Chiltern Invadex Side Entry Mk2 User And Installation Manual

Side Entry Mk2
Shower Cubicle
user and installation guide
Side Entry Mk2
User Guide
Contents
Installation ........................................................2
Cleaning & Maintenance ............................... 14
Troubleshooting ............................................. 15
Operation Guide ............................................ 16
Accessories.................................................... 17
Spare parts ..................................................... 18
Warranty ......................................................... 20
Shower Cubicle
These products have been designed to the highest standards with safety, strength and quality in mind.
Follow the recommendations in this guide to ensure maximum benefit from your Chiltern Invadex
Shower Cubicle.
1
Chiltern Invadex Side Entry MK2
User Guide
19
5, 6, 7
1
8
3
9
4
2
Waste pump Detail
10
11
Installation
General Guide For your safety this installation should be completed by personnel complying with all relevant regulations and
Chiltern Invadex Shower cubicles are manufactured to many different specifications and sizes. It is therefore important that all services relevant assemble your shower cubicle. All building work and decorating should be finished i.e. a suitable floor in place, skirting boards painted and fixed, walls
Check all the items in the carton against the parts list on the enclosed leaflet.
Should you require any technical assistance or have any queries regarding installation procedures contact your nearest Chiltern Invadex Office. For an efficient response it will help if you have the model type and serial number to hand when you call (the serial number can be found on the label on the back panel).
Services The installation must be in accordance with local water company byelaws.
Mixer showers
Both hot and cold supplies must come from the water storage tanks with at least 2 metres head of water above the shower. BOOSTER PUMP If the required head of water is not available a Twin Impeller Booster Pump can be employed. Do not use flow switches. All supplies should terminate close to the relevant controls with a 3/4" B. S. Male outlet. We strongly recommend that accessible isolating valves are fitted near to our units to facilitate future servicing, or isolation, in the event of an emergency.
to your model are complete and tested before you attempt to
and ceilings plastered and decorated.
- Incoming Water
qualified
byelaws.
Instantantaneous Shower
15mm pipe with mains cold water supply. Minimum operating pressure 1 bar (14.5 p.s.i.). Permissible pressure variations 1 bar - 10 bar (14.5 p.s.i. - 145 p.s.i.).
Waste Water (fig 1) The Chiltern Invadex Shower has a 12 volt pump positioned in the rear left hand corner of the cabinet. It pumps the waste water out of the base to a waste stack similar to that used by a washing machine. The waste stack need only be in 1 1/4" (32mm) plastic but it is necessary to fit a trap to prevent odours.
2
User Guide
3
Fig 1
The height of the waste stack should be between 508mm and 711mm above the floor level and fitted to the left hand rear of the proposed shower position (see diagram). This diagram is only one example of an installation. The position of the pipework will vary according to individual situations. NOTE: The lower the waste stack pipe the less water will be
left in the trough once the pump is turned off.
Waste Detail
Waste
508mm-711mm
The 102mm (4”) pipe in Chiltern Invadex Side Entry MK2 Shower To ilets is connected through the side panel. The toilet waste pipe must also be connected when the side panel is fitted.
The position of the pan on the base unit must relate to the individual requirements of the user and we recommend that this operation is left until later. Flush pipe and multikwik pan connector are supplied for standard installation. These can be extended on site. Additional parts are not included.
Side Elevation
297
170
110mm soil pipe connection
232
40mm connection to flexible pipe from flush tank
minimum clearance from wall
Front Elevation
Fitting Instructions for Side Entry MK2 Shower Toilet
Locating the toilet pan and cistern
Chiltern Invadex Side Entry MK2
e
5
Installation (continued)
Wire Sizes Incoming Mains-220-240V 50/60Hz (UK and Europe only) Cable size to suit application. Electrical shower-(Please refer to manufacturers instructions - supplied separately) Pumped waste-Cable supplied (do not replace cable if faulty. Please call your nearest Chiltern Invadex regional office for replacement)
Waste pump technical specification
operating voltage 12 volts DC (via transformer) Current rating 3.0 amps maximum Rating- 315mA Delivery output 18ltrs/min maximum Class II Insulation class-
Type B equipment-
All electrical installations should be carried out by qualified personnel, complying with all relevant byelaws and IEE regulations.
