Chronomite M-15L, M-30L, M-40L, M-20L, M-30 Installation And Operation Instructions Manual

...
ELECTRIC TANKLESS WATER HEATER - POINT OF USE
INSTANT-FLOW MICRO
®
WATER HEATER
INSTALLATION AND OPERATION INSTRUCTIONS (LOW ACTIVATION MODELS)
Chronomite Laboratories is a Member of Morris Group International™
TABLE OF CONTENTS
Technical Information
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
REQUIRED ITEMS FOR INSTALLATION NOT SUPPLIED
? Electrical Junction Supply Box ? Electrical Supply Conduit ? Electrical Supply Wire ? Dual Outlet Angle Stop
? 3/8” Flex Hose or 3/8” O.D. Tubing (2) ? Carpenters Level ? Flat Head Screwdriver ? Phillips Head Screwdriver
Acorn Engineering Company™ assumes no responsibility for use of void or superseded data. © Copyright Acorn Engineering, City of Industry, CA Member of Morris Group International. Please visit for most current specifications.
3100-003-001 II-927 06/17 REV 9
www.chronomite.com
COMPLIES WITH
Federal Public Law 111-380 (No Lead)
Member of
CHRONOMITE
Instantaneous
Water Heaters
17451 Hurley St.
City of Industry, CA
91744 U.S.A.
Phone 800-447-4962
w w w. ch r o n o m i t e . c o m
626-937-4270
MODEL VOLTAGE ACTIVATION .80 GPM [3.0 LPM] 1.0 GPM [3.8 LPM] 1.2 GPM [4.5 LPM]
M-15L 277 0.35 GPM [1.3 LPM] 35°F [20°C] 28°F [16°C] 24°F [13°C] M-20L 120 0.35 GPM [1.3 LPM] 20°F [11°C] - ­M-20L 208 0.35 GPM [1.3 LPM] 36°F [20°C] 28°F [16°C] 24°F [13°C] M-20L 240 0.35 GPM [1.3 LPM] 41°F [23°C] 33°F [18°C] 27°F [15°C] M-20L 277 0.35 GPM [1.3 LPM] 47°F [26°C] 38°F [21°C] 32°F [18°C] M-30L 120 0.35 GPM [1.3 LPM] 31°F [17°C] 25°F [14°C] 20°F [11°C] M-30L 208 0.35 GPM [1.3 LPM] 53°F [30°C] 43°F [24°C] 36°F [20°C] M-30L 240 0.35 GPM [1.3 LPM] 61°F [34°C] 49°F [27°C] 41°F [23°C] M-30L 277 0.35 GPM [1.3 LPM] 71°F [39°C] 57°F [32°C] 47°F [26°C] M-40L 208 0.35 GPM [1.3 LPM] 71°F [39°C] 57°F [32°C] 47°F [26°C] M-40L 240 0.35 GPM [1.3 LPM] 82°F [46°C] 66°F [36°C] 55°F [30°C]
INCOMING WATER TEMPURATURE INCREASE
MODE L WATTAGE VOL TAGE AMPS MODE L WATTAGE VOL TAGE AMPS
ELECTRIC TANKLESS WATER HEATER - POINT OF USE
®
Chronomite Laboratories is a Member of Morris Group International™
INSTANT-FLOW MICRO SPECIFICATIONS
(LOW ACTIVATION MODELS)
MICROPROCSSOR LIMITS TEMPERATURE INCREASE ACCORDING TO FACTORY SET TEMPERATURE.
BR EAKER S IZE BR EAKER S IZE
INTE RMITTENT
DU TY M-15 L 41 50 27 7 15 15 20 M-30 L 62 40 2 08 3 0 30 40 M-20 L 24 00 12 0 20 20 30 M-30 L 72 00 2 40 3 0 30 40 M-20 L 41 60 20 8 20 20 30 M-30 L 83 20 2 77 3 0 30 40 M-20 L 48 00 24 0 20 20 30 M-40 L 83 20 2 08 4 0 40 50 M-20 L 55 40 27 7 20 20 30 M-40 L 96 00 2 40 4 0 40 50 M-30 L 36 00 12 0 30 30 40
CONTIN U OUS
TABLE 1
DU TY
!
IMPORTANT
Before installation of heater, review electrical requirements needed for model of heater selected.
INTE RMITTENT
DU TY
CONTIN U OUS
DU TY
NOTE: BEFORE INSTALLATION, COMPARE ELECTRICAL NEEDED FOR THE MODEL OF HEATER SELECTED.
INSTANT-FLOW MICRO SPECIFICATIONS: DIMENSIONS: 6-1/4” [159 mm] X 9-5/8” [244 mm] X 2-3/4” [70 mm] WEIGHT: 5 LBS. [2.27 Kg] MATERIALS: ALUMINUM HOUSING, CELCON WATERWAYS, NICHROME PARTS COLOR: WHITE PIPE FITTINGS: 3/8” COMPRESSION OPERATING PRESSURE RATING: 25 PSI [172 kPa] MINIMUM, 80 PSI [551.6 kPa] MAXIMUM MAXIMUM PRESSURE RATING: 150 PSI [1034.2 kPa] NO PRESSURE RELIEF VALVE NEEDED
MAXIMUM OPERATING TEMP: 160°F [71°C] MINIMUM OPERATING FLOW RATE: 0.35 GPM [1.3 LPM] LISTINGS: UL, HUD, IAPMO, UPC, ETL
FACTORY SET TEMPERATURES:
104°F [40°C] 110°F [43.3°C] 120°F [48.9°C] Other temperature settings are available upon request up to160°F [71°C]. Temperature settings are not field adjustable. 110°F
[43.3°C] / 120°F [48.9°C] settings are recommended with cold water mixing faucets.
HOW INSTANT-FLOW MICRO WORKS
The engineered plastic case houses a series of ingeniously designed coils that instantly heat water as it flows through the vessel. A unique power switch automatically applies electrical current to the coils when hot water is requested. The electrical current is not applied when the water is not in use. The microprocessor is internally preset at the factory to maintain a constant output temperature with varying flow rates.
3100-003-001 II-927 06/17 REV 9
®
UNLESS REQUIRED BY LOCAL CODES.
®
CHRONOMITE TECHNICAL SUPPORT
TOLL FREE 800-447-4962 • LOCAL 626-937-4270 • FAX 626-937-4279
Page 2 of 8
ELECTRIC TANKLESS WATER HEATER - POINT OF USE
INSTANT-FLOW MICRO
®
DIMENSIONAL DATA
1
"
4
1
[6]
"
4
[6]
3
5
"
4
[146]
5
9
8
[244]
Chronomite Laboratories is a Member of Morris Group International™
"
7
Ø
"
32
[6]
2"
[51]
1
6
"
4
[159]
5
3
"
16
[84]
7
1
"
8
[48]
1
1
"
16
[27]
3100-003-001 II-927 06/17 REV 9
1
Ø1
"
16
[27]
1
[27]
1
10
"
8
[257]
TOLL FREE 800-447-4962 • LOCAL 626-937-4270 • FAX 626-937-4279
Page 3 of 8
CHRONOMITE TECHNICAL SUPPORT
16
3
2
"
4
[70]
1
"
Loading...