CH Tech PX467S User Manual

Page 1
C&H Technologies, Inc. 445 Round Rock West Drive Round Rock, TX 78681-5012
(512) 733-2621
FAX (512) 733-2629 www.chtech.com
Outputs:
Front Panel
M-Module Trig A
M-Module Trig B
Divide-by-N Value (3 to 16383)
Clock Out Select
- Square Wave Output (N ÷ 2)
- Divide-By-2
- No divide (10MHz output)
- Divide-By-N
M-Trigger A/B Output Enable
Front Panel Output Enable
Front Panel Output Impedance
Front Panel Connector: SMA
Temperature:
Operating: 0°C to 50°C Storage: -40°C to 70°C
Power:
+5V (during warm-up) 0.9 A +5V (after warm-up) 0.65 A
CPCI/PXI Compliance
Complies with PCI spec. 2.0 R3.0 and PCI spec 2.2
5V and 3.3V signaling voltage (VIO) supported
5V only power supply
33MHz PCI data bus
Five trigger lines compliant with PXI Specification 2.1
Form Factor: Size 3U
Applications
Frequency or Time Reference
M-Module Triggering
Synchronization of data
acquisition hardware
Ordering Information
Part Number 11030260-0001
Additional Information
User Manuals can be found on our
website at www.chtech.com.
Specifications:
Ovenized Oscillator:
Nominal Frequency: 10MHz Stability (Freq. vs. Temp) ±0.01ppm Aging (Freq. vs. Time)
1st year ±0.1ppm
10 years ±1.0ppm Cal. (Freq. vs. Control) ±1.0ppm Warm Up (Freq. Ref. to 1 hr.)
5 minutes ±0.1ppm
30 minutes ±0.01ppm
Front panel accessible calibration 25-turn potentiometer provided for 10 year adjustability.
Pulse Output: (front panel)
High, IOH = -24mA 3.76V min. Low, IOL = 24mA 0.44V max.
Source/Sink ±50mA Rise/Fall (0.8 to 2.0V) 1.5ns Impedance (selectable) 3 or 50Ω
Pulse Width: 100ns*
* Pulse width is 50% of period when
“Square Wave Output” or “No divide” output is selected.
PX467S Precision Oscillator
The PX467S is a precision oscillator source that provides a highly accurate and stable clock reference that can be used as a frequency or time reference. Using selectable switches, the output of the on-board ovenized oscillator can be output as is or divided by any value from 2 to
16383. The resulting output can be directed to a front SMA connector and/or to selected PXI triggers. The output can be a 100ns pulse or a square wave.
This unit also features a position for adding one single wide M Module.
Loading...