Prior to installing your shower cubicle find out whether the unit is to be installed with an electric shower unit, or thermostatic mixer unit. Then refer to the relevant figure for correct installation.
Bathroom IP Wiring Zones
Wiring block must be located outside of zones 0,1 and 2
75cm
60cm
225cm
60cm radius
4
User Guide
5
FUSE 315mA
FUSE 2 amp
N
EARTH
L
SUPPLY
L
EARTH
N
LOAD
L N
AUX
Electrical supply
WARNING! GENERAL ADVICE FOR INSTALLERS
All installations must comply with I.E.E. regulations, Local Authority bylaws and electricity board regulations and must be carried out only by a qualified electrician. Follow manufacturers instructions for installation of the shower heater unit for all electrical units.
SUGGESTED WIRING METHOD
Run a suitable cable (6-10mm sqr for electric showers depending on power rating and supply distance) from the consumer box via 30mA RCD to the Double pole ceiling pull switch in the wiring block supplied. (This switch is used to isolate the shower as well as turning the shower waste pump on and off and must be accessible to a wheelchair user where applicable).
The wiring block is positioned at a maximum of 4m from the pump unit and complies
with all mentioned regulations. Follow connection instructions
included with wiring block to complete electrical supply.
Shower & pumped waste
The correct wiring installation for the electric shower and pumped waste is shown in Fig 2. Please pay particular attention to the wire sizes.
Electrical Installation
*Note: For mixer showers load output cable is not required.
Blue
Red
230v AC supply feed in cable 6-10mm
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
*230v AC load output cable to electric shower 6-10mm
3 core flex (supplied) to waste pump low voltage
Auxiliary output for eg. 230v fan via 2 amp fuse
Green
Fig 2
12v DC
Chiltern Invadex Side Entry MK2
6
Installation details (use fig 3 with instructions)
Fig 3
10
2
8
3
9
1
7
6
4
5
User Guide
7
Note:
Assembling the cubicle in situ is usually easier than moving the assembled unit.
1. Fig 4.0-Ensure that the shower tray is placed on the floor and is level along its length and width. Also ensure that the 4x30mm blocks are inserted in the bottom of all 4 corner sections before assembly, as fig 4.1.
2. Fig 4.1 -Locate the corner post onto the factory fitted foot section (the only corner post with a large hole in the bottom). Secure with the grub screw supplied (see inset). This is always on the
pump post outlet.
Fig 4
Fig 4.1
User Guide
13
Pumped waste assembly
11. Fig 4.10 Push outlet (waste) hose through the hole in the corner post (1) and secure it to the stack pipe moulded in the base. Do not stretch the waste pipe, allow for possible adjustment. Connect the pump unit to the electrical connector, ensuring a firm fit. Push the motor housing into the base socket until the face of the pump and socket meet. Prior to fitting the pump cover (10) ensure that the electrical cable and waste pipe are clear of obstructions.
Fig 4.10
To waste pipe
Chiltern Invadex Side Entry MK2
8
3. Fig 4.2 Locate the large rear back panel (3) into the channel in the corner post.
4. Fig 4.3 Slide in the second corner section. This section seat fixing plate (with 4 holdes) and is blank i.e without any door adjusting slots. Tighten the section with the allen key supplied.
Fig 4.2
Fig 4.3
User Guide
9
5. Fig 4.4 Locate the side panel (5) into the channel in the corner post.
6. Fig 4.5 Position the corner post (6) repeat as instruction 4.
Fig 4.4
Fig 4.5
User Guide
11
9. Fig 4.8. Prior to fitting the roof panel, ensure that the cubicle is square and upright.
Locate the roof panel (9) into the top of the corner posts one at a time.
Slackening the roof screws will be helpful if the roof is difficult to align. Secure with grub screws.
If an (optional) seat is to be fitted
The sliders must be positioned first. Feed them into the channel from the top and push them all the way down to the bottom of the side panel.
The seat can then be fitted using the screws provided.
Please contact your Chiltern Invadex regional office if a seat is required, but has not been ordered.
Fig 4.8
Chiltern Invadex Side Entry MK2
10
8. Fig 4.7 Position the grab rails onto the factory fitted securing
blocks. Secure via 2 M4x6mm screws provided (see inset).
