Cino FUZZYSCAN WIRELESS IMAGER REFERENCE MANUAL International Edition, REV A8

WIRELESS IMAGER
Reference Manual
International Edition, Rev. A8
Wireless FuzzyScan
Spain (QWERTY) to Spain (Spanish QWERTY), Latin America (QWERTY) to
Revision History
Rev. No. Released Date Description
Rev. A Oct 16, 2009 First Release
Rev. A1 Oct 22, 2009
Rev. A2 Nov 27, 2009
Rev. A3 Mar 05, 2010
Rev. A4 Apr 27, 2010
Rev. A5 Jun 28, 2010
Rev. A6 Sep 20, 2010
Page 6 Revise “Clone Function” operation method. Page 68 Add “Save Configuration” and “Master Default” to System Commands.
Page 53 “Bluetooth Device Name” – Modify user define characters from 1 – 14
characters to 1 – 16 characters.
Page 69 Add “Indications”.
Page 25 Modify UPC-E/EAN-8 expansion and UPC-A standardization. Page 43 Rename “Time Out Control” to “Serial Response Time-out”. Page 45 Rename “Presentation Scanning Mode” to “Presentation Control”. Page 48 Rename “Auto Power Off Duration” to “Light Source On Time”.
Add “Extremely short” option to Good Read Duration. Page 49 Rename “Presentation Scanning Auto-sense” to “Presentation Auto-sense”. Add “Presentation Sensitivity”
Page 38 Hands Free Time-out – Add “Disable”. Page 43 Baud Rate – Add 57.6K BPS and 115.2K BPS.
Page 27 Add “UPC/EAN Security Level”. Page 49 Add “Time Delay to Low Power Trigger” Page 47 Add “Good Read Indicator”. Page 48 Add “Scan Voting”.
Page 25,26 Rename ”Scan Voting” to “Supplement Scan Voting” and add “Supplement
Scan Voting” in Symbology Reading Control
Page 27 Add “EAN Supplement Control” Page 38 Keyboard Layout – Add “Czech (QWERTY)”, remove “Universal”, and rename
Spain (Latin America, QWERTY)
Wireless FuzzyScan
parameter selection in Batch Data
Revision History
Rev. No. Released Date Description
Page 48 Remove ”Scan Voting” and add “Scan Rate Control ”
Rev. A6 Sep 20, 2010
Page 54 Add “<Scanned Data><Field Delimiter><Quantity>
Quantity Output Format
Rev. A7 Nov 10, 2010
Rev. A8 Jan 2, 2011
Page 44 Baud Rate – Cancel Baud Rate 300/600 BPS.
Page 47 Buzzer Tone Adjust – Modify No power-on beep behavior. The setting of
No power-on beep will impact both Bluetooth Scanner and Smart Cradle. Add “Beeping Control” setting.
Wireless FuzzyScan
© Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd
Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied, reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written permission of Cino. All product information and specifications shown in this document may be changed without prior notice.
Warranty
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA procedures to return Cino for inspection.
Regulatory
LED Eye Safety
FCC part 15B, FCC part 15C
EN55022, EN55024, EN60950-1, EN301 489-1 & 489-17, EN300 328
CNS13438, CNS14336
LP0002
MIC T401
IEC60825-1, EN60825-1
Wireless FuzzyScan
Table of Contents
Getting Started
Getting Familiar with Your FuzzyScan 1 Preparation before Using 2 Decide Your Radio Link Mode 3 Using FuzzyScan in PAIR Mode 4 Using FuzzyScan in PICO Mode 5 Using FuzzyScan in HID Mode 7 Using FuzzyScan in SPP Mode 8 Out-of-range Scanning/Presentation Scanning/Paging Function 10 Batch Scanning (Inventory Mode) 11
Configure Your FuzzyScan
Bar Code Programming Manual 13 Programming Procedures 14 Host Interface Selection 18 Symbology Reading Control 19 Keyboard Interface Control 38 Serial Interface Control 42 Wand/Laser Emulation Control 45 Operation Control 46 Condensed DataWizard 56
Appendix
Symbology ID Table 63 Keyboard Function Code Table 64 ASCII Input Shortcut 65 Link Mode Quick Set/Operation Mode Quick Set 66 Host Interface Quick Set 67 Option Codes 68 System Commands 69 Indications 70
Wireless FuzzyScan
Getting Started
Getting Familiar with Your FuzzyScan
Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge FuzzyScan 2.0 Imaging Technology and Bluetooth 2.1 EDR wireless technology, it not only provides outstanding reading performance, but also delivers the convenience and freedom of mobility. This document provides a quick reference for installation and operation purposes. The complete documentation is available at www.cino.com.tw.
F700BT Series Scanner HB2110 Smart Cradle (Base)
F600BT Series Scanner HB2100 Charging Cradle (Base)
Link Indicator
Status Indicator
Beeper
Scan Window
Trigger
Reset Button
Battery Cavity
End Cap
Center Indicator
Side Indicators
Paging/Reset Button
Host Interface Port
DC Power Jack
Power Indicator
Reserved
Reserved
DC Power Jack
1
Wireless FuzzyScan
Preparation before Using
power plugs in your power supply kit. Choose the appropriate local
Plug the DC power cord of the power supply unit into the DC power jack of the cradle.
one
lease check the power indicator of the
if
Ensure the battery co
of the battery pack are facing the charging contacts inside
e battery pack into the battery cavity until hearing a click sound before locking it
with the end cap.
beeps when the battery pack is installed
Install the Battery
Charging the Battery
Slide th
properly if the battery pack still has power.
Secure the end cap with the screw provided, and make sure the end cap is secured properly before using the scanner.
There are 4 different plug and slot it onto the power adapter cavity until it is locked.
Plug the AC power plug into the appropriate AC wall socket.
The smart cradle will issue the power on beeps and the center indicator will give blue blink. If you use the charging cradle, p charging cradle turns steady blue.
Place the scanner on the cradle. The status indicator of scanner will turn steady red the battery is not fully charged. When the battery is fully charged, the status indicator of scanner will flash green at regular interval.
Getting Started
ntacts
the battery cavity.
The scanner will give 4
Please charge the new battery pack for 8 hours prior to the first use.
2
Wireless FuzzyScan
Getting Started
Decide Your Radio Link Mode
The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to one connection) or PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled IT assets. Moreover, you are also able to use the scanner to work with Bluetooth-enabled host devices via SPP master/slave modes and HID mode.
After losing the radio link, the scanner is capable of resuming the radio connection automatically while it returns to the communication coverage. But please note that this feature is not available in SPP slave mode. If you would like to change the radio link mode, you have to scan the “Uninstall” command to revert the scanner to uninstall state.
PAIR Mode
If the Bluetooth device is not available in your existing system, this is the simplest plug-and-play solution. In this mode, one scanner can only work with one smart cradle. The smart cradle not only provides the Bluetooth radio link with the scanner, but also offers the legacy cabled interfaces to the host device, including USB HID, USB COM, PS/2(DOS/V) Keyboard Wedge and RS232 Serial.
PICO Mode
For the requirement of multiple connections, up to 7 scanners can be connected to one smart cradle concurrently. If you would like to un-pair all paired scanners and smart cradle, you can simply press and hold the paging/reset button of the smart cradle for over 3 seconds. If you just want to un-pair part of the paired scanners, please take those paired scanners to scan the “Uninstall” command one by one.
HID Mode
Through the most helpful HID service, the scanner can work like a Bluetooth keyboard. In this mode, the scanner is discoverable by the radio connection request issued by a remote host device. For security purpose, you will be requested to input the PIN Code to establish the Bluetooth connection in most time.
SPP Master/Slave Mode
Through the standard SPP service, the scanner can work like a serial input device. In SPP master mode, the scanner initiates the radio connection request to a remote slave device. In SPP slave mode, the scanner is discoverable by the radio connection request issued by a remote master device.
3
Wireless FuzzyScan
Getting Started
Using FuzzyScan in PAIR Mode
Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details.
Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device.
USB
Turn on the power of your host device.
Please note that the scanner has been pre-paired already, if the scanner is shipped together with the smart cradle. You will see the link indicator of scanner gives 1 blue blink per 2.5 seconds and the middle indicator of smart cradle turns steady blue. If the scanner and smart cradle just give alternating red and green blinks (in “Uninstall” state), please follow steps 5-6 to establish the connection between the scanner and the smart cradle.
Scan “PAIR mode” command. The status indicator of scanner will turn steady red.
PS/2 RS232
Uninstall
PAIR Mode
Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process. When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner giving 1 blue blink per 2.5 seconds and the center indicator of the smart cradle turning steady blue.
