Chiyu Technology BF-2300 User Manual

BF-2300
12DI/6DO Serial and TCP/IP I/O Controller
User’s Guide
2005
CHIYU TECHNOLOGY CO., LTD
http://www.chiyu-t.com.tw
TAIPEI >> TEL:886-2-25491289 | CHIAYI >> TEL:886-5-2835460
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
Table of Content
1. Getting to Know your BF-2300
1.1 Introduction
1.2 Main features
1.3 Applications for BF-2300
2. Hardware Installation & Initial Setup…………………….5
2.1 Hardware Installation
2.2 LED status
………………………………………………………6
2.3 Initial Setup
2.3.1 Installing the TCP/IP Protocol………………………............5
2.3.2 Fixed IP Addresses Configuration…………………….........7
2.3.3 Configure your BF-2300……………………………….........10
3. BF-2300 Configuration Setup
3.1 Network Setting
3.2 Operation mode
3.3 Serial Type
………………………………………….........13
……………………………………………………...15
3.4 Dynamic DNS…………………………………………………...17
4. BF-2300 Management Setup
4.1 Device Admin
4.2 Device Status
……………………………………………………...19
4.3 Backup and Restore………………………………………......21
4.4 Upgrade Firmware
4.5 Ping
………………………………………………………………..22
5. Troubleshooting
………………………………………………….23
Appendix B: DDNS Appendix C: Glossary
…………………………………………….30
Appendix D: Finding the MAC Address and IP Address for Your Ethernet Adapter
BF-480M User’s Guide
……………………………………………............35
…………………………...1
…………………………….......4
……………………………....11
………………………………...18
- 1 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
Copyright by Chiyu Technology Co., Ltd., all rights reserved.
The information in this document has been carefully checked and is believed to be correct as of the date of publication. Chiyu Technology Co., Ltd. reserves the right to make changes in the product or specification, or both, presented in this publication at any time without notice.
Chiyu assumes no responsibility or liability arising from the specification listed herein. Chiyu makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patents, trademark, copyright, or rights of third parties. Implication or other under any patent or patent rights of Chiyu Technology Co., Ltd grants no license.
All other trademarks and registered trademarks are the property of their respective holders.
BF-480M User’s Guide
- 2 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
1. Getting to Know your BF-2300
1.1 Introduction
BF-2300 I/O controller is designed to make your industrial devices Internet monitor and control instantly. The compact size of BF-2300 I/O controller makes them the ideal choice for connecting your devices to an IP-based Ethernet LAN, making it possible for your software to monitor and control devices anywhere over serial port (RS232 and RS485), a local LAN or the Internet.
BF-2300 I/O controller ensure the compatibility of network software that uses a standard network API (Winsock or BSD Sockets) by providing TCP Server Mode, TCP Client Mode, and UDP Mode. And using Chiyu’s virtual COM drivers, software that works with COM ports can be set up to work over a TCP/IP network in no time. This excellent feature preserves your software investment and lets you enjoy the benefits of networking your serial devices instantly.
BF-2300 I/O controller support automatic IP configuration protocols (DHCP, BOOTP) and manual configuration via Chiyu’s web browser console. Both methods ensure quick and effective installation. BF-2300 support special design for PPPoE + DDNS that could let your device to connect to Internet without static IP address.
1.2 Main features
Package Checklist
BF-2300 is shipped with the following items: Standard Accessories
1 BF-2300 12DI/6DO I/O controller Document & Software CD Quick Installation Guide Product Warranty Booklet
Optional Accessories
Power adaptor
NOTE: Notify your sales representative if any of the above items is missing or damage d.
Product Features
BF-2300 enjoys the following features:
Make your devices monitored and controlled Internet ready Versatile socket operation modes, including TCP Server, TCP Client, and UDP Easy-to-use Windows Utility for mass installation Supports 10/100 Mbps Ethernet—auto detectable
. 18 channel I/O with 12 Isolated DI/6 Isolated Relay DO
12 Digital Input with Dry Contact
. 6 Relay Digital Output with Dry Contact
One RS-232 port, one RS-485 port and one RJ-45 port Built-in 15 KV ESD protection for all serial signals BF-2300 has 2 KV isolation protection
BF-480M User’s Guide
- 3 -
CHIYU TECHNOLOGY CO., LTD.
