Chroma-Q CHSF2V12, CHSF2V12LR, CHSF2V12W, CHSF2V48, CHSF2V48LR User Manual

...
Chroma-Q
®
Studio Force II 12/ 48/ 72
User Manual
Version 1.0 June 2018, Software Version 1.4
Part Number: (CHSF2V12, CHSF2V12LR, CHSF2V12W)
(CHSF2V48, CHSF2V48LR, CHSF2V48W)
(CHSF2V72, CHSF2V72LR, CHSF2V72W)
Model: (652-1150, 652-1650, 652-1250) (641-4000, 641-4100, 641-4500) (641-5000, 641-5100, 641-5500)
www.chroma-q.com
i
Warranty Statement
Chroma-Q warrants to the original purchaser, with proof of purchase, that its delivered products shall be free from defects in material and workmanship under normal use for a period of 12 months from date of shipment.
Chroma-Q will repair, or at its option, provide an equivalent item or replace, the defective product during the stated warranty period. This warranty applies only to the repair or replacement of the product and only when the product is properly handled, installed and maintained according to Chroma-Q instructions. This warranty excludes defects resulting from improper handling, storage, installation, acts of God, fire, vandalism or civil disturbances. Purchaser must notify Chroma-Q in writing within 14 days of noticing the defect. This warranty excludes field labor or service charges related to the repair or replacement of the product.
The warranty contained herein shall not extend to any finished goods or spare parts from which any serial number has been removed or which have been damaged or rendered defective (a) as a result of normal wear and tear, willful or accidental damage, negligence, misuse or abuse; (b) due to water or moisture, lightning, windstorm, abnormal voltage, harmonic distortion, dust, dirt, corrosion or other external causes; (c) by operation outside the specifications contained in the user documentation; (d) by the use of spare parts not manufactured or sold by Chroma-Q or by the connection or integration of other equipment or software not approved by Chroma-Q unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above; (e) by modification, repair or service by anyone other than Chroma-Q, who has not applied for and been approved by Chroma-Q to do such modification, repair or service unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above; (f) due to procedures, deviating from procedures specified by Chroma-Q or (g) due to failure to store, install, test, commission, maintain, operate or use finished goods and spare parts in a safe and reasonable manner and in accordance with Chroma-Q’s instructions (h) by repair or replacement of engines without factory training.
The warranty contained herein shall not apply to finished goods or spare parts which are sold “as is”, as “second-hand”, as used”, as “demo” or under similar qualifications or to Consumables (“Consumables” is defined as any part(s) of goods or part(s) for use with goods, which part(s) of goods or part(s) for use with goods are consumed during the operation of the goods and which part(s) of goods or part(s) for use with goods require replacement from time to time by a user such as, but not limited to, light bulbs).
The warranty contained herein shall not apply, unless the total purchase price for the defective finished goods or spare parts has been paid by the due date for payment.
The warranty contained herein applies only to the original purchaser and are not assignable or transferable to any subsequent purchaser or end-user.
This warranty is subject to the shipment of the goods, within the warranty period, to the Chroma-Q warranty returns department, by the purchaser, at the purchasers expense. If no fault is found, Chroma-Q will charge the purchaser for the subsequent return of the goods.
Chroma-Q reserves the right to change the warranty period without prior notice and without incurring obligation and expressly disclaims all warranties not stated in this limited warranty.
www.chroma-q.com
ii
Disclaimer
The information contained herein is offered in good faith and is believed to be accurate. However, because conditions and methods of use of our products are beyond our control, this information should not be used in substitution for customer's tests to ensure that Chroma-Q products are safe, effective, and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent. Chroma-Q sole warranty is that the product will meet the sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted.
Chroma-Q reserves the right to change or make alteration to devices and their functionality without notice due to our ongoing research and development.
The Chroma-Q Studio Force II
TM
has been designed specifically for the lighting industry. Regular maintenance should be performed to ensure that the products perform well in the entertainment environment.
If you experience any difficulties with any Chroma-Q products please contact your selling dealer. If your selling dealer is unable to help please contact support@chroma-q.com. If the selling dealer is unable to satisfy your servicing needs, please contact the following, for full factory service:
Outside North America: North America: Tel: +44 (0)1494 446000 Tel: 416-255-9494 Fax: +44 (0)1494 461024 Fax: 416-255-3514 support@chroma-q.com support@chroma-q.com For further information please visit the Chroma-Q website at www.chroma-q.com. Chroma-Q and Studio Force IITM are trademarks, for more information on this visit
http://www.chroma-q.com/trademarks.asp. The rights and ownership of all trademarks are
recognized.