If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do” beeps to indicate pair failure, the scanner will return to uninstall state automatically.
Scan the corresponding host interface quick set command to complete the installation.
The default host interface of smart cradle is preset to USB HID. If you want to set the host interface to USB COM, you have to
install the USB virtual COM driver into your host device before using the scanner. Please visit the CINO website to download
the software driver.
4
Wireless FuzzyScan
Getting Started
Using FuzzyScan in PICO Mode
Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device.
Turn on the power of your host device.
Ensure the side indicators of the smart cradle give alternative red and green blinks (in “Uninstall” state). If the smart cradle is paired with other scanners, you can press and hold the paging/reset button for over 3 seconds to un-pair all paired scanners. Then the smart cradle will return to uninstall state automatically.
Prepare the scanners you desire to pair with smart cradle. Ensure the status indicator of each scanner give alternative red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command to un-pair the scanner. Then scan the “PICO mode” command, and the status indicator of scanner will turn steady red.
USB PS/2 RS232
Uninstall
Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process. When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner giving 1 blue blink per 2.5 seconds, the center indicator of the smart cradle turning steady blue and its side indicators turning steady green.
If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do” beeps to indicate pair failure, the scanner will return to uninstall state automatically.
Scan the corresponding host interface quick set command to complete the installation.
Please follow the same procedures to pair the other scanners with the smart cradle.
For user’s convenience, the smart cradle will automatically assign the ID numbers to each scanner. After completed all pairing processes, you can scan the “System Information” command to check the assigned ID number of each scanner.
5
PICO Mode
Wireless FuzzyScan
Getting Started
Clone Function
For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration” command. After that, please take the other paired scanners to scan “Clone” command one by one to clone the host interface related parameters.
Please ensure to keep those paired scanners in connected status when you use the “Clone” function. Because the host
interface related parameters can’t be cloned to the paired scanner in disconnected status.
Save Configuration
The below host interface related parameters will be impacted by clone function:
Data Transmission Parameter Serial Interface Control
Field Delimiter Handshaking Protocol
Data Transmission Format Intermessage Delay
Host Interface Control Interfunction Delay
Host interface Selection Intercharacter Delay
Keyboard Interface Control Baud Rate
Keyboard Layout Data Frame
Intermessage Delay Time Out Control
Interfunction Delay Wand Emulation Control
Intercharacter Delay Output Polarity
Caps Lock Control Initial Signal State
Caps Lock Release Control Margin Time
Function Key Emulation Module Time
Key Pad Emulation Narrow/Wide Ratio
Clone
Upper/Lower Case Code39 Emulation
6
Wireless FuzzyScan
Getting Started
Using FuzzyScan in HID Mode
Ensure the battery is fully charged. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “HID Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds.
Uninstall
Execute the Bluetooth Discovery procedure to find all available Bluetooth devices in your remote host. You will see ‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already.
Double click the “CINO FxxxBT-xxxx” in the discovered Bluetooth device list. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting). You will see “Keyboard on CINO FxxxBT-xxxx”, and double click this HID service to establish the connection between the scanner and the remote host device.
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.
Please note that if the scanner is not connected to the host device within 1 minute after scanning the “HID Mode” command, the scanner will go to sleep automatically. You just need to press the trigger to wake up the scanner to continue the installation.
1. The installation procedures vary on different remote host devices, operation systems and the Bluetooth software driver.
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during
the installation processes.
2. While using HID mode, beware of potential error in the data transmitted at the same time when radio link quality is poor.
You are suggested to use the scanner under the communication coverage all the times.
HID Mode
7
Wireless FuzzyScan
Getting Started
Using FuzzyScan in SPP Mode
Establish SPP Master Connection
Ensure the battery is fully charged. Please go to the folder of “Hardware” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes.
Ensure a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of “Local Services” located in Bluetooth Advanced Setting. Click the “Add Serial Services” to add one more Bluetooth COM port.
Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “SPP Master Mode” command, and the status indicator of scanner will turn steady red.
Uninstall
Scan a 12-character MAC address barcode, or scan 12 option codes and “FIN” command to confirm your inputs. The scanner will give continuous short clicks and the link indicator of the scanner will flash blue quickly during the radio connecting process. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting).
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.
Please note that if the scanner failed to connect to the host device within 30 seconds, the link indicator will give 3 blue blinks per 2 seconds. But the scanner is still continuing to discover the host device for another 30 seconds before go to sleep. In the interim, you still can scan “Uninstall” command to revert the scanner to uninstall state. If the scanner goes to sleep already, you just need to press the trigger to wake up the scanner to continue the installation.
The installation procedures vary on different remote host devices, operating systems and the Bluetooth software driver.
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the
installation processes.
8
SPP Master Mode
Wireless FuzzyScan
Getting Started
Establish SPP Slave Connection
Ensure the battery is fully charged and a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of “Client Applications” located in Bluetooth Advanced Setting. Click the “Add COM Port” to add one more Bluetooth COM port.
Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “SPP Slave Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds.
Uninstall
Execute the Bluetooth Discovery procedure to find all available Bluetooth device list in your remote host. You will see ‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already.
Double click the “CINO FxxxBT-xxxx” on the discovered Bluetooth devices. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting). You will see “Serial Port on CINO FxxxBT-xxxx”, and double click this SPP service to establish the connection between the scanner and the remote host device.
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.
Please note that if the scanner is not connected to the host device within 1 minute, the scanner will go to sleep. You can press the trigger to wake up the scanner to continue the installation.
The installation procedures vary on different remote host devices, operating systems and the Bluetooth software drivers.
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the
installation processes.
SPP Slave Mode
9
Wireless FuzzyScan
Getting Started
Out-of-range Scanning
When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection with the remote host device.
If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of working range. All scanned data will be temporarily stored into the memory buffer until radio link resumed.
Enable Out-of-range Scannning
In case of the scanner is out of working range, you will hear 4 beeps in descending tone to indicate the radio connection lost. The link indicator of scanner will give 3 blue blinks per 2 seconds. Once the scanner is back to working range, you will hear 4 beeps in ascending tone to indicate the radio connection rebuilt and the scanner will give 1 blue blink per 2.5 seconds. At the same time, all stored scanned data will be transmitted automatically right after the radio link is resumed.
Disable Out-of-range Scanning
Presentation Scanning
The Presentation Scanning is designed for hand-free applications for user’s convenience. If the “Presentation Scanning Auto-sense” function is enabled, the scanner is capable of automatically switching to presentation mode when you place it onto the SmartStand or cradle.
Enable Presentation Scanning Auto-sense
Disable Presentation Scanning Auto-sense
Paging Function
The paging function is helpful for you to locate the paired smart cradle or scanner. If you would like to page the paired smart cradle, you can scan “Paging” command. If you would like to page the paired scanner, you can press the paging/rest button of the smart cradle no longer than 3 seconds.
Paging
Paging/Reset Button
10
Wireless FuzzyScan
Getting Started
Batch Scanning (Inventory Mode)
Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000 EAN-13 labels. It is an ideal cost-saving solution for inventory applications.
Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning. You can scan and store the barcode data till the memory storage is full. If the storage is full, you will hear 2 long beeps and the status indicator will give 2 red blinks to indicate out of storage. To terminate the batch scanning, please scan the “Exit Batch Scanning” command.
Enter Batch Scanning
Exit Batching Scanning
How to Transmit Stored Data
The scanner is preset to scan the “Transmit Stored Data” command to transmit all stored data. During the transmission process, the scanner will give continuous short clicks and blue blinks. Then the scanner will give two short beeps after data transmission is completed.
Transmit Stored Data
But you are still able to set the scanner to transmit the stored data by placing the scanner onto the cradle as well.
Transmit Stored Data by Scanning
Barcode Command
Transmit Stored Data by
Placing Scanner onto Cradle
The scanner is preset to keep all the stored data until you scan the “Clear All Stored Data” command. But you are still able to change the setting to “Auto Delete Stored Data after Transmission” as well.
Transmit Stored Data by Scanning Barcode
or Placing Scanner onto Cradle
Clear All Stored Data
11
Wireless FuzzyScan
Getting Started
Auto Delete Stored Data
after Transmission
Keep Stored Data after
Transmission
If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the ‘’Delete Last Scanned Data’’ command, the last stored data can be deleted.
Delete Last Scanned Data
Using Quantity Feature
If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the quantity barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage together with the barcode data.
Quantity 0 Quantity 5
Quantity 3 Quantity 8
Quantity 1 Quantity 6
Quantity 4 Quantity 9
Quantity 2 Quantity 7
There are two ways to output the stored barcode data and quantity information. Please refer to following for details:
Stored data is transmitted as many times as the quantity indicated.
