Chromalox PG442 User Manual

PG442
OCTOBER, 2003
161-025617-001
Type RBC-1 Radiant Heater
For Fixed Overhead Installations
© 2010 Chromalox, Inc.
Specifications – Table 1
Model Volts Watts Amperage BTU A Length B Width D Depth (Min.)
RBC-1101 120 1000 8.3 3412 RBC-1108 208 1000 4.8 3412 RBC-1102 240 1000 4.2 3412
27.125” 8.375” 3.5” 14 Ga
RBC-1107 277 1000 3.6 3412
(689 mm) (212 mm) (88.9)
RBC-11034 347 1000 2.9 3412 RBC-1151 120 1500 12.5 5118
RBC-1158 208 1500 7.2 5118
35.625”
RBC-1152 240 1500 6.3 5118
(905 mm)
8.375” 3.5” 14 Ga
RBC-1157 277 1500 5.4 5118
(212 mm) (88.9)
RBC-11534 347 1500 4.3 5118 RBC-1208 208 2000 9.6 6824
RBC-1202 240 2000 8.3 6824 46.625”
8.375” 3.5” 14 Ga
RBC-1207 277 2000 7.2 6824 (1184 mm)
(212 mm) (88.9)
RBC-12034 347 2000 5.8 6824 RBC-1258 208 2500 12.0 8530
RBC-1252 240 2500 10.4 8530 53.375”
8.375” 3.5” 14 Ga
RBC-1257 277 2500 9.0 8530 (1356 mm)
(212 mm) (88.9)
RBC-12534 347 2500 7.2 8530
Figure 1
With Optional Screen
Without Optional Screen
Ø1.125
SERVICE
ENTRANCE
OPENING
4X1/4" Ø MOUNTING HOLE FOR "S" HOOKS
1.000±.062
(3.500)
90˚
(8.375)
(4.500)
(10.000)
Ø.475
VIEW SHOWN WITH COVER REMOVED
("B")
("A")
The Chromalox RBC-1 radiant heater is shipped fully assem­bled. The heater can be hung from the ceiling by chains or rigid angle brackets attached to the heater brackets located on the back of the heater. (Chromalox offers hanging chain kits for these heaters that will allow for installations to 6 feet from the ceiling.) Minimum spacings:
Ceiling to top of heater is 3 in.
Wall to sides of heater is 12 in.
Floor to bottom of heater is 10 feet.
Installer should consult state and local codes and meet any applicable requirements regarding the installation.
GENERAL
IMPORTANT: SAVE THESE INSTRUCTIONS
FIRE HAZARD. Do not use as a residential or household heater. Keep combustible material away from heater. Do not operate heater where flamma­ble vapors, gases or liquids are present.
To avoid personal injury read “IMPORTANT INSTRUCTIONS” on this page before installation or operation of heater.
INSTALLATION
Min.
Min.
Min.
Min.
2
Figure 3
Figure 2
3
WIRING
ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property dam­age. Heater must be effectively grounded in accor­dance with the National Electrical Code, NFPA 70.
All electrical wiring must be done by a qualified person in accordance with National Electrical Code (NEC) and meet all state and local regulations.
1. Use heater only at the voltage specified on the nameplate.
2. Branch circuit wire for connection to heater must be at least
90°C wire. Use copper conductors only.
3. The heater connection points are located in the gasketed termi-
nal enclosure. To remove cover, remove 4 screws on the cover. Remove the cover to expose wiring connection points.
4. A green ground terminal is provided in the bottom of the enclo-
sure. The ground wire should be connected before other con­nections are made.
5. Refer to Table 1 for proper entrance wiring size.
6. Heater can be wired with rigid or flexible conduit.
Grill Kit Selection Guide
Model Volts Watts Optional Grill Kit
RBC-1101 120 1000 RBC-1108 208 1000 RBC-1102 240 1000 168-053169-085 RBC-1107 277 1000 RBC-11034 347 1000
RBC-1151 120 1500 RBC-1158 208 1500 RBC-1152 240 1500 68-053169-086 RBC-1157 277 1500 RBC-11534 347 1500
RBC-1208 208 2000 RBC-1202 240 2000
68-053169-087
RBC-1207 277 2000 RBC-12034 347 2000
RBC-1258 208 2500 RBC-1252 240 2500
68-053169-088
RBC-1257 277 2500 RBC-12534 347 2500
MAINTENANCE
ELECTRIC SHOCK HAZARD. Disconnect all power before servicing or replacing heating elements.
The reflectors should be kept clean to obtain the maximum
radiant output.
Element Replacement
1. Remove Terminal Box Cover.
2. Disconnect lead wires from heater terminals and disengage box
from conduit /cable fitting.
3. Remove safety grills (if installed).
4. Loosen (2) 3/8” nuts from the terminal box bracket located on
the back of the heater and slide the entire heating element assembly out of the reflector assembly.
5. Remove bulkhead fitting nut and washers.
6. Remove failed element and replace with a new element.
7. Place gasket on the bulkhead fitting and insert terminals and fit-
ting into the element hole in the terminal box.
8. Place washer and nut on the bulkhead fitting and tighten.
9. Reassemble by following the reverse procedures (steps 4
through 1)
Replacement Parts
Model Volts Watts Element
RBC-1101 120 1000 322-074905-143 RBC-1108 208 1000 322-074905-144 RBC-1102 240 1000 322-074905-145 RBC-1107 277 1000 322-074905-146 RBC-11034 347 1000 322-074905-147
RBC-1151 120 1500 322-074905-148 RBC-1158 208 1500 322-074905-149 RBC-1152 240 1500 322-074905-150 RBC-1157 277 1500 322-074905-151 RBC-11534 347 1500 322-074905-152
RBC-1208 208 2000 322-074905-153 RBC-1202 240 2000 322-074905-154 RBC-1207 277 2000 322-074905-155 RBC-12034 347 2000 322-074905-156
RBC-1258 208 2500 322-074905-157 RBC-1252 240 2500 322-074905-158 RBC-1257 277 2500 322-074905-159 RBC-12534 347 2500 322-074905-160
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce risk of fire, electric shock and injury to persons, including the following:
1. Read all instructions before using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as
furniture and papers at least 7 feet from the front of the heater.
3. Always disconnect heater when not in use.
4. Do not use outdoors.
5. Connect to properly grounded outlets or building ground.
6. This heater has hot surfaces. Do not use it in areas where gaso-
line, paint or flammable liquids are used or stored.
7. Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric shock or injury to persons.
8. In order to prevent equipment damage, protect with a ground
fault device such as Chromalox STAR-GF series monitor.
9.
SAVE THESE INSTRUCTIONS
2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com
Limited Warranty:
Please refer to the Chromalox limited warranty applicable to this product at
http://www.chromalox.com/customer-service/policies/termsofsale.aspx.
Loading...