80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Input Voltage
Input Current
Input Frequency
Rated Output Power
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 8.93%, 50% Load)
I
PF
RMS
A
0.77 0.97 16.53% 10% 85.51 11.7/0 3.4/1.5 5.1/1.3 5.1/0.2 70.16
1.43 0.98 13.14% 20% 161.69 11.7/0.1 3.4/3.1 5.1/2.5 5.1/0.4 139.92
3.48 0.99 8.93% 50% 396.70 11.8/0.1 3.4/7.7 5.1/6.3 5/1.1 349.04
7.17 0.99 6.48% 100% 819.40 11.9/0.3 3.3/15.4 5/12.6 5/2.2 693.33
900.00
800.00
700.00
600.00
500.00
400.00
300.00
Power (Watts)
200.00
100.00
20% 50% 100%
3656
CHIEFTEC
TPS-700S
NA
2013
ATX12V
7/25/13
I
(%)
THD
Input and Output Power
Input Watts
Loading (% of Rated Output Power)
Load
(%)
Input
Watts
Output Watts
100-240 Volts
10 Amps
47-63 Hz
700 Watts
12V (cumulative of 12V1, 12V2, etc.)
87.99%
86.38%
YES
Input Current and Voltage Waveforms
200
150
100
50
0
0 0.003 0.006 0.009 0.012 0.015
-50
Voltage (V)
-100
-150
-200
DC Terminal Voltage (V)/ DC Load Current (A)
11.9/4.8
11.9/9.5
11.9/23.8
11.9/47.5
100%
90%
80%
70%
60%
50%
40%
Efficiency (%)
30%
20%
10%
0% 25% 50% 75% 100% 125%
Loading (% of Rated Output Power)
Time (s)
Voltage Current
Efficiency of the Power Supply
Output
Watts
Efficiency %
Efficiency
6
4
2
0
-2
-4
-6
%
82.05%
86.54%
87.99%
84.61%
Current (A)
These tests were conducted by a third party independent testing firm on
behalf of the 80 PLUS Program. 80 PLUS is a certification program to
promote highly-efficient power supplies (greater than 80% efficiency in the