Your Instant-Flow Micro water heater has no internal user serviceable parts and should be returned to the factory for
repair or replacement. Please contact factory for return authorization. If after following the Installation Instructions,
your Instant-Flow Micro does not heat water in accordance with this literature, please check the following:
1. Low Power - Verify your voltage by using a voltage meter. You should obtain your reading off the two outside
terminals located on the heater. Compare the reading against the voltage specified in the Installation Instructions.
The center terminal is always the earth ground.
2. Low Voltage -The percentage of reduction in voltage will result in a like reduction in temperature increase.
3. Check Low Amperage Draw - Check amperage draw using an Amperage Probe. Please compare your results
with the Installation Instructions (Table 1) to determine if the heater is operating correctly.
4. Length of Pipe - Length of pipe run will affect the temperature increase. The heater should be mounted no more
than 300mm-450mm from the point of use.
5. Check shut off valve - Check shut-off valve and make sure valve is open 100% to allow full water flow rate to
the heater.
6. Check Flow Rate - Controlling flow rate is essential to ensure proper temperature increase. Check your flow rate
to ensure proper operation of the heater.
7. Installation - Heater must be installed in a horizontal position. The silver label will then be located in the upper
left corner as you face the heater.
8. Water Supply - Use cold water only to supply the Instant-Flow Micro cold water inlet.
9. Freezing - Instant-Flow Micro heaters must be drained and stored if installed in a location subject to freezing.
Disconnect both inlet/outlet connections and blow air through the hot water outlet connection of the heater to
assist draining. Failure to completely remove water from the unit will result in freezing and cracking.
10. Problems? - Call our toll-free hotline at RBA Group 1300 788 778.
WARNING!
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• The water resistivity must not be less than 1100 Ohm. cm.
• The appliance must be earthed.
• The appliance is not to be installed in locations where freezing can occur.
• Means of disconnection must be incorporated in the fixed cabling in accordance with wiring rules.