A
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
Product Specifications
CPU 16 bit CPU, 100MHz
Hardware
Interface
Configuration
Power
&
Environment
BF-480M User’s Guide
Memory 256 KB ROM & 1MB SDRAM Watch Dog Support watch Dog, system never halt Reset Button Multi-function for system restart and factory default reset
Ethernet
1 RJ-45 Port 10/100Base-T,half/full duplex, Auto Cross Over, 1.5 KV Magnetic protected
Serial
I/O
Port Interface Port Type signals protection
COM1 RS-232
COM2 RS-485
Screw Terminal Screw Terminal
TxD,RxD,RTC,CTS,DTR,DSR,DCD,GND 15KV ESD
D+, D- 15KV ESD
18 channel I/O 12 Isolated DI/6 Isolated Relay DO
Optical Isolation: 2,500V(DC)
Isolated Digital Input
Over-voltage Protect: 70V(DC) Dry Contact
Relay Digital Output Optical Isolation: 2,500V(DC)
Contact rating: AC:120V@0.5A
DC:30V@1A
Total switching time:10msec(on:7/off:3)
Ethernet
Static IP/DHCP Client/PPPoE
Serial
Parity Check None, even, odd, Mark, Space Data bits 5, 6, 7, 8 Stop bits 1, 2 Flow Control RTS/CTS, XON/XOFF
Supported OS
Protocol
Management
Power requirement DC 9-30V ,500mA Operation Temp. Operation Humidity 5 ~ 95%RH Storage Temp. Size 81X103X30 mm Magnetic protected Ethernet port 1.5 KV
pproval FCC, CE
Windows XP, Windows 2000, Windows NT, Windows95/98 ME, Linux, UNIX
TCP, IP, UDP, Telnet, ARP, DHCP, ICMP、SMTP、PPPoE、HTTP、DDNS Support TCP/UDP Server/Client mode
User name & password protected for web management Built-in Http server for set up and remote management via any browser
easily Support backup & restore system configuration data Support Windows 95/98/ME/NT/2000/XP/2003 virtual COM drivers
0 ~ 55
-20 ~ 85
- 4 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
The following are the main features of BF-2300
TCP/UDP server/client support
The BF-2300 support three types of connection: TCP server, TCP client and UDP , user can select one of types to meet application requirement.
DHCP Client
DHCP (Dynamic Host Configuration Protocol) client obtains the TCP/IP configuration at start-up from a centralized DHCP server, which means it can get IP address, an IP default gateway and DNS server.
PPP Over Ethernet
PPPoE is a protocol for connecting remote hosts to the Internet over DSL connection by simulating dial-up connection.
Dynamic DNS
With dynamic DNS support, you can have a static hostname alias for a dynamic IP address, allowing the host to be more easily accessible from various locations on the Internet.
Auto-negotiating 10/100Mbps Ethernet
The Ethernet interface automatically detects if it is on a 10 or a 100 Mbps Ethernet.
IO Remote Control
The BF-2300 provides command protocols to integrate into customer’s software via TCP/IP connection to monitor or control customer’s device.
Alarm Generation
With SMTP client support, you can set system to trigger alarm message via E-Mail or SMS (Short Message System) to your mobile phone.
Full Network Management via Web
This feature allows you to access or manage device through IE or Netscape on any platform. The firmware also can be upgraded via Web browser.
Backup and Restore configuration
This feature allows you to backup system configuration to a file and restores it, for the security issue, the file which backup from system is an encryption format.
Firmware Upgrade
BF-2300 support two ways of firmware upgrade: one is through Web browser such as IE or Netscape, another is through Xmoden protocol.
BF-480M User’s Guide
- 5 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
1.3 Applications for BF-2300
Figure 1 Standalone BF-2300’s application through Internet
2. Hardware Installation & Initial Setup
2.1 Hardware Installation
BF-2300
BF-480M User’s Guide
- 6 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
2.2 LED status
LED Color(s) Activity Desc.
Off Power OFF
Power Red
Red Blinking Booting/System Self-Test
Red On Device Ready
Link Green
Ethernet
(on the RJ-45
connector)
Transaction
RS232 Green Blinking Data Sending/Receiving through this COM port
RS485 Green Blinking Data Sending/Receiving through this COM port
SPD
Green
ACT Green
Link Green
Off No Ethernet Link
Green On Ethernet Link established
Off 10 Mbps
Green 100 Mbps
Off No data activity
Green Blinking
Off No TCP/IP session link
Green On TCP/IP session link established
Green Blinking
Transmitting/Receiving
Data Sending/Receiving between Serial and Ethernet
2.3 Initial Setup
Use this section to set up your computer to assign it a static IP address in the 192.168.0.1 to 192.168.0.254 range with a subnet mask of 255.255.255.0. This is necessary to ensure that your computer can communicate with your BF-2300.
Your computer must have an Ethernet card and TCP/IP installed. TCP/IP should already be installed on computer using Windows 98/2000/XP and later operating systems.
Note: Connect a computer to BF-2300 Ethernet port directly should be with crossover Ethernet cable, if both connect to hub/switch should be with straight-through Ethernet cable.
BF-480M User’s Guide
- 7 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
2.3.1 Installing the TCP/IP Protocol
If you are not sure whether the TCP/IP Protocol has been installed, follow these steps to check, and if necessary, install TCP/IP onto your PCs.
Step 1Click the “Start” button. Choose “Settings”, then “Control Panel”. Double-click the “Network
Connections” icon. Your Network window should appear as follows:
Step 2
For Windows 98 and Millennium
On the “Configuration” tab (if using Windows 98 and Millennium PCs), select the TCP/IP line for the
applicable Ethernet adapter. Do not choose a TCP/IP entry whose name mentions
PPPoE, VPN. If the word TCP/IP appears by itself, select that line. Click the Properties button.
