CipherLab 1260S barcode manual

Page 1
Table of Contents
Restore Default Settings .......................................................................................1
Exit Setup without Changes.................................................................................1
Set Connection....................................................................................................... 1
RF Auto Shutdown Duration...............................................................................1
Memory Mode Parameters...................................................................................2
List Setting.............................................................................................................3
Buzzer Settings......................................................................................................3
Reading Redundancy Setting...............................................................................4
Scan Mode Setting.................................................................................................4
Auto-Sense Setting ................................................................................................4
Scanner Time-out Duration..................................................................................5
Negative Barcode Setting .....................................................................................5
Delay between Reread ..........................................................................................5
Keyboard Wedge Parameters..............................................................................6
Laptop Support.....................................................................................................8
RS-232 Parameters...............................................................................................9
Bluetooth Serial Port Parameters......................................................................11
Prefix / Postfix Settings.......................................................................................12
Character Substitution.......................................................................................12
Code ID Selection................................................................................................12
Code ID Setting...................................................................................................13
Length Code Setting (2 digits)............................................................................14
Select Readable Codes........................................................................................17
Code39 Parameters.............................................................................................22
Italy Pharmacode Parameters............................................................................22
French Pharmacode Parameters.......................................................................23
Industrial 25 Parameters....................................................................................23
Interleave 25 Parameters....................................................................................24
Matrix 25 Parameters.........................................................................................26
Codabar Parameters...........................................................................................27
Plessey Parameters..............................................................................................28
Telepen Parameters............................................................................................28
MSI Parameters..................................................................................................29
MSI Parameters..................................................................................................29
EAN128 Parameters ...........................................................................................30
EAN8 Parameters ...............................................................................................31
UPCA Parameters...............................................................................................31
UPCE Parameters...............................................................................................32
EAN13 Parameters .............................................................................................33
RSS Code ID Selection........................................................................................34
