Circontrol CCL-WB2M-SMART series, CCL-WB2M-SMART TRI series, CCL-WB MIX-SMART series, CCL-WB MIX-SMART TRI series Instruction Manual

INSTRUCTION MANUAL
(*)
3G models also included
CCL-WB2M-SMART* CCL-WB2M-SMART TRI* CCL-WB MIX-SMART* CCL-WB MIX-SMART TRI*
WALLBOX SMART Instruction manual
This document is copyrighted, 2013 by Circontrol, S.A. All rights are reserved. Circontrol, S.A. reserves the right to make improvements to the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of the original manufacturer. Information provided in this manual is intended to be accurate and reliable. However, the original manufacturer assumes no responsibility for its use, or for any infringements upon the rights of third parties that may result from its use. All other product names or trademarks are properties of their respective owners.
V1.0, April edition 2013
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 1
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
CONTENTS
1 INTRODUCTION ................................................................................................................... 3
1.1 IMPORTANT SAFETY INFORMATION ........................................................................ 3
1.2 DESCRIPTION .............................................................................................................. 3
2 FEATURES ........................................................................................................................... 4
3 INSTRUCTIONS FOR USE .................................................................................................. 5
3.1 START RECHARGING PROCEDURE.......................................................................... 5
3.1.1 DISPLAY INFORMATION WHILE CHARGING .................................................... 7
3.2 STOP RECHARGING PROCEDURE ............................................................................ 8
3.2.1 DISPLAY INFORMATION WHEN RECHARGING ENDS .................................. 10
4 ETHERNET COMMUNICATIONS ...................................................................................... 11
4.1 PREREQUISITES ....................................................................................................... 11
4.2 NETWORK TOPOLOGY ............................................................................................. 12
4.3 STEP BY STEP LAN CONNECTION PROCEDURE .................................................. 13
4.4 SETUP WEB PAGE ..................................................................................................... 17
4.4.1 NETWORK SETUP ............................................................................................. 18
4.4.2 MODEM SETUP (only for 3G series) .................................................................. 18
4.4.3 PUBLIC ADDRESS MANAGER .......................................................................... 19
4.4.4 LOCALE SETUP ................................................................................................. 20
4.4.5 TIME SETUP ....................................................................................................... 20
4.4.6 DYNAMIC DNS SETUP ...................................................................................... 21
4.4.7 SECURITY SETUP ............................................................................................. 22
4.4.8 SYSTEM INFORMATION.................................................................................... 23
4.5 OTHER URL CONFIGURATION ................................................................................. 25
4.5.1 LOG WEB PAGE ................................................................................................. 25
4.5.2 MODEM STATUS (FOR 3G MODELS) .............................................................. 26
5 3G COMMUNICATIONS (FOR 3G MODELS) ................................................................... 27
5.1 STEP BY STEP CONFIGURATION ............................................................................ 27
6 CHARGE POINT OCPP INTEGRATION ............................................................................ 30
6.1 INTEGRATION SETUP WEB PAGE ........................................................................... 30
6.2 OCPP ENGINE SETUP WEB PAGE ........................................................................... 31
6.2.1 APPLICATION PARAMETERS ........................................................................... 32
6.2.2 POWERSTUDIO ENGINE................................................................................... 33
6.2.3 CHARGE BOX (CB) ............................................................................................ 34
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 2
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.2.4 OCPP SETTINGS ............................................................................................... 35
6.2.5 MANAGEMENT SYSTEM (CS) .......................................................................... 36
6.2.6 SSL CERTIFICATES ........................................................................................... 37
6.2.7 ACTIONS ............................................................................................................. 37
6.3 STEP BY STEP INTEGRATIONS PROCEDURE ....................................................... 38
7 URL SUMMARY TABLE .................................................................................................... 41
8 CHARGE STATION MONITORING .................................................................................... 42
8.1 USING CIRCARLIFE CLIENT ..................................................................................... 42
8.2 USING WEB BROWSER ............................................................................................. 43
9 CIRCARLIFE SCADA CLIENT ........................................................................................... 44
9.1 MENU BAR .................................................................................................................. 45
9.1.1 OPTIONS MENU ................................................................................................. 45
9.1.2 VIEWS MENU ..................................................................................................... 46
9.1.3 GENERAL MENU ................................................................................................ 47
9.2 TOOLBAR ................................................................................................................... 48
9.2.1 TOOLBAR SETUP MENU ................................................................................... 48
9.3 STATUS BAR .............................................................................................................. 49
9.4 SCADA GRAPHS ........................................................................................................ 50
9.4.1 GRAPHS TOOLBAR ........................................................................................... 52
9.5 SCADA TABLES .......................................................................................................... 53
9.5.1 TABLE PROPERTIES ......................................................................................... 54
9.6 NOTIFIED EVENTS..................................................................................................... 55
10 CCL1 ENGINE .................................................................................................................... 56
10.1 BOLLARD STATE SECTION ...................................................................................... 57
10.2 PLUGS SECTION ........................................................................................................ 58
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 3
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
1 INTRODUCTION
This manual contains all the information necessary for safe use of the electrical vehicle charger and will help you get the best performance results from it.
