Chromalox Flanged immersion heaters Terminal Enclosures

Immersion
Flanged Immersion Heaters
Terminal Enclosures
Enclosure Styles and Dimensions (Inches)
3-1/2"
6-3/4"
Dimple for locating chassis punched
conduit opening(s)
Removable Service Entrance Plate
263
10-3/8
flanged
E1 — General Purpose, for up to 5" Flange
Dimple for locating chassis punched
conduit opening(s)
267
Removable Service Entrance Plate
E4 — Moisture Resistant Enclosure with Gasket 6" and Larger
1"ConduitOutlet
E1 — General Purpose, for 6" and Larger Flange
1"ConduitOutlet
3-3/4"
1-1/2"
5
E4 — Moisture Resistant Enclosure with Gasket up to 5" Flange
3-3/4"
1-1/2"
5
E2 — Explosion Resistant Enclosure up to 5" Flange
Conduit
Hub
E2 — Explosion Resistant Enclosure for 6" and Larger Flange
B-91
Immersion
Flanged Immersion Heaters
Terminal Enclosures
Third Party Specifications by Housing Style
Model Purpose
E1 General Purpose Generic
E4* Moisture Resistant
E2 Moisture Resistant/
E5
Flange
8"-12"
12"-18"
* WARNING: Addition of sparking devices such as a Thermostat to an E4 housing will annul hazardous area rating.
Note: Temps over
T3 (200°C) require standoffs for third party listing. Refer to IECex & ATEX certifs. for standoff dimensions
Explosion Proof Ex de IIB+H2 T1 to T6, 540°C, 600°C Note: Temps over
T4 (135°C) require standoffs for third party listing. Refer to IECex & ATEX certifs. for standoff dimensions
Moisture Resistant/ Explosion Proof
Size
Ex de IIC T1 to T6
3"-8"
540°C, 600°C
ATEX IIC Labeling Reference CFP, CFP2, CFP4, CFP8, CFP12, CFP20 Refer to European Catalog.
Agency (s)
Ratings General Duty Only General Duty Only General Duty Only General Duty Only
Generic
Agency (s)
Ratings Class I Div. 2,
Generic
Agency (s)
Ratings Class I, Div. 1
Generic
Agency (s)
Ratings II 2 G EEx de IIC T1 to
Designation(s)
NEMA 1, NEC UL/CSAus
NEMA 4 UL / CSAus
Groups B, C, D Groups E, F: 200°C (T3) Group G 165°C (T3B) Class I Zone 2 AEx nA II T1 to T6
CSAus CSA ATEX IECex
Groups B,C & D Class II, Div. 1 Groups E, F & G Class I Zone 1 AEx d IIB + H2 T1 to T6
North American
Canadian
Designation(s)
NEMA 1 IP32 CSA
NEMA 4 CSA
Class I Div. 2, Groups B, C, D Class II Division 2, Groups E, F: 200°C (T3) Group G 165°C (T3B) Class I Zone 2 Ex nA II T1 to T6
Class I, Div. 1 Groups B,C &D Class II, Div. 1 Groups E, F & G Class I Zone 1 Ex d IIB + H2 T1 to T6
European
Designation(s)
IP32
CE: Manufacturer’s
Declaration
IP66
CE: Manufacturer’s
Declaration
II 3 G Ex nA II T1 to T6 Ex nA II T1 to T6
I 2 G EEx d IIB+H2 T1 to T6
ITS ATEX
T6, 540°C, 600°C
International
Designation(s)
CE: Manufacturer’s
Declaration
IP66
CE: Manufacturer’s
Declaration
Ex d IIB+H2 T1 to T6
IECex
Ex de IIC T1 to T6 540°C, 600°C
B-92