Step 1: Create a test from a sample cable
as in the previous section.
2. Press Print.
If you have a printer connected: If you don’t have a printer connected:
Documenting a Cable
Step 2:
1. Press
Verify Test.
The document
is printed.
1. Press down
to view the print
option.
1100R+ Cable Documentation
Cable Signature: 39E92F−4Z020
Cable Description: Merrit Dialisis Power
Adapter Signature(s):
J1
03FAC1 J9 J17 J25
J2
B53FD7 J10 J18 J26
J3 J11 J19 J27
Step 1: Make sure the test program you want to use is loaded.
Creating a test from a cable.
1100R+ Cable Documentation
Cable Signature: 39E92F-42020
J1 Adapter Signature: F5B4E0
J2 Adapter Signature: 03FAC1
Connection Resistance: <Auto .5
Insulation Resistance: >50M
retrieving a test from memory.
OR
1100R+ Cable Report
Cable Signature: 39E92F-4Z020
J1 Adapter Signature: F5B4E0
J2 Adapter Signature: 03FAC1
Connection Resistance Threshold <= Auto .5
Insulation Resistance Threshold > 500K ohm
Testing a Cable
The loaded test is always displayed
on the main menu.
You can load a new test program by:
Step 2: Duplicate the adapter setup you had in the original test.
Refer to the documentation
you created for the test.
OR
1. Press Test for the loaded
test.
2. Press Show Required List.
3. After installing the correct
adapters, press RETRY to
check the setup.
To remember the correct adapter
positions in the tester:
Original adapter
positions
2. Scroll down , recording the information on a
1100R+ Cable Documentation Form.
creating a test from a cable
CABLE LEARNED
Verify Test
Save Learned Test
TEST: 39E92F-4Z020
CABLE LEARNED
Verify Test
Save Learned Test
TEST: 39E92F-4Z020
CABLE LEARNED
Verify Test
Save Learned Test
TEST: 39E92F-4Z020
SIGNATURE 1100H+
Set User Preferences
Set Up Test Program
TEST: 39E92F-4Z020
CABLE LEARNED
Verify Test
Save Learned Test
TEST: 39E92F-4Z020
TEST RETRIEVED
Print Test
Edit Retrieved Test
TEST: 39E92F-4Z020
INSTALL CORRECT
ADAPTERS TO TEST
Show Required List
RETRY
Step 1: From
the main menu
Scroll down .
Step 2: Press Do
File Management.
Whereas the cable’s connectors
and the wire pattern determine the
first part of the signature.
Interpreting Error Messages
Deleting a Test from Memory
SIGNATURE 1100R+
Set User Preferences
Set Up Test Program
TEST: 7EO1F7– 2J8NH
To See a Detailed Error Messages:
Step 3: Press
Delete a Test.
Step 4: Scroll
down to the
memory location.
Then press the
button for the
test to delete.
Low Voltage Errors
In this example we view
the first detailed error and
see NET 1 has a SHORT.
Press View Errors
OR
Press Print Errors
SHORT
The tester senses an interconnection that should not exist in the cable.
OPEN
The tester does not sense an interconnection that should exist in the cable.
MISWIRE
The tester senses that a contact that should have a valid connection is
instead connected to a wrong contact.
HIGH
RESISTANCE
The tester senses a cable interconnection that has too much resistance.
Intermittent Errors
To be an Intermittent error the cable must be good, then go bad, then go
good again. Intermittent errors may be shorts, opens, miswires, and high
resistance — just like the Low Voltage errors above.
GOOD
BAD
GOOD
To see other
detailed errors,
we can scroll
down .
If Fault Location is ON, asterisks show
the short is closest to these two pins.
DO FILE MANAGEMENT
Print Mem Loc List
Save Current Test
Delete a Test
TEST TO DELETE
4: A39CB4-2J8NH
5: 8E10C4-2J8NH
6: B34892-6F8N0
SIGNATURE 1100R+
Do File Management
Version Information
PRINT: 7EO1F7– 2J8NH
FAILED LOW VOLTAGE
View Errors
Print Errors
Remove=> New Test
ERROR:BBF085-2X8NH
NET 1: SHORT
J1-001 *J3-001 TO
J1-002 *J3-002