This equipment incorporates the latest technology and offers the most advanced service on the market in the area of EV chargers.
1.1 IMPORTANT SAFETY INFORMATION
Read all the instructions before using and install this product. Do not use cables there are not in perfect conditions. Do not use this unit for anything other than electric vehicle charging. Do not modify this unit. If modified, Circontrol will reject all responsibility and the
warranty will be void.
Comply strictly with current safety regulations according to your country rules. Do not make repairs or manipulations with the unit energised. Only trained and qualified personnel should have access to low-voltage
electrical parts inside the device.
Check the installation annually by qualified technician. Remove from service any item that has a fault that could be dangerous for
users (broken plugs, caps that don’t close...).
Use only original supplied spare parts. Do not use this product if the enclosure or the EV connector is broken, cracked,
open, or shows any other indication of damage.
1.2 DESCRIPTION
Smart post charging solution is special designed to charge EV using standardized MODE 1 and MODE 3 according to European standard IEC_61851-1.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 4
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
2 FEATURES
Display: Two lines character display provide to user information of the charge
and detailed data as kWh and duration time.
Connector Lock: Type 2 connector has a lock system to avoid disconnection
of EV meanwhile is charging.
Light beacon: Three colour led indicates to user status of the wall mount unit.  RFID: Authentication and Prepayment options.  Ethernet: TCP/IP communication over an “Ethernet” compliant network
between the Wall mount and customer network is available.
3G and GPRS (optional) for remote control or OCPP integrations.  Energy metering: Integrated meter built is measuring power and energy
consumed by the EV during a charge.
Real time monitoring: Using standard browser system allows access to the
unit and monitoring charge status.
Remote control: Remote actions as start/stop charge are available.  Charge data storage: System is capable to generate graphics and reports
according to data storage from recharging historic.
OCPP integration: Standard communication protocol between charge points.
Allows charging stations connecting with central system allowing centralized authentication, user authorization in real time and a wide variety of functions related to recharge.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 5
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
3 INSTRUCTIONS FOR USE
3.1 START RECHARGING PROCEDURE
Wallbox has two status led indicators for each outlet. Green light means there is at least one outlet available and ready to start a recharge.
Present a RFID card to the right side
of the WallBox unit.
Wait until the display shows the
following message:
Plug the cable into your car. Choose one available socket in the
WallBox mount unit
Connect your cable to the unit.
Choose your plug
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 6
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
Led Status indicator of the plug
connected changes to yellow.
Display shows the following
message:
System will lock the plug
automatically.
If vehicle is not ready to charge,
this status will be permanent.
When vehicle is ready to charge led
status indicator of the plug connected will change from yellow to blue.
WallBox starts recharging. On display shows the following
information:
Charge time Real time consumed energy
PLUG A: Starting
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 7
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
3.1.1 DISPLAY INFORMATION WHILE CHARGING
The display shows in scroll mode following messages when an EV is charging:
Plug A status
Real time consumed Energy of Plug A
Plug B status
Plug A recharging elapsed time
Show card
(Only if there is an available plug)
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 8
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
3.2 STOP RECHARGING PROCEDURE
Wallbox has two status led indicators for each outlet:
Blue light means there is one outlet
busy and recharging an electric vehicle.
Green light means there is at least
one outlet available and ready to start a recharge.
Present a RFID card to the right side
of the WallBox unit for 3 seconds.
Led status indicator of the plug
connected change from blue to green.
On display shows the following
information:
IMPORTANT
For STOP recharging present same card that was used for start recharge.
PLUG A: Disconnect the
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 9
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
First, remove your cable from the
unit.
Remove cable from your vehicle.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 10
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
3.2.1 DISPLAY INFORMATION WHEN RECHARGING ENDS
The display shows in scroll mode following messages as a data summary when charge ending.
