These products have been designed to the
highest standards with safety, strength and
quality in mind.
Follow the recommendations in this guide to
ensure maximum benefit from your Chiltern
Invadex
Shower Cubicle.
1
Chiltern Invadex Side Entry MK2
User Guide
19
5, 6, 7
1
8
3
9
4
2
Waste pump Detail
10
11
Installation
General Guide
For your safety this installation should be completed by
personnel complying with all relevant regulations and
Chiltern Invadex Shower cubicles are manufactured to many different
specifications and sizes. It is therefore important that all services
relevant
assemble your shower cubicle. All building work and decorating should
be finished i.e. a suitable floor in place, skirting boards painted and fixed,
walls
Check all the items in the carton against the parts list on the
enclosed leaflet.
Should you require any technical assistance or have any queries
regarding installation procedures contact your nearest Chiltern Invadex
Office. For an efficient response it will help if you have the model type
and serial number to hand when you call (the serial number can be found
on the label on the back panel).
Services
The installation must be in accordance with local water company
byelaws.
Mixer showers
Both hot and cold supplies must come from the water storage tanks with
at least 2 metres head of water above the shower.
BOOSTER PUMP If the required head of water is not available a Twin
Impeller Booster Pump can be employed. Do not use flow switches.
All supplies should terminate close to the relevant controls with a 3/4" B.
S. Male outlet. We strongly recommend that accessible isolating valves
are fitted near to our units to facilitate future servicing, or isolation, in the
event of an emergency.
to your model are complete and tested before you attempt to
and ceilings plastered and decorated.
- Incoming Water
qualified
byelaws.
Instantantaneous Shower
15mm pipe with mains cold water supply.
Minimum operating pressure 1 bar (14.5 p.s.i.).
Permissible pressure variations 1 bar - 10 bar (14.5 p.s.i. - 145 p.s.i.).
Waste Water (fig 1)
The Chiltern Invadex Shower has a 12 volt pump positioned in the rear
left hand corner of the cabinet. It pumps the waste water out of the base
to a waste stack similar to that used by a washing machine.
The waste stack need only be in 1 1/4" (32mm) plastic but it is necessary
to fit a trap to prevent odours.
2
User Guide
3
Fig 1
The height of the waste stack should be between 508mm and 711mm
above the floor level and fitted to the left hand rear of the proposed
shower position (see diagram). This diagram is only one example of an
installation. The position of the pipework will vary according to individual
situations. NOTE: The lower the waste stack pipe the less water will be
left in the trough once the pump is turned off.
Waste Detail
Waste
508mm-711mm
The 102mm (4”) pipe in Chiltern Invadex Side Entry MK2 Shower
To ilets is connected through the side panel. The toilet waste pipe
must also be connected when the side panel is fitted.
The position of the pan on the base unit must relate to the individual
requirements of the user and we recommend that this operation is left
until later. Flush pipe and multikwik pan connector are supplied for
standard installation. These can be extended on site. Additional parts
are not included.
Side Elevation
297
170
110mm soil pipe
connection
232
40mm connection
to flexible pipe from
flush tank
minimum clearance
from wall
Front Elevation
Fitting Instructions for Side Entry MK2 Shower Toilet
Locating the toilet
pan and cistern
Chiltern Invadex Side Entry MK2
e
5
Installation (continued)
Wire Sizes
Incoming Mains-220-240V 50/60Hz (UK and Europe only) Cable size to
suit application.
Electrical shower-(Please refer to manufacturers instructions - supplied
separately)
Pumped waste-Cable supplied (do not replace cable if faulty. Please
call your nearest Chiltern Invadex regional office for replacement)
Waste pump technical specification
operating voltage12 volts DC (via transformer)
Current rating 3.0 amps maximumRating- 315mA
Delivery output 18ltrs/min maximum
Class II
Insulation class-
Type B equipment-
All electrical installations should be carried out by qualified
personnel, complying with all relevant byelaws and IEE regulations.
Prior to installing your shower cubicle find out whether the unit is to be
installed with an electric shower unit, or thermostatic mixer unit.
