01
1 — So, hello!
2 — Features
3 — How to use it?
4 — How to configure it?
5 — 3G Communications
6 — Integrations
7 — OCPP 1.5
8 — Monitoring
9 — Technical Data
10 — Need help?
Here’s your
guide to use and
configure eVolve.
02
04
06
08
20
24
26
34
38
40

02
Wallbox eVolve Series Instruction Manual
This manual provides information about the usability and configuration of
the Wallbox eVolve Smart, which has been designed and tested to allow
electric vehicle charging, specified in IEC 61851.
It contains all the necessary information for safe use and help to get the
best performance from it with step-by-step configuration instructions.
ATTENTION!
Indicates that the damage to property can occur if appropiate
precautions are not taken.
1
THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT
SAFETY INFORMATION IN THIS DOCUMENT
• Complies with IEC 61851, Electric vehicle conductive charging
system (IES 61851-1 and IEC 61851-22)
• Complies with IEC 62196, Plugs, socket-outlets, vehicle
couplers and vehicle inlets (IEC 62196-1 and IEC 62196-2).
• Standards: 2014/35/UE, LVD;2014/30/UE, EMC.
• RFID complies with ISO 14443A/B

03
So, hello!
The Charge Point may not include elements of electrical protection.
• Read all the instructions before
using and configurating this
product.
• Do not use this unit for anything
other than electric vehicle
charging.
• Do not modify this unit. If
modified, CIRCONTROL will
reject all responsibility and the
warranty will be void.
• Comply strictly with electrical
safety regulations according to
your country.
• Do not make repairs or
manipulations with the unit
energised.
• Only trained and qualified
personnel should have access to
electrical parts inside the device.
• Check the installation annually by
a qualified technician.
• Remove from service any item
that has a fault that could be
dangerous for users (broken
plugs, caps that don’t close...).
• Use only Circontrol supplied
spare parts.
• Do not use this product if the
enclosure or the EV connector is
broken, cracked, open, or shows
any other indication of damage.
IMPORTANT SAFETY INFORMATION
Read carefully all the instructions before manipulating
the unit.

04
Wallbox eVolve Series Instruction Manual
2
4
1
1 - Display
3 - Plug A LED Beacon
2 - Proximity Card Reader
4 - Plug B LED Beacon
A
B
CIRCONTROL
3
2

05
Features
Charge Point may not include elements of electrical protection.
• Display: Information about the
status of the connectors and
detailed data as kWh and duration
time.
• Connector Lock: Type 2
connector has a lock system
to avoid disconnection of EV
meanwhile is charging.
• Light beacon: Three colour
led indicates the status of the
connectors.
• RFID: User authentication.
• Ethernet: TCP/IP communication
for remote supervision and
configuration.
• 3G Modem (optional): For
those places where wired
communications are not
sufficient.
• Energy metering: Integrated
meter built is measuring power
and energy consumed by the EV
during a charge transaction.
• Remote access: For supervision
and control from everywhere.
• Charge transaction historics:
Charge Point is capable of storing
information about the charge
transactions.
• OCPP: Open standard
communication protocol, allows
communication between the
Charge Point and the Central
System.
MAIN FEATURES OF THE UNIT

06
Wallbox eVolve Series Instruction Manual
3
B
Start Charging
1. The first step is to show the proximity card to the reader*
Once done, the Led Beacon turns Blue and the Display shows the following
sequence of messages:
2. Plug the cable to the vehicle, choose one available socket (in case there
are more than one) and plug the cable to the Charge Point.
Once done, the Display shows the following sequence of messages:
*If the proximity card reader is disabled, charge transaction starts
automatically when a vehicle is detected.

07
How to use it?
C
Stop Charging
1. The first step is to show the proximity card to the reader*
Once done, the Led Beacon turns Green and the Display shows the
summary of the charge transaction:
2. Unplug the cable from both sides.
Once done, the connector becomes available and the Display shows the
following sequence of messages:
*If the proximity card reader is disabled, charge transaction stops
automatically when a cable is disconnected from the vehicle.