Plug A recharging elapsed time
Total consumed Energy of Plug A
Show card
(Only if there is an available plug)
Total cost of recharging the vehicle
(Free = prepayment disabled)
Total cost of recharging the vehicle
Indicates Plug A has to be disconnected.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 11
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4 ETHERNET COMMUNICATIONS
Charge station can be configured and monitorized to establish owner preferences or specific setup using integrated Ethernet communication port allocated in main controller CCL1 device.
Once service PC is configured as bellow procedure and connection established with the charge station, direct access to the device main setup page will be showed.
Charge station is shipped from the factory with default network setting of “DHCP enabled”. It means that the charge station will try to obtain an IP address from a DHCP server available on the network.
Step by step below guide detailed setup an IP address to the charging station in case there is no DHCP server available on the network.
4.1 PREREQUISITES
Below table shows, hardware and software needed to setup and IP address to the charge station.
Computer running one of the following
operating systems
- Windows XP (x86)
- Windows Vista (x86/x64)
- Windows 7 (x86/x64)
- Windows 8 (x86/x64)
Crossover Cable UTP Cat.5e or Cat6
Software needed: IPSetup.exe.
(Supplied by Circontrol)
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 12
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.2 NETWORK TOPOLOGY
Connecting pc with charge station needs to be done with static IP address and TCP/IP v4 protocol. Next section shows how to do this configuration.
Below figure shows Ethernet connection topology and the IP addresses used in this guide as example.
IP: 192.168.1.11 NETMASK: 255.255.255.0
IP: 192.168.1.10 NETMASK: 255.255.255.0
Crossover UTP
cable
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 13
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.3 STEP BY STEP LAN CONNECTION PROCEDURE
This section provides a step-by-step guide to be able to connect a laptop to the charge station in order to see real-time status.
Step
Actions
1
Click on the network icon next to the clock of the taskbar.
Click on “Open Network and Sharing Center”
2
On the left pane, click the option: “Change adapter settings”.
3
Right click on “Local Area Connection” and then click on “Properties”
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 14
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4
Select “Internet Protocol Version 4 (TCP/IP)” option and click “Properties”.
5
Setup IP address and subnet mask like as shown below:
Click OK twice to complete the process to assigning IP address to the computer.
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 15
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
7
Execute IPSetup.exe utility.
8
Enter the following parameters:
MAC of the CCL1 device (see lateral label in the device) IP address: i.e.(192.168.1.11) Netmask: i.e. (255.255.255.0) Gateway: leave default settings.
10
Wait 30 seconds approximately until the process is complete.
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 16
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
11
The process will complete when the following message appears.
If the message shown is the next one, check the following parameters.
- Check IP address entered.
- Check the MAC of the device entered.
- Try with another UTP CAT5e cable.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 17
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4 SETUP WEB PAGE
Setup web page allows managing networking setup, modem 3G setup, upgrading the device and other options.
To access to the setup web page, open a web browser and enter the following address:
NOTE: Remember to remove the quotes when entering an address into the web browser.
Direct link: http://”IP_ADDRESS”/html/setup.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 18
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.1 NETWORK SETUP
This section provides basic configuration of the network parameters.
Value
Description
Host name
Name of the device on the network
DHCP
Enable or disable the IP address assignment by a DHCP server.
DHCP Client ID
Client ID associated to the DHCP Server (If available)
Address
IP address assigned to the charge point
Netmask
Netmask of the network
4.4.2 MODEM SETUP (only for 3G series)
Devices with 3G modem integrated on the unit can enter on this section the parameters of the modem provided by the mobile network operator.
Value
Description
APN
Access point name for mobile communications
User
Parameters assigned to the APN.
Password
Reset timer (hours)
Timer to reset the modem and mobile
communications
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 19
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.3 PUBLIC ADDRESS MANAGER
This section is only for OCPP integrations and allows setting the IP address to establish connection between charge point and OCPP central system.
Value
Description
Address type
Local address: When selected, private IP address will be
sent to OCPP central system. This option is valid if the OCPP central system is connected to the same private network of the charge point.
Static address: When selected, enter a value on Public IP
textbox (IP address or a domain name).
SIERRA Wireless Raven XE H2295EW: Select this option
only when SIERRA Wireless RAVEN XE router 3G is connected on the network.
