6121 Baker Road,
Suite 108
Minnetonka, MN 55345
www.chtechnology.com
Phone (952) 933-6190
Fax (952) 933-6223
1-800-274-4284
Thank you for downloading this document from C&H Technology, Inc.
Please contact the C&H Technology team for the following questions -
Technical
Application
Assembly
Availability
Pricing
Phone – 1-800-274-4284
E-Mail – sales@chtechnology.com
www.chtechnology.com - SPECIALISTS IN POWER ELECTRONIC COMPONENTS AND ASSEMBLIES - www.chtechnology.com

Ordering Information:
Select the complete eight-digit
module part number from the table
below.
Example: PS431815 is a 1800 Volt,
1500A Average Single SCR
Isolated POW-R-BLOKTM Module
Description:
Powerex Single SCR Modules are designed
for use in applications requiring phase
control and isolated packaging. The
modules are isolated for easy mounting with
other components on a common heatsink.
Features:
Electrically Isolated Heatsinking
Compression Bonded Elements
Paralleled SCRs in Module for
Increased Capacity
Metal Baseplate
Low Thermal Impedance
for Improved Current Capability
Benefits:
No Additional Insulation
Components Required
Easy Installation
No Clamping Components
Required
Reduce Engineering Time
Applications:
Bridge Circuits
AC & DC Motor Drives
Motor Soft Starters
Battery Supplies
Power Supplies
Large IGBT Circuit Front Ends
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOK
www.pwrx.com Single SCR Isolated Module
1500 Amperes / Up to 1800 Volts
TM
Revision Date: 04/05/2011

Repetitive Peak Forward and Reverse Blocking
Voltage
Non-Repetitive Peak Blocking Voltage
(t < 5 msec)
RMS Current AC Switch Configuration
(180 o Conduction)
(Two PS43__15 in AC Switch Configuration)
180 Conduction, TC=86C
180 Conduction, TC=89C
180 Conduction, TC=93C
180 Conduction, TC=96
I
T(RMS)
I
T(RMS)
I
T(RMS)
I
T(RMS)
RMS Current
(180 o Conduction)
180 Conduction, TC=86C
180 Conduction, TC=89C
180 Conduction, TC=93C
180 Conduction, TC=96C
I
T(RMS)
I
T(RMS)
I
T(RMS)
I
T(RMS)
Average Forward Current
(180 o Conduction)
180 Conduction, TC=86C
180 Conduction, TC=89C
180 Conduction, TC=93C
180 Conduction, TC=96C
I
T(AV)
I
T(AV)
I
T(AV)
I
T(AV)
Peak One Cycle Surge Current, Non-Repetitive
Tj = 25C, Vr = 0
Peak One Cycle Surge Current, Non-Repetitive
Tj = 25C, Vr = Vrrm
Peak One Cycle Surge Current, Non-Repetitive
Tj = 125C, Vr = 0
Peak One Cycle Surge Current, Non-Repetitive
Tj = 125C, Vr = Vrrm
Peak Three Cycle Surge Current, Non-Repetitive
60 Hz, Tj = 125C, Vr = Vrrm
Peak Ten Cycle Surge Current, Non-Repetitive
60 Hz, Tj = 125C, Vr = Vrrm
I2t for Fusing for One Cycle
Tj = 125C, Vr = Vrrm
8.3 milliseconds
10 milliseconds
Maximum Rate-of-Rise of On-State Current,
(Non-Repetitive)
Per JEDEC Standard 397 5.2.2.6
Maximum Rate-of-Rise of On-State Current,
(Repetitive)
Per JEDEC Standard 397 5.2.2.6
Max. Mounting Torque, M6 Mounting Screw
Max. Mounting Torque, M10 Terminal Screw
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOK
www.pwrx.com Single SCR Isolated Module
1500 Amperes / Up to 1800 Volts
TM
Information presented is based upon manufacturers testing and projected capabilites.
This information is subject to change without notice.
The manufacturer makes no claim as to suitability for use, reliability, capability,
or future availability of this product.
Revision Date: 04/05/2011

Electrical Characteristics, TJ=25C unless otherwise specified
Repetitive Peak Forward Leakage Current
Repetitive Peak Reverse Leakage Current
Threshold Voltage, Low-level
Slope Resistance, Low-level
TJ = 125C, I = 15%I
T(AV)
to πI
T(AV)
Threshold Voltage, High-level
Slope Resistance, High-level
TJ = 125C, I = πI
T(AV)
to I
TSM
VTM Coefficients, Full Range
TJ = 125C, I = 50A to 15kA
VTM = A+ B Ln I +C I + D Sqrt I
0.7963
-3.77 E-02
3.65 E-05
7.19 E-03
Critical Rate of Rise of Off-State
Voltage
Exponential to 0.67V
DRM
Tj=125C, Gate Open
Tj=25C, VD=12V
Min Ig Required to Ensure Turn-On of
Paralleled SCRs in Module
Non-Triggering Gate Voltage
Peak Forward Gate Current
Peak Reverse Gate Voltage
Maximum Average Gate Power Dissipation
Thermal Resistance, Junction to Case
Per Module, both conducting
Thermal Impedance Coefficients
Z
ΘJ-C
= K1 (1-exp(-t/t1))
+ K2 (1-exp(-t/t2))
+ K3 (1-exp(-t/t3))
+ K4 (1-exp(-t/t4))
K1 = 4.05 E-04
K2 = 5.19 E-03
K3 = 1.63 E-02
K4 = 2.12 E-03
t
1
= 6.24 E-03
t
2
= 2.46 E-01
t
3
= 8.20
t
4
= 35.33
Thermal Resistance, Case to Sink Lubricated
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOK
www.pwrx.com Single SCR Isolated Module
1500 Amperes / Up to 1800 Volts
TM
Revision Date: 04/05/2011

Typical On-State Forward Voltage Drop
0
0.5
1
1.5
2
2.5
3
10 100 1000 10000 100000
Instantaneous On-State Current - It - Amperes
On-State Voltage - Vt - Volts
Maximum Transient Thermal Impedance
0.00
0.01
0.02
0.03
0.001 0.01 0.1 1 10 100
Thermal Impedance - Rjc - °C/W
0
180
360
CON DUCTION ANGLE
Maximum On-State Power Dissipation
0
200
400
600
800
1000
1200
1400
1600
1800
0 200 400 600 800 1000 1200 1400 1600
Average On-State Current - It(av) - Amperes
Max. Power Dissipation Per SCR - Watts_
0
180
360
CON DUCTION A NGLE
Maximum Allowable Case Temperature
80
90
100
110
120
130
0 200 400 600 800 1000 1200 1400 1600
Average On-State Current - It(av) - Amperes
Max. Case Temperature - Tcase -°C_
0
180
360
CON DUC TION A NGLE
Maximum On-State Power Dissipation
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500
Average On-State Current - It(av) - Amperes
Max. Power Dissipation Per SCR - Watts_
0
180
360
CON DUCTION ANGL E
Maximum Allowable Case Temperature
70
80
90
100
110
120
130
0 500 1000 1500 2000 2500
Average On-State Current - It(av) - Amperes
Max. Case Temperature - Tcase -°C_
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOK
www.pwrx.com Single SCR Isolated Module
1500 Amperes / Up to 1800 Volts
TM
Revision Date: 04/05/2011

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOK
www.pwrx.com Single SCR Isolated Module
1500 Amperes / Up to 1800 Volts
TM
Revision Date: 04/05/2011