BF-480M User’s Guide
- 8 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
Important:
For Windows 2000 & Windows XP Setting, you will find that they differ with Windows 98/ME/NT slightly. See the
following for reference.
For Windows XP and Windows 2000
Click the “Local Area Connection” icon on the lower right hand side of your desktop screen.
In the “Local Area Connection Status” window, click the “Properties” button then your Network window will
appear.
There are two tabs, “General” ”Support”, in the Network window.
Step 3:Check whether the TCP/IP Protocol has already been installed onto your computer’s Ethernet card. Note
that TCP/IP Protocol can be installed for a computer’s Dial-Up Adapter as well as for the Ethernet card.
If yes, go to section 2.3.2.
If no, click the “Install” button.
BF-480M User’s Guide
- 9 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
Step 4Double-click “Protocol” in the Select Network Component Type or highlight “Protocol” then click
“Add”.
Step 5Highlight “Microsoft” under the list of manufacturers. Double-click “TCP/IP” from the list on the right
or highlight “TCP/IP” then click “OK” to install TCP/IP.
Step 6 After a few seconds, you will be returned to the Network window. The TCP/IP Protocol should now be
on the list of installed network components (see 3 above).
2.3.2 Fixed IP Addresses Configuration
For Windows 98 and Millennium Step 1To set up computers with fixed IP Addresses, click the “Properties” button. The TCP/IP Properties
window consists of several tabs. Choose the “IP Address” tab as shown below.
Step 2:Select “Specify an IP address” and enter “192.168.0.xxx” (the default value of BF-2300 is
192.168.0.125) in the “IP Address” location (where xxx is a number between 1 and 254 used by the
High-Performance BF-2300 to identify each computer), and the default “Subnet Mask” “255.255.255.0”. Note
that no two computers on the same LAN can have the same IP address.
BF-480M User’s Guide
- 10 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
For Windows XP and Windows 2000
Step 1Make sure the box next to Internet Protocol (TCP/IP) is checked. Highlight Internet Protocol (TCP/IP), and click the Properties button
Step 2Select “Specify an IP address” and enter “192.168.0.xxx” (the default value of BF-2300 is
192.168.0.125) in the “IP Address” location (where xxx is a number between 1 and 254 used by the
High-Performance BF-2300 to identify each computer), and the default “Subnet Mask” “255.255.255.0”. Note
that no two computers on the same LAN can have the same IP address.
BF-480M User’s Guide
- 11 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
Click “OK”. to complete the TCP/IP installation.
2.3.3 Configure your BF-2300
Step 1Open your web browser and type http://19 2.168.0.125 in the browser’s address box. This address is the factory set IP Address of your BF-2300. Press “Enter.
Step 2The “Username and Password required” prompt box will appear. Typing “admin” (default username)
in the Username field and typing “admin” (default password) in the Password field. Click OK. The setup
screen will then appear.
Step 3:It is highly recommended you change the default username and password when you login successfully
first time.
Note: Don’t forget click Apply button to save your changing when you complete your configuration setting each time, the BF-2300 will restart automatically in 10 seconds with your new setting.
BF-480M User’s Guide
- 12 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
3. BF-2300 Configuration Setup
This chapter will show you how to configure BF-2300 to function in your network and gain access to your device through Intranet or Internet.
3.1 Network setting
The BF-2300 support three IP connection types: Static IP, DHCP and PPPoE. These types are listed in the drop-down menu for the IP Configuration setting. Each setup screen and available features will differ depending on what kind of IP connection types you select. Default is Static IP
Static (or Fixed) IP
IP Address
Setting Factory Default Necessity
E.g., 192.168.0.xxx 192.168.0.125 Required
Subnet mask
Setting Factory Default Necessity
E.g., 255.255.255.0 255.255.255.0 Required
Gateway
Setting Factory Default Necessity
E.g., 192.168.0.1 192.168.0.254 Optional
A device that interconnects networks with different, incompatible communications protocols. For correct gateway IP address information, consult the network administrator. BF-2300 need to know the IP address of the gateway device in order to communicate with the hosts outside the local network environment.
BF-480M User’s Guide
- 13 -
CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
Primary DNS
Setting Factory Default Necessity
E.g., 168.95.1.1 168.95.1.1 Optional
The Domain Name System (DNS) is the way that Internet domain names are located and translated into Internet Protocol (IP) addresses.
When the user wants to visit a particular website, the computer asks a Domain Name System (DNS) server for the website’s correct IP address, and the computer users the response to connect to the web server. DNS is the way that Internet domain names are identified and translated into IP addresses. A DNS server is a host that translates this kind of text-based domain name into the numeric IP address used to establish a TCP/IP connection.
If you are connecting through a static or fixed IP from your network environment, perform these steps
Step 1: Enter IP address Step 2: Enter Subnet mask Step 3: Enter Gateway IP address Step 4: Enter Primary DNS IP address Step 5: click Apply button
DHCP
Host Name
Setting Factory Default Necessity
max length is 15 characters CHIYU Optional