TELIT HE863: Select this option only on 3G charge points
models where modem is integrated on the CCL1 device.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 20
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.4 LOCALE SETUP
This section allows changing the language on the LCD screen.
Value
Description
Language
Allows selecting the unit language using a dropdown.
4.4.5 TIME SETUP
This section allows setting the time and region unit time.
Value
Description
Primary NTP Server
Allows to synchronize the time through internet automatically
Secondary NTP Server
Time zone
Allows selecting the regional unit time using a dropdown.
Time
Actual date and time of the unit.
Time and date synchronization of the charge point from computer connected.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 21
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.6 DYNAMIC DNS SETUP
Dynamic DNS is a system that updates in real-time the public IP address assigned to a domain name server.
Value
Description
Server
Allows selecting the type of Dynamic DNS Server using a dropdown.
Hostname
Parameters provided by dynamic DNS server.
User
Password
Server
Port
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 22
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.7 SECURITY SETUP
All of these parameters are disabled by default. When enabled, it denies unauthorized access to the web page configuration (setup.html) of the device and also prevents the export or import of a new configuration of PowerStudio engine from an unauthorized user.
Value
Description
Password
ON: authentication enabled OFF: authentication disabled
Username
Username and password authentication for setup.html web page.
New password
Password
Do not forget the credentials of the device. There is no way to reset the device to default factory settings.
It will require returning the unit to the service centre.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 23
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.8 SYSTEM INFORMATION
This section provides basically information about the unit.
Value
Description
MAC
Identifier of the network card of the unit
Version Upgrade
Version of the firmware currently installed and link to the upgrade web page
Powerstudio version
Engine version of PowerStudio
Devices status
Link that allows viewing the status of the configured devices.
4.4.8.1 SYSTEM UPGRADE
Upgrade web page allows to upgrade the firmware of the unit through a file with *.upgrade extension.
This file is provided by your installer or manufacturer of the unit.
NOTE: Remember to remove the quotes when entering an address into the web browser.
Direct link: http://”IP_ADDRESS”/html/upgrade.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 24
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.8.2 POWERSTUDIO VERSION WEB PAGE
Powerstudio version web page allows viewing the following information:
Current firmware version installed. Scada Platform version Available languages List of available driver devices that can communicate with the charge point.
NOTE: Remember to remove the quotes when entering an address into the web browser.
NOTE: it is reserved the right to change without notice the drivers on future firmware versions of
the charge point.
Firmware file transfer must not be interrupted. Failure of the file transfer involves irreversible damage to CCL1 master controller and the correct functionality of the equipment. It will require returning the unit to the service centre.
Ensure that the unit will not be affected or powered off while updating.
Direct link: http://”IP_ADDRESS”/services/system/info.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 25
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.4.8.3 DEVICES STATUS WEB PAGE
Devices status web page allows checking if all devices configured with CirCarLife Scada Editor 4.0 Software are available and working properly.
NOTE: Remember to remove the quotes when entering an address into the web browser.
4.5 OTHER URL CONFIGURATION
There are more useful web pages installed on the master device. This section shows the purpose of these web pages and how to access them.
4.5.1 LOG WEB PAGE
Log web page is a log that is created since charge point is powered ON. If charge point is restarted this log is erased and immediately is created a new one.
These logs are not recorded and no way to consult older logs if the charge point has shutdown before.
NOTE: Remember to remove the quotes when entering an address into the web browser.
Direct link: http://”IP_ADDRESS”/html/devstat.html
Direct link: http://”IP_ADDRESS”/html/log
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 26
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
4.5.2 MODEM STATUS (FOR 3G MODELS)
This website allows seeing real-time status of 3G connection.
NOTE: Remember to remove the quotes when entering an address into the web browser.
Value
Description
Connection
3G communications status.  Data access protocol used.  Cell phone signal and coverage.
IP address
Public IP assigned to the charge point.
4.5.2.1 SIGNAL LEVEL TABLE
Following table shows some possible values of the integrated modem on the charge point.
SIGNAL
DESCRIPTION
More than -80dBm
Good signal
Between -80dBm and -90dBm
Moderate signal
Less than -90dBm
Poor signal
Direct link: http://”IP_ADDRESS”/html/modem-status.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 27
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
5 3G COMMUNICATIONS (FOR 3G MODELS)
Once SIM card is inserted on CCL1 device, following parameters must be known in order to set up 3G communications and Internet access:
APN (Access Point Name) User Password
These parameters have to be provided by your mobile network operator of the SIM card inserted.
