The RDK-1 Downspout Hanger Kit is used to suspend and prevent damage to Chromalox Roof and Gutter Heating Cable as it enters gutter downspout. This kit contains material for one downspout entrance.
RDK-1 Downspout Hanger Kit
INSTALLATION
ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heating cable and accessories. A qualified person must perform installation and service of heating cable and accessories. Heating cable must be effectively grounded in accordance with the National Electrical Code. Failure to comply can result in personal injury or property damage.
Note: All electrical wiring, including GFCI (Ground Fault Circuit Interrupters), must be done according to National Electrical or local codes by a qualified person.
1. Place the split grommet around the heating cable where the
downspout hanger will be placed.
2. The wire hanger has a 180˚ hairpin bend at one end and a loop
bend at the other end. Center the hairpin end of the wire hang­er along the grommet. Slide the clamp over the wire hanger and into the bend of the hanger.
3. Tighten the clamp until the hanger and cable are firmly held in
place.
Figure 1
Figure 2
Figure 3
Clamp
Split Grommet
Hanger
1347 HEIL QUAKER BLVD., LAVERGNE, TN 37086 Phone: (615) 793-3900 www.chromalox.com
INSTALLATION
4. Attach the hanger assembly to the roof by driving a roofing
nail or screw through the looped end of the hanger.
Gutter
Downspout
Figure 4
Limited Warranty:
Please refer to the Chromalox limited warranty applicable to this product at
http://www.chromalox.com/customer-service/policies/termsofsale.aspx.