Chuanglian A-35FAL-5, A-35FAL-12, A-35FAL-15, A-35FAL-24, A-35FAL-36 User Manual

...
Switching Power Supply——LHE series A-35FAL
Features:
Miniature size and 30mm low profile Withstand 300VAC input surge for 5 second load power consumption<0.3W -30℃-+70℃ working temperature(refer to
derating curve)
Protections: short
circuit/overload/over voltage
2 years warranty
Single output
Rated wattage
Series name
Output voltage
Application: Industrial control system,machinery and electrical equipment, electronic
instruments, industrial automation, household appliances, etc.
Approval
Standard:
Product Description
Model Encoding
EN55024\EN61000-4-2,3,4,5,6,8,11\GB17625.1\EN61000-3-2,-3\EN55022\GB4943\UL1012
35FAL is single-output enclosed type power supply. Adopting the full range 90~264VAC input, the entire
series provides an output voltage line of 5V, 12V, 24V, 36V and 48V. It can be applied to industrial
control system, mechanical and electrical equipment, electronic instruments, industrial automation,
household appliances and other industrial fields. This series of products is designed for low power
consumption, with no-load power consumption less than 0.3W, which can make the terminal equipment
system easily meet the requirements of international energy conservation and environmental protection.
High efficiency, compact design and good heat dissipation ensure the long-term stable work of this
series of products.
A – 35 FAL - 5/12/15/24/36/48
1 File time 9/17/19
Switching Power Supply——LHE series A-35FAL
MODEL
A-35FAL-5
A-35FAL-12
A-35FAL-15
A-35FAL-24
A-35FAL-36
A-35FAL-48
Input
Voltage range
90~264VAC
Input current 230VAC/0.4A
115VAC/0.8A
Efficiency
82%
86%
86%
88%
88%
89%
Frequency range
47~63HZ
Leakage current
<3.5mA/240VAC
Inrush current
50A/230VAC
Output
DC voltage
5V
12V
15V
24V
36V
48V
Rated current
7A
3A
2.4A
1.5A
1A
0.8A
Power
35W
36W
36W
36W
36W
38W
Voltage adj.range
4.5~5.5V
10.813.2V
13.516.5V
21.626.4V
32.4
39.6V
43.2
52.8V
Ripple and noise
80mVp-p
120mVp-p
120mVp-p
150mVp-p
200mVp-p
200mVp-p
Set up,rise time
1000ms30ms/220VAC 100%loading
Hold up time
30ms/220VAC 100%loading
Line regulation
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Load regulation
±2.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Output Voltage Accuracy
±2.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
EMC
EMS
Design refer to:EN55024 ;EN61000-4-2,3,4,5,6,8,11
Harmonic current
Design refer to:GB17625.1;EN61000-3-2,-3
EMC
Design refer to:EN55022Class B
Safety
Safety standard
Design refer to:GB4943/UL1012
Withstand voltage
I/P-O/P:3KVac/10mA; I/P-CASE:1.5KVac/10mA; O/P-CASE:0.5KVAC/10mA Each testing time:1min
Isolation resistance
I/P-O/P: 100M ohms; I/P-Case:100M ohms; O/P-Case:100M ohms
Protection
Over voltage
5.75
6.9V
13.816.2V
18.7521.75V
28.833.6V
41.4
48.6V
55.2
64.8V
shut down output voltage, re-power to recover
Over load
110~150% rated Hiccup mode, recovers automatically after fault condition is removed
Short circuit
Hiccup mode, recovers automatically after fault condition is removed
Environment
Working temperature and humidity
-30~70 20%~95%RH no condensing refer to derating curve)
Storage temperature and humidity
-30℃~80℃; 10%~95%RH no condensing Vibration
Frequency range 10 ~ 500Hz,acceleration 5GEach sweep cycle 10min.6 sweep cycles along X, Y and Z axes
Shock
Acceleration 20GDuration 11mS3 shocks along X, Y and Z axes
Altitude
2000mtrs(for every 100 m higher than 2000 m, the ambient temperature decreases by 0.6 ℃)
Reliability
MTBF
25℃:500000Hrs, MIL-217 Method
Others
Size
99*82*30 mmL*W*H
Packing
0.23Kg/piece, 60pcs/ctn16KG/ctn
Cooling mode
Free air □ Fan
Extension mode
terminal cover Low temperature start-40℃) Others
Remark
*In order to extend the lifetime, it is recommended to configure the load more than 30% of the remaining allowance. For example: the power of the device requires 100W, then use the power of not less than 130W. *Ripple test method: 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency capacitance probe. *All electrical performance tests are performed at 25 C.