Cineo Lighting DTZ Calibration Guide

TruColor HS Dim-to-Zero Power Supply (DTZ)
Calibration Guide
The calibration data is stored in the power supply, and is, for the most part completely compatible with any HS or LS lamphead attached. For critical applications, calibration can be improved by performing a calibration for the specifi c PSU / lamphead pairing.
TruColor HS DTZ power supplies feature full dimming from 0-100% on both local and DMX control. They are identifi ed by a “DTZ” label located on the face plate of the unit:
The DX450 DTZ includes a new calibration routine that accurately adjusts the dimming curve for optimal performance.
To calibrate, please follow these instructions:
1. Attach this power supply to a TruColor HS
lamphead.
2. Set the DMX address to “999”.
3. Cycle power on the power supply.
4. The Calibration cycle will fl ash the yellow
LED while it performs the routine: approx. 50 sec.
5. When yellow LED goes solid “ON”,
calibration is complete. Reset the DMX address to desired value.
Specifi cations are subject to change without notice. Cineo Lighting, TruColor, TruColor HS, are registered trademarks of Cineo Lighting, Inc. ©2014 Cineo Lighting, Inc. v10.24.14
Silicon Valley | Los Angeles | London
info@cineolighting.com
+1 310.425.3425
www.cineolighting.com