5.1 STEP BY STEP CONFIGURATION
Step by step bellow shows how to configure the 3G communications service.
Step
Action
1
Open web browser and go to: http://”IP_ADDRESS”/html/setup.html
2
Locate Modem Setup section
3
Enter following parameters (Provided by your mobile network operator)
APN User Password
4
Click on Save Setup
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 28
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
5
Go to following address: http://”IP_ADDRESS”/html/modem-status.html It is required to enter PIN number the first time that SIM card is inserted into
CCL1 device.
Enter SIM PIN and click on Confirm button.
6
After entering pin number, it shows following message:
Wait a few seconds until modem is connected on the network.
7
When the 3G connection is successful, following message will appear on the web page of modem status.
PIN number will not be required anymore after entering for the first time
and the device will start 3G communications automatically.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 29
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
Connection: Indicates the connection status and the type of connection
established.
IP address: Public IP assigned by your mobile network operator
8
OPTIONAL STEP
Finally, it is recommendable to setup parameters of Dynamic DNS for update in real-time the public IP address assigned to a domain name.
Dynamic DNS parameters can be introduced in setup web page.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 30
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6 CHARGE POINT OCPP INTEGRATION
6.1 INTEGRATION SETUP WEB PAGE
Integrations setup web page allows managing and enables the integrations available on the dropdown list.
To access to the setup web page, open a web browser and enter the following address:
NOTE: Remember to remove the quotes when entering an address into the web browser.
The selected default option is: none. When this option is set to none, there is no integration enabled on the charge point. In
this way, all RFID showed can start a rechargement.
Available options:
- OCPP 1.2: Open Charge Point Protocol (OCPP) is an open protocol between charging stations and managing central system.
Direct link: http://”IP ADDRESS”:65432
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 31
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.2 OCPP ENGINE SETUP WEB PAGE
This website allows to setup parameters of the integration selected on the previous section.
First time is running OCCP engine on the charge point, it starts as configuration mode and all fields are empty. The data is always saved even when the charge point is powered off or even the OCPP engine is stopped.
To access to the OCCP engine setup web page, open a web browser and enter the following address:
NOTE: Remember to remove the quotes when entering an address into the web browser.
Direct link: http://”IP ADDRESS”:8080
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 32
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.2.1 APPLICATION PARAMETERS
This section is for configuring the OCPP engine website. It is recommended leaving the default settings.
Value
Description
Administration TCP port
Port number where the OCPP engine website is hosted.
By default: 8080
Administrator
Administrator username.
By default: admin
New admin password
Password for administrator user.
By default: 1234
If a new password is entered, it will be applied after saving new configuration.
Repeat admin password
8080
admin
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 33
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.2.2 POWERSTUDIO ENGINE
OCPP Engine is a service running in parallel with PowerStudio and it is required to add these parameters on this section.
Value
Description
Host URL
URL where PowerStudio is hosted.
By default: http://127.0.0.1
Port
PowerStudio port. By default: 80
User – System level
Username and password authentication configured on PowerStudio.
Default factory parameters:
Username: admin
Password: 1234
Password
User – Edit level
Username and password configured in the security section of setup.html website.
Default factory parameters:
Username: anonymous
Password: anonymous
Password
http://127.0.0.1
80
admin
1234
anonymous
anonymous
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 34
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.2.3 CHARGE BOX (CB)
All of the parameters shown below must be assigned by OCPP central system administrator.
Please contact to your OCPP central system administrator to get the configuration parameters.
Value
Description
Charge Box ID
Charge point identifier
Protocol
Protocol type. If HTTPS is selected, make sure to have CS Server CA certificate.
OCPP Listening port (internal)
Listening port from charge point. Make sure the ports configured are opened on the gateway.
OCPP Listening port (public)
User (for the CB server)
Authentication parameters.
New password
Repeat password
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 35
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.2.4 OCPP SETTINGS
Select properly values according to OCPP central system parameters. Please contact to your administrator to select the correct values.
Value
Description
Use local white-list
Yes: store a list of authorised users on the charge point.
No: Authorization is consulted for each RFID card shown.
Use OCPP time synchronization
Time synchronization between charge point and OCPP central system.
Compress OCPP messages
Sending compressed messages between charge point and central system.
NOTE: Before enabling this option consult to your OCPP administrator if central system allows this function.
Energy for Start/Stop transaction
Partial: Send partial energy consumption while vehicle is charging.
