal use of the product. Please observe all warnings and cautions stated below.
Our warranty does not apply to damages or malfunctions caused by neglecting these precautions.
z CL-OPT200T can be used only with CIS camera link cameras. Output CLK of CL-OPT200R is 81MHz
fixed. To capture the images, please use a frame grabber board corresponds to 85MHz.
z Please use a metallic frame for heat dissipation. (The recommended size of the metallic frame:
larger than H:2mm W:90mm D:90mm)
CL-OPT200T/R Main Unit
CL-OPT200Fixing Bracket
z Do not use or store the converter in the following extreme conditions:
¾ Extremely dusty or humid places. ¾ Extremely hot or cold places (operating temperature –5 to +4 5)
z Do not apply excessive force or static electricity that could damage the converter.
z Follow the instructions in Chapter 6, “External connector interface” for connecting.
Improper connection may cause damages not only to the converter but also to the connected devices.
©2013 CIS Corporation. All rights reserved.
3
Page 4
CL-OPT200T/R Rev.900-759-30-00
z Confirm the mutual ground potential carefully and then connect the converter to monitors or computers. AC leaks from the connected devices may cause damages or destroy the converter.
z Do not apply excessive voltage. (Use only the specified voltage.) Unstable or improper power supply voltage may cause damages or malfunction of the converter.
z The voltage ripple of converter input power DC +12V±10% shall be within ±50mV.
z The rising time of converter input power supply voltage shall be less than +10V, Max 60ms.
Please avoid noises like chattering when rising.
In case of abnormal operation, contact the distributor from whom you purchased the product.
©2013 CIS Corporation. All rights reserved.
4
Page 5
CL-OPT200T/R Rev.900-759-30-00
©2013 CIS Corporation. All rights reserved.
5
3. Product Outline
CL-OPT200T and CL-OPT200R are signal converters enable CIS camera link cameras to connect with frame grabber boards via optical fiber cables. With optical fiber cables, data can be transmitted up to 150m length.
Please be noted that only CIS cameras can be connected to CL-OPT200T/R.
Key Features
□ With optical fiber cables, data can be transmitted up to 150m length. □ Owing to optical fiber cable connection, no radio interference or grand noise would occur. □ Comply with Camera Link Base/Medium Standard □ Only CIS camera link non-PoCL and PoCL cameras can be connected. □ As to PoCL, there are some limitations. (Please refer to page 10 for the details.)
3.1. Product Configuration
CL-OPT200T (Camera Link → Optical Signal Converter) CL-OPT200R (Optical Signal Camera Link Converter)
3.2. Packaging
Individual Carton Sub Carton (10 pieces/carton) Master Carton (100 pieces/carton)
Note: Master carton may change depends on the quantities to be shipped per delivery.
Page 6
CL-OPT200T/R Rev.900-759-30-00
©2013 CIS Corporation. All rights reserved.
6
4. Specifications
4.1. General Specifications
(1) Power Requirements DC+12V±10% (Max voltage not to exceed 15V.)
6pins circular connector or PoCL Input (with limitation).
(2) Power Consumption CL-OPT200T : Typ 4.3W / CL-OPT200R : Typ 3.8W (3) Dimensions
Refer to overall dimension drawing (H:25mm W:60mm D:90mm without protruding portion) (For both CL-OPT200T/R)
(4) Weight Approx. 200g (For both CL-OPT200T/R) (5) Camera Link
Input/Output Connector
CL-OPT200T/R (For both CL-OPT200T/R) mini Camera Link connector
12226-1100-00PL (SUMITOMO 3M)
CL-OPT200T
Camera Link non-PoCL or PoCL Input Camera Link input CLK frequency: Driver IC rated 20MHz 80MHz Base Configuration/Medium Configuration
CL-OPT200R
Camera Link Output Camera Link output CLK frequency: 81MHz fixed (Please connect with a frame grabber board corresponds to 85MHz.) Base Configuration/Medium Configuration
(6) Optical Connector
LC duplex connector Optical Module Rated: 8 Gb/s Light wavelength: 850nm Transmission Bandwidth: 6.125 Gb/s
AFBR-57D9AMZ(AVAGO)
(7) Optical Fiber Cable
Length
Max. 150m
(8) Supported Cameras CIS tested Camera Link, non-PoCL, and PoCL cameras.
Base Configuration Camera Series: VCC-G22/F22 (pixel clk: 49.09MHz) series VCC-G32/F32 (pixel clk: 72MHz) series VCC-G60 (pixel clk: 64MHz) series VCC-GC20/FC20 (pixel clk: 79.99MHz) series
Medium Configuration Camera Series: VCC-F51/F52 (pixel lk: 72MHz) series VCC-GC60/FC60 (pixel clk: 72MHz) series VCC-GC21/FC21 (pixel clk: 80MHz) series
Cannot run the camera at Full Configuration Mode. (Please contact our sales department regarding connections not listed above.)
