Chroma Color Block PSU-30 Quick Start Manual

Color Block PSU-30 Quick Start Guide V1.0 Color Block PSU-30 Quick Start Guide V1.0 PN: 602-0505
Approvals & Disclaimer
The information contained herein is offered in good faith and is believed to be accurate. However, because conditions and methods of use of our products are beyond our control, this information should not be used in substitution for customer's tests to ensure that Chroma-Q products are safe, effective, and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent. Chroma-Q sole warranty is that the product will meet the Chroma-Q sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted.
Chroma-Q reserves the right to change or make alteration to devices and their functionality without notice due to on-going research and development.
The Chroma-Q Color Block PSU-30 has been designed specifically for the professional entertainment lighting industry. Regular maintenance should be performed to ensure that the products perform well in the entertainment environment.
If you experience any difficulties with any Chroma-Q products please contact your selling dealer. If your selling dealer is unable to help please contact support@chroma-q.com. If the selling dealer is unable to satisfy your servicing needs, please contact the following for full factory service:
Outside North America:::: North America:::: Tel: +44 (0)1494 446000 Tel: +1 416-255-9494 Fax: +44 (0)1494 461024 Fax: +1 416-255-3514 support@chroma-q.com support@chroma-q.com
For further information please visit the Chroma-Q website at www.chroma-q.com.
Chroma-Q is a trademark, for more information on this visit www.chroma-q.com/trademarks.
The rights and ownership of all trademarks are recognised.
Quick Start Guide
Color Block™ PSU-30
For a full product manual please visit www.ac-et.com
Color Block PSU-30 Quick Start Guide V1.0 Color Block PSU-30 Quick Start Guide V1.0
1. Overview
The Color Block PSU-30 is a 2U 19” rack mounted unit that supplies power and data to a maximum of 30 Color Block DB4 or Color Block 2 LED fixtures through 6 XLR4 outputs. It can be controlled in 16 modes via ANSI E1.11 USITT DMX 512-A, or can operate independently as a standalone system. For the purpose of clarification, the Color Block DB4 is a fixture that contains 4 cells, with each cell comprising of 3 LEDs; the Color Block 2 is a fixture that contains 48 high output LEDs set into 12 single-optic RGBA clusters that are grouped into 4 cells. Note: To ensure proper functionality, Date/Time must be set before operation. Look Store will function when Date/Time are set. Time is reset when battery is replaced or when the PSU-05B is reset.
2. Cabling
1. Install the proper male connector to the trailing lead and connect power with input of 100-240V, 50-60 Hz.
2. Connect input data ANSI E1.11 USITT 512-A from an external source or lighting control console through a male XLR-5. A pass through connection is available on the female XLR-5.
3. Connect power and output data through 6 individual female XLR-4 to the Color Block DB4 or Color Block 2 fixtures. A maximum of five daisy-chained Color Block fixtures can be connected to each XLR4 output. Return lines are not required but the total length of each chain must not exceed 60m/~200ft.
Note:
: :
: See diagram in full User Manual.
3. Control Menu
The control menu items are accessed via the LCD display with the following controls:
Right hand button (red) = Enter (hold for 2 seconds to save)
Left hand button (blue) = Exit without saving
Wheel = Adjusts values or scrolls through menu items
Menu Options Function
DMX Address
To set DMX start address, press Enter, turn wheel to adjust DMX start address, press Enter for 2 seconds to save
Control Mode
There are 10 DMX controlled modes for the Color Block DB4 system (CB1) and 16 DMX controlled modes for the Color Block 2 system (CB2). Go to “System” and select either “CB1” or “CB2”. There are 3 grouping options (Individual, Block, All) with 3 control options for each (FX, HSI and RGB):
Mode Ch Group System: CB1 System: CB2 1 67 Variable 7FX + 20xHSI 7FX + 20xHSI 2 60 Cell 20xHSI 20xHSI 3 60 Cell 20xRGB(w/ *Magic Amber) 20xRGB(w/ *Magic Amber) 4 21 Block 6FX + 5xHSI 6FX + 5xHSI 5 15 Block 5xHSI 5xHSI 6 15 Block 5xRGB(w/ *Magic Amber) 5xRGB(w/ *Magic Amber) 7 9 All 6FX + HSI 6FX + HSI 8 3 All HSI HSI 9 3 All RGB(w/ *Magic Amber) RGB(w/ *Magic Amber) 10 80 Cell Not Available 20xRGBA 11 80 Cell Not Available 20xRGBI(w/ *Magic Amber) 12 20 Block Not Available 5xRGBA 13 20 Block Not Available 5xRGBI(w/ *Magic Amber) 14 4 All Not Available RGBA 15 4 All Not Available RGBI(w/ *Magic Amber) 16 1 Any Look Select Look Select
When DMX is Lost If DMX is not detected press Enter, turn wheel to selection, press Enter for 2 seconds to save. Off
will snap to off; Hold – will hold last valid DMX state; Trig – will default to Time Trigger operation; Look 1-42 – will snap to the Look of your choice
Look Store
There are 42 internal FX Looks (1-9 are preset). To replay a Look, press Enter and scroll through the Looks. 2 ways to record or edit a Look:
Simple, with DMX console: set to Mode 1. Use DMX console to adjust the internal FX engine. Scroll to Look Store - press Enter, scroll to desired Look location and press Enter for 2 seconds to save.