Total: Send total energy values of energy meter.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 36
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
Stop charge if StartTransaction rejects the
user
Set this option according to your central system.
Heartbeat interval
Heartbeat send interval (in seconds) for the back-end system.
Connection timeout
Timeout (in seconds) before connecting to the central system.
Meter value sample interval
Meter value sample send interval (in seconds) for the back-end system.
NOTE: Put 0 seconds to send meter values only when charge point starts or stops charging a vehicle.
6.2.5 MANAGEMENT SYSTEM (CS)
This section provides to the charge point where OCPP central system is located and if it is requires authentication.
Please contact to your OCPP central system administrator to get the configuration parameters.
Value
Description
Host URL
Address where OCPP central system is located
User
Authentication for central system.
Password
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 37
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.2.6 SSL CERTIFICATES
Secure Sockets Layer (SSL) provides authentication and privacy of information between charge point and central system on Internet. Consult your OCCP central system administrator for the CS Server certificate.
Value
Description
CS Server CA certificate
Central System file certificate supplied by your central system administrator.
CB Server CA certificate
Upload charge box file certificate supplied with charge point unit.
6.2.7 ACTIONS
Final options to complete the OCCP engine configuration.
Value
Description
Save settings and apply.
Restore data entered.
Import using a configuration XML file.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 38
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
6.3 STEP BY STEP INTEGRATIONS PROCEDURE
Step
Action
1
Open web browser and enter following address:
This page allows selecting and enabling the integration type on the CCL1 device.
2
By default, there is no integration configured on the CCL1.
Select desired integration and click on Save setup button.
4
Enter a new address on the web browser:
This page allows setup the integration enabled in previous steps.
5
Fill the blank fields following parameters as your central system administrator. Click on Save setup to confirm.
Direct link: http://”IP ADDRESS”:65432/
Direct link: http://”IP ADDRESS”:8080/
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 39
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
7
Enter a new address on the web browser:
Locate Public address Manager section shown as below:
The selected default option is: Local address
To configure CCL1 3G series go to next step. To configure CCL1 without 3G connectivity go to step number 9.
8
This step is only for CCL1 3G series.
Change address type from “Local address” to “TELIT HE863” on Public address Manager section inside Setup web page.
To finish go to step 10.
Direct link: http://”IP_ADDRESS/html/setup.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 40
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9
This step is only for CCL1 or other devices without 3G connectivity.
1. Change address type from “Local address” to “Static address” on Public address Manager section inside Setup web page.
2. Enter Public IP address or a domain name.
To finish go to next step.
10
Click on Save setup to confirm.
Wait a few seconds until CCL1 restarts.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 41
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
7 URL SUMMARY TABLE
Following table shows a summary of the entire URL available as described in previous sections.
DESCRIPTION
URL
Setup
http://”IP_ADDRESS”/html/setup.html
Upgrade
http://”IP_ADDRESS”/html/upgrade.html
PowerStudio version
http://”IP_ADDRESS”/services/system/info.html
Devices status
http://”IP_ADDRESS”/html/devstat.html
Log
http://”IP_ADDRESS”/html/log
Modem status
http://”IP_ADDRESS”/html/modem-status.html
Integration enable/disable
http://”IP_ADDRESS”:65432
Integration engine configuration
http://”IP_ADDRESS”:8080
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 42
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
8 CHARGE STATION MONITORING
The IP address assigned in last section it will be useful to connect to the charge station to monitor the real-time status.
Exist two ways to connect to the charge station:
- CirCarLife client software. (Supplied by Circontrol)
- Internet web browser.
8.1 USING CIRCARLIFE CLIENT
Step
Action
1
Execute CirCarLife Client software.
2
Go to: General -> Connect
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 43
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
3
Enter IP address and port shown in the last example.
- IP address:
- Port: 80
Click OK to connect to the charge point.
8.2 USING WEB BROWSER
It is needed to have installed the latest version of java to access to the monitoring page. Download it from: www.java.com
Step
Action
1
Execute your web browser and enter the following address: i.e.(http://IP_ADRESS) (monitor page will open automatically)
2
Wait while the client software is starting.
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 44
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9 CIRCARLIFE SCADA CLIENT
CirCarLife Scada client software allows displaying and reporting all parameters generated by devices connected to the engine of the charge point.
Client platform is implemented in Java and can be executed on many devices.
Devices connected to the charge point may vary depending on model purchased.
