6121 Baker Road,
Suite 108
Minnetonka, MN 55345
www.chtechnology.com
Phone (952) 933-6190
Fax (952) 933-6223
1-800-274-4284
Thank you for downloading this document from C&H Technology, Inc.
Please contact the C&H Technology team for the following questions -
Technical
Application
Assembly
Availability
Pricing
Phone – 1-800-274-4284
E-Mail – sales@chtechnology.com
www.chtechnology.com - SPECIALISTS IN POWER ELECTRONIC COMPONENTS AND ASSEMBLIES - www.chtechnology.com

SECURITY
CODE
Spec. NAME
Customer’s
Std. Spec.
Prepared by K.Kurachi
Checked by
Approved by I.Umezaki
DATE 4-Feb.-2008
MITSUBISHI ELECTRIC CORPORATION
R
E
V
HIGH VOLTAGE DIODE MODULE
1. Type Number RM400DG-66S
2. Structure Flat base type (Insulated package, AlSiC base plate)
3. Application & Customer High power converters & Inverters for traction application
4. Outline See Fig. 1
5. Related Specifications
HIGH VOLTAGE DIODE MODULE
Fig. 1 - Outline drawing
HVM-2012
(HV-SETSU)
PAGE
1 / 11

6. Maximum Ratings
MITSUBISHI ELECTRIC CORPORATION
Item Symbol Conditions Ratings Unit
Repetitive peak reverse voltage V
Non-repetitive peak reverse
voltage
Reverse DC voltage V
DC forward current IF T
Surge forward current I
Surge current load integral I2t
Isolation voltage V
T
RRM
T
V
RSM
R(DC)
FSM
iso
= 25 °C 3300 V
j
= 25 °C 3300 V
j
Tj = 25 °C 2200 V
= 25 °C 400 A
c
T
= 25 °C start, tw = 8.3 ms
j
Half sign wave
T
= 25 °C start, tw = 8.3 ms
j
Half sign wave
Charged part to the baseplate
RMS sinusoidal, 60Hz 1min.
3200 A
42.7 kA
10200 V
Junction temperature Tj — −40 ~ +150 °C
Storage temperature T
— −40 ~ +125 °C
stg
Operating temperature Top — −40 ~ +125 °C
V
≤ 2200 V
Maximum reverse recovery
instantaneous power
—
R
di/dt ≤ 1800 A/µs, T
[See Fig.1, Fig.2, 12-5]
= 125 °C
j
800 kW
7. Electrical Characteristics
2
s
Item Symbol Conditions
Repetitive reverse current I
RRM
Forward voltage VFM
VRM = V
IF = 400 A
RRM
(Note 1)
Tj = 25 °C
Tj = 125 °C
Tj = 25 °C
Tj = 125 °C
Limits
Min. Typ. Max.
— — 2
— 1 10
— 2.80 —
— 2.70 —
Unit
mA
V
Reverse recovery time trr — 1.00 — µs
V
= 1650 V, IF = 400 A
Reverse recovery current Irr — 530 — A
Reverse recovery charge Qrr — 270 — µC
Reverse recovery energy E
Note 1: It doesn't include the voltage drop by Internal lead resistance.
rec
HIGH VOLTAGE DIODE MODULE
R
di/dt = −1350 A/µs
= 125 °C
T
j
HVM-2012
[See Fig.1,Fig.2]
— 0.3 — J/P
(HV-SETSU)
PAGE
2 / 11