Stored data is transmitted together with quantity information in two fields. Please scan “Enable Quantity Field Transmission” command to enable this function. The preset delimiter is “
“, but you are able to choose your desired one
from FuzzyScan Wireless Reference Manual for details.
Disable Quantity Field Transmission
12
Enable Quantity Field Transmission
Wireless FuzzyS
can
Configure Your FuzzyScan
Bar Code Programming Menu
The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose.
Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the FuzzyScan concurrently.
A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code. As you set the FuzzyScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set FuzzyScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family.
System Command
System Command
System CommandSystem Command
The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations, such as entering programming mode (PROGRAM), exiting programming mode (EXIT), listing system information (SYSLIST), recovering to factory preset configurations (M_DEFAULT), and so on. Please note that all system commands will take a few seconds to complete the operations. User must wait for the completion beeps before scanning another bar code.
Family Code
Family Code
Family CodeFamily Code
The Family Code is scanned to select the user desired programming family. FuzzyScan has already provided more than one hundred programming families to meet any specific requirements.
Option Code
Option Code
Option CodeOption Code
The Option Codes is a set of bar code commands represented by “0–9”, “A–F” and finishing selection (FIN). For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family.
13
Wireless FuzzyS
can
Configure Your FuzzyScan
Programming Procedures
Programming Procedures
Programming ProceduresProgramming Procedures
As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on.
The programming procedures of FuzzyScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure.
If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details. Before setting the FuzzyScan, please also refer to the “Beeping Indications” listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the FuzzyScan.
Conventions of Programming Menu
Conventions of Programming Menu
Conventions of Programming MenuConventions of Programming Menu
Conventions Descriptions

P.C. Programming Category
( ) Necessary Option Code
[ ] Selectable Option Code
Factory Default Value
: Signle scan selection
SS
MS : Multiple scans selection CS : Cycling scan selection DS : Dual level scan selection
14
Wireless FuzzyS
can
Configure Your FuzzyScan
Program & End
Program & End
Program & EndProgram & End
parameters in Flash Memory ASIC or non-volatile memory,
FuzzyScan will enter programming mode,
and inhibit all non-programming functions.
FuzzyScan will exit programming mode, and store all
then issue the completion beeping.
Please note that the FuzzyScan will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END”. Please don’t turn off the power before the completion beeping. It may destroy all configured parameters.
Scan
PROGRAM”
Scan
END
System List, Group & Master Default
System List, Group & Master Default
System List, Group & Master DefaultSystem List, Group & Master Default
FuzzyScan will list the product information and
revision number to host via selected host interface,
then issue the completion beeping.
FuzzyScan will recover all programmable
parameters into factory preset configurations,
then issue the completion beeping.
Scan
SYSLIST”
Scan
M_DEFAULT
15
Wireless FuzzyS
can
Configure Your FuzzyScan
Single scan selection
Single scan selection
Single scan selectionSingle scan selection
One of
One of
Yes
Scan
PROGRAM
Scan
Family
Scan
Option
Repeat
Selection
Scan
END
Codes
Codes
No
Multiple scans selection
Multiple scans selection
Multiple scans selectionMultiple scans selection
Enter programming mode.
Select one of desired
programming families.
Select one option code of
desired parameter.
Want to select another
programming family?
Exit programming mode.
Yes
One of
Several
Scan
PROGRAM”
Scan
Family
Codes
Scan One or
Option
Codes
Repeat
Selection
No
Scan
END
Enter programming mode.
Select one of desired
programming families.
1. Select one or several
option codes to select
desired parameters.
2. If it’s necessary, scan
“FIN” to terminate
option code selection.
Want to select another
programming family?
Exit programming mode.
16
Wireless FuzzyS
can
Configure Your FuzzyScan
Cycling scan selection
Cycling scan selection
Cycling scan selectionCycling scan selection
Yes
One of
One of
Scan
“PROGRAM”
Scan
Family
Codes
Scan
Option
Scan “
Codes
FIN
Repeat
Selection
No
Scan
END
Enter programming mode.
Select one of desired
programming families.
Cycling select one or
several option codes of
desired parameters as
“Single” or “Multiple”
scans selection.
Finish cycling selection.
(If necessary)
Want to select another
programming family?
Exit programming mode.
Dual level selection
Dual level selection
Dual level selectionDual level selection
One of
Several
Several
Yes
Scan
PROGRAM”
Scan
Family
(
) Scan
1st
Option
(
) Scan One or
2nd
Option
Repeat
Selection
Scan
END”
Codes
No
Codes
Codes
Enter programming mode.
Select one of desired
programming families.
Select several option codes
of desired parameters.
1. Select one or several
option codes of desired
parameters.
2. If it’s necessary, scan
“FIN” to terminate
option code selection.
Want to select another
programming family?
Exit programming mode.
17
Wireless FuzzyS
can
Configure Your FuzzyScan
Host Interface Selection
PROGRAM
Family Code Selection P.C
Host Interface Selection
MS MS MS MS MS MS MS MS MS MS
Parameter Selection Option Code
IBM PS/2, 25-30 series keyboard wedge interface Standard/TTL RS-232 peer-to-peer serial Wand emulation USB Com Port Emulation PS/2 (DOS/V) direct link (keyboard replacement) PS/2 (DOS/V) keyboard wedge turbo mode PS/2 (DOS/V) keyboard wedge standard mode Laser emulation USB HID standard mode  USB HID turbo mode
F_DEFAULT
02 06 08 09 10 13 14 17 18 19
18
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Symbol ID : 1 character
DS Code 128 (default=B)
♦♦♦♦ User Defined Symbol ID ♦♦♦♦
Parameter Selection Option Code 2nd Option Code
UCC/EAN-128 (default=C) UPC-A (default=A) EAN-13 (default=F) Codabar/NW-7 (default=D) Code 39/Code 32 (default=G) Code 93 (default=H) Standard/Industrial 2 of 5 (default=I) Interleaved 2 of 5 (default=J) Matrix 2 of 5 (default=K) China Postal Code (default=L) German Postal Code (default=M) IATA (default=O) Code 11 (default=P) MSI/Plessey (default=R) UK/Plessey (default=S) Telepen (default=T) GS1 DataBar (default=X) UPC-E (default=E) EAN-8 (default=N) Trioptic Code 39 (Default=W) UCC Coupon Extended Code (Default=Z) PDF417/Micro PDF417 (default=V) Codablock F (default=Y) Korea Post Code (default =a)
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 26
F_DEFAULT
(1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character)
19
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Symbology ID Transmission
♦♦♦♦ Symbology ID Transmission ♦♦♦♦
Parameter Selection Option Code
SS
Disable symbology ID transmission
SS
Enable prefix CINO symbology ID transmission
SS
Enable suffix CINO symbology ID transmission
SS
Enable both prefix and suffix CINO symbology ID transmission
SS
Enable prefix AIM symbology ID transmission
SS
Enable suffix AIM symbology ID transmission
SS
Enable both prefix and suffix AIM symbology ID transmission
F_DEFAULT
0 1 2 3 4 5 6
20
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Readable Symbology Setting
Remember to scan “FIN” to terminate
this selection. But if you select the
“ Auto ”, FuzzyScan will terminate this
selection automatically.
SS
CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS
Auto Code 128 * UPC-A * UPC-E * EAN-13 * EAN-8 * Codabar/NW-7 * Code 39 * Trioptic Code 39 Standard/Industrial 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 * China Postal Code German Postal Code Code 93 * Code 11 MSI/Plessey UK/Plessey Telepen GS1 DataBar (RSS-14) * IATA PDF417/Micro PDF417 Codablock F Korea Post Code
♦♦♦♦ Readable Bar Code Setting ♦♦♦♦
F_DEFAULT
Parameter Selection Option Code
00 01 02 03 04 05 06 07 47 08 38 48 58 68 09 10 11 12 13 14 15 17 18 21
If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.
Above symbologies marketed with * are enable as default. When you select “Auto”, the scanner only read those symbologies marked with *
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.