CirCarLife Scada client is divided on 4 sections:
1. Menu bar
2. Toolbar
3. Screen information
4. Status bar
Following section describes in detail each of the points mentioned above.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 45
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.1 MENU BAR
Menu bar is located at the top and provides access to all available client features. There are three main menus, "Options", "Views" and "General".
9.1.1 OPTIONS MENU
Option
Description
Properties
Displays properties of the currently active view. This option can be active or not depending on the view in progress.
Print
Print currently active view. This option can be active or not depending on the view in progress.
Export
Exports currently active view. This option can be active or not depending on the view in progress.
Exit
Close the client software.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 46
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.1.2 VIEWS MENU
Option
Description
Previous
Displays the previous view.
Next
Displays the next view (If available).
Historic
Displays any view previously consulted.
Study
Displays graph and tables views.
Devices
Device list shortcut.
Events
Displays the events log or the active events window.
Device status
Display the general status of all connected devices.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 47
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.1.3 GENERAL MENU
Option
Description
Toolbar
Displays or hides the toolbar.
Statusbar
Displays or hides the status bar.
Alarm if it not communicate
Audible alarm if communication is lost between charge point and computer connected.
Events actions
List of actions enabled in the client software.
Connect
Connects with another CirCarLife Engine.
Logout
Closes the current session. Only available when the user has connected to engine that requires authentication.
Language
Changes the client application language.
Look and feel
Changes the appearance of the client application (Skin).
Graphs properties
Changes graph appearance.
About
Displays client application information.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 48
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.2 TOOLBAR
Toolbar contains the most frequent options used in the client software.
Option
Description
Previous
Displays the previous view.
Next
Displays the next view. If available.
Down arrow
Displays any view previously consulted.
Devices
Device list shortcut.
Graph
Creates a graph.
Table
Creates a table.
Events
Displays event history
Properties
Displays the properties window of the current view.
Print
Allows us to print the current view.
9.2.1 TOOLBAR SETUP MENU
It is possible to hide or display buttons for the toolbar. Right-click on the toolbar and following setup menu appears:
NOTE: The toolbar may be hidden using the “General” menu. The menu bar may be hidden
using the “Enable menu and toolbar” option in the editor “Preferences”. Using this latter method it will not be possible to make it appear again from the client application.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 49
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.3 STATUS BAR
Status bar is located at the bottom of the client software and it contains general information about status of CirCarLife Scada engine connected.
OVERVIEW
Status
Description
Online CirCarLife Scada engine and working properly.
Offline CirCarLife Scada engine.
Incidences
Description
One or more devices are not communicating.
See device status section to find witch device is not communicating.
One or more devices are not reporting.
One or more events are active.
Double-click over icon showed to see details.
NOTE: Status bar can be hidden using the "General” option in the client application menu. It
may also be hidden using the “Enable menu and toolbar” option in editor “Preferences”. In the
latter case it will not be possible to make it appear again from the client application.
Engine status
Engine name, IP and port
Incidences
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 50
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.4 SCADA GRAPHS
One of the most powerful tools of client software is graphs tools of the devices. Following image shows variables selection window under CCL1Engine where it is
possible to select Plug A and Plug B on the charge point.
At first it appears the available plugs from the charge station. Select the desired plug to proceed with the creation of the graph.
The system automatically chooses the representation period and the grouping of data, which can obviously be changed later.
Default parameters should be displayed as a week and the time period is typically 30 minutes.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 51
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
Picture bellow shows the aspect of the graph generated by the client software.
Graph tool has following sections:
Title: Situated on the upper area. It is a text describing the represented
variables.
Representation areas: Data represented by bars for energy or by lines for
power. Each area contains some common characteristics:
- Key: Provides general information about the variables that are represented in the area.
- Y-Axis: Provides information on the units of the variables that are represented in this axis and the range of values that are being displayed.
- X-axis: Typically, this is the time axis and is located at the bottom of the representation area. Here the time interval being represented may be seen. Usually predefined time intervals are represented (day, month, etc.). But the user can choose the most suitable as can be seen later.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 52
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
- Drawing area: Contains the actual figure representing the variables of the area in question. There is a drawing area for each area of representation.
Graph toolbar: Contains a series of actions that can be performed on the
graph. Depending on the type of graph it will contain more or fewer options.
9.4.1 GRAPHS TOOLBAR
Graphs always have a toolbar at the bottom of the window that allows different actions related to the data represented.
Option
Description
Back
Displays the previous interval of data.