(9) Trigger Delay Referenced Value (measured value with Fujikura
DXLC-2P-PC-(L)M-GC50/125-25R Optical cable) About 700ns (Circuit Fixed delay) + (5ns x L:Optical cable length (m))
(10) Video Delay Less than 1Line (Refer to the spec of camera to be connected.) (11) Serial Communications 9600bps fixed
Note: Set the frame grabber at 9600bps.
(12) Safety/Quality Standards UL: Conform to UL Standard including materials and others.
CE: Emission: EN55022:2010 (Class B)
Immunity: EN61000-6-2:2005
Page 7
CL-OPT200T/R Rev.900-759-30-00
RoHS: Conform to RoHS FCC: To be applied
(13) Durability Vibration
resistance
Acceleration : 98m/s2 (10G)
Frequency
: 20200 Hz Direction : X,Y, and Z, 3 directions Testing time : 120min for each direction Shock
resistance
No malfunction shall be occurred with 980m/s
2
(100G) for
±X, ±Y, and ±Z, 6 directions. (without package)
(14) Operation Environment Operation
Temeprature
-
5 +45With RH 20 80%
With no condensastion
(15) Storage Environment
-25 +60 with RH20 80% with no condensation
4.2. External Input/Output Signals
(1)GPIO FVAL output :No.3pin 6pins circular connector
(LVTTL output)
External T rigger input :No.4pin
IO Interface of 6 pins circular connector at rear
©2013 CIS Corporation. All rights reserved.
7
Page 8
CL-OPT200T/R Rev.900-759-30-00
5. Function Settings
With internal dip switch, trigger signals input can be selected.
(1) SW2-1
・・・
OFF : (Initial Setting)
(1) SW2-2
・・・
OFF : (Initial Setting)
(2) SW2-3 Trigger input
selection
・・・
ON : 6 pins circular connector input
OFF : Camera Link (CC1) input (Initial Setting) (3) SW3-1 Camera Link
Configuration
・・・
OFF : Base/Medium (Initial Setting)
ON : Do not use. (4) SW3-2
・・・
OFF : Not used (Initial Setting)
(5) SW3-3
・・・
ON : Not used
・・・
OFF : Not used (Initial Setting)
©2013 CIS Corporation. All rights reserved.
8
Page 9
CL-OPT200T/R Rev.900-759-30-00
6. External Connector Interface
6.1. 6pins circular connector HR10-7R-6PA (HIROSE) or equivalent (for both CL-OPT200T/R)
©2013 CIS Corporation. All rights reserved.
9
Pin No.
1 Power Input (DC+12V) 2 Power Input (DC+12V) 3 FVAL output 4 External Trigger Input 5 GND 6 GND
6.2. Camera Link Connector 12226-1100-00PL (SUMITOMO 3M)
CL-OPT200T CN1 (Camera Link In: Base side)
Pin No. Pin No.
1 NC/+12V(PoCL) 14 GND 2 X0- 15 X0+ 3 X1- 16 X1+ 4 X2- 17 X2+ 5 Xclk- 18 Xclk+ 6 X3- 19 X3+ 7 SerTC+ 20 SerTC­8 SerTFG- 21 SerTFG+ 9 CC1- 22 CC1+
10 CC2+ 23 CC2­11 CC3- 24 CC3+ 12 CC4+ 25 CC4­13 GND 26 NC/+12V(PoCL)
1
14
13
26
CN2 (Camera Link In: Medium Side)
Pin No. Pin No.
1 NC 14 GND 2 Y0- 15 Y0+ 3 Y1- 16 Y1+ 4 Y2- 17 Y2+ 5 Yclk- 18 Yclk+ 6 Y3- 19 Y3+ 7
100Ω
20 Terminated 8 Z0- 21 Z0+ 9 Z1- 22 Z1+
10 Z2- 23 Z2+ 11 Zclk- 24 Zclk+ 12 Z3- 25 Z3+ 13 GND 26 NC
Page 10
CL-OPT200T/R Rev.900-759-30-00
CL-OPT200R CN1 (Camera Link Out: Base side)
Pin No. Pin No.
1 GND/+12V(PoCL) 14 GND
25 X0- 12 X0+ 24 X1- 11 X1+ 23 X2- 10 X2+ 22 Xclk- 9 Xclk+ 21 X3- 8 X3+ 20 SerTC+ 7 SerTC­19 SerTFG- 6 SerTFG+ 18 CC1- 5 CC1+ 17 CC2+ CC2­16 CC3- CC3+ 15 CC4+ CC4­13 GND 26 GND/+12V(PoCL)
1
14
13
26
CN2 (Camera Link Out: Medium side)
Pin No. Pin No.
