Standard Diodes, 60/80 A
(ADD-A-PAK
ADD-A-PAK
TM
VSK.56..PbF/VSK.71..PbF Series
Vishay High Power Products
TM
Generation 5 Power Modules)
FEATURES
• High voltage
• Industrial standard package
• Thick copper baseplate
• UL E78996 approved
• 3500 V
• Totally lead (Pb)-free
• Designed and qualified for industrial level
isolating voltage
RMS
RoHS
COMPLIANT
PRODUCT SUMMARY
I
F(AV)
60/80 A
BENEFITS
• Up to 1600 V
• Full compatible TO-240AA
MECHANICAL DESCRIPTION
The Generation 5 of ADD-A-PAKTM module combine the
excellent thermal performance obtained by the usage of
direct bonded copper substrate with superior mechanical
ruggedness, thanks to the insertion of a solid copper
• High surge capability
• Easy mounting on heatsink
•Al
DBC insulator
203
• Heatsink grounded
baseplate at the bottom side of the device. The Cu baseplate
allow an easier mounting on the majority of heatsink with
increased tolerance of surface roughness and improve
thermal spread.
The Generation 5 of AAP module is manufactured without
hard mold, eliminating any possible direct stress on the
leads.
ELECTRICAL DESCRIPTION
These modules are intended for general purpose high
voltage applications such as high voltage regulated power
supplies, lighting circuits, temperature and motor speed
control circuits, UPS and battery charger.
The electrical terminals are secured against axial pull-out:
they are fixed to the module housing via a click-stop feature
already tested and proved as reliable on other Vishay HPP
modules.
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL CHARACTERISTICS VSK.56 VSK.71 UNITS
I
F(AV)
I
F(RMS)
I
FSM
2
t
I
2
I
√t 128.9 159 kA2√s
V
RRM
T
J
T
Stg
100 °C 60 80
94 126
50 Hz 1600 1790
60 Hz 1680 1870
50 Hz 12.89 15.90
60 Hz 11.76 14.53
Range 400 to 1600 V
- 40 to 150 °C
A
kA2s
Document Number: 94358 For technical questions, contact: ind-modules@vishay.com
Revision: 04-Jul-08 1
www.vishay.com
VSK.56..PbF/VSK.71..PbF Series
Vishay High Power Products
Standard Diodes, 60/80 A
(ADD-A-PAKTM Generation 5 Power Modules)
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
V
, MAXIMUM NON-REPETITIVE
RSM
PEAK REVERSE VOLTAGE
V
TYPE NUMBER
VOLTAGE
CODE
V
, MAXIMUM REPETITIVE
RRM
PEAK REVERSE VOLTAGE
V
04 400 500
06 600 700
08 800 900
VSK.56/.71
10 1000 1100
12 1200 1300
14 1400 1500
16 1600 1700
FORWARD CONDUCTION
PARAMETER SYMBOL TEST CONDITIONS VSK.56 VSK.71 UNITS
Maximum average forward current
at case temperature
Maximum RMS forward current I
Maximum peak, one-cycle forward,
non-repetitive surge current
2
Maximum I
Maximum I
t for fusing I2t
2
√t for fusing I2√t t = 0.1 to 10 ms, no voltage reapplied 128.9 159.0 kA2√s
Low level value of threshold voltage V
High level value of threshold voltage V
Low level value of forward
slope resistance
High level value of forward
slope resistance
Maximum forward voltage drop V
I
F(AV)
F(RMS)
I
FSM
F(TO)1
F(TO)2
r
f1
r
f2
FM
180° conduction, half sine wave
DC at 92 °C case temperature 94 126
t = 10 ms
t = 8.3 ms 1680 1870
t = 10 ms
t = 8.3 ms 1420 1570
t = 10 ms
t = 8.3 ms 11.76 14.53
t = 10 ms
t = 8.3 ms 8.32 10.23
(16.7 % x π x I
(I > π x I
(16.7 % x π x I
(I > π x I
IFM = π x I
No voltage
reapplied
100 % V
RRM
reapplied
No voltage
Sinusoidal half wave,
intitial T
= TJ maximum
J
reapplied
100 % V
RRM
reapplied
< I < π x I
F(AV)
), TJ = TJ maximum 1.03 0.92
F(AV)
< I < π x I
F(AV)
), TJ = TJ maximum 2.48 2.40
F(AV)
, TJ = 25 °C, tp = 400 µs square wave 1.51 1.50 V
F(AV)
), TJ = TJ maximum 0.96 0.83
F(AV)
), TJ = TJ maximum 2.81 2.68
F(AV)
60 80 A
100 100 °C
1600 1790
1350 1500
12.89 15.90
9.12 11.25
I
MAXIMUM
RRM
AT 150 °C
mA
10
kA
mΩ
A
2
s
V
BLOCKING
PARAMETER SYMBOL TEST CONDITIONS VSK.56 VSK.71 UNITS
Maximum peak reverse
leakage current
RMS insulation voltage V
www.vishay.com For technical questions, contact: ind-modules@vishay.com
2 Revision: 04-Jul-08
I
RRM
INS
TJ = 150 °C 10 mA
50 Hz, circuit to base, all terminals shorted 3500 (1 s) V
Document Number: 94358