RSS14 Parameters...............................................................................................34
RSS Limited Parameters....................................................................................35
RSS Limited Parameters....................................................................................35
Activate Editing Formats...................................................................................36
Editing Format Parameters...............................................................................37
Decimal Digits.....................................................................................................49
Hexadecimal Digits.............................................................................................50
RS-232 Character Table.....................................................................................51
Page 2
Restore Default Settings Memory Mode Parameters
Set Connection
*
Programming Instructions : (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired 3660 Base Station within 5 seconds to complete this setting.
RF Auto Shutdown Duration
*
Programming Instructions : (1) Read the label. (2) Program the desired auto shutdown duration (in minutes) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Memory Mode
Enable
< Disable >
Clear Data
Clear
Confirm
Send Data
Memory Data Delay
< 0 >
8 sec
250 ms
500 ms
1 sec
2 sec
3 sec
5 sec
Update
1
2
Enter Setup
Page 3
List Setting Reading Redundancy Setting
Page1
Page 10
Page 6
Page 2
Page 7
Page 3
Page 8
Page 4
Page 9
Page 5
Buzzer Settings
< Buzzer Enable>
Buzzer Disable
< No Redundancy >
3 Times
4 Times
2 Times
Scan Mode Setting
Auto Off Mod e
Auto Power O ff Mode
Momentary Mode
Laser Mode
Test Mode
< Continuous Mod e >
Alternate Mode
Repeat Mode
Buzzer Frequency
8 kHz
1 kHz
< 4 kHz >
2 kHz
Update
3
Auto-Sense Setting
Enable
< Disable >
4
Enter Setup
Page 4
Scanner Time-out Duration
*
Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Negative Barcode Setting
Enable
< Disable >
Delay between Reread
100 ms
< 400 ms >
5 sec
200ms
800 ms
1 sec
2 sec
3 sec
Keyboard Wedge Parameters
Activate and Select Keyboard Type
*
Programming Instructions : (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Keyboard Table
No. Keyboard Type
1 PCAT (US) 2 PCAT (French) 3 PCAT (German) 4 PCAT (Italy) 5 PCAT (Swedish) 6 PCAT (Norwegian) 7 PCAT (UK) 8 PCAT (Belgium)
9 PCAT (Spanish) 10 PCAT (Portuguese) 11 PS55 A01-1 12 PS55 A01-2 13 PS55 A01-3 14 PS55 001-1 15 PS55 001-81 16 PS55 001-2 17 PS55 001-82 18 PS55 001-3 19 PS55 001-8A 20 PS55 002-1, 003-1 21 PS55 002-81, 003-81 22 PS55 002-2, 003-2 23 PS55 002-82, 003-82 24 PS55 002-3, 003-3 25 PS55 002-8A, 003-8A 26 IBM 3477 (Japanese) 27 PS2-30 28 IBM 34XX/319X, Memorex Telex 122 Keys
Update
5
6
Enter Setup
Page 5
Keyboard Alphabets Layout Alphabet Transmission
< Default Layout >
QWERTZ
Keyboard Digits Layout
< Default Layout >
Upper Row
Keyboard Capital Lock Type
< Default >
Capital Lock
Capital Lock Setting
Capital Lock ON
Auto Detection
AZERTY
Lower Row
Shift Lock
< Capital Lock OFF >
< Case Sensitive >
Ignore Case
Digits Transmission
< Alphanumeric Key >
Numeric Key
Alt Composing
Yes
< No >
Inter-Character Delay
Programming Instructions : (1) Read the label. (2) Program the desired inter­character delay by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
*
Laptop Support
< Disable>
Enable
Update
7
8
Enter Setup
Page 6
RS-232 Parameters
Activate RS232 Interface
Baud Rate
115200
300
19200
4800
1200
38400
< 9600 >
2400
Flow Control
< None >
Data Ready
INV. Data Ready
Scanner Ready
Inter-Character Delay
*
Programming Instructions : (1) Read the label. (2) Program the desired inter­character delay by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Parity
Even
< No Parity >
Odd
Data Bit
< 8 >
7
Update
9
10
Enter Setup
Page 7
Bluetooth Serial Port Parameters Prefix / Postfix Settings
Activate BlueTooth Serial Port Interface
Device Name Broadcasting
< Yes >
No
Authentication
Yes
< No >
PIN Code
*
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. (4) Max 6 characters for this PIN Code setting.
Prefix Code *
Postfix Code *
Character Substitution
Set 1 *
Set 3 * Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Set 2 *
Code ID Selection
Clear All Code ID Settings
Select Code ID Set
Update
Set 1
Set 5
11
12
Set 3
Set 2
Enter Setup
Set 4
Page 8
Code ID Setting Length Code Setting (2 digits)
Code 39 *
French Pharmacode *
Interleave 25 *
Codabar *
UPCE *
EAN13 *
Code 128 *
Plessey *
Telepen * Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Italy Pharmacode *
