Ciclotron DBS-720 Schematic

INPUT CH B
INPUT CH B
VOL. CH AVOL. CH B
INPUT CH A
OVERLOAD CH A/B
47K
6
2K2x1/2W
10K
1
IC1003
8
10K
5 2 3 7 4
2K2x1/2W
+
47uFx50V
+
47uFx50V
2K2
2K2
22pFx100V
1K5
+
47uF47uF
+
22R
470R
BD140
33K
1K5
470R
BD139
330R 330R
INPUT CH A
18V
BC547
22K
50KB
50KB
22K
15K
BC547
15K
4K7
4K7
220R
4.7uF
4.7uF
+
BC557
4K7220R
+
BC557
4K7
4K7
100K
1K
+
6V2
+
6V2
100K
CH A
CH A/B
CH B
+B1
-B1
100K
470K
2K2
2K2
PL279
CLIP B
CLIP A
PL281
18V
100K
AJUSTE OV
10K
AJUSTE
CORRENTE
47Rx1/2W
BC337
BD135
BC327
47Rx1/2W
1N4148
10K
10K
12K
1N4148
1N4148
12K
39pFx500V
100R
+
47uF
+
47uF
100R
39pFx500V
1K2
1K2
100Rx1W
100Rx1W
BD139
BD140
0.47Rx5W 0.47Rx5W
2SC5198
2SA1941
1N4002 1N4002
100Kx50V
10Rx2W
100Kx50V
+B
10Rx2W
100Kx50V
-B
PL231
PL281
OUT A/B
OUT A/B
CANAL A / CANAL B
REDE
250V x 10A
10Kx630V
PLA005
22OV
110V
3A
TERRA EXTERNO
TDBS720
8 x 1N4001
+
2200uF
2200uF
x50V
+
2200uF
x50V
PL232A
FONTE
x50V
2200uF
+
+
x50V
1Kx2W
3K3x1W
1Kx2W
+B1
+B
-B
+B
-B
-B1
CH A
CH B
ON
VISTA SUPERIOR
IC1003
TENSÃO DO TRAFO TENSÃO DA FONTE (+B) TENSÃO DA FONTE (-B) TENSÃO DA FONTE (+B1) TENSÃO DA FONTE (-B1)
VISTA FRONTAL
BD 135 BD 139
2SA1914
BD 140
2SC5198
1 2
3 4 5
ECB
6 7 8
BCE
EM REPOUSO
+ 40,5 Vdc
- 40,5 Vdc + 6,2 Vdc
Os canais A e B são idênticos. Todos resistores são de 1/4 W e todos capacitores eletrolíticos são de 25V,
BC 547
exceto aqueles com indicação.
BC 557
* A corrente quiescente deve ser medida
BC 327 BC 337
sobre um dos resistores de 0.47Rx5W, estando o aparelho com carga e sem sinal de entrada. ** O ajuste de 0V deverá ser feito nos jacks de saída, estando o aparelho
CBE
sem carga e sem sinal de entrada.
POT. MÁXIMA
29,8 Vac
- 6,2 Vdc
26,4 Vac
+ 32,1 Vdc
- 32,1 Vdc + 6,2 Vdc
- 6,2 Vdc
CORRENTE QUIESCENTE AJUSTE DE OV
12,7 mA ( 5,9mV DC)*
DBS 720
CIRCUITO: POWER / FONTE
ARQUIVO:..\DBS720_V1.DSN
3 mV DC**
I N D Ú S T R I A E L E T R Ô N I C A L T D A.
DATA: 25/05/2001
FOLHA: 01/01
1 - 32