08
Wallbox eVolve Series Instruction Manual
4
A
Introduction
The Charge Point can be configured and monitorized to establish
preferences or specific setup using integrated Ethernet communication
port allocated in the main controller device.
B
What’s needed
Before proceeding with the configuration, make sure all the following is
ready:
Computer running Microsoft Windows,
at least Windows XP .
UTP Cable (Crossover recommended)
IPSetup.exe (Software provided by
Circontrol)

09
How to configure it?
Charge Point is delivered with default network setting of “DHCP enabled”.
It means that the charge station will try to obtain an IP address from a
DHCP server available on the network.
Connecting a PC directly with the Charge Point needs to be done with
static IP address. The PC and the Charge Point must be in the same
network and in the same range.
C
Connection
In order to change the IP of the Charge Point, use “IP Setup”.
• Enter the MAC of the device
• Enter the desired IP Address
• Click on “Configure”

10
Wallbox eVolve Series Instruction Manual
D
Setup web page
Setup web page allows managing networking setup, modem 3G setup,
upgrading the device and other options.
To access the setup web page, open a web
browser and enter the following address:
http://”IP ADDRESS”/html/setup.html

11
E
Network setup
Value Description
Host name Name of the device on the network
DHCP Enable or disable the IP address assignment
by a DHCP server
DHCP Client ID Client ID associated to the DHCP Server (If
available)
Address IP address assigned to the charge point
Netmask Netmask of the network
This section provides basic configuration of the network parameters.

12
Wallbox eVolve Series Instruction Manual
F
Modem setup (only 3G models)
Value Description
APN Access point name
Consult SIM Card network operator
User Credentials assigned to the APN
*If credentials are not needed, insert “1234”
on both fields
Password
Reset timer (hours) Timer to reset the modem and
communications
Ping IP IP address where the Charge Point pings
Ping period (minutes) Period between pings
Reset on ping failure • Checked: enabled
• Unchecked: disabled
For enabling 3G integrated modem check this section, to set the
parameters provided by the SIM Card network operator.

13
G
Public address manager
Value Description
Address type • Local address: select this option if the
OCPP central system is connected to the
same private network than the charge
point is already connected.
• Static address: select this option if the
external modem/router has static public
IP address.
Note: Public IP address or domain name must
be entered manually in the “Public IP” text
box.
• SIERRA Wireless Raven XE H2295EW:
Select this option only when SIERRA
Wireless RAVEN XE cellular router is
connected to the charge point.
• SIERRA Wireless AirLink LS300: Select
this option only when SIERRA Wireless
AirLink LS300 cellular router is connected
to the charge point.
• Embedded modem: Select this option
when using 3G integrated modem.
This section is for integrations and allows setting the IP address to
establish connection between the Charge Point and the Central System.

14
Wallbox eVolve Series Instruction Manual
H
Locale setup
Value Description
Language Selecting desired language to show
This section allows changing the language of the Display.
I
Time setup
Value Description
Primary NTP Server Synchronize the time through internet auto-
matically
Secondary NTP Server
Time zone Select the regional unit time according to the
location
Time Current date and time of the unit
This section allows setting the time and region unit time.

15
J
Dynamic DNS setup
Value Description
Server type Select the type of Dynamic DNS Server
Hostname Parameters provided by dynamic DNS server
User
Password
Server
Port
Dynamic DNS is a system that updates in real-time the public IP address
assigned to a domain name server.

16
Wallbox eVolve Series Instruction Manual
K
Security setup
Value Description
Password • ON: authentication enabled
• OFF: authentication disabled
Username Username and password authentication for
setup.html web page
New password
Repeat password
Prevent unauthorised access to the setup web page.
All of the parameters are disabled by default factory settings.
Do not forget the credentials. There is no way to reset the device
to default factory settings.
It will require returning the unit to the service centre.

17
L
System information
Value Description
MAC Identifier of the network card of the unit
Version Upgrade Version of the firmware currently installed
and link to the upgrade web page
Powerstudio version Engine version of PowerStudio
Devices status Link that allows viewing the status of the
configured devices
This section provides basic information about the unit.

18
Wallbox eVolve Series Instruction Manual
M
System upgrade
Upgrade web page allows to upgrade the firmware of the Charge Point
remotely.
This file is provided by the service centre.
Firmware file transfer must not be interrupted. Failure of the file transfer
involves irreversible damage the main controller of the Charge Point.
It will require returning the unit to the service centre.
Ensure that the unit is not affected or powered off while updating.
Direct link: http://”IP ADDRESS”/html/upgrade.html

19
N
Logs
Log web page is a log that is created since charge point is powered ON.
If charge point is restarted this log is erased and immediately is created
a new one.
Direct link: http://”IP ADDRESS”/services/chargePointsInterface/log.html