Key A - Back grab rail B - Side grab rail
C - Shower riser rail
7. Fig 4.6 Locate the
side panel (with the shower unit on it) (8) into the corner post channel (1) and locate corner post
(7). Fix as previous.
Fig 4.6
Fig 4.7
C
B
A
User Guide
11
9. Fig 4.8. Prior to fitting the roof panel, ensure that the cubicle is square and upright.
Locate the roof panel (9) into the top of the corner posts one at a time.
Slackening the roof screws will be helpful if the roof is difficult to align. Secure with grub screws.
If an (optional) seat is to be fitted
The sliders must be positioned first. Feed them into the channel from the top and push them all the way down to the bottom of the side panel.
The seat can then be fitted using the screws provided.
Please contact your Chiltern Invadex regional office if a seat is required, but has not been ordered.
Fig 4.8
User Guide
9
5. Fig 4.4 Locate the side panel (5) into the channel in the corner post.
6. Fig 4.5 Position the corner post (6) repeat as instruction 4.
Fig 4.4
Fig 4.5
Chiltern Invadex Side Entry MK2
12
Door assembly ­Swinging doors (standard)
10. Fig 4.9 Slide the doors into the corner posts (6,7), ensuring that the doors open outwards. Secure with the screws and slot covers provided (see Inset). Check that the doors open and close correctly and the bottom seal is in contact with the shower tray base. The door must nearly be touching when closed so as not to leak. Using the drill provided drill through the holes in the corner section and lock into position with the 1/2” self tapping screws and shakeproof washers provided.
Tri-fold/bi-fold doors
Slide the door into the corner section and tighten screws, shake-proof washers and slot covers loosely. Place the door receiver into the opposing corner section and tighten with two washers, slot covers and 1/2” screws. Before locking the door tight ensure that the door is straight and that the sliding handle locks correctly. Also, check that the magnetic strip mates with the one in the receiver.
Fig 4.9
User Guide
13
Pumped waste assembly
11. Fig 4.10 Push outlet (waste) hose through the hole in the corner post (1) and secure it to the stack pipe moulded in the base. Do not stretch the waste pipe, allow for possible adjustment. Connect the pump unit to the electrical connector, ensuring a firm fit. Push the motor housing into the base socket until the face of the pump and socket meet. Prior to fitting the pump cover (10) ensure that the electrical cable and waste pipe are clear of obstructions.
Fig 4.10
To waste pipe
User Guide
7
Note:
Assembling the cubicle in situ is usually easier than moving the assembled unit.
1. Fig 4.0-Ensure that the shower tray is placed on the floor and is level along its length and width. Also ensure that the 4x30mm blocks are inserted in the bottom of all 4 corner sections before assembly, as fig 4.1.
2. Fig 4.1 -Locate the corner post onto the factory fitted foot section (the only corner post with a large hole in the bottom). Secure with the grub screw supplied (see inset). This is always on the
pump post outlet.
Fig 4
Fig 4.1
Chiltern Invadex Side Entry MK2
14
Cleaning & Maintenance
Regular
Shower Cubicles do not require any major maintenance, but you should follow these simple instructions:
Tray and Enclosure
To retain the surface quality of your shower cubicle, weekly cleaning using bathroom cleaning mousse or washing-up liquid, warm water and a soft cloth is recommended. For the slip resistant shower tray area you may need to use a stiff brush. Stubborn stains may require a non-scratch liquid cleaner.
Do not use oven cleaner or a scouring powder on any of the surfaces. Use of scourers will dull the finish of the surfaces and spoil the appearance of your tray and enclosure.
Shower Head (Handset)
If you live in a ‘hard-water’ area, the holes in the shower head will block more quickly. This will result in a poor spray and a reduction in the heating ability of some instant water heaters. Remove rings from the shower head and vigorously scrape out the scale in the grooves, ensuring that the holes are clear.
Monthly Pump Maintenance (for trays with pumped waste)
Regularly (monthly) lift pump from the socket in the base and remove foreign matter from the blades. Scrub the area around the pump with a long handled stiff brush. This will reduce the build up of scum and odours. Check that the small bore hole adjacent to the pump blades is clean. Replace pump cover making sure that the pump cover touches the shower base.
