HSM02 DOOR/WINDOW DETECTOR
The Door/Window Detector is a Z-Wave with any Z-Wave Z-Wave
TM
logo can also be used with it regardless of the manufacturer, and ours
TM
enabled network. Z-WaveTM enabled devices displaying the
can also be used in other manufacturer’s Z-Wave of this Door/Window Detector on other manufacturer’s Wireless Controller menu allows remote turn-on of connected modules and their connected lighting when the Detector is triggered.
TM
enabled device and is fully compatible
TM
enabled networks. Inclusion
Trough association, device can be assigned as master/slave, and specify which slave is going to be controlled by which master.
Reset Restore Detector to factory default.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-Wave
TM
Certificated Primary Controller to access
the setup function, and to include/exclude/associate devices.
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the unit.
Inclusion
Exclusion
Reset
1. Have Z-Wave Controller entered inclusion mode.
2. Pressing tamper switch three times within 1.5 second will enter inclusion mode.
1. Have Z-Wave Controller entered exclusion mode.
2. Pressing tamper switch three times within 1.5 second will enter exclusion mode.
1. Press tamper switch three times within 1.5 second.
2-second on, 2-second off
LED lights up once whenever tamper switch is pressed once.
Include to or Exclude from a Z-WaveTM Network
In the rear casing, there is a tamper switch which is used to carry out inclusion, exclusion or reset. When power is first applied, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices. The Detector will stay “awake” for 5 minutes when power is first applied to allow time for configuration. Please get familiar with the terms below before starting the operations.
Function Description
Inclusion Add a Z-Wave enabled device (e.g. Detector) to Z-Wave network. Exclusion Delete a Z-Wave enabled device (e.g. Detector) from the network. Association After inclusion, you have to define the relationshipbetween devices.
2. Within 1 second, press and hold the tamper switch until LED is off.
3. IDs are excluded and all of preset value will be reset to factory default.
1. Have Z-Wave Controller entered association mode.
2. When pressing tamper switch three times within 1.5 second, the unit will emit the NIF which implies that the unit has entered association mode.
LED keeps on before reset function has been completed. 2-second on, 2-second off
Association
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be v iewed from the Z-Wave
Controller.
1
Choosing A Mounting Location
The Door/Window Detector is suitable for mounting in dry interior locations only. Decide which doors/windows are to be protected by Door/Window Detectors,
(usually the front and back doors as a minimum will have Door/Window Detectors fitted). Additional detectors may also be fitted where required to other vulnerable doors or windows, (e.g. garage, patio/conservatory doors etc).
Note: Take care when fixing the Detect or to a met al frame, or mou nting within 1m of metalwork (i.e. radiators, water pipes, etc) as this could affect th e radio range of the device. If required, it may be necessary to space the magnet and detector away from the metal surface using a plastic or wooden spacer to achieve the necessary radio range.
Installation
1. Ensure that the system properly powered. Factory default built in a CR2450 battery inside the detector and uses a Mylar film to isolate battery from electric circuit of the detector. Remove the battery Mylar film when ready to let the detector work. If there is no battery inside the detector or need to replace a new battery please insert the battery in 45° angle as below figure
2. Using the adhesive tape to fit detector on the door or window.
3. Fit the magnet to the moving part of the door/window opposite the detector using the adhesive tape.
4. Ensure that the parallel gap between the magnet and detector is less than 20mm and that the matching line on the magnet is pointing towards and aligned with the line on the detector. An alarm condition will be occurred if the gap is greater than 35mm.
5. Remove the battery cover with the tamper switch not being pressed on the detector (test mode), detach or close the magnet from the Detector, the LED on the detector will illuminate.
6. After proper installation and test, put the battery cover back to the detector and the detector enters the normal mode.
Note: After removing batteries, wait for 5 seconds to refit batteries.
Operation
1. The unit will stay “awake” for 5 minutes when power is first supplied to allow time for configuration.
2. After the unit stays in sleep status, it can be woken up by pressing the tamper switch continuously until the LED lights up once. The unit will enter sleep status again after 10 seconds. If longer awake is desired, press tamper switch three times within 1.5 seconds will prolong its awake period to 5 minutes.
3. With the tamper switch not being pressed, the unit enters test mode, which
allows the user to make a test. Detach the magnet from the Detector, the red indicator LED on the Detector will illuminate.
4. When the tamper switch is pressed, the unit enters normal mode and the red
indicator LED on the Detector will not illuminate to conserve battery life when the detector is triggered, (unless the battery is low).
2