Chromalox CAF-20430, CAF-20645, CAF-20660, CAF-20550, CAF-20215 User Manual

...
(Supersedes PF423-1)
PF494-1
AC
161-506173-001
4
and
Installation, Operation
JULY, 2002
(Supersedes PF494)
CAF-20 Series Architectural Cabinet
Convection Heater
© 2010 Chromalox, Inc.
TABLE 1Specifications
Model VoltsPhase Watts Amps BTUH Length Weight (Lbs.)
CAF-20215 208 1 1,500 7.2 5,118 24.3 32 CAF-20215 208 3 1,500 4.2 5,118 24.3 32 CAF-20215 240 1 1,500 6.3 5,118 24.3 32 CAF-20215 240 3 1,500 3.6 5,118 24.3 32 CAF-20215 277 1 1,500 5.4 5,118 24.3 32 CAF-20215 480 1 1,500 3.1 5,118 24.3 32 CAF-20215 480 3 1,500 1.8 5,118 24.3 32 CAF-20220 208 1 2,000 9.6 6,824 24.3 32 CAF-20220 208 3 2,000 5.6 6,824 24.3 32 CAF-20220 240 1 2,000 8.3 6,824 24.3 32 CAF-20220 240 3 2,000 4.8 6,824 24.3 32 CAF-20220 277 1 2,000 7.2 6,824 24.3 32 CAF-20220 480 1 2,000 4.2 6,824 24.3 32 CAF-20220 480 3 2,000 2.4 6,824 24.3 32 CAF-20330 208 1 3,000 14.4 10,236 36.3 43.5 CAF-20330 208 3 3,000 8.3 10,236 36.3 43.5 CAF-20330 240 1 3,000 12.5 10,236 36.3 43.5 CAF-20330 240 3 3,000 7.2 10,236 36.3 43.5 CAF-20330 277 1 3,000 10.8 10,236 36.3 43.5 CAF-20330 480 1 3,000 6.3 10,236 36.3 43.5 CAF-20330 480 3 3,000 3.6 10,236 36.3 43.5 CAF-20430 208 1 3,000 14.4 10,236 48.3 53 CAF-20430 208 3 3,000 8.3 10,236 48.3 53 CAF-20430 240 1 3,000 12.5 10,236 48.3 53 CAF-20430 240 3 3,000 7.2 10,236 48.3 53 CAF-20430 277 1 3,000 10.8 10,236 48.3 53 CAF-20430 480 1 3,000 6.3 10,236 48.3 53 CAF-20430 480 3 3,000 3.6 10,236 48.3 53 CAF-20440 208 1 4,000 19.2 13,648 48.3 53 CAF-20440 208 3 4,000 11.1 13,648 48.3 53 CAF-20440 240 1 4,000 16.7 13,648 48.3 53 CAF-20440 240 3 4,000 9.6 13,648 48.3 53 CAF-20440 277 1 4,000 14.4 13,648 48.3 53 CAF-20440 480 1 4,000 8.3 13,648 48.3 53 CAF-20440 480 3 4,000 4.8 13,648 48.3 53 CAF-20645 208 1 4,500 21.6 15,354 72.3 74 CAF-20645 208 3 4,500 12.5 15,354 72.3 74 CAF-20645 240 1 4,500 18.8 15,354 72.3 74 CAF-20645 240 3 4,500 10.8 15,354 72.3 74 CAF-20645 277 1 4,500 16.2 15,354 72.3 74 CAF-20645 480 1 4,500 9.4 15,354 72.3 74 CAF-20645 480 3 4,500 5.4 15,354 72.3 74 CAF-20550 208 1 5,000 24 17,060 60.3 63.5 CAF-20550 208 3 5,000 13.9 17,060 60.3 63.5 CAF-20550 240 1 5,000 20.8 17,060 60.3 63.5 CAF-20550 240 3 5,000 12 17,060 60.3 63.5 CAF-20550 277 1 5,000 18.1 17,060 60.3 63.5 CAF-20550 480 1 5,000 10.4 17,060 60.3 63.5 CAF-20550 480 3 5,000 6 17,060 60.3 63.5 CAF-20660 208 1 6,000 28.8 20,472 72.3 74 CAF-20660 208 3 6,000 16.7 20,472 72.3 74 CAF-20660 240 1 6,000 25 20,472 72.3 74 CAF-20660 240 3 6,000 14.5 20,472 72.3 74 CAF-20660 277 1 6,000 21.7 20,472 72.3 74 CAF-20660 480 1 6,000 12.5 20,472 72.3 74 CAF-20660 480 3 6,000 7.2 20,472 72.3 74
Length
1-1/2
2
Back View
Bottom View
(Front Inlet Version Shown)
2-3/4
Terminal Box
Terminal Box
20
1
1
5-3/4
Side View
(Less End Cap)
Figure 1
MODEL NUMBER DESCRIPTION
WARNING: Hazard of Electric Shock. Disconnect all
power before installing heater.