21
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Code 39 Family Setting
Trioptic Code 39 Setting
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS
Code 39/Code 32 Setting
♦♦
♦♦♦
Parameter Selection Option Code
Disable Code 39 Enable Code 39 Select Standard Code 39 as primary format  Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission  Enable start/stop symbol transmission Disable Code 32 leading A transmission  Enable Code 32 leading A transmission Disable MOD 43 check digit verification  Enable MOD 43 check digit verification Disable check digit transmission  Enable check digit transmission Disable Code 39 buffering  Enable Code 39 buffering
Disable Trioptic Code 39 Enable Trioptic Code 39
F_DEFAULT
0 1 2 3 4 5 6 7 8 9 A
B C D E
0
1
SS
Code 39 Min. Length
Code 39 Max. Length
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
Default (01)
MS
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
SS
Default (98)
MS
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
FIN
(2 digits)
22
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Codabar Setting
Codabar Min. Length
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
MS
♦♦♦♦ Codabar/NW-7 Setting ♦♦♦♦
Parameter Selection Option Code
Disable Codabar Enable Codabar  Select Codabar standard format  Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission  Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification  Enable check digit verification Disable check digit transmission  Enable check digit transmission
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
0
1
2
3
4
5
6
7
8
9 A B C D E
FIN
(2 digits)
Codabar Max. Length
SS
Default (98)
MS
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
23
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
SS
UPC Family Setting
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric system, UPC-A check digit transmission.
UPC-E & EAN-8 Expansion : Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
UPC-A/E Standardization : Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.
UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option.
WPC Selection
(UPC/EAN/CAN)
UPC-A 12 - 1 - 1 + 2 + 5 + 1 0 UPC-E 8 - 1 - 1 + 2 + 5 + 1 + 4 EAN-13 13 - 1 NC + 2 + 5 NC 0 EAN-8 8 - 1 NC + 2 + 5 NC + 5
Basic Length
Disable UPC-A
SS
Enable UPC-A 
SS
Disable UPC-E
SS
Enable UPC-E 
SS
Disable UPC-E expansion
SS
Enable UPC-E expansion
SS
Disable UPC standardization
SS
Enable UPC standardization
SS
Disable UPC numeric system
SS
Enable UPC numeric system
SS
Disable UPC-A check digit transmission
SS
Enable UPC-A check digit transmission
SS
Disable UPC-E check digit transmission
SS
Enable UPC-E check digit transmission
SS
Disable UPC “leading 1” portion
SS
Enable UPC “leading 1” portion
Disable
Check Digit
♦♦♦♦ UPC-A & UPC-E Setting ♦♦♦♦
Parameter Selection Option Code
Disable
Numeric System
With 2-digit
Addendum
With 5-digit
Addendum
Enable
Standardization
F_DEFAULT
0
1
2
3
4
5
6
7
8
9 A B C D E F
Enable
Expansion
24
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
UPC Supplement Setting
UPC/EAN Security Level
Supplement Scan Voting
SS SS SS SS SS SS SS SS
SS SS
SS
SS SS SS SS SS SS SS
♦♦♦♦ UPC-A & UPC-E Setting ♦♦♦♦
Parameter Selection Option Code
Select UPC without supplement digits Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separator On
Level 0 Level 1  Level 2
Only available for UPC-A & EAN-13
None Level 1 Level 2
Level 3 Level 4 Level 5 Level 6
Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13
F_DEFAULT
0
1
2
3
4
5
6
7
0
1
2
0 1 2 3 4 5 6
7 8 9 A B C D
UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes. Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels.
security level may significantly impair the decoding ability of the scanner.
increase the misread.
25
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
EAN Setting
EAN Supplement Setting
SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS
♦♦♦♦ EAN Setting ♦♦♦♦
Parameter Selection Option Code
Disable EAN-13 Enable EAN-13  Disable EAN-8 Enable EAN-8  Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN-13 check digit transmission Enable EAN-13 check digit transmission Disable EAN-8 check digit transmission Enable EAN-8 check digit transmission Disable ISBN/ISSN Conversion reading check Enable ISBN/ISSN Conversion reading check
Select EAN without supplement digits Select EAN with only 2 supplement digits Select EAN with only 5 supplement digits Select EAN with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN Addenda Separator Off EAN Addenda Separator On
F_DEFAULT
0
1
2
3
4
5
6
7
8
9 A B
0
1
2
3
4
5
6
7
SS SS SS SS SS SS SS
None Level 1 Level 2 Level 3 Level 4 Level 5 Level 6
Supplement Scan Voting
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels.
26
Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13
0 1 2 3 4 5 6
7 8
9 A B C D
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
SS
UPC/EAN Security Level
EAN Supplement Control
UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes. Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may
EAN Supplement Control
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement
digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted. If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5 supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.
security level may significantly impair the decoding ability of the scanner.
increase the misread.
Level 0
SS
Level 1  Level 2
SS
Only available for UPC-A & EAN-13
SS
Disable all specific prefix supplement digital output 
SS
Enable all specific prefix supplement digital output
SS
Enable 491 Supplement Digit Output
SS
Enable 978/979 Supplement Digit Output
SS
Enable 977 Supplement Digit Output
SS
Enable 378/379 Supplement Digit Output
SS
Enable 414/419 Supplement Digit Output
SS
Enable 434/439 Supplement Digit Output
♦♦♦♦ EAN Setting ♦♦♦♦
F_DEFAULT
Parameter Selection Option Code
0 1
2
0 1 2 3 4 5 6 7
27
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
UCC Coupon Extended Code
UCC Coupon Extended Code When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and UCC/EAN-128 Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.
SS SS
♦♦♦♦ UCC Coupon Extended Code Setting ♦♦♦♦
Parameter Selection Option Code
Disable UCC Coupon Extended Code  Enable UCC Coupon Extended Code
F_DEFAULT
0 1
28
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
IATA Setting
Interleaved 2 of 5 Setting
SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS
♦♦♦♦ IATA & Interleaved 2 of 5 Setting ♦♦♦♦
Parameter Selection Option Code
Disable IATA  Enable IATA Select 15-digit fixed length IATA checking  Select variable length IATA Disable check digit verification  Enable check digit automatic verification Enable S/N checking digit verification only Enable CPN checking digit verification only Enable CPN, Airline and S/N check digit verification Disable check digit transmission  Enable check digit transmission Disable start/stop symbol transmission Enable start/stop symbol transmission
Disable Interleaved 2 of 5 Enable Interleaved 2 of 5  Select Interleaved 2 of 5 as primary format  Select German Postal Code as primary format No check character  Validate USS check digit Validate OPCC check digit Disable check digit transmission  Enable check digit transmission
F_DEFAULT
0 1 2 3 4 5 6 7 8
9 A B C
0
1
2
3
4
5
6
7
8
29
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Code 25 Setting
Code 25 Family Min. Length
Code 25 Family Max. Length
SS SS SS SS SS SS SS SS SS SS
SS
MS
SS
MS
♦♦♦♦ Code 25 Family Setting ♦♦♦♦
Parameter Selection Option Code
Disable Standard/Industrial 2 of 5  Enable Standard/Industrial 2 of 5 Disable Matrix 2 of 5  Enable Matrix 2 of 5 Disable China Postal Code  Enable China Postal Code Disable check digit verification Enable check digit verification Disable check digit transmission  Enable check digit transmission
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
0
1
2
3
4
5
6
7
8
9
FIN
(2 digits)
FIN
(2 digits)
For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length. To decode all types of Code 25 or to variable length of Code 25 will increase the possibility of reading error.