Industrial 25 *
Matrix 25 *
UPCA *
EAN8 *
Code 93 *
MSI *
Code 39 Length Code
Enable
< Disable >
Italy Pharmacode Length Code
Enable
< Disable >
French Pharmacode Length Code
Enable
< Disable >
Industrial 25 Length Code
Enable
< Disable >
Interleave 25 Length Code
Enable
< Disable >
Update
13
14
Enter Setup
Page 9
Matrix 25 Length Code Code 93 Length Code
Enable
< Disable >
Codabar Length Code
Enable
< Disable >
UPCA Length Code
Enable
< Disable >
UPCE Length Code
Enable
< Disable >
Enable
< Disable >
Code 128 Length Code
Enable
< Disable >
EAN128/RSS Length Code
Enable
< Disable >
MSI Length Code
Enable
< Disable >
EAN8 Length Code
Enable
< Disable >
EAN13 Length Code
Enable
< Disable >
Update
15
Plessey Length Code
Enable
< Disable >
Telepen Length Code
Enable
< Disable >
16
Enter Setup
Page 10
Select Readable Codes
Code 39
< Enable >
Disable
Italy Pharmacode
Enable
< Disable >
French Pharmacode
Enable
< Disable >
Industrial 25
< Enable >
Disable
Matrix 25
Enable
< Disable >
Codabar
< Enable >
Disable
Code 93
< Enable >
Disable
Code 128
< Enable >
Disable
EAN128
Interleave 25
< Enable >
Disable
Update
17
Enable
< Disable >
MSI
Enable
< Disable >
18
Enter Setup
Page 11
Plessey
Enable
< Disable >
Telepen
Enable
< Disable >
UPCA
< Enable No Addon >
Enable Addon2
Enable Addon5
< Disable Addon5 >
Disable No Addon
< Disable Addon2 >
UPCE
< Disable Addon5 >
< Enable No Addon >
Enable Addon2
Enable Addon5
Disable No Addon
< Disable Addon2 >
EAN8
< Enable No Addon >
Enable Addon2
Enable Addon5
< Disable Addon5 >
Disable No Addon
< Disable Addon2 >
Update
19
20
Enter Setup
Page 12
EAN13
< Enable No Addon >
Enable Addon2
Enable Addon5
< Disable Addon5 >
Disable No Addon
< Disable Addon2 >
RSS14
Enable
< Disable >
RSS Limited
Code39 Parameters
Standard / Full ASCII Code39
< Standard >
Full ASCII
Start / Stop Transmission
Enable
< Disable >
Checksum Verification
Enable
< Disable >
Enable
< Disable >
RSS Expanded
Enable
< Disable >
Update
21
Checksum Transmission
< Enable >
Disable
Italy Pharmacode Parameters
Checksum Transmission
< Enable >
Disable>
22
Enter Setup
Page 13
French Pharmacode Parameters
Checksum Transmission
< Enable >
Disable
Industrial 25 Parameters
Start / Stop Selection
< Industrial 25 >
Matrix 25
Interleave 25
Checksum Verification
Enable
< Disable >
Checksum Transmission
Max / Min Code Length Qualification
Select Max / Mi n Length Qualification
Max Length *
Min Length *
Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Interleave 25 Parameters
Start / Stop Selection
< Enable >
Disable
Update
23
Industrial 25
Matrix 25
24
Enter Setup
< Interleave 25 >
Page 14
Checksum Verification
Enable
< Disable >
Checksum Transmission
< Enable >
Disable
Max / Min Code Length Qualification
Select Max / Mi n Length Qualification
Max Length *
Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Matrix 25 Parameters
Start / Stop Selection
Industrial 25
< Matrix 25 >
Checksum Verification
Interleave 25
Update
Enable
< Disable >
Checksum Transmission
< Enable >
Disable
25
26
Enter Setup
Page 15
Max / Min Code Length Qualification Start / Stop Selection
Select Max / Mi n Length Qualification
Max Length *
Min Length *
Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Codabar Parameters
< abcd / abcd >
ABCD / AB CD
ABCD / TN*E
abcd / tn*e
Plessey Parameters
Convert to UK Plessey
Enable
< Disable >
Checksum Transmission
< Enable >
Disable
CLSI Conversion
Enable
< Disable >
Start / Stop Transmission
Enable
< Disable >
Update
27
Telepen Parameters
Telepen Output
< AIM Telepen >
Original Telepen
28
Enter Setup
Page 16
MSI Parameters
Checksum Verification
< Single Modulo 10 >
Modulo 11 & 10
Checksum Transmission
< Last digit not Transmitted >
Last 2 Digits not Transmitted
Max / Min Code Length Qualification
Select Max / Mi n Length Qualification
Double Modulo 10
Transmitted
Fixed Code Length Qualification
Select Fixed Length Qualification
Fixed Length 1 *
Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
EAN128 Parameters
Code ID Transmission
Enable
< Disable >
Field Separator
Max Length *
Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Update
29
*
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
30
Enter Setup
Page 17
EAN8 Parameters UPCE Parameters
Convert to EAN13 System Number Selection
Enable
< Disable >
Checksum Transmission
< Enable >
Disable
UPCA Parameters
Convert to EAN13
< Enable >
Disable
System Number Transmission
< Enable >
Disable
System Number 0 and 1
< System Number 0 only >
Convert to UPCA
Enable
< Disable >
System Number Transmission
Enable
