C&H Technology Phawo-kS User Manual

6121 Baker Road, Suite 108 Minnetonka, MN 55345
www.chtechnology.com
Fax (952) 933-6223
1-800-274-4284
Thank you for downloading this document from C&H Technology, Inc.
Please contact the C&H Technology team for the following questions -
Technical
Application
Assembly
Availability
Pricing
Phone – 1-800-274-4284
E-Mail – sales@chtechnology.com
www.chtechnology.com - SPECIALISTS IN POWER ELECTRONIC COMPONENTS AND ASSEMBLIES - www.chtechnology.com
Phawo...kS..
Vishay ESTA
Medium Frequency Capacitors Water Cooled
ESTAfi lm®, SUBDIVIDED IN PARTIAL OUTPUTS, 150 - 10000Hz
DESIGN
All- lm winding in brass sheet welded casing;
Casing conductive, or grounded;
Casing varnish RAL 7033;
IP00, indoor;
Ambient temperature 1°C .... 50°C;
Out owing water temperature 40°C maximum;
Common terminal with 2 water-cooled current connections
M20;
Water tubing conductive;
A maximum of 8 partial outputs with connection bolts M12
or M20 (depending on application current);
Mounting in the upright or horizontal position;
Upon request, temperature or pressure monitoring;
x) thermostat
water inlet and outlet
cooling pipe
ø 12 x 1
rating plate
1
H
369
407
429
65
44
2 x ø 9.8
11 x 15
4 x 50
50
165
50
82.5
158
H
5
TYPE DESIGNATION
Ph a w o s 1 / 2650 / 0.5k S - . . .
frequency (kHz)
total output (kVAr)
voltage (V or kV)
live casing (grounded casing: no entry Phawo 750/...
NON-PCB
water-cooled
all fi lm dielectric
power capacitor
*) – ST = thermostat
DR = pressure switch
} Not all types available.
x) upon request
monitoring device *)
partial outputs
www.vishay.com 16
Document Number: 13057
Revision 28-Mar-02