30
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Code 11 Setting
Code 11 Min. Length
SS SS SS SS SS SS SS
SS
MS
Code 11 Max. Length
SS
MS
Code 93 Setting
SS SS SS SS
♦♦♦♦ Code 11 & Code 93 Setting ♦♦♦♦
Parameter Selection Option Code
Disable Code 11  Enable Code 11 Disable check digit verification  Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Disable Code 93 Enable Code 93  Disable check digit transmission  Enable check digit transmission
F_DEFAULT
0
1
2
3
4
5
6
FIN
(2 digits)
FIN
(2 digits)
0
1
2
3
SS
Code 93 Min. Length
Code 93 Max. Length
Default (01)
MS
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
SS
Default (98)
MS
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
FIN
(2 digits)
31
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
MSI/Plessey Setting
MSI/Plessey Min. Length
MSI/Plessey Max. Length
SS SS SS SS SS SS SS
SS
MS
SS
MS
♦♦♦♦ MSI/Plessey Setting ♦♦♦♦
Parameter Selection Option Code
Disable MSI/Plessy  Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission  Enable check digit transmission
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
0
1
2
3
4
5
6
FIN
(2 digits)
FIN
(2 digits)
32
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Code 128/EAN-128 Setting
Code 128/EAN-128 Min. Length
Code 128/EAN-128 Max. Length
♦♦♦♦ Code 128 & UCC/EAN 128 Setting ♦♦♦♦
Parameter Selection Option Code
SS
Disable Code 128 and UCC/EAN-128
SS
Enable Code 128 and UCC/EAN-128 
SS
Disable function code conversion
SS
Enable function code conversion
SS
ISBT Concatenation Off 
SS
ISBT Concatenation On
SS
Default (01)
MS
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
SS
Default (98)
MS
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
0
1
2
3
4
5
FIN
(2 digits)
FIN
(2 digits)
33
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
UK/Plessey Setting
UK/Plessey Min. Length
UK/Plessey Max. Length
SS SS SS SS SS SS SS SS
SS
MS
SS
MS
♦♦♦♦ UK/Plessey Setting ♦♦♦♦
Parameter Selection Option Code
Disable UK/Plessey  Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
0
1
2
3
4
5
6
7
FIN
(2 digits)
FIN
(2 digits)
34
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Telepen Setting
Telepen Min. Length
Telepen Max. Length
SS SS SS SS SS SS
SS
MS
SS
MS
♦♦♦♦ Telepen Setting ♦♦♦♦
Parameter Selection Option Code
Disable Telepen  Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission
Default (04) 01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98) 98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
0
1
2
3
4
5
FIN
(2 digits)
FIN
(2 digits)
35
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
GS1 DataBar Setting
GS1 DataBar Min. Length
GS1 DataBar Max. Length
SS SS SS SS SS SS
SS
MS
SS
MS
♦♦♦♦ GS1 DataBar Setting ♦♦♦♦
Parameter Selection Option Code
Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14)  Disable GS1 DataBar Limited Enable GS1 DataBar Limited  Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded 
Default (04) 01-Maximum
Only available for Expanded GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (74) 74-Minimum
Only available for Expanded GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
0
1
2
3
4
5
FIN
(2 digits)
FIN
(2 digits)
36
Wireless FuzzyS
can
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection P.C
Composite Codes Setting
PDF417/MicroPDF417 Setting
Codablock F Setting
Korea Post Code Setting
♦♦♦♦ Linear-stacked & Korea Post Code Setting ♦♦♦♦
Parameter Selection Option Code
SS
Disable composite codes 
SS
Enable composite codes
SS
UPC Composite Mode: UPC never linked 
SS
UPC Composite Mode: UPC always linked
SS
Disable PDF417
SS
Enable PDF417 
SS
Disable MicroPDF417 
SS
Enable MicroPDF417
SS
Disable 
SS
Enable
SS
Disable 
SS
Enable
Length fixed in 6 characters.
F_DEFAULT
0
1
2
3
0
1
2
3
0
1
0
1
Composite Codes Setting If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected. If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.
37
Wireless FuzzyS
can
Configure Your FuzzyScan
Keyboard Interface Control
PROGRAM
Family Code Selection P.C
Keyboard Layout
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
♦♦♦♦ Keyboard Layout (Language) Setting ♦♦♦♦
Parameter Selection Option Code
USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (Spanish, QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Spain (Latin America, QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany (QWERTY) Iceland (QWERTY) Japan (DOS/V) Czech (QWERTY)
F_DEFAULT
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17
Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or postamble.
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.
Keyboard Interface Message String :
Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix
1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character
38
Wireless FuzzyS
can
Configure Your FuzzyScan
Keyboard Interface Control
PROGRAM
Family Code Selection P.C
Record Suffix
Preamble
SS SS SS SS SS SS
SS
MS
Postamble
SS
MS
Caps Lock Control
SS SS SS
♦♦♦♦ Record Suffix, Preamble, Postamble & Caps Lock ♦♦♦♦
Parameter Selection Option Code
None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character)
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
“Caps Lock Off” State “Caps Lock On” State Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
F_DEFAULT
0
1
2
3
4
5, (00-7F)
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
0
1
2
Caps Lock Release Control
“Caps Lock On, Caps Off” 
SS
“Caps Lock On, Shift Off”
0
1
SS
The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions for you.
Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch.
39
Wireless FuzzyS
can
Configure Your FuzzyScan
Keyboard Interface Control
PROGRAM
Family Code Selection P.C
Intermessage Delay
Intercharacter Delay
Interfunction Delay
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters.
Interfunction Delay is a time delay between the transmission of each segment of the message string.
Intermessage Delay, Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes.
SS
MS
SS
MS
SS
MS
None 1-99 (x10) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
♦♦♦♦ Delay Setting ♦♦♦♦
F_DEFAULT
Parameter Selection Option Code
FIN
(2 digits)
FIN
(2 digits)
FIN
(2 digits)
40
Wireless FuzzyS
can
Configure Your FuzzyScan
Keyboard Interface Control
PROGRAM
Family Code Selection P.C
Function Key Emulation
Key Pad Emulation
Upper/Lower Case
SS SS
SS SS
SS SS SS SS
♦♦♦♦ Emulation Setting & Upper/Lower Case Setting ♦♦♦♦
Parameter Selection Option Code
Enable ASCII 00-31 code as keyboard function code output Ctrl-Output
Refer to Appendix – Keyboard Function Code Table for details.
Disable key pad emulation Enable numeric output as key pad (Num Lock On) output
Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case)
F_DEFAULT
0
1
0
1
0
1
2
3
41
Wireless FuzzyS
can
Configure Your FuzzyScan
Serial Interface Control
PROGRAM
Family Code Selection P.C
STX/ETX Control
SS SS
Record Suffix
Preamble
SS SS SS SS SS SS
MS
SS
MS
Postamble
SS
MS
♦♦♦♦ Record Suffix, Preamble ,Postamble Setting ♦♦♦♦
Parameter Selection Option Code
Disable STX/ETX transmission Enable STX/ETX transmission
STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
None CR (0DH) LF (0AH) CRLF (0D0AH) TAB (09H) SPACE (20H) User defined character (1 character)
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
None 1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
F_DEFAULT
0
1
0
1
2
3
4
5
6, (00-7F)
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
Serial Interface Message String (RS232, USB COM) :
STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID
1 character
1-15 characters
2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters
Postamble ETX Record Suffix
1 character 1 character
42
Wireless FuzzyS
can
Configure Your FuzzyScan
Serial Interface Control
PROGRAM
Family Code Selection P.C
Intermessage Delay
Intercharacter Delay
Interfunction Delay
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters.
Interfunction Delay is a time delay between the transmission of each segment of the message string.
Intermessage Delay, Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes.
SS
MS
SS
MS
SS
MS
None 1-99 (x10) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
None 1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
♦♦♦♦ Delay Setting ♦♦♦♦
F_DEFAULT
Parameter Selection Option Code
FIN
(2 digits)
FIN
(2 digits)
FIN
(2 digits)
43
Wireless FuzzyS
can
Configure Your FuzzyScan
Serial Interface Control
♦♦♦♦ Protocol, Baud Rate, Data Frame & Time Out Setting ♦♦♦♦
PROGRAM
Family Code Selection P.C
Handshaking Protocol
Baud Rate (BPS)
Data Frame
Serial Response Time-out
SS SS SS SS
SS SS SS SS
SS SS SS SS SS SS SS SS
SS SS SS
MS
Parameter Selection Option Code
None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking)
38.4K BPS
19.2K BPS 9600 BPS 4800 BPS
8, None, 1 8, Odd, 1 8, Even, 1 8, Space, 1 8, Mark, 1 8, None, 2 7, Odd, 1 7, Even, 1
None 200 mseconds 500 mseconds
2400 BPS 1200 BPS
57.6K BPS
115.2K BPS
7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2
1 second 2 seconds 5 seconds User defined value (seconds)
F_DEFAULT
0
1
2
3
0 1 2 3
0 1 2 3 4 5 6 7
0 1 2
6, (2 digits)
4 5 6 7
8 9 A B C D E
3 4 5
When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication.
When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.
44
Wireless FuzzyS
can
Configure Your FuzzyScan
Wand/Laser Emulation Control
♦♦♦♦ Output Polarity, Signal State, Margin/Module Time, etc. ♦♦♦♦
PROGRAM
Family Code Selection P.C
Output Polarity
SS SS
Initial Signal State
SS SS
Margin Time
Module Time
SS SS SS SS
SS SS SS
Parameter Selection Option Code
High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space)
Determine the output voltage level for both bar and space.
High Level (5Vdc) Low Level (0Vdc)
Determine the initial state of output voltage level.
10 msec. 15 msec. 20 msec. 25 msec.
Extremely short Short Medium 
30 msec. 50 msec. 100 msec. Delay time before data transmission
Long
Time base of minimum narrow bar
F_DEFAULT
0
1
0
1
0 1 2 3
0 1 2
4 5 6
3
Narrow/Wide Ratio
Code 39/Code 128 Emulation
[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read,
they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.
[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.
SS SS SS
SS SS SS SS SS
1:2 1:2.5 1:3
Disable standard Code 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation Enable Full ASCII Code 39 emulation Enable Code 128 emulation
45
0
1
2
0
1
2
3
4
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
SS
Operation Mode
Trigger Mode (Low Power Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the
scanner before scanning the bar code.