For performance regularly clean pump and shower head.
Annual
We recommend that the unit is serviced by a qualified Chiltern Invadex engineer. This will ensure that the unit complies with current health and safety regulations.
Troubleshooting
symptom suggested cause solution
Mixer Showers
Reduced flow of water from the shower head.
Electric Showers
Reduced flow of water from the shower head.
Te mperature of showering water is too cool.
Shower cuts out.
Spray rings in the shower head have a build up of limescale and need cleaning.
Water supply* pressure is lower than
Water supply is colder than normal, possibly due to weather conditons.
Water supply* pressure is lower than normal. Te mperature is set higher than safety cut-out. Spray rings in the shower head have a buid up of lime-scale and need cleaning.
Water supply* pressure is lower than normal.
normal.
Rub clean head of handset to clear any scale build up.
See note 1 below.
Check unit is on maximum heat setting/ reduce flow.
Turn down the tempera­ture and try again, Pump needs cleaning.
User Guide
Pumped shower waste
Water level higher than normal.
Unpleasant odour from cubicle
Waste hose is blocked.
Water left in gully at back of shower after use.
Stagnant soapy water in the back gully.
Unblock waste hose.
This is normal. The water left in the waste hose when the pump stops will run back when the pump stops.
shower should be run
The for a couple of minutes after use
to ensure that
the
residual water is
clean.
Note 1: *Water supply presssures may be affected by simultaneous use of water at another point in the house, a fault in the house plumbing or a problem with the water supply to the house.
For further assistance please telephone your nearest Chiltern Invadex Regional Office. Remember that the service calls made after the expiry of the guarantee will be chargeable. If maintenance of the equipment is the responsibility of a third party, for example the Social Services, please contact them in the first instance.
15
User Guide
5
FUSE 315mA
FUSE 2 amp
N
EARTH
L
SUPPLY
L
EARTH
N
LOAD
L N
AUX
Electrical supply
WARNING! GENERAL ADVICE FOR INSTALLERS
All installations must comply with I.E.E. regulations, Local Authority bylaws and electricity board regulations and must be carried out only by a qualified electrician. Follow manufacturers instructions for installation of the shower heater unit for all electrical units.
SUGGESTED WIRING METHOD
Run a suitable cable (6-10mm sqr for electric showers depending on power rating and supply distance) from the consumer box via 30mA RCD to the Double pole ceiling pull switch in the wiring block supplied. (This switch is used to isolate the shower as well as turning the shower waste pump on and off and must be accessible to a wheelchair user where applicable).
The wiring block is positioned at a maximum of 4m from the pump unit and complies
with all mentioned regulations. Follow connection instructions
included with wiring block to complete electrical supply.
Shower & pumped waste
The correct wiring installation for the electric shower and pumped waste is shown in Fig 2. Please pay particular attention to the wire sizes.
Electrical Installation
*Note: For mixer showers load output cable is not required.
Blue
Red
230v AC supply feed in cable 6-10mm
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
*230v AC load output cable to electric shower 6-10mm
3 core flex (supplied) to waste pump low voltage
Auxiliary output for eg. 230v fan via 2 amp fuse
Green
Fig 2
12v DC
Chiltern Invadex Side Entry MK2
Operation guide
If a seat is fitted
Fold down the seat, ensuring the feet are firmly placed on the shower tray, then transfer to the seat.
All cubicles
Pull the mains cord to provide power to the pump/shower.
Operate the shower noting the hot and cold position.
To minimise spray always ensure the shower curtain is closed.
Cross Infection
Warning: If this unit is to be ustilised by many different bathers, then we
would strongly recommend that this unit be cleaned with a medical disinfectant. Please contact your local infection control nurse for further advice.
16
User Guid
e
Accessories
Large horseshoe
445mm
Folding Shower seat
Vinyl seat
445mm
Flat padded
445mm
Large aperture
445mm
Medium horseshoe
445mm
Small horseshoe
445mm
Medium aperture
445mm
Small aperture
17
User Guide
3
Fig 1
The height of the waste stack should be between 508mm and 711mm above the floor level and fitted to the left hand rear of the proposed shower position (see diagram). This diagram is only one example of an installation. The position of the pipework will vary according to individual situations. NOTE: The lower the waste stack pipe the less water will be
left in the trough once the pump is turned off.
