80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Input Voltage
Input Current
Input Frequency
Rated Output Power
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 9.38%, 50% Load)
I
PF
RMS
A
0.69 0.97 21.03% 10% 76.58 11.6/0 3.4/1.4 5.1/1.2 5.1/0.2 60.18
1.25 0.98 14.70% 20% 141.46 11.6/0.1 3.4/2.8 5.1/2.3 5.1/0.4 119.87
3.02 0.99 9.38% 50% 344.90 11.6/0.1 3.4/6.9 5.1/5.8 5/1.1 299.77
6.24 1.00 5.54% 100% 714.70 11.7/0.3 3.3/13.8 5/11.7 5/2.2 596.41
800.00
700.00
600.00
500.00
400.00
300.00
Power (Watts)
200.00
100.00
20% 50% 100%
3535
CHIEFTEC
TPS-600S
N/A
2013
ATX12V
4/10/13
I
(%)
THD
Load
(%)
Input
Watts
Input and Output Power
Input Watts
Output Watts
Loading (% of Rated Output Power)
100-240 Volts
9 Amps
47-63 Hz
600 Watts
12V (cumulative of 12V1, 12V2, etc.)
86.91%
85.03%
YES
Input Current and Voltage Waveforms
200
150
100
50
0
0 0.003 0.006 0.009 0.012 0.015
-50
Voltage (V)
-100
-150
-200
DC Terminal