Presentation Mode (Auto Detection) Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is
similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “ Presentation Sensitivity”).
Trigger mode
SS
Presentation mode
♦♦♦♦ Operation Mode ♦♦♦♦
Parameter Selection Option Code
F_DEFAULT
1
2
46
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
Buzzer Tone Adjust
Power On Indicator
Good Read Indicator
SS SS SS SS SS SS SS
SS SS SS
SS SS
Vibrator Control
SS SS
♦♦♦♦ Buzzer, Indicator, Vibrator, Inverse Reading ♦♦♦♦
Parameter Selection Option Code
Buzzer tone – mute Buzzer tone – low Buzzer tone – medium Buzzer tone – high Buzzer tone - extremely high Power-on beep No power-on beep
Disable (LED off) LED steady on LED flash
Disable Enable 
Disable Enable 
Optional function, only available for vibrator model.
F_DEFAULT
0
1
2
3
4
5
6
0
1
2
0
1
0
1
Inverse Reading
SS
Disable  Enable
0
1
SS
SS
Beeping Control
Radio Connected/ Disconnected Beep On 
SS
Radio Connected/ Disconnected Beep Off
SS
Battery Power Low Beep On 
SS
Battery Power Low Beep Off
47
0
1
2
3
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
Dollar Sign Control
Redundancy
Scan Rate Control
♦♦♦♦ Dollar Sign Control, Redundancy, Scan Rate Control ♦♦♦♦
Parameter Selection Option Code
SS
Dollar sign output as “ $ “ 
SS
Dollar sign output as “
SS
Dollar sign output as “ € “
SS
Dollar sign output as “ £ “
SS
Dollar sign output as “ ¢ “
SS
None SS SS SS SS SS
SS SS
Level 1
Level 2
Level 3
Level 4
Level 5
To prevent potential miss reading.
Dynamic 
Fixed
F_DEFAULT
0 1 2 3 4
0 1 2 3 4 5
0 1
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.
Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on
the move. But this may impact to the reading distance.
48
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
SS
Reread Delay
(Double Scan Verification)
Good Read Delay
The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the same bar code twice.
This Good Read Delay is the minimum amount of time before the scanner can read another bar code.
Disable SS
Immediate time out  SS
Short time out SS
Medium time out SS
Long time out SS
Force verification
SS
None  SS
200 msec. SS
500 msec. SS
1 sec. SS
1.5 sec.
SS
2 sec. SS
3 sec.
♦♦♦♦ Delay Setting ♦♦♦♦
F_DEFAULT
Parameter Selection Option Code
0 1 2 3 4 5
0 1 2 3 4 5 6
49
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
Light Source On Time
Hands Free Time-out
Good Read Duration
Time Delay to Low Power Trigger
The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.
The Presentation Mode is referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any trigger operation), the imager will revert to the original hands free mode.
The Time Delay to Low Power Trigger sets the time for scanner to enter low power trigger mode after any scanning activity.
SS SS SS SS
SS SS SS SS SS
SS SS SS SS SS
SS SS SS SS SS SS
♦♦♦♦ Time-out Setting, Good Read Duration ♦♦♦♦
Parameter Selection Option Code
Short 
Medium
Long
Extremely long
Short 
Medium
Long
Extremely long
Disable
Short
Medium 
Long
Extremely long
Extremely short
1 sec
3 secs
5 secs
7 secs
9 secs
Immediate 
F_DEFAULT
0 1 2 3
0 1 2 3 4
0 1 2 3 4
0 1 2 3 4 5
50
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
SS
SmartStand Power Off Timeout
Presentation Auto-sense
Presentation Sensitivity
The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be off when the pre-defined duration is up.
When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the SmartStand or cradle
The Presentation Sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting
the barcode.
3 mins  SS
5 mins SS
10 mins
Only available for FuuzzyScan Laser model
SS
Disable  SS
Enable
SS
Level 1 SS
Level 2 SS
Level 3 SS
Level 4 SS
Level 5 
♦♦♦♦ Presentation Scanning Setting ♦♦♦♦
Parameter Selection Option Code
Level 6 Level 7
F_DEFAULT
0 1 2
0 1
0 1 2 3 4
5 6
51
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
Out-of-range Scanning
Link Supervision Time-out
Sleep Time-out of Connect State
♦♦♦♦ Out-of-range Scanning, Sleep Time-out Control ♦♦♦♦
Parameter Selection Option Code
SS
Disable  SS
Enable
SS
1 sec SS SS SS SS
SS
MS
3 secs
5 secs
7 secs
9 secs
Only available in PAIR & PICO modes
6 (x5) minutes 
0-99 (x5) minutes
If you don’t want the scanner to enter sleep mode, please set time-out to “0
F_DEFAULT
0 1
0 1 2 3 4
FIN
(2 digits)
SS
Sleep Time-out of Disconnect State
Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to continue scanning barcode data into memory buffer until radio link resumed.
The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds.
The Sleep Time-out Control can be set under radio connection or disconnection state. If the scanner is not used within the preset time-out duration, it will automatically enter “Sleep State” for power saving purpose. You are able to disable this function by setting the time-out duration to “0”.
1 minute 
MS
0-99 minutes
If you don’t want the scanner to enter sleep mode, please set time-out to “0
52
FIN
(2 digits)
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
SS
Batch Scanning Link Control
Stored Data Transmission
Delete Stored Data after
Transmission
The Batch Scanning Link Control is a pre-defined radio option to control the radio-on or radio-off status under batch scanning operation. Please note that if the radio disable is activated, the radio link will be disconnected once you enter batching scanning. The radio link will be resumed when you transmit the stored data or exit batch scanning.
The Stored Data Transmission is a pre-defined approach when you want to transmit the scanned data under batch scanning operation. You can transmit the scanned data by placing the scanner onto the cradle or scanning “Transmit Stored Data” command, or by either one of both methods.
In batching scanning, the default setting of Delete Stored Data after Transmission is disable. The scanner will keep all stored data after transmission until you scan the “Clear All Stored Data” command. You are also able to delete all stored data after transmission automatically by enabling this function.
Radio disable SS
Radio enable 
SS
All SS
On cradle SS
Scan barcode 
SS
Disable  SS
Enable
♦♦♦♦ Batch Scanning Setting ♦♦♦♦
F_DEFAULT
Parameter Selection Option Code
0 1
0 1 2
0 1
53
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
Field Delimiter
Batch Data Quantity Output Format
Data Transmission Format
The Field Delimiter is used to separate the specific information and scanned data into two fields. You can choose desired delimiter format.
The Batch Data Quantity Output Format If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the quantity barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage together with the barcode data. There are three ways to output the stored barcode data and quantity information.
In PICO mode, up to 7 scanners can be connected with one smart cradle. The Data Transmission Format can help user to identify the source of the transmitted data. You can choose to transmit the scanned data leading with MAC address or pre-assigned ID. Example format: <MAC address><Field Delimiter><Data> or <ID><Field Delimiter><Data>.
♦♦♦♦ Batch Scanning Data Transmission Setting ♦♦♦♦
Parameter Selection Option Code
SS SS SS SS SS SS
SS SS SS
SS SS SS
None
SPACE
User define
As many times as the quantity indicates 
<Quantity><Field Delimiter><Scanned Data>
<Scanned Data><Field Delimiter><Quantity>
Disable (scanned data only) 
Leading with MAC address (MAC address and scanned data)
Leading with ID No. (scanner ID and scanned data)
Only available for RS232, USB HID and USB COM interface in PAIR & PICO modes
F_DEFAULT
0 1 2 3 4
5, [00-7F]
0 1 2
0 1 2
54
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
Bluetooth Device Name
Bluetooth PIN Code
Bluetooth Authentication
The default Bluetooth Device Name is “CINO FxxxBT-xxxx”, you will be able to change the device name by scanning HEX values (1-16 characters).
The default Bluetooth PIN Code is “00000000”, you will be able to change the PIN Code by scanning HEX values (1-8 numbers).
The Bluetooth Authentication You can enable or disable the Bluetooth Authentication between the scanner and remote host device. If this function is enabled, when the scanner wants to connect itself and sends the data to the host device, the host device has to return a link key shared between the scanner and the host device.