20
Wallbox eVolve Series Instruction Manual
5
Access “Modem setup” section of the “Setup web page” (refer to Section
4 for more information).
Once SIM card is inserted on the embedded 3G modem, enter the following
parameters:
- APN (Access Point Name)
- User
- Password
*These parameters are provided by the network operator of the SIM card
inserted.
A
Parameters

21
3G Communications
B
SIM PIN
Go to following address: http://”IP ADDRESS”/html/modem-status.html
The first time that SIM card is inserted, the Charge Point asks to enter its
PIN number.
*PIN number will not be required anymore after entering for the first time
and the device will start 3G communications automatically.
After entering PIN number and clicking on Confirm button, it shows the
following confirmation message:

22
Wallbox eVolve Series Instruction Manual
C
Connection Status
When the 3G connection is successful, following message appears on the
web page of modem status.
Direct link: http://”IP ADDRESS”/html/modem-status.html
Value Description
Connection • 3G communications status
• Data access protocol used
• Signal and coverage
IP Address Public IP assigned by the SIM card network
operator
Good signal Bad signalModerate signal
-80 dBm -90 dBm-50 dBm -100 dBm
Following diagram shows an approximated range of signal strength that can be
obtained depending on the location of the Charge Point:

24
Wallbox eVolve Series Instruction Manual
Following items must be taken into account before proceeding in order to
ensure proper performance:
• If 3G modem is enabled, select Embedded Modem within Public
Address Manager section:
Direct link: http://”IP ADDRESS”/html/setup.html
• Select desired integration version according to your charge point
operator:
Direct link: http://”IP ADDRESS”:65432
6
Before starting
A

25
Integrations
Setting up
B
Once the desired integration is activated on the charge point, it starts as
configuration mode and all fields are empty. The data is always saved
even when the Charge Point is powered off.
In order to setting up the integration open a web browser and enter the
following link:
http://”IP ADDRESS”:8080
Use following credentials to access:
User admin
Password 1234

26
Wallbox eVolve Series Instruction Manual
7
Management system (CS)
A
Allows the Charge Point to know where the central system is hosted to
notify all the requests.
Following fields are mandatory to complete:
Value Description
Host URL URL address of the central system
User Authentication for central system.
*Leave in blank if not neededPassword

27
OCPP 1.5
Charge Box (CB)
B
Please contact to the Central System to get the configuration parameters.
Value Description
Charge Box Id. Charge point identifier
Protocol
Require CS client
certificate
If HTTPS is selected, make sure to have CS
Server CA certificate
*Provided by the Central System
OCPP Listening port Incoming listening port for remote request
User (for the CB
server)
Authentication for central system
*Leave in blank if not needed
Public IP timeout Maximum waiting time to obtain the public IP
address of the 3G modem

28
Wallbox eVolve Series Instruction Manual
C
OCPP Settings
Select proper values according to OCPP Central System parameters.
Value Description
Use local white-list • Yes: local list of authorized users
enabled
• No: local list of authorized users
disabled
Authorization check
order
• White-list first: ID authorization has first
place on the local white-list. If the user
does not exist locally, then in second
place backend is asked to obtain the
authorization.
• CS first: ID authorization is always asked
to the backend.

29
Value Description
Authorize always in
offline mode
• Yes: If user is not present locally in the
local white-list and charge point cannot
ask to the backend, user is allowed to
start a new charge transaction.
• No: If user is not present locally in the
local white-list and charge point cannot
ask to the backend, the user is not allowed
to start a new charge transaction.
Retry after CS internal
error
• Yes: Enabled. If StatusNotification,
StartNotification or StopNotification are
not delivered correctly to the backend,
Charge Point tries again to send those
requests until it is successful.
• No: Disabled.
NOTE: Special development must be done in
backend in order to retry the messages by
charge point
Use OCPP time
synchronization
• Yes: Synchronization of date and time
enabled
• No: Synchronization of date and time
disabled
Compress OCPP
messages
• Yes: Enabled
• No: Disabled

30
Wallbox eVolve Series Instruction Manual
Value Description
Energy for Start/Stop
transaction
• Partial: Consumed value of energy by the
vehicle sent between start and stop
• Total: Existing value of the total
accumulated energy of the meter, is sent
between start and stop
Energy for
MeterValues
• Partial: Sends partial energy consumption
while vehicle is charging
• Total: Sends the existing value of the
total accumulated energy of the meter
Stop charge if
StartTransaction
rejects the user
• Yes: Stop existing charge transaction
after response from backend
(StartTransaction.conf) when user is
Blocked, Expired or Invalid.
• No: Charge transaction does not stop
even if backend rejects the user.
(StartTransaction.conf)
*Set this option according to your backend
system.
Stop charge if
StartTransaction
replies ConcurrentTx
• Yes: Stop existing charge transaction
after response from backend
(StartTransaction.conf) when user has
already involved in another transaction.
• No: Charge transaction does not stop
even if backend rejects the user.
(StartTransaction.conf)
*Set this option according to your backend
system.

