5. SETTINGS
It is possible to program the unit to switch automatically from comfort mode to economy mode at
pre-set times which can be different every day of the week.
To do this, configure the weekly programming mode.
To define the program to be used in heating mode, position the dial to:
To define the program to be used in cooling mode (depending on the model), position the dial
to:
5.1 Configuring the weekly programming
The display then shows:
.
Hour by hour over 24 hours, define if the unit should operate:
- In comfort mode: + button
- In economy mode: - button
Once programming has been completed for one day, skip to the next using the OK button
If you program the nights in economy mode (
), ensure that you do not drop the setpoint
more than 3°C below the comfort setpoint (
) so that the temperature can be easily raised
again in the morning.
5.2 Activating/deactivating the weekly programming
When the weekly programming information has been entered, position the function selector to
heating or cooling mode (depending on the model). Activate the programmed mode by pressing
OK several times (see paragraph 4.2)
• The unit will now run the program, switching between modes (economy
/comfort ) as you
have requested.
• To deactivate the program mode, press OK again to run simple comfort mode (
) or simple
economy mode (
)(see paragraph 5)
5.3 If a fault is displayed
5.3.1 Type of fault
In any event, the control terminal displays information in the format "type dx.x" (where x.x is
a numerical value); the pump has detected a fault. First, call your installer and give them the
fault code. While waiting for the installer, it is still possible to clear the fault and resume normal
operation (until the fault recurs).
Code(s) Fault type Solution
D1 & D2
Problem with the refrigerating circuit
Try and clear the fault and contact your
installer.
D3
Problem with the domestic hydraulic
unit
Check that the valves are open and the
hydraulic filter(s) are clean, and try and clear
the fault. Contact your installer
D4 Temperature sensor fault Contact your installer.
D5
Operating limits exceeded
The unit will resume normal operation as
soon as the outside temperature becomes
compatible with operation.
Inform your installer of the fault.
D6, D7,
D8
Risk of frost on the exchanger
Contact your installer urgently.
Do not clear the fault.
D9 Terminal operation problem Contact your installer.
Dx.xS Fault during DHW cycle Contact your installer