SS
MS
SS
MS
SS SS
♦♦♦♦ Bluetooth Device Name & Security Setting♦♦♦♦
Parameter Selection Option Code
Default device name
User define, 1-16 characters
Default Bluetooth PIN Code
User define, 1-8 numbers
Disable
Enable 
F_DEFAULT
FIN
[00-7F], FIN
FIN
[30-39], FIN
0 1
55
Wireless FuzzyS
can
Configure Your FuzzyScan
Operation Control
PROGRAM
Family Code Selection P.C
SS SS
SS SS
Disable
Enable 
Disable 
Enable
HID Link Quality Setting
Bluetooth Power Saving Mode
The HID Link Quality Setting While using the HID radio link mode, some errors may occur during the data transmission when the radio link is disconnected. You can
enable this function to prevent such error from occurring.
The Bluetooth Power Saving Mode Bluetooth module will enter low consumption mode when you enable this function.
♦♦♦♦ Bluetooth Other Settings ♦♦♦♦
Parameter Selection Option Code
F_DEFAULT
0 1
0 1
56
Wireless FuzzyS
can
Configure Your FuzzyScan
Condensed DataWizard
PROGRAM
Family Code Selection P.C
Preamble
Postamble
Data Length Transmission
Symbology ID Transmission
DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help you to arrange the transmission of scanned data to any specific format without software modification.
Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT/2000/XP environment.
A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.
♦♦♦♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦♦♦♦
Parameter Selection Option Code
SS
MS
SS
MS
SS SS
SS SS SS SS SS SS SS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
Disable
Enable 2 digits data length transmission
If data length exceeds 99, 3-digit data length will be transmitted.
Disable symbology ID transmission
Enable prefix symbology ID transmission
Enable suffix symbology ID transmission
Enable both prefix and suffix symbology ID transmission
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Enable both prefix and suffix AIM symbology ID transmission
F_DEFAULT
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
0 1
0 1 2 3 4 5 6
57
Wireless FuzzyS
can
Configure Your FuzzyScan
Condensed DataWizard
PROGRAM
Family Code Selection P.C
Formatter Control
1st Insertion
SS
MS MS
SS
DS
2nd Insertion
SS
DS
3rd Insertion
SS
DS
♦♦♦♦ Data Formatter Setting ♦♦♦♦
Parameter Selection Option Code
Disable Select one bar code symbology Select all bar code symbologies
Disable Enable
2-digits identified position; max. 3 insertion characters
Disable Enable
2-digits identified position; max. 3 insertion characters
Disable Enable
2-digits identified position; max. 3 insertion characters
FIN
(2 digits)
00
FIN
(2 digits)
position
FIN
(2 digits)
position
FIN
(2 digits)
position
F_DEFAULT
2nd Option Code
automatic termination automatic termination
[1-3 characters], [FIN]
[1-3 characters], [FIN]
[1-3 characters], [FIN]
4th Insertion
SS
DS
The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.
While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbolology ID or Record Suffix. All of the above programmable parameters perform the same function depending on your setting.
Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 60 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
Disable Enable
2-digits identified position; max. 3 insertion characters
58
FIN
(2 digits)
position
[1-3 characters], [FIN]
Wireless FuzzyS
can
Configure Your FuzzyScan
Condensed DataWizard
PROGRAM
Family Code Selection P.C
Verifier Control
Identified Data Length
SS
MS MS
SS
MS
1st Identified Character
SS
DS
2nd Identified Character
SS
DS
♦♦♦♦ Data Verifier Setting ♦♦♦♦
Parameter Selection Option Code
Disable Select one bar code symbology Select all bar code symbologies
Disable Enable
Determine the identified data length for verification.
Disable Enable
2-digits checking position; 1 identified character
Disable Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
00
FIN
(2 digits)
FIN
(2 digits)
position
FIN
(2 digits)
position
F_DEFAULT
2nd Option Code
automatic termination automatic termination
[00-7F]
[00-7F]
3rd Identified Character
SS
DS
The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.
All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.
The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 60 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
Disable Enable
2-digits checking position; 1 identified character
59
FIN
(2 digits)
position
[00-7F]
Wireless FuzzyS
can
Configure Your FuzzyScan
Condensed DataWizard
PROGRAM
Family Code Selection P.C
Replacer Control
1st Replacement
SS
MS MS
SS
DS
2nd Replacement
SS
DS
3rd Replacement
SS
DS
♦♦♦♦ Data Replacer Setting ♦♦♦♦
Parameter Selection Option Code
Disable Select one bar code symbology Select all bar code symbologies
Disable Enable
2-digits identified position; 1 replacement character
Disable Enable
2-digits identified position; 1 replacement character
Disable Enable
2-digits identified position; 1 replacement character
FIN
(2 digits)
00
FIN
(2 digits)
position
FIN
(2 digits)
position
FIN
(2 digits)
position
F_DEFAULT
2nd Option Code
automatic termination automatic termination
[00-7F]
[00-7F]
[00-7F]
The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replcement in the identified position.
All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 60 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find mathced HEX value.
60
Wireless FuzzyS
can
Configure Your FuzzyScan
Condensed DataWizard
PROGRAM
Family Code Selection P.C
Organizer Control
1st Organization
SS
MS MS
SS
DS
2nd Organization
SS
DS
Include/Exclude Control
SS
DS
♦♦♦♦ Data Organizer Setting ♦♦♦♦
Parameter Selection Option Code
Disable Select one bar code symbology Select all bar code symbologies
Disable Enable
2-digits identified position; Forward/backward data transmission setting
Disable Enable
2-digits identified position; Forward/backward data transmission setting
Transmitted data excluded the data of identified position Transmitted data included the data of identified position
FIN
(2 digits)
00
FIN
(2 digits)
position
direction
FIN
(2 digits)
position
direction
0 1
F_DEFAULT
2nd Option Code
automatic termination automatic termination
0 (Forward) 1 (Backward)
0 (Forward) 1 (Backward)
The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in page 60 for details.
While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 60 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table.
61
Wireless FuzzyS
can
Configure Your FuzzyScan
Select a Bar Code Symbology
Select a Bar Code Symbology
Select a Bar Code SymbologySelect a Bar Code Symbology
You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Code 128 : 01 UCC/EAN 128 : 31 UPC-A : 02 UPC-A with 2 supple.: 32 UPC-A with 5 supple.: 42 UPC-E : 03 UPC-E with 2 supple.: 33 UPC-E with 5 supple.: 43 EAN-13 : 04 EAN-13 with 2 supple. : 34 EAN-13 with 5 supple. : 44
EAN-8 : 05 EAN-8 with 2 supple : 35 EAN-8 with 5 supple.: 45 Codabar/NW-7 : 06 Code 39 : 07 Code 32 : 37 Trioptic Code 39: 47 Matrix 2 of 5 : 38 Interleaved 2 of 5 : 48 China Postal Code : 58 German Postal Code : 68
Code 93 : 09 Code 11 : 10 MSI/Plessey : 11 UK/Plessey : 12 Telepen : 13 GS1 Data Bar : 14 IATA : 15 Coupon Code : 16 PDF417/MicroPDF417: 22 Codablock: 23 Korea Post Code: 26
[Data Verifier, Data Replacer, Data Organizer]
If there is a 11-character data string, please refer to the following to calculate the actual position for identification.
X X X X X X X X X X X
00 01 02 03 04 05 06 07 08 09 10
Application Example
Application Example
Application ExampleApplication Example
If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification:
Apply only Interleaved 2 of 5 to the condensed
DataWizard.
Check bar code is actually with 16-digit length.
Allow bar code output whose date code is leading with
“9”.
Position Calculation
Position Calculation
Position CalculationPosition Calculation
[Data Formatter]
If there is a 5-character input data string, refer to the following to calculate the actual position for insertion:
X
00 01 02 03 04 05
X
X
X
X
Three outputs with “TAB” suffix.
The date code output should skip “9” and replaced it by
“A”.
The serial number output should be led with “SN”.
The unit price output should be skipped the first 2
digits.
Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6
Actual Output : A81025[TAB]SN123456[TAB]76[TAB]
62
Wireless FuzzyS
can
Configure Your FuzzyScan
Programming Procedure
Programming Procedure
Programming ProcedureProgramming Procedure
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to “48
(Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to “16”.
Scan “1st Identified Character” and set the identified
position to “00”, then set the identified character to “39” (Hex Code of 9).
[Data Formatter]
Scan “Formatter Control” and set bar code symbology to
48”.
Scan 1st Insertion” and set the identified position to “06”,
then inserted characters to “09” (Hex Code of TAB), “53” (Hex Code of S), “4E” (Hex Code of N).
[Data Replacer]
Scan “Replacer Control” and set bar code symbology
to “48”.
Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology
to “48”.
Scan “1st Organization” and set the identified position
to “16”, then set the data transmission to “0” (forward).
Scan “2nd Organization” and set the identified position
to “17”, then set the data transmission to “1” (backward).
Scan “2nd Insertion” and set the identified position to “12”,
then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection.