Advanced, standalone: (To edit or record without a DMX console, please see the full User Manual available at www.ac-et.com)
Time Triggers
Press Enter and scroll to Time Trigger – press Enter. Press Enter to toggle between Day, Hour (24), Minutes and Look to be triggered - adjust setting with scroll wheel. Time Triggers will occur on all 7 days unless specified. The triggers will be activated when the mode “When DMX is Lost” is set to Trig.
Set Day and Time
Press Enter. Press Enter to toggle between Day, Hour (24) and Minutes, scroll wheel to adjust and press Enter for 2 seconds to save.
Displ Backlight
To set LCD backlight to go off after 5 seconds, press Enter and scroll wheel to On (permanently) or Off (after 5 seconds) and press Enter for 2 seconds to save setting.
Reset to Default
Press Enter for 2 seconds to reset all menu items to factory defaults: DMX address = 001, Control Mode = 1 (67 channels HSI+FX), DMX Lost = Hold, Looks = default, Display = On, Frequency = 360, System = CB2
System
To set PSU-05B for the Color Block DB4 (CB1) or the Color Block 2 (CB2) system press Enter, scroll wheel to select CB1 or CB2, press Enter for 2 seconds to save.
Frequency
360, 600, 1200 and 2400 frequency settings available for the LED scan rate to be synchronised with the video camera. Press Enter, scroll wheel to select frequency, press Enter for 2 seconds to save.
Sync Mode
Press Enter and use the scroll wheel to select Master or Slave. Press Enter for 2 seconds to save settings.
4. Further Information
Please refer to the Chroma-Q Color Block PSU-30 manual for more detailed information. A copy of the manual can be found at the Chroma-Q website – www.chroma-q.com – under Support.
Variable
Group
Cell
Group
Block Group
All
Group
Cell
Group
Block Group
All
Group
Mode 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Ch1 Group H-1 R-1 Speed H-1 R-1 Speed H-1 R-1 R-1 R-1 R-1 R-1 R-1 R-1 Ch2 Speed S-1 G-1 Fan S-1 G-1 Fan S-1 G-1 G-1 G-1 G-1 G-1 G-1 G-1 Ch3 Fan I-1 B-1 Range I-1 B-1 Range I-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 Ch4 Range H-2 R-2 Step H-2 R-2 Step A-1 I-1 A-1 I-1 A-1 I-1 Ch5 Step S-2 G-2 Int. FX S-2 G-2 Int. FX R-2 R-2 R-2 R-2 Ch6 Int. FX I-2 B-2 Int.Fan I-2 B-2 Int.Fan G-2 G-2 G-2 G-2 Ch7 Int.Fan H-3 R-3 H-1 H-3 R-3 H-1 B-2 B-2 B-2 B-2 Ch8 H-1 S-3 G-3 S-1 S-3 G-3 S-1 A-2 I-2 A-2 I-2 Ch9 S-1 I-3 B-3 I-1 I-3 B-3 I-1 R-3 R-3 R-3 R-3 Ch10 I-1 H-4 R-4 H-2 H-4 R-4 G-3 G-3 G-3 G-3 Ch11 H-2 S-4 G-4 S-2 S-4 G-4 B-3 B-3 B-3 B-3 Ch12 S-2 I-4 B-4 I-2 I-4 B-4 A-3 I-3 A-3 I-3 Ch13 I-2 H-5 R-5 H-3 H-4 R-5 R-4 R-4 R-4 R-4 and so on up to: Total 67 60 60 21 15 15 9 3 3 80 80 20 20 4 4