< Disable >
Checksum Transmission
< Enable >
Disable
Checksum Transmission
< Enable >
Disable
Update
31
32
Enter Setup
Page 18
EAN13 Parameters RSS Code ID Selection
ISBN Conversion
Enable
< Disable >
< ]e0 >
]C1
RSS14 Parameters
ISSN Conversion
Code ID Transmission
Enable
< Disable >
Checksum Transmission
< Enable >
Disable
< Enable >
Disable
Application ID Transmission
< Enable >
Disable
Update
Checksum Transmission
< Enable >
Disable
33
34
Enter Setup
Page 19
RSS Limited Parameters Activate Editing Formats
Code ID Transmission Format 1
< Enable >
Disable
< Disable >
Application ID Transmission Format 2
< Enable >
Disable
< Disable >
Checksum Transmission Format 3
< Enable >
Disable
RSS Limited Parameters
Code ID Transmission
< Enable >
Disable
< Disable >
Exclusive Data Editing
< No >
Apply Editing Format to Telepen
Enable
Enable
Enable
Yes
Update
< Yes >
No
35
36
Enter Setup
Page 20
Editing Format Parameters
Format Selection
Format 1
Format 3
Restore Default Format
Format 2
Applicable Data Length
Maximum Length *
Minimum Length * Programming Instructions : (1) Read the label. (2) Program the desired length by
reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Matching String of Applicable Data
*
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Location of Matching String
*
Update
Programming Instructions : (1) Read the label. (2) Program the desired location by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
37
38
End of Format Programming
Page 21
Total Number of Fields Applicable Code Type
1
6
4
2
3
5
All
French Pharmacode
Interleave 25
UPCE No Addon
UPCE Addon5
EAN8 Addon2
EAN8 Addon5
Code 39
Codebar
Code 128
Clear
Italy Pharmacode
Industrial 25
Matrix 25
EAN128 / RSS
UPCE Addon2
EAN8 No Addon
Code 93
Update
39
40
End of Format Programming
Page 22
EAN13 No Addon
EAN13 Addon5
UPCA Addon2
MSI
Plessey
EAN13 Addon2
UPCA No Addon
UPCA Addon5
Field1 Setting
Divide Field by
Field Terminating String
Field Terminating String *
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Include Terminating String
Discard Terminating String
Divide Field by Field Length
Field Length *
Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Update
41
42
End of Format Programming
Page 23
Field2 Setting Field3 Setting
Divide Field by
Field Terminating String
Field Terminating String *
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Include Terminating String
Discard Terminating String
Divide Field by Field Length
Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Field Length *
Divide Field by
Field Terminating String
Field Terminating String *
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Include Terminating String
Discard Terminating String
Divide Field by Field Length
Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Field Length *
Update
43
44
End of Format Programming
Page 24
Field4 Setting Field5 Setting
Divide Field by
Field Terminating String
Field Terminating String *
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Include Terminating String
Discard Terminating String
Divide Field by Field Length
Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Field Length *
Divide Field by
Field Terminating String
Field Terminating String *
Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Include Terminating String
Discard Terminating String
Divide Field by Field Length
Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Field Length *
Update
45
46
End of Format Programming
Page 25
Additional Fields Setting Field Transmission Sequence
Additional Field 1 *
Additional Field 2 *
Additional Field 3 * Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Additional Field 4 *
Additional Field 5 *
Start
Field 1
Field 2
Field 3
Field 4
Field 5
Field 6
Additional Field 1
Additional Field 2
Additional Field 3
Additional Field 4
Additional Field 5
Update
End
Programming Instructions : (1) Read the “Start” label. (2) Program the desired transmission sequence by reading the Field / Additional Field labels. (3) Read the “End” label to complete this setting.
47
48
End of Format Programming
Page 26
Decimal Digits Hexadecimal Digits
0
9
5
1
2
3
4
6
7
8
Validate
0
F
8
1
2
3
4
5
6
7
9
A
B
C
D
E
Update
Validate
49
50
Enter Setup
Page 27
RS-232 Character Table
3450 1 2 6 7 0 DLE SP 0 @ P ` p 1 SOH DC1 ! 1 A Q a q 2 STX DC2 " 2 B R b r 3 ETX DC3 # 3 C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB ' 7 G W g w 8 BS CAN ( 8 H X h x 9 HT EM ) 9 I Y i y
A LF SUB * : J Z j z B VT ESC + ; K [ k { C FF FS , < L \ l | D CR GS - = M ] m } E SO RS . > N ^ n ~ F SI US / ? O _ o DEL
Update
51