Next
Displays the next interval of data.
Go to
Allows choosing a closed graph interval.
Grouped by
Allows choosing standard graph interval by day, week, month or year.
Period
Sampling period variables.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 53
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.5 SCADA TABLES
Another important client tool is Scada table tool. First, it is necessary to choose the device to display its recorded variables and click on
table button option. Once table button is pressed, a discriminator window appears:
CCL1Engine has two types of tables:
- Standard: sampling variable (energy, power, voltage) depending on the meter installed on the charge point.
- Charge: summary of recharges on the charge point.
Following image shows the appearance of table recharges:
Table tool has following sections:
Title: data period displayed.  Body: it contains a series of columns with the values registered.  Toolbar: personalization data showed in the table.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 54
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
Table toolbar has same options and functionality as explained on toolbar graphs section.
9.5.1 TABLE PROPERTIES
It is possible to configure some aspects using the table Properties option. This option can be accessed using the “Options” menu, “Properties submenu, or directly with the Properties button on the main toolbar.
Table properties window
Using this option it is possible to add new variables to the table in the same way as they are added to the graph, by clicking on Add.
It is also possible to delete variables from the table selecting the desired variables and clicking on the “Delete” button.
User can print the current graph displayed using “Print” option on the “Options” menu of the main menu or the Print button of the upper toolbar.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 55
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
9.6 NOTIFIED EVENTS
CirCarLife Scada client enables current events to be viewed in real time, both the simple events that are active as well as those that must also be acknowledged by the user.
Events not requiring user acknowledgement are displayed in a pop-up window, which may be accessed via the Views menu option, then Events and finally Active events or directly from the status bar by clicking on the icon indicating there are active events in the system.
Notified events window
Note that an event with an acknowledgement date and a deactivation date will disappear from the list of events reported.
This window allows event acknowledgement. Select from the events to be acknowledged from the events list and click the Recognize events” button at the bottom. The event acknowledgement date is shown. When an event is disabled it will disappear from the list. If a previously acknowledge event is acknowledged again the operation will not produce any effect.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 56
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
10 CCL1 ENGINE
CCL1 engine is the application of recharging Wallbox Smart and it is showed as a main screen when CirCarLife Scada client is connected on the CCL1 device.
Following image shows the aspect of the charge point engine:
The engine is divided on two sections:
- Bollard state: describes general state of the charge point.
- Plug status: plug status and other useful information.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 57
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
10.1 BOLLARD STATE SECTION
This section describes the general state of charge point.
Any of these options may not appear on the charge point. It depends on the hardware of the unit purchased or by software configuration.
Status
Leakage
Charge point leakage status
Normal operation
Channel 3 tripped
Tamper switch
Tamper switch status
Normal operation
Rear cover removed
Tilt (sensor inside CCL1 device)
Charge point tilt status
Normal operation
Charge station tilted
If any of the points mentioned above is in status, charge point will be out of service (plug A and plug B) until event is resolved.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 58
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
10.2 PLUGS SECTION
This section describes the plug status and other useful information. Each plug looks the same configuration as shown below:
Following table shows the status of each option showed on plug section.
Description
Status
Plug status
Plug available
Starting
recharge
Plug in use
Fault
Car connected
Vehicle connection status
Car connected
Car not connected
Connector lock
Connector lock status
Locked plug
Unlocked plug
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 59
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
Description
Reserved
Reservation status
0 = No reservation
Charge
Starts a charge from remotely point.
Stop charging in progress
Pauses charging in progress.
Enable
Enable or disable the plug.
Leakage
RCD plug status.
Normal operation
Channel 1 or 2 tripped
Charge relay
Indicates contactor status
Voltage is being supplied to the vehicle.
No voltage is being supplied to the vehicle.
Active Energy (kWh)
Total charge measured energy
Partial active energy
(kWh)
Partial energy meter of the last charge
Charge request date
Date of the last charge request
Charge begin date
Starting date of the last charge
Charge end date
End date of the last charge
Charge time
Duration of the last charge
Last charge stop
Reason for the last charge stop.
Status: Reserved
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 60
Web: www.circontrol.com – E-mail: circontrol@circontrol.com
WALLBOX SMART – INSTRUCTION MANUAL
C / Innovació, 3
Pol. Ind. Can Mitjans
08232 - Viladecavalls
Barcelona - Spain
Tel: +34 937 362 940
Fax: +34 937 362 941
www.circontrol.com
Loading...