31
Value Description
Require auth. At
remote Start
• Yes: Charge Point sends an authorization
request before starting a new remote
charge transaction request.
• No: Charge Point starts a new remote
charge transaction without authorization
request.
Active Power in
MeterValues
• Yes: Send power (Power.Active.Import)
and energy (Energy.Active.Import.
Register) consumed by the vehicle within
meter values requests.
• No: Only energy consumed is sent within
meter values request.
Heartbeat interval Interval between Heartbeats (in seconds) for
the Central System
Connection timeout Timeout (in seconds) before connecting to the
Central System
Meter value sample
interval
Interval between Meter values (in seconds)
during charge transaction.
NOTE: Meter values are disabled if 0 seconds
is set.

32
Wallbox eVolve Series Instruction Manual
D
Finalizing
Final actions to complete the OCCP configuration.
Value Description
Save Setup Save settings and apply changes.
Refresh Restore data entered.
Configuration: Upload
from file
Export configuration into a single file
Configuration: View file Import configuration from a file

34
Wallbox eVolve Series Instruction Manual
8

35
Monitoring
Client
A
Charge Point status can be monitored using a software provided by
Circontrol:

36
Wallbox eVolve Series Instruction Manual
B
Plug section
This section describes the plug status and other useful information.

38
Wallbox eVolve Series Instruction Manual
9
MECHANICAL DATA
Enclosure rating
IP54 / IK10
Enclosure material
Aluminium & ABS
Enclosure door
Frontal key locked door
Net weight
Small: 25 kg
Large: 30 kg
Dimensions (D x W x H)
Small: 450 x 290 x 600 mm
Large: 450 x 290 x 850 mm
ENVIRONMENTAL CONDITIONS
Operating temperature
-5ºC to +45ºC
Operating temperature with
Low Temperature Kit*
-30ºC to +45ºC
Storage temperature
-20ºC to +60ºC
Operating humidity
5% to 95% Non-condensing
GENERAL DATA
Display
LCD Multi-language
Light beacon
RGB Colour indicator
RFID reader
ISO / IEC 14443A/B
MIFARE Classic/Desfire EV1
ISO 18092 / ECMA-340
NFC 13.56MHz
Meter
MID Class 1 - EN50470-3

39
Technical Data
MODEL** CONNECTORS OUTPUT
CURRENT
OUTPUT
POWER
S
Type 2 Socket
Type 2 Socket
32A
32A
7,4kW
7,4kW
T
Type 2 Socket
Type 2 Socket
32A
32A
22kW
22kW
TM4
Type 2 Socket / CEE 7/3
Type 2 Socket / CEE 7/3
32A / 16A
32A / 16A
22kW / 3,6kW
22kW / 3,6kW
(*) Depending on the model, some components may vary
(**) For availability of models, please consult your local supplier
ELECTRICAL DATA
Power supply
1P+N+PE / 3P+N+PE
Input voltage
230VAC+/- 10% / 400VAC+/-10%
Frequency
50Hz / 60Hz
Overcurrent protection*
MCB (curve C)
Safety protection*
RCD Type A (30mA) / Type B
Surge protection*
Transient surge protector
IEC 61643-1 (Class II)
CONNECTIVITY
Ethernet
10/100BaseTX (TCP-IP)
Cellular*
Modem 3G / GPRS / GSM
Interface protocol
OCPP

40
Wallbox eVolve Series Instruction Manual
10

41
Need help?
In case of any query or need further information, please
contact our Post-Sales Department
(+34) 937 362 940 (+34) 937 362 941
ps-support@circontrol.com circontrol.com

Wallbox eVolve Series Instruction Manual
CIRCONTROL WALLBOX
EVOLVE SERIES
INSTRUCTION MANUAL
A comprehensive guide on
how to use and configure
your Wallbox eVolve.
V1.0, April edition 2018
CIRCONTROL S.A. - ALL RIGHTS RESERVED
R72