8. Thermal Characteristics
MITSUBISHI ELECTRIC CORPORATION
Item Symbol Conditions
Thermal resistance R
Contact thermal resistance R
Note 2: Thermal conductivity is 1W/mK with a thickness of 100µm.
th(j-c)R
th(c-f)
Junction to case
(per 1/2 module)
Case to fin
Conductive grease applied
(per 1/2 module)
(Note 2)
Limits
Min. Typ. Max.
Unit
— — 54.0 K/kW
— 48.0 — K/kW
9. Mechanical Characteristics
Item Symbol Conditions
Mounting torque —
Mounting torque —
Main terminal screw : M8
Mounting screw : M6
Mass — — — 1.0 — kg
Comparative tracking index CTI — 600 — — —
Limits
Min. Typ. Max.
Unit
7.0 — 15.0 N·m
3.0 — 6.0 N·m
Clearance — — 26 — — mm
Creepage distance — — 56 — — mm
Internal inductance L
Internal lead resistance R
— — 44 — nH
A-K(int)
A-K(int)
Tc = 25 °C — 0.27 — mΩ
10. Shipping Inspection Report Item
Static characteristics : I
Dynamic characteristics : t
Note 3: One shipping inspection report with the above item values is submitted when modules are delivered. The test
conditions are defined in bracket.
RRM
[7.3], Qrr [7.5]
rr
(note 3)
[7.1], VFM [7.2]
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
3 / 11

MITSUBISHI ELECTRIC CORPORATION
11. Test Circuit & Definition of Switching Characteristics
S1
= 500 nH
L
Rg
LOAD
L
L
K
DUT: diode
S2
= 100 nH
VCC C = 2 mF
Diode part: reverse recovery
IF
di/dt
0
0
di
Irr
trr
dt
10%V
S
C
= 200 uF
A
Fig. 1 – Switching test circuit
= –
= –
t6
if dt
0
t6
if•vr dt
t5
Qrr
V
R
10%IF
50%Irr
90%Irr
R
Erec
t5
0
t6
Fig. 2 – Definitions of reverse recovery charge & energy
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
4 / 11

MITSUBISHI ELECTRIC CORPORATION
12. Performance curves
12-1 Forward characteristics...................................................................................................6
12-2 Reverse recovery energy characteristics ......................................................................7
12-3 Reverse recovery current characteristics......................................................................8
12-4 Transient thermal impedance characteristics...............................................................9
12-5 Reverse recovery safe operating area .........................................................................10
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
5 / 11

MITSUBISHI ELECTRIC CORPORATION
12-1 Forward characteristics
800
700
600
500
[A]
F
400
Forward current I
300
200
100
0
Tj=125°C Tj=25°C
0123456
Forward voltage VFM [V]
Forward voltage characteristics (typical)
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
6 / 11

MITSUBISHI ELECTRIC CORPORATION
12-2 Reverse recovery energy characteristics
0.5
0.4
0.3
0.2
Reverse recovery energy Erec [J/P]
Tj = 125°C, V
= 1650V
R
Ls = 100nH, Inductive load
Integration range: 10%V
~10%IF
R
0.1
0.0
0 100 200 300 400 500 600 700 800 900
Reverse recovery energy characteristics (typical)
HIGH VOLTAGE DIODE MODULE
Forward current IF [A]
HVM-2012
(HV-SETSU)
PAGE
7 / 11

MITSUBISHI ELECTRIC CORPORATION
12-3 Reverse recovery current characteristics
1000
Tj = 125°C, VR = 1650V
Ls = 100nH,
800
]
600
Inductive load
Reverse recovery current Irr [
400
200
0
0 100 200 300 400 500 600 700 800 900
Forward current IF [A]
Reverse recovery current characteristics (typical)
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
8 / 11

MITSUBISHI ELECTRIC CORPORATION
12-4 Transient thermal impedance characteristics
1.2
Rth(j-c) = 54 K/kW
1.0
0.8
0.6
0.4
Normalized transient thermal impedance
0.2
0.0
0.001 0.01 0.1 1 10
Time [sec.]
Transient thermal impedance characteristics
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
9 / 11

MITSUBISHI ELECTRIC CORPORATION
12-5 Reverse recovery safe operating area
1000
800
[A]
600
Tj = 125°C, VR ≤ 2200 V
di/dt ≤ 1800A/µs
400
Reverse recovery current Irr
200
0
0 1000 2000 3000 4000
Reverse voltage VR [V]
Reverse recovery safe operating area (RRSOA)
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
10 / 11

MITSUBISHI ELECTRIC CORPORATION
Rev.
No.
−
Summary of changes
Original
Signature
& date
K.Kurachi
31-Jan.-2008
HIGH VOLTAGE DIODE MODULE
HVM-2012
(HV-SETSU)
PAGE
11 / 11