Chromalox EDU-01, EDU-02, EDU-03, EDU-04, EDU-05 User Manual

...
Chromalo
Load Bank Energy Dissipation Units
Chromalox
®
Load Bank Energy Dissipation Units
Description
Chromalox load banks provide durable, precise energy control for applications requiring anywhere from 1 kW of power to multi-megawatt capacity. All units are subjected to a high­voltage flash test, an insulation resistance check, and a simulated load test. Chromalox load bank energy dissipation units hold resistances within ±5 percent of hot operating resistance. The units are fabricated from weatherproof stainless steel for durability and feature overtem­perature protection with fan interlock. Thermally protected fan motors are easily accessible. Electrical connections and components are protected by hinged, lockable doors or bolt-on panels, depending on unit type.
Applications
Factory or field testing diesel generators
Braking resistors for traction or inverter drives
Base loading of remote or standby power plants
Load Bank Dimensions and Weight
Model
Number
Length Width Height lb
Approx.
Weight
Dimensions
(in.)
EDU-01 100 45 34 26 450 EDU-02 200 47 41 33 550 EDU-03 300 49 45 41 890 EDU-04 400 55 45 65 1,110 EDU-05 500 55 49 73 1,215 EDU-06 600 51 65 71 1,775 EDU-08 800 79 69 83 2,000 EDU-10 1,000 79 69 83 2,210
Battery discharge testing
UPS testing
Marine applications
EDU-100 standard model.
kW
®
x
Standard Options
In addition to these standard options, our engineers will be glad to discuss adding any features not listed below.
Remote Control
Control keypad on a 25 m cable enables load appli­cation from inside generator room.
Master-and-Slave Configuration
Links up to 10 load banks
of any size together to
form a much larger total load. Individual load banks can still be used discretely, each retaining its 1 kW switching resolution. This is ideal for applica­tions where multiple,
small loads are tested
but a single large load may
need testing periodically.
Designs for Special Voltages, Multiple Voltages, and Various Frequencies
Designed for voltages from 12 Vdc to 780 Vac or Vdc. Chromalox load banks can also accommodate most voltage combinations within a single load frame. Units are available for dc, 50 or 60 Hz ac, and 400 Hz ac frequencies.
Benefits
Construction
The stainless steel construction of a Chromalox load bank provides strength and corrosion-resistance. Alloy steel sheathed tubular heating elements stand up to harsh weather, including heavy rain. And all electrical enclosures are protected to IP54 require­ments (NEMA 3R).
Single or multiple self-powered fans provide cooling airflow to hold outer skin temperature within safe lim­its. Units up to and including 500 kW are designed for horizontal air­flow, while larger units, up to 1,000 kW, utilize a vertical airflow.
For applications requiring mobility, Chromalox fits units up to and including 500 kW with casters for easy position­ing on smooth floors. Larger units are skid-mounted for easy transportation.
Controls
Chromalox load banks are controlled by a multi­stage, contactor-based system that is an integral part of the load frame. The controls are painstak­ingly engineered to provide the utmost precision and protection:
Easy-to-use keypad enables operator to enter the load before pressing an "enter" key to actuate the contactors.
Loads can be progressively applied in 1 kW incre­ments up to full load, preventing spikes.
Load spikes can be induced if the test requires.
High limit controls for temperature and low limit controls for airflow helps ensure protection from damage due to incorrect use.
Can be UL-listed for U.S. market or CE­marked for European markets.
Hand-portable 128 kW dc load bank for low-power UPS or Telecoms testing.
Trailer-mounted EDU-100T portable load bank used for field-testing and commissioning generators.
IP
Construction Materials for Special Applications and Hazardous Areas
Special construction materials can be used to suit applications like small hand-held portables or salt water environments. Chromalox load banks can also be designed and manufactured for hazardous areas.
A Full Range of Instrumentation
Whether the application requires a simple status display box or data log and download capability, Chromalox has the right load bank instrumentation solution.
Alternative Cooling Systems
Water-cooled units can be produced that are ideal for shipboard applications. Units are available with­out fans for engine radiator mounting.
Stainless steel construction ensures toughness and corrosion-resistance.
Enclosures protect to IP54 (NEMA 3R) standards.
Easy-to-use keypad interface minimize operator error.
Load controllers change load in 1 kW increments without moving back to zero, preventing constant spikes.
Fan units designed to keep outer skin temperature within safe limits.
Industrial casters provide for easy movement on smooth floors (available on units up to 500 kW).
Containerized 3.5 mW load bank.
EDU-400 standard model.
103 Gamma Drive Ext. Pittsburgh, PA 15238 USA
Phone: (412) 967-3800 Fax: (412) 967-5148
Toll-Free: 1-800-443-2640
email: sales@chromalox.com www.chromalox.com
Chromalo
x
®
PRECISION HEAT AND CONTROL
© 2002, 2004 Chromalox, Inc.
Eltron Chromalox
Eltron House 20-28 Whitehorse Road Croydon, Surrey, CR9 2NA, UK
Tel: +44 (0)20 8665 8900 Fax: +44 (0)20 8689 0571
email: uksales@chromalox.com www.chromalox.co.uk
Etirex Chromalox
Route de Château-Thierry Noyant et Aconin F-02203 SOISSONS Cedex, France
Tel: +33 (0)3 23 74 39 39 Fax: +33 (0)3 23 74 39 00
email: etirexchromalox@wanadoo.fr www.chromalox.fr
Ordering Information for Standard Load Banks
Model
EDU Load Bank Energy Dissipation Unit
EDU 06 3 2 KE 8 Typical Model Number
Code Power/Kilowatt rating
01 100 kW 02 200 kW 03 300 kW 04 400 kW 05 500 kW 06 600 kW 08 800 kW 10 1000 kW
Code Steps
1 1 kW 2 10 kW
Code Mounting
1 Caster Mounted 2 Skid Mounted 3 Trailer Mounted
Code Load Switching Scheme
TG Toggle selector switches PB Push buttons KE Keypad mounted on unit RE Remote control with cord
Code Voltage
1 120 Vac 2 208 Vac 3 208/240 Vac 4 240 Vac 5 240/480 Vac 6 277 Vac 7 380 Vac 8 480 Vac
Code Options
A Multifunction Digital Readout Meter B Single-Volt Meter with Phase Selection Switch C Three-Volt Meters D Single Ammeter with Phase Selection Switch E 3 Ammeters F kW Meter G Control Panel Cooling Fan
Other combinations are available upon request.
PDS LB
Code Options
H Anticondensation Heater
I Load Management Module for 5MW
J Remote Control with 25ft. Cord K Wrong Voltage Indication L Camlock Power Connections
M Phase Reversal Switch
N Fan Delay Switch
Loading...