Important Notice: As per the requirements in the Occupational Safety and Health Administration standards for product approval, please refer to the OSHA web pages http://www.osha.gov/dts/otpca/nrtl/ for information on the list of Nationally Recognized Testing Laboratories (NRTLs) and the scope of recognition.
www.chroma-q.com
iii
Safety information
The following symbols are used to identify important safety information on the product and in this document:
Warning! Read the user manual before installing and operating the Chroma-Q Studio Force IITM. For future
reference, keep and use the manual. Safety precautions given in user manual must be followed at all times and the manuals of all the devices you connect it to. Observe all the warnings printed on product and in manuals. Make sure whoever is involved in working on or using the Chroma-Q Studio Force IITM has carefully read and understood all the safety precautions and listed warnings.
Install, connect, operate and service devices only as described in this manual and in
connected devices’ manuals and only in accordance with local laws and regulations. All Chroma-Q manuals are available for download from www.chroma-q.com.
Chroma-Q Studio Force II
TM
does not have user-serviceable parts. Refer any operation not
described in this manual to support@chroma-q.com.
If you experience difficulties with any Chroma-Q products please contact your local dealer. If your local dealer is unable to help then please contact support@chroma-q.com. If you are having trouble finding what you are looking for on our website, then contact our Chroma-Q marketing department by sending an email to marketing@chroma-q.com.
WARNING!
Read the safety precautions in this section before
installing, powering, operating or servicing this
product.
Warning! Safety Hazard. Risk of severe
injury or death.
S
Warning!
Hazardous
Voltage.
Risk of
severe lethal
electric
shock.
Warning!
Fire Hazard.
F
Warning!
Refer to User
manual.
S
www.chroma-q.com
iv
PROTECTION FROM ELECTRIC SHOCK
Use only the cables specified in this manual and on the Chroma-Q website at
www.chroma-q.com to interconnect devices in the installation. If the specified cables are
not long enough for an intended cable run, consult Chroma-Q for assistance in finding or creating a safe alternative solution.
Provide a means of locking out AC mains power that allows power to the installation to be shut down and made impossible to reapply, even accidentally, during work on the installation.
Shut down power to the installation during service and when it is not in use.
Before applying power to the installation, check that all power distribution equipment and
cables are in perfect condition and rated for the current requirements of all connected devices.
Isolate the installation from power immediately if any product, power cable or power plug is in any way damaged, defective or wet, or if it shows signs of overheating.
Do not immerse a Chroma-Q Studio Force IITM fixture in water or expose it to high- pressure water jets.
PROTECTION FROM BURNS AND FIRE
The Studio Force IITM is designed to be cooled by forced air convection. Provide free airflow around the fixture and a minimum clearance of 10 mm (0.4 in.) in all directions.
Do not operate the Studio Force IITM if the ambient operating temperature exceeds 40° C (104°F).
Do not modify the Studio Force IITM in any way not described in this manual or install other than genuine Chroma-Q parts. Use only accessories approved by Chroma-Q.
PROTECTION FROM INJURY
Ensure that the installation hardware and supporting surface or structure can hold at least 10 times the weight of all the devices they support.
Block access below the work area and work from a stable platform whenever installing, servicing or moving the Studio Force IITM.
As soon as work is completed, check that all hardware and components are securely fastened to supporting structures.
Make sure there are no flammable materials close to the product during operation.
Make sure the power cord is not crimped or damaged.
Avoid direct eye exposure to the light source while the product is on.
Never try to repair the product. Repairs carried out by unskilled people can lead to
damage or malfunction and/or invalidate your warranty. Please contact the nearest authorized dealer or contact support@chroma-q.com.
Keep this User Manual for future consultation. If this product is used by another user, be sure that they also receive this document.
www.chroma-q.com
1
Contents
www.chroma-q.com
2
www.chroma-q.com
3
Product overview
The Chroma-Q Studio Force IITM LED batten range is a powerful lineup of professional lighting industry. With up to 36,000/ Studio Force IITM 72, 24,000/ Studio Force IITM 48, 6,500/ Studio Force IITM 12 hot lumens output, these super bright fixtures are specifically designed for TV Broadcast and film applications but also performs particularly well in other situations demanding high quality tunable white light such as touring key lights, exhibitions, corporate events and theatre lighting.
Optional slide-in "Cyc Light" and "Border Light" optical lens accessories are available to adjust the light output to suit a wide range of applications.
The Chroma-Q Studio Force IITM lighting fixture is designed for professional indoor entertainment lighting. The fixture can be wall or floor mounted with the adjustable quick-release end-plate fixing system. For hung bar or truss mounting, additional bar clamp hardware is required.
The Studio Force IITM features integrated power supplies and can be operated as a stand-alone unit
or be remotely controlled through ANSI E1.11 USITT DMX 512-A protocol via a cable or a Lumen Radio wireless connection (when using the optional RF module).