Scan “3rd Insertion” and set the identified position to “16”, then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection.
63
Scan “END” (Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the preset working flow as below:
Verifier  Formatter  Replacer  Organizer
So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter.
Wireless FuzzyScan
Appendix
Symbology ID Table
Each AIM Code Identifier contains the three-character string ]cm where:
] = Flag Character c = Code Character m = Modifier Character
Cino ID AIM ID Cino ID AIM ID
Code Family
UPC
Code 128
Codabar Codabar/NW-7 D F m MSI/Plessey MSI/Plessey R M m
Code 25
IATA IATA O R m
UCC Coupon
Primary Format
UPC-A m EAN/JAN-8 4
UPC-A with 2 supple. 1 EAN/JAN-8 with 2 supple. 1
UPC-A with 5 supple.
UPC-E m EAN/JAN-13 m
UPC-E with 2 supple. 1 EAN/JAN-13 with 2 supple. 1
UPC-E with 5 supple.
Example: A UPC-A bar code 012345678950 with 2 supplement 12 is transmitted as ]E0012345678950]E112
Code 128 B m Code 93 Code 93 H G m
UCC/EAN-128 C
Standard/Industrial 2 of 5 I S 0 UK/Plessey UK/Plessey S P 0
Matrix 2 of 5 K X 0 Telepen Telepen T B m
Interleaved 2 of 5 J I m GS1 DataBar GS1 Databar
China Postal Code L X 0
German Postal Code M I 3 Code 39 Trioptic W X 0
UCC Coupon Code Z PDF417 PDF417/Micro PDF417 V L 0
Example : A UPC-A 512345678900 + UCC/EAN-128 81010123451297 bar code is transmitted as]E0512345678900]C181010123451297
Example: A EAN-13 9923456789019 + UCC/EAN-128 81010123451297 bar code is transmitted as ]E09923456789019]C181010123451297
Code
Character
A
E
Code
Character
E
C
Modified
Character
2 EAN/JAN-8 with 5 supple.
2 EAN/JAN-13 with 5 supple.
1 Code 11 Code 11 P H m
Code Family
EAN/JAN
Compsoite Composite Code
Code 39
Codablock Codablock F Y O 0
Korea Post Korea Post Code a X 0
Remark: Above examples are given for the transmission of AIM ID.
Primary Format
Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is transmitted as ]E449123562]E212345
Code 39 G A m
Code 32 G A 0
Code
Character
N E
F E
X e 0
Code
Character
Modified
Character
2
2
64
Wireless FuzzyScan
Keyboard Function Code Table
Appendix
No. ANSI ASCII
00 NUL 00H RESERVED 16 DLE 10H F7
01 SOH 01H CTRL (Left) 17 DC1 11H F8
02 STX 02H ALT (Left) 18 DC2 12H F9
03 ETX 03H SHIFT 19 DC3 13H F10
04 EOT 04H CAPS LOCK 20 DC4 14H F11
05 ENQ 05H NUM LOCK 21 NAK 15H F12
06 ACK 06H ESC 22 SYN 16H INS (Insert) (Edit)
07 BEL 07H F1 23 ETB 17H DEL (Delete) (Edit)
08 BS 08H BACK SPACE 24 CAN 18H HOME (Edit)
09 HT 09H TAB 25 EM 19H END (Edit)
10 LF 0AH F2 26 SUB 1AH PAGE UP (Edit)
11 VT 0BH F3 27 ESC 1BH PAGE DOWN (Edit)
12 FF 0CH F4 28 FS 1CH UP (Edit)
13 CR 0DH ENTER (CR) 29 GS 1DH DOWN (Edit)
14 SO 0EH F5 30 RS 1EH LEFT (Edit)
15 SI 0FH F6 31 US 1FH RIGHT (Edit)
Key Function No. ANSI ASCII
Key Function
To emulate the keyboard function key input for user definable parameters, user must configure actual content using the Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.
65
Wireless FuzzyScan
Appendix
ASCII Input Shortcut
To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details.
Example:
If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference.
Scan the system command – PROGRAM listed on page
3-24 to enter programming mode.
Scan family code – PREAMBLE to select this family.
Refer to the Hex/ASCII Table, you will find the HEX value
of “$” is 24.
Scan the option code – 2 listed on the fold out back cover.
Scan the option code – 4 listed on the fold out back cover.
Scan the system command – FIN (Finish) to terminate
Preamble setting.
HEX/ASCII Reference Table
H
L
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 1 2 3 4 5 6 7
NUL DLE SPACE 0 @ P ` p
SOH DC1
STX DC2
ETX DC3
EOT DC4
ENQ NAK
ACK SYN
BEL ETB
BS CAN
HT EM ) 9 I Y i y
LF SUB
VT ESC
FF FS , < L \ l |
CR GS - = M ] m }
SO RS . > N ^ n ~
SI US / ? O _ o DEL
! 1 A Q a q
" 2 B R b r
# 3 C S c s
$ 4 D T d t
% 5 E U e u
& 6 F V f v
' 7 G W g w
( 8 H X h x
* : J Z j z
+ ; K [ k {
Scan the system command – End to exit the programming
mode for normal operation.
66
Example : ASCII “A” HEX “41”; ASCII “a” “61”
: High Byte of HEX Value
: Low Byte of HEX Value
Wireless FuzzyScan
Link Mode Quick Set
Appendix
Uninstall
HID Mode
PICO Mode
Operation Mode Quick Set
PAIR Mode
SPP Slave Mode
SPP Master Mode
Trigger Mode Presentation Mode
67
Wireless FuzzyScan
Host Interface Quick Set
(Work with Smart Cradle only)
Appendix
RS232 Serial
Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode
USB HID Turbo Mode
USB Com Port Emulation
USB HID Standard Mode 
PS/2 (DOS/V) KBW Standard Mode
68
Wireless FuzzyScan
Option Codes
Appendix
0
1
2
3
7 F
4
5
6
8
9
A
B
C
D
E
FIN (Finish)
69
END (Exit)
Wireless FuzzyScan
System Commands
Appendix
PROGRAM
(Enter Programming Mode)
Sleep
FIN (Finish) Clone
Paging
END
(Exit Programming Mode)
PowerTool Host Link
Factory Default
Save Configuration
System Information List
(SYSLIST)
Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the scanner will revert to uninstall state).
Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), Wand/Laser Emulation Control, Bluetooth Device Name, Bluetooth PIN Code, and Out-of-range Scanning, the rest of parameters will be returned to default value (The radio link is still keep
on).
Save User Default User Default
User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and would like to return to previous setting, please scan “User Default”.
Master Default
70
Wireless FuzzyScan
Appendix
Link
Indicator
Status Indicator
Indications
Descriptions Link Indicator Beeper
Radio connected 1 blue blink per 2.5 sec. Off Radio disconnected 3 blue blinks per 2 sec. Off During connection Quick blue blinks Short clicks Radio connection built 1 blue blink per 2.5 sec. 4 beeps in ascending tone Radio connection lost 3 blue blinks per 2 sec. 4 beeps in descending tone Data Transmission Quick blue blink Short clicks
Descriptions Status Indicator Beeper
Under charging (on cradle) Steady red Off Fully charged (on cradle) 1 green blink at regular interval Off Under batch scanning 1 green blink per 2.5 sec. Off Pair failure Steady red 2 Di-do Di-do beeps Out of memory 2 red blinks 2 long beeps Battery power low 1 red blink at regular interval 1 beep at regular interval Battery power extremely low 8 red blinks 8 beeps Good read 1 green blink 1 good read beep Under Configuration Steady red Off Uninstall state Alternative red and green blinks Off Upgrade state Steady red Short click Time out warning Off 3 long beeps Paged by smart cradle Off 6 page beeps Sleep state / Battery no power Off Off
71
Wireless FuzzyScan
Appendix
Center Indicator
Side Indicators
HB2100 Charging Cradle Indication
Descriptions Power Beeper
Power on Steady blue Off
HB2110 Smart Cradle Indications
Descriptions
Center Side
Power on 1 blue blink Off Power on beeps Smart Cradle Upgrade State Off Steady red Short clicks Uninstall state Off Alternative red-green blinks Off
PICO Mode
PAIR Mode
Smart cradle paged by scanner
Radio Connected Steady blue Steady Green Off Radio Disconnected Off Steady red Off Radio Connected Steady blue Off Off Radio Disconnected Off Steady red Off PICO Mode Steady blue Steady green 6 page beeps PAIR Mode Steady blue Off 6 page beeps
Indicators
Beeper
72
CINO GROUP
FuzzyScan Wireless Reference Manual
PC WORTH INT’L CO., LTD.
www.cino.com.tw
Loading...