CIRUIT INTERRUPTION TECHNOLOGY A-0709 Service Manual

CIRCUIT INTERRUPTION TECHNOLOGY INC. A-0709
SPECIFICATIONS
Electrical Ratings 3.0 - 16A @ 125/250VAC
4.0 – 16A @ 125 (UL/CUL) Dielectric Strength 1500Vrms min Insulation Resistance Interrupt Capacity 125VAC, 1000A; 250VAC, 1000A Contact Endurance 125VAC X 150% of rated current - 500 cycles Calibration
Reset Manual reset
> 100M min
25°C – 105% of rated current - continuously carried 25°C – 106% to 134% - may trip or not 25°C – 135% of rated current - trip within 1 hour 150% of 4A – trip within 1 hour 25°C – 200% of rated current - trip within 1 minute
3A
B
C
Internal Resistance
3A – 5A
5.1A – 6A
6.1A – 7A
7.1A – 8A
8.1A – 9A
9.1A – 12A
12.1A – 14A
14.1A – 16A
1. Series
A-0709
2. Style P = 7/16” –28T bushing, Manual Reset
3. Current Rating: 3A – 16A
4. Reset Button Color: B = Black (White Printing) W = White (Black Printing)
5. Hardware:
C = 1 Hex Nut, 1 Name Plate D = 1 Knurled Nut, 1 Name Plate E = 1 Hex Nut, 1 Knurled Nut, 1 Name Plate F = 2 Knurled Nuts, 1 Name Plate G = 2 Hex Nuts, 1 Name Plate
A-0709
DIMENSIONS
PANEL CUT OUT
P
E198027
0.120
0.100
0.075
0.035
0.020
0.015
0.010
0.008
TEMP 3.0A-4.0A 4A-16A
60°C 55°C 50°C 45°C 40°C 35°C 30°C
25°C
20°C 15°C 10°C
Derating Factor
--- X 0.50
--- X 0.60
--- X 0.70 X 0.45 X 0.75 X 0.55 X 0.80 X 0.70 X 0.86 X 0.80 X 0.92
X 1.00 X 1.00
X 1.10 X 1.06 X 1.20 X 1.09 X 1.35 X 1.20
CITFUSE Website: www.citfuse.com Tel: 763-535-2339 Fax: 763-535-2194