Switching Power Supply——LHE series A-35FAL
Features:
Miniature size and 30mm low profile
Withstand 300VAC input surge for 5 second
load power consumption<0.3W
-30℃-+70℃ working temperature(refer to
derating curve)
Protections: short
circuit/overload/over voltage
100% full load burn-in test
High efficiency, High reliability
2 years warranty
Application: Industrial control system,machinery and electrical equipment, electronic
instruments, industrial automation, household appliances, etc.
Approval:
Standard:
Product Description
Model Encoding
EN55024\EN61000-4-2,3,4,5,6,8,11\GB17625.1\EN61000-3-2,-3\EN55022\GB4943\UL1012
35FAL is single-output enclosed type power supply. Adopting the full range 90~264VAC input, the entire
series provides an output voltage line of 5V, 12V, 24V, 36V and 48V. It can be applied to industrial
control system, mechanical and electrical equipment, electronic instruments, industrial automation,
household appliances and other industrial fields. This series of products is designed for low power
consumption, with no-load power consumption less than 0.3W, which can make the terminal equipment
system easily meet the requirements of international energy conservation and environmental protection.
High efficiency, compact design and good heat dissipation ensure the long-term stable work of this
series of products.
A – 35 FAL - 5/12/15/24/36/48
1 File time 9/17/19
Switching Power Supply——LHE series A-35FAL
Input current
230VAC/0.4A
1000ms,30ms/220VAC 100%loading
Design refer to:EN55024 ;EN61000-4-2,3,4,5,6,8,11
Design refer to:GB17625.1;EN61000-3-2,-3
Design refer to:EN55022,Class B
Design refer to:GB4943/UL1012
I/P-O/P:3KVac/10mA; I/P-CASE:1.5KVac/10mA; O/P-CASE:0.5KVAC/10mA
Each testing time:1min
I/P-O/P: 100M ohms; I/P-Case:100M ohms; O/P-Case:100M ohms
shut down output voltage, re-power to recover
110~150% rated Hiccup mode, recovers automatically after fault condition is
removed
Hiccup mode, recovers automatically after fault condition is removed
Working
temperature and
humidity
-30~70℃ 20%~95%RH no condensing (refer to derating curve)
Storage
temperature and
humidity
-30℃~80℃; 10%~95%RH no condensing
Vibration
Frequency range 10 ~ 500Hz,acceleration 5G,Each sweep cycle 10min.6 sweep cycles
along X, Y and Z axes
Acceleration 20G,Duration 11mS,3 shocks along X, Y and Z axes
2000mtrs(for every 100 m higher than 2000 m, the ambient temperature decreases
by 0.6 ℃)
25℃:500000Hrs, MIL-217 Method
0.23Kg/piece, 60pcs/ctn,16KG/ctn
☑ terminal cover □ Low temperature start(-40℃) Others
*In order to extend the lifetime, it is recommended to configure the load more than 30% of the remaining
allowance. For example: the power of the device requires 100W, then use the power of not less than
130W.
*Ripple test method: 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length
is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency
capacitance probe.
*All electrical performance tests are performed at 25 C.
SPECIFICATION
2 File time 9/17/19