Then refer to the relevant figure for correct installation.
Bathroom IP Wiring Zones
Wiring block must be located outside of zones 0,1 and 2
75cm
60cm
225cm
60cm radius
4
User Guide
5
FUSE
315mA
FUSE
2 amp
N
EARTH
L
SUPPLY
L
EARTH
N
LOAD
L N
AUX
Electrical supply
WARNING! GENERAL ADVICE FOR INSTALLERS
All installations must comply with I.E.E. regulations, Local Authority
bylaws and electricity board regulations and must be carried out only by
a qualified electrician.
Follow manufacturers instructions for installation of the shower heater
unit for all electrical units.
SUGGESTED WIRING METHOD
Run a suitable cable (6-10mm sqr for electric showers depending on power
rating and supply distance) from the consumer box via 30mA RCD to the
Double pole ceiling pull switch in the wiring block supplied. (This switch is
used to isolate the shower as well as turning the shower waste pump on
and off and must be accessible to a wheelchair user where applicable).
The wiring block is positioned at a maximum of 4m from the pump unit and
complies
with all mentioned regulations. Follow connection instructions
included with wiring block to complete electrical supply.
Shower & pumped waste
The correct wiring installation for the electric shower and pumped waste
is shown in Fig 2. Please pay particular attention to the wire sizes.
Electrical Installation
*Note: For mixer showers load output cable is not required.
Blue
Red
230v AC
supply
feed in
cable 6-10mm
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
*230v AC load
output cable to
electric shower
6-10mm
3 core flex
(supplied) to
waste pump
low voltage
Auxiliary output
for eg. 230v fan
via 2 amp fuse
Green
Fig 2
12v DC
Chiltern Invadex Side Entry MK2
6
Installation details (use fig 3 with instructions)
Fig 3
10
2
8
3
9
1
7
6
4
5
User Guide
7
Note:
Assembling the
cubicle in situ is
usually easier than
moving the assembled
unit.
1. Fig 4.0-Ensure that
the shower tray is
placed on the floor
and is level along its
length and width. Also
ensure that the
4x30mm blocks are
inserted in the bottom
of all 4 corner
sections before
assembly, as fig 4.1.
2. Fig 4.1 -Locate the
corner post onto the
factory fitted foot
section (the only
corner post with a
large hole in the
bottom). Secure with
the grub screw
supplied (see inset).
This is always on the
pump post outlet.
Fig 4
Fig 4.1
User Guide
13
Pumped wasteassembly
11. Fig 4.10 Pushoutlet (waste) hosethrough the hole in thecorner post (1) andsecure it to the stackpipe moulded in thebase. Do not stretchthe waste pipe, allowfor possibleadjustment. Connectthe pump unit to theelectrical connector,ensuring a firm fit.Push the motorhousing into the basesocket until the face ofthe pump and socketmeet. Prior to fittingthe pump cover (10)ensure that theelectrical cable andwaste pipe are clearof obstructions.
Fig 4.10
Towaste pipe
Chiltern Invadex Side Entry MK2
8
3. Fig 4.2 Locate the
large rear back panel
(3) into the channel in
the corner post.
4. Fig 4.3 Slide in the
second corner
section. This section
seat fixing plate (with
4 holdes) and is blank
i.e without any door
adjusting slots.
Tighten the section
with the allen key
supplied.
Fig 4.2
Fig 4.3
User Guide
9
5. Fig 4.4 Locate the
side panel (5) into the
channel in the corner
post.
6. Fig 4.5 Position the
corner post (6) repeat
as instruction 4.
Fig 4.4
Fig 4.5
User Guide
11
9.Fig 4.8. Prior tofitting the roof panel,ensure that thecubicle is square andupright.
Locate the roof panel(9) into the top of thecorner posts one at atime.
Slackening the roofscrews will be helpfulif the roof is difficultto align. Secure withgrub screws.
If an (optional) seat isto be fitted
The sliders must bepositioned first. Feedthem into the channelfrom the top and pushthem all the waydown to the bottom ofthe side panel.