1 NC 14 GND
25 Y0- 12 Y0+ 24 Y1- 11 Y1+ 23 Y2- 10 Y2+ 22 Yclk- 9 Yclk+ 21 Y3- 8 Y3+ 20
100Ω
7 Terminated 19 Z0- 6 Z0 18 Z1- 5 Z1+ 17 Z2- 4 Z2+ 16 Zclk- 3 Zclk+ 15 Z3- 2 Z3+ 13 GND 26 NC
6.3. Optical Module Connector AFBR-57D9AMZ (AVAGO) (for both CL-OPT200T/R)
LC duplex Connector
©2013 CIS Corporation. All rights reserved.
10
Page 11
CL-OPT200T/R Rev.900-759-30-00
7. LED Status Indication
LED lights up when the camera, cable, fiber optic cable are linked normally. If it does not light up, please confirm the followings:
z Camera link cable, camera, and fiber optic cable are not connected. z No camera link CLK input z Data transmission failed via optical transmission z No power supplied to CL-OPT200T/R
8. Selection of Power Feeding Method
With internal dip switch, power feeding method can be changed.
(1) CL-OPT200T SW1
・・・
ON : Feed the power to the converter unit via 6 pins circular
connector. No power is feeded to the camera. (When non-PoCL camera is connected.)
(Initial Setting)
OFF : Feed the power to both of the converter unit and the
camera via 6pins ciruclar connector.
(When PoCL or PoCL-Lite camera is connected.) (2) CL-OPT200R SW1
・・・
ON : Feed the power to the converter unit via 6 pins circular
connector.
(Initial Setting)
OFF : Feed the power to the converter unit via the frame
grabber board.
(When PoCL frame grabber board is connected.)
©2013 CIS Corporation. All rights reserved.
11
Page 12
CL-OPT200T/R Rev.900-759-30-00
©2013 CIS Corporation. All rights reserved.
12
9. Precautions for Power Over Camera Link (PoCL)
CL -OPT200R (Receiving unit) can oper ate with power fed via the fr ame grabber board, but the f ollowing specification does not meet PoCL standard. When feeding the power via PoCL, please confirm with the power feeding specifications of the frame grabber board.
(1) The normal output timing of CLK output from the CL-OPT200R to the frame gr abber board shall be
maximum 10s after the last power input for the camera, the CL-OPT200T, or the CL-OPT200R.
(2) The intermittent CLK or LVAL/FVAL from the CL-OPT200R may be output to the frame grabber
board, while the camera, the CL-OPT200T, and CL-OPT200R are connected.
10. Connection Example
PoCL Feeder
connection
LC duplex Optical Cable : Within 150 meters
DXLC-2P-PC-50M-GC50/125-2SR
(フジクラ社製)
Camera Link
(Base Configuration)
Mini-CL Cable Within
meters
D26-3120-00C-300
3M社製)
Mini-CL Cable Within 3 meters
1MD26-3560-00C-300 (住友3M社製)
Camera Link
Frame Grabber Bord
CL-OPT200R
CL-OPT200T
3
1S
(住
Circuit
CL IN(M)CL IN(B)
OPT OUTDC IN
CL-OPT200T
CL OUT(M) CL OUT(B)
OPT IN DC IN
CL-OPT200R
Image Data
T
r
i
g
g
e
r
S
ig
n
a
l
Circuit
Trigger Signal
Power Supply
(SW2-3)
(SW2-3)
(SW1)
(SW1)
Page 13
CL-OPT200T/R Rev.900-759-30-00
11. Dimensions
11.1. CL-OPT200T Dimensions
©2013 CIS Corporation. All rights reserved.
13
Page 14
CL-OPT200T/R Rev.900-759-30-00
11.2. CT-OPT200R Dimensions
©2013 CIS Corporation. All rights reserved.
14
Page 15
CL-OPT200T/R Rev.900-759-30-00
©2013 CIS Corporation. All rights reserved.
15
12. Cases for Indemnity (Limited Warranty)
We shall be exempted from taking responsibility and held harmless for damage or losses incurred by the user in the following cases.
z In case damage or losses are caused by fire, earthquake, or other acts of God, acts by third party,
deliberate or accidental misuse by the user, or use under extreme operating conditions.
z In case indirect, additional, consequential damages (loss of business interests, suspension of
business activities) are incurred as result of malfunction or non-function of the equipment, we shall be exempted from responsibility for such damages.
z In case damage or losses are caused by failure to observe the information contained in the
instructions in this product specification & operation manual.
z In case damage or losses are caused by use contrary to the instructions in this product specification
& operation manual.
z In case damage or losses are caused by malfunction or other problems resulting from use of
equipment or software that is not specified.
z In case damage or losses are caused by repair or modification conducted by the customer or any
unauthorized third party (such as an unauthorized service representative).
z Expenses we bear on this product shall be limited to the individual price of the product.
13. Product Service
In case of abnormal operation, contact the distributor from whom you purchased the product.
Loading...