Waste Detail
Waste
508mm-711mm
The 102mm (4”) pipe in Chiltern Invadex Side Entry MK2 Shower To ilets is connected through the side panel. The toilet waste pipe must also be connected when the side panel is fitted.
The position of the pan on the base unit must relate to the individual requirements of the user and we recommend that this operation is left until later. Flush pipe and multikwik pan connector are supplied for standard installation. These can be extended on site. Additional parts are not included.
Side Elevation
297
170
110mm soil pipe connection
232
40mm connection to flexible pipe from flush tank
minimum clearance from wall
Front Elevation
Fitting Instructions for Side Entry MK2 Shower Toilet
Locating the toilet pan and cistern
Chiltern Invadex Side Entry MK2
Spare parts
no description qt y part no
1Shower Base (pumped waste) 1 IDISE03 2Grab Rail - V/H (state panel and model) 1 SHSU023SE2 3Back Panel 1 SHPA003SEMK2 4Roof Light 1 SHSU042 5Standard Door 1 SH00478SE2 6Bifold Door* 1 SHPA009BSE2 7Trifold Doors* 1 SHPA009(L)(R) SE2 8Side panel * SHPA001SE2
9Roof 1 SHPA006SEMK2 10 Pump Cover 1 SH0646SE2 11 12v Waste Pump 1 SHPU030
1
*add L or R for left or right hand
18
User Guide
19
5, 6, 7
1
8
3
9
4
2
Waste pump Detail
10
11
Chiltern Invadex Side Entry MK2
r
Warranty
Your Chiltern Invadex Shower Cubicle carries a 12 month warranty from the date of purchase (for guarantee on shower unit see manufacturers details), subject to the following:-
1. Should you experience any problems with our workmanship or materials within the first 12 months period, please contact your point of purchase.
2. Repairs made during the warranty period will be carried out free of charge, provided the product has been used strictly in accordance with the guidelines set out in this user guide.
3. Our warranty does not cover replacements, adjustments or repairs which may be required as result of normal wear and tear, wilful or accidental damage, misuse, neglect or any other cause which is beyond the control of Chiltern Invadex.
4. Modifications and repairs made to this product by unauthorised persons will render the warranty void.
5. Only parts manufactured or approved by Chiltern Invadex shall be used to repair this product. Use of unauthorised parts will invalidate all warranties and remove all liability from Chiltern Invadex for the safety of this product.
6. Chiltern Invadex shall in no event be liable for any damages, costs or expenses arising from any claim made under this warranty (save fo any legal liability of Chiltern Invadex for death or personal injury resulting from the company’s negligence in respect of its products).
7. Faults due to inadequate cleaning, limescale or other water impurities including debris not flushed from the supply pipe work prior to connection are excluded from this warranty.
8. This warranty does not affect your statutory consumer rights
20
Please fill in the information below for future reference
Dealers Name
..........................................................................
Address
..........................................................................
..........................................................................
....................... Post Code.................................
Te lephone ........................................................
Your Serial Number is
..................................
Date of purchase
...........................
Chiltern Invadex (UK) Ltd
126 Churchill Road
Bicester Oxfordshire OX26 4XD
Te l: 01869 365500
Fax: 01869 365588
Web: www.chilterninvadex.co.uk
E-mail: sales@chilterninvadex.co.uk
Side Entry Mk2
Copyright © Chiltern Invadex (UK) Ltd The design of the product shown in this guide is vested in Chiltern Invadex (UK) Ltd and should not be copied or
reproduced in anyway whatsoever without the express permission in writing of Chiltern Invadex (UK) Ltd.
Published by: Chiltern Invadex (UK) Ltd 126 Churchill Road, Bicester, Oxfordshire OX26 4XD Registered in England No: 04704248
Shower Cubicle
 WEEE producer number WEE/JD1274RU
The crossed wheelie bin symbol shown on the pumped waste option of this product indicates that the item must not be disposed of with general household waste. Proper recovery of your waste electronic and electrical equipment will ensure safety of human health and the environment.
For more information where the product can be safely disposed of please contact your Local Authority, the dealer from where the product was purchased or Chiltern Invadex (UK) Limited.
CINV 86.05 November 2010
Loading...