The seat can then befitted using thescrews provided.
Please contact yourChiltern Invadexregional office if aseat is required, buthas not been ordered.
Fig 4.8
Chiltern Invadex Side Entry MK2
10
8. Fig 4.7 Position the
grab rails onto the
factory fitted
securing
blocks.
Secure via 2 M4x6mm
screws provided
(see inset).
Key
A - Back grab rail
B - Side grab rail
C - Shower riser rail
7. Fig 4.6 Locate the
side panel (with the
shower unit on it) (8)
into the corner post
channel (1) and
locate corner post
(7). Fix as previous.
Fig 4.6
Fig 4.7
C
B
A
User Guide
11
9. Fig 4.8. Prior to
fitting the roof panel,
ensure that the
cubicle is square and
upright.
Locate the roof panel
(9) into the top of the
corner posts one at a
time.
Slackening the roof
screws will be helpful
if the roof is difficult
to align. Secure with
grub screws.
If an (optional) seat is
to be fitted
The sliders must be
positioned first. Feed
them into the channel
from the top and push
them all the way
down to the bottom of
the side panel.
The seat can then be
fitted using the
screws provided.
Please contact your
Chiltern Invadex
regional office if a
seat is required, but
has not been ordered.
Fig 4.8
User Guide
9
5. Fig 4.4 Locate theside panel (5) into thechannel in the cornerpost.
6. Fig 4.5 Position thecorner post (6) repeatas instruction 4.
Fig 4.4
Fig 4.5
Chiltern Invadex Side Entry MK2
12
Door assembly Swinging doors
(standard)
10. Fig 4.9 Slide the
doors into the corner
posts (6,7), ensuring
that the doors open
outwards. Secure
with the screws and
slot covers provided
(see Inset). Check
that the doors open
and close correctly
and the bottom seal is
in contact with the
shower tray base.
The door must nearly
be touching when
closed so as not to
leak. Using the drill
provided drill through
the holes in the
corner section and
lock into position with
the 1/2” self tapping
screws and
shakeproof washers
provided.
Tri-fold/bi-fold
doors
Slide the door into the
corner section and
tighten screws,
shake-proof washers
and slot covers
loosely. Place the
door receiver into the
opposing corner
section and tighten
with two washers,
slot covers and 1/2”
screws. Before
locking the door tight
ensure that the door
is straight and that the
sliding handle locks
correctly. Also,
check that the
magnetic strip mates
with the one in the
receiver.
Fig 4.9
User Guide
13
Pumped waste
assembly
11. Fig 4.10 Push
outlet (waste) hose
through the hole in the
corner post (1) and
secure it to the stack
pipe moulded in the
base. Do not stretch
the waste pipe, allow
for possible
adjustment. Connect
the pump unit to the
electrical connector,
ensuring a firm fit.
Push the motor
housing into the base
socket until the face of
the pump and socket
meet. Prior to fitting
the pump cover (10)
ensure that the
electrical cable and
waste pipe are clear
of obstructions.
Fig 4.10
To waste pipe
User Guide
7
Note:
Assembling thecubicle in situ isusually easier thanmoving the assembledunit.
1. Fig 4.0-Ensure thatthe shower tray isplaced on the floorand is level along itslength and width. Alsoensure that the4x30mm blocks areinserted in the bottomof all 4 cornersections beforeassembly, as fig 4.1.
2. Fig 4.1 -Locate thecorner post onto thefactory fitted footsection (the onlycorner post with alarge hole in thebottom). Secure withthe grub screwsupplied (see inset).This is always on the
pump post outlet.
Fig 4
Fig 4.1
Chiltern Invadex Side Entry MK2
14
Cleaning & Maintenance
Regular
Shower Cubicles do not require any major maintenance, but you should
follow these simple instructions:
Tray and Enclosure
To retain the surface quality of your shower cubicle, weekly
cleaning using bathroom cleaning mousse or washing-up liquid,
warm water and a soft cloth is recommended. For the slip resistant
shower tray area you may need to use a stiff brush. Stubborn stains
may require a non-scratch liquid cleaner.