The Studio Force IITM is available in three lengths, the Studio Force IITM V72 model which features a total of 24 high output cells (or pixels), the Studio Force IITM V48 model which features a total of 16
high output cells (or pixels) and the Studio Force II
TM
V12 model which features a total of 4 high output
cells (or pixels). Each cell provides a homogenized output with no unsightly color shadowing like fixtures
using traditional individual light emitters.
The control options incorporate a choice of KHi (Kelvin, Hue and intensity), Cine-Q (Intensity, Kelvin, Hue, Red, Green, Blue, White and Crossfade between KH and RGBW), RGBW (Red, Green, Blue, and White), RGB (Red, Green, and Blue), HSi (Hue, Saturation and intensity) and control modes.
An extra control parameter channel can be added to any of the modes, the channel will be placed as the last parameter of the fixture.
The product's robust extruded aluminum construction houses a discreet cable management system. Additional protection is built around the lenses for a truly road proof fixture.
www.chroma-q.com
4
Unpacking the units
The Studio Force II package includes the Studio Force II fixture, power cord, preinstalled mounting bracket and a Quick Start Guide. It is strongly recommended that original packaging is kept, for the ease of transportation.
Cabling
The Studio Force IITM utilizes Neutrik powerCON true1 connectors for power input and through connections. The DMX control data input and through connections are via two Neutrik XLR 5-pin male and female connectors. The chassis are ground bonded.
XLR-5 Pinout: Power and Data Input Location
Pin#
Function
1
Ground (Screen)
2
Data Minus
3
Data Plus
4
Spare Data Minus
5
Spare Data Plus
Table 1 (XLR PIN)
Power Cable Pinout:
International Colour Code
Connections
North American Colour Code
Connections
Green and Yellow
Earth (E)
Green
Ground (Green)
Blue
Neutral (N)
White
Neutral (Silver)
Brown
Live (L)
Black
Hot (Gold)
Table 2 (Power Cable Colour Code)
Important Notice:
The use of an optical splitter for DMX signal distribution is highly recommended when several fixtures are not plugged into the same power source.
Maximum Number of fixtures connected in a series:
Important Notice: Actual number of fixtures connected in series may be lower, based on your branch circuit
inrush rating.
Fixture
Wattage
@110V
@220V
SF II 72
800W
2 x SF II 72
4 x SF II 72
SF II 48
550W
3 x SF II 48
6 x SF II 48
SF II 12
150W
10 x SF II 12
20 x SF II 12
Table 3 (Fixtures in series)
Figure 1 (Connection)
www.chroma-q.com
5
Mounting
The Studio Force IITM fixtures are equipped with built-in mounting brackets or trunnions for floor mounting. The mounting brackets feature a pair of quick release levers for easy tilt adjustment. The hidden lever gives user quick access to unlock/lock the fixture tilt mechanism without using any tools and leaves the fixture side flat to place them next to each other without any gap. Wall and truss mounting applications may require additional hardware.
Figure 2 (SF-II 12 - Quick lever tilt adjustment)
Note: Secure the fixture with a safety bond. Fixing holes are provided in the endplates and fixture
brackets.
Optics
The Studio Force IITM fixtures are built with lenses that optimize the beam spread. The unit comes with preinstalled symmetric lenses for high intensity homogenized output and extremely uniform wash. The beam distribution is symmetrical when Studio Force II
TM
is used to directly illuminate an area on stage. The fixture
throws intense uniform white output at extreme intensity and provides a tight beam angle of 22o.
Figure 3 (Symmetrical Lens)
Cyc & Border Lens
“Cyc Lens” and “Border Lens” are slide-in optical accessories available to adjust the light output of the Studio Force IITM fixtures, to suit a wide range of applications. One accessory slot is provided on the front of the fixture to hold a slide-in lens accessory. Matching indentations on both ends of lens are provided for locking the lens in place.
Studio Force II comes standard with a 22º X 22º beam angle optics. 2 additional lenses can be position in front the standard optics. The output beam angle with Border Lens is 43o x 43o and with CYC Lens , 80ox35o. This can be seen in Figure 4 <<add proper reference for figure>>>
www.chroma-q.com
6
Figure 4 (Beam Angle)
Spring Plungers are pre-installed at the far ends of the accessory slot to lock in-place the slide-in panels. The height of the spring plungers is pre-set at the factory and requires no further adjustment.
Figure 5 (Optional slide-in lenses)
Control
Studio Force IITM fixture can operate as a stand-alone unit or can be controlled remotely via ANSI E1.11 USITT DMX 512-A protocol. The control function settings can be accessed through the touchscreen LCD display at the rear of the fixture.
Power-up Screen:
No Power Menu Access:
Insert a small blunt object, such as a paperclip, into the hole to turn the display ON and configure the fixture when it is not connected to the AC mains power.
Press and hold for 5 sec to
unlink from a Lumenradio RF transmitter
Figure 6 (Start-up Screen)
Tap on Focus button to turn
ON the fixture for 30 sec
Loading...