WARNING: Hazard of Electric Shock. Any installa­tion involving electric heaters must be effectively grounded in accordance with the National Electrical Code to eliminate shock hazard.
WARNING: Hazard of Fire.
1. Do not install heaters against any highly com­bustible surfaces such as low density cellulose fibre.
2. Do not locate heater below electrical conve­nience receptacles.
3. Do not store or use gasoline or flammable liq­uids in the vicinity of the heaters.
WARNING: Hazard of Fire. Keep electrical cords, drapes, rugs and other furnishings away from the heater. The normal operating temperatures of cab­inet convectors are relatively high. Proper opera­tion requires free circulation of room air through the heating element.
Installation Wall
1. Unpack the heater from the carton and remove the front panel. Note: The front panel screws are recessed at the bottom of the
top front panel at each end of the heater. (Figure 2) Remove top front panel by pulling down to disengage from top of heater. To remove the bottom front panel, remove screws as shown in Figure 3. Pull bottom front panel by pulling upward to disen­gage from bottom of heater.
2. Remove the desired terminal box covers and wire supply knockouts from the terminal box area.
3. Determine the correct mounting height, and scribe or snap a level line on the wall to maintain each heater back plate in a horizontal alignment, when mounting.
4. Mount the back plate to the wall using suitable fasteners (pro­vided by customer) using the scribed line on the wall to keep the heater level. TIP: Should the wall surface be uneven, secure the heater back panel to the high spots. This will avoid a distorted appearance.
5. Proceed to the wiring instructions.
Recessed Wall Note: The use of a ALTB Trim kit is strongly recommended when
recessing the heater.
A recess opening dimension of 20-1/2” high and the length of the heater is required to install this heater. The heater may be recessed up to a depth of 5-5/8”.
INSTALLATION
Top Panel Screws
CAF-20 2 20 21 01 A9
Code Control Options (Factory Installed)
A9 = Built-in DP tamperproof hydraulic thermostat 208 - 480V A3 = Built-in 3P tamperproof hydraulic thermostat for 3P voltages 208 - 480V A4 = Built-in 24V low voltage relay for 1P voltages 208 - 480V A5 = Built-in 24V low voltage relay and transformer for 1P voltages 208 - 480V A6 = Built-in 24V contactor for 3P voltages 208 - 480V A7 = Built-in 24V contactor and transformer for 3P voltages 208 - 480V
Painted Anodized
68 = Almond 07 = Bronze 02 = White 10 = Clear
Code Voltage/Phase
21 = 208/1 23 = 208/3 31 = 240/1 41 = 277/1 73 = 480/3
Code Wattage (See Table)
Code Length
2 = 2 ft. 3 = 3 ft. 4 = 4 ft. 5 = 5 ft. 6 = 6 ft.
Type
Architectural Cabinet Convection Heater
TABLE 2
Bottom Panel Screws
Figure 2
Figure 3