Do not use oven cleaner or a scouring powder on any of the
surfaces. Use of scourers will dull the finish of the surfaces and
spoil the appearance of your tray and enclosure.
Shower Head (Handset)
If you live in a ‘hard-water’ area, the holes in the shower head will
block more quickly. This will result in a poor spray and a reduction
in the heating ability of some instant water heaters.
Remove rings from the shower head and vigorously scrape out the
scale in the grooves, ensuring that the holes are clear.
Monthly
Pump Maintenance (for trays with pumped waste)
Regularly (monthly) lift pump from the socket in the base and remove
foreign matter from the blades. Scrub the area around the pump with a
long handled stiff brush. This will reduce the build up of scum and
odours. Check that the small bore hole adjacent to the pump blades is
clean. Replace pump cover making sure that the pump cover touches the
shower base.
For performance
regularly clean pump
and shower head.
Annual
We recommend that the unit is serviced by a qualified Chiltern Invadex
engineer. This will ensure that the unit complies with current health and
safety regulations.
Troubleshooting
symptomsuggested causesolution
Mixer Showers
Reduced flow of water
from the shower head.
Electric Showers
Reduced flow of water
from the shower head.
Te mperature of showering
water is too cool.
Shower cuts out.
Spray rings in the shower
head have a build up of
limescale and need
cleaning.
Water supply* pressure
is lower than
Water supply is colder
than normal, possibly due
to weather conditons.
Water supply* pressure is
lower than normal.
Te mperature is set higher
than safety cut-out.
Spray rings in the shower
head have a buid up of
lime-scale and need
cleaning.
Water supply* pressure is
lower than normal.
normal.
Rub clean head of
handset to clear any
scale build up.
See note 1 below.
Check unit is on
maximum heat setting/
reduce flow.
Turn down the temperature and try again, Pump
needs cleaning.
User Guide
Pumped shower waste
Water level higher than
normal.
Unpleasant odour
from cubicle
Waste hose is blocked.
Water left in gully at back
of shower after use.
Stagnant soapy water in
the back gully.
Unblock waste hose.
This is normal. The water
left in the waste hose
when the pump stops will
run back when the pump
stops.
shower should be run
The
for a couple of minutes
after use
to ensure that
the
residual water is
clean.
Note 1: *Water supply presssures may be affected by simultaneous use of
water at another point in the house, a fault in the house plumbing or a
problem with the water supply to the house.
For further assistance please telephone your nearest Chiltern Invadex
Regional Office. Remember that the service calls made after the expiry of
the guarantee will be chargeable. If maintenance of the equipment is the
responsibility of a third party, for example the Social Services, please
contact them in the first instance.
15
User Guide
5
FUSE315mA
FUSE2 amp
N
EARTH
L
SUPPLY
L
EARTH
N
LOAD
L N
AUX
Electrical supply
WARNING! GENERALADVICE FOR INSTALLERS
All installations must comply with I.E.E. regulations, Local Authoritybylaws and electricity board regulations and must be carried out only bya qualified electrician.Follow manufacturers instructions for installation of the shower heaterunit for all electrical units.
SUGGESTED WIRING METHOD
Run a suitable cable (6-10mm sqr for electric showers depending on powerrating and supply distance) from the consumer box via 30mA RCD to theDouble pole ceiling pull switch in the wiring block supplied. (This switch isused to isolate the shower as well as turning the shower waste pump onand off and must be accessible to a wheelchair user where applicable).
The wiring block is positioned at a maximum of 4m from the pump unit andcomplies
with all mentioned regulations. Follow connection instructions
included with wiring block to complete electrical supply.
Shower & pumped waste
The correct wiring installation for the electric shower and pumped wasteis shown in Fig 2. Please pay particular attention to the wire sizes.
Electrical Installation
*Note: For mixer showers load output cable is not required.
Blue
Red
230v ACsupplyfeed incable 6-10mm
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
Black
(Neutral)
Yellow/Green
(Earth)
Red
(Live)
*230v AC loadoutput cable toelectric shower6-10mm
3 core flex(supplied) towaste pumplow voltage
Auxiliary outputfor eg. 230v fanvia 2 amp fuse
Green
Fig 2
12v DC
Chiltern Invadex Side Entry MK2
Operation guide
If a seat is fitted
Fold down the seat, ensuring the feet are firmly placed on the shower
tray, then transfer to the seat.
All cubicles
Pull the mains cord to provide power to the pump/shower.
Operate the shower noting the hot and cold position.
To minimise spray always ensure the shower curtain is closed.
Cross Infection
Warning: If this unit is to be ustilised by many different bathers, then we
would strongly recommend that this unit be cleaned with a medical
disinfectant. Please contact your local infection control nurse for further
advice.
16
User Guid
e
Accessories
Large horseshoe
445mm
Folding Shower seat
Vinyl seat
445mm
Flat padded
445mm
Large aperture
445mm
Medium horseshoe
445mm
Small horseshoe
445mm
Medium aperture
445mm
Small aperture
17
User Guide
3
Fig 1
The height of the waste stack should be between 508mm and 711mmabove the floor level and fitted to the left hand rear of the proposedshower position (see diagram). This diagram is only one example of aninstallation. The position of the pipework will vary according to individualsituations. NOTE: The lower the waste stack pipe the less water will be
left in the trough once the pump is turned off.
Waste Detail
Waste
508mm-711mm
The 102mm (4”) pipe in Chiltern Invadex Side Entry MK2 ShowerToilets is connected through the side panel. The toilet waste pipemust also be connected when the side panel is fitted.
The position of the pan on the base unit must relate to the individualrequirements of the user and we recommend that this operation is leftuntil later. Flush pipe and multikwik pan connector are supplied forstandard installation. These can be extended on site. Additional partsare not included.
Side Elevation
297
170
110mm soil pipeconnection
232
40mm connectionto flexible pipe fromflush tank
minimum clearancefrom wall
Front Elevation
Fitting Instructions for Side Entry MK2 Shower Toilet
Your Chiltern Invadex Shower Cubicle carries a 12 month warranty from
the date of purchase (for guarantee on shower unit see manufacturers
details), subject to the following:-
1. Should you experience any problems with our workmanship or
materials within the first 12 months period, please contact your point
of purchase.
2. Repairs made during the warranty period will be carried out free of
charge, provided the product has been used strictly in accordance
with the guidelines set out in this user guide.
3. Our warranty does not cover replacements, adjustments or repairs
which may be required as result of normal wear and tear, wilful or
accidental damage, misuse, neglect or any other cause which is
beyond the control of Chiltern Invadex.
4. Modifications and repairs made to this product by unauthorised
persons will render the warranty void.
5. Only parts manufactured or approved by Chiltern Invadex shall be
used to repair this product. Use of unauthorised parts will invalidate
all warranties and remove all liability from Chiltern Invadex for the
safety of this product.
6. Chiltern Invadex shall in no event be liable for any damages, costs or
expenses arising from any claim made under this warranty (save fo
any legal liability of Chiltern Invadex for death or personal injury
resulting from the company’s negligence in respect of its products).
7. Faults due to inadequate cleaning, limescale or other water impurities
including debris not flushed from the supply pipe work prior to
connection are excluded from this warranty.
8. This warranty does not affect your statutory consumer rights
20
Please fill in the information below for future reference
reproduced in anyway whatsoever without the express permission in writing of Chiltern Invadex (UK) Ltd.
Published by: Chiltern Invadex (UK) Ltd 126 Churchill Road, Bicester, Oxfordshire OX26 4XD Registered in England No: 04704248
Shower Cubicle
WEEE producer number
WEE/JD1274RU
The crossed wheelie bin symbol shown on the pumped waste option of
this product indicates that the item must not be disposed of with general
household waste. Proper recovery of your waste electronic and
electrical equipment will ensure safety of human health and the
environment.
For more information where the product can be safely disposed of
please contact your Local Authority, the dealer from where the product
was purchased or Chiltern Invadex (UK) Limited.
CINV 86.05 November 2010
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.