Page | 1
4871.MOT.V1
MINING OUTLET TESTER
PATENT PENDING NO: AU2017902878
PRODUCT MANUAL

Page | 2
Contents
1. SAFETY MEASURE ................................................................. 3
2. FEATURES ............................................................................. 6
2.1 Instrument Layout .................................................... 6
2.2 Test Function ............................................................ 7
2.3 Applied Standards .................................................... 8
2.4 Features & Specification .......................................... 8
3. TESTING INSTRUCTIONS ..................................................... 10
3.1 EARTH LEAKAGE LOCKOUT TEST (ELL) ................... 11
3.2 FROZEN CONTACT TEST (FC) .................................. 13
3.3 EARTH CONTINUITY (EC) ........................................ 15
3.4 REMOTE START/STOP ............................................ 17
3.5 EARTH LEAKAGE TEST (EL) ..................................... 18
3.6 PHASE INFORMATION ............................................ 22
4. SERVICING .......................................................................... 24

Page | 3
1. SAFETY MEASURE
This Instrument has been designed and tested according
to IEC 61010: Safety Requirements for Electronic
Measuring Apparatus. This instruction manual contains
safety rules and warnings which must be followed by
the user to ensure safe operation of the instrument and
safe working conditions. Read these instructions
carefully before using this instrument.
CONDTION OF USE:
This instrument must only be used by a competent and
trained person with adequate certification, such as a
licenced electrician. CIE will not accept liability for any
damage or injury caused by misuse or non-compliance
with the instructions. It is important to read and to
understand the safety rules contained in the instructions
provided.
DANGER is reserved for conditions and actions
that are likely to cause serious or fatal injury.
WARNING is reserved for conditions and
actions that can cause serious or fatal injury.
CAUTION is reserved for conditions and actions
that can cause a minor injury or instrument damage

Page | 4
DANGER
- This instrument is to be used only for intended
applications and under safe conditions,
otherwise safety functions of this equipment will
not work, and instrument damage or serious
personal injury may occur.
- When conducting tests do not touch any
exposed metalwork associated with the
installation. In certain tests this metalwork may
become live for the duration of test.
WARNING
- This instrument is to be used only for the
intended applications and in safe conditions.
- This instrument and testing must be performed
by trained professionals with appropriate
licences.
- Conduct all tests according to the safety
procedures provided by your workplace.
- Do not remove internal the sealed front cover
of the instrument - there are dangerous voltages
present and this may void the manufacturer
warranty.
- If a fault occurs with this instrument, return it to
your distributor for inspection and repair.
- If any abnormality such as a faulty display,
broken case, cracked screen etc. occurs with the

Page | 5
instrument do not use it and return it to your
distributor for repair.
- Never attempt to use this instrument in wet
conditions.
CAUTION
- For safety reasons only use accessories that are
designed to be used with this instrument and
recommended by CIE.
- Use a damp cloth and a mild detergent to clean
the instrument. Do not use abrasive materials or
solvents (eg. methylated spirits).

Page | 6
2. FEATURES
2.1 Instrument Layout
1……… Instrument On/Off
2……… Battery Voltage Indication
3……… Main Control Touch Screen LCD
4……… Battery Charging socket
5……… Earth Leakage Current Selector Switch (1000V
& 415V)

Page | 7
6……… Frozen Contact Voltage Potentiometer
7……… Frozen Contact Voltage Indicator
8……… RGB colour LED indicator light
This instrument is
supplied with an
Appliance Inlet DS3
1000V 3PE&2Aux 32A,
where the test device
will connect via test
lead.
2.2 Test Function
4871.MOT.V1 performs the following 6 test functions.
1. Earth Leakage Lockout
2. Frozen Contact
3. Earth Continuity
4. Remote Start and Stop
5. Earth leakage with trip time

Page | 8
6. Phase information
2.3 Applied Standards
Instrument operation: IEC 61557-1
Safety: IEC 61010-1, CAT III(1000V),
CAT IV 600V, IEC 60950
Protection degree: Operational IEC60529(IP54)
Instrument in Storage 0529(IP64)
2.4 Features & Specification
4871.MOT.V1 comprises the following features:
• High speed
• User friendly
• Touch screen operation for all tests
• Live battery voltage information
• Phase information
o Phase-Phase voltage, Phase-Earth voltage
o Phase Rotation, Phase status information
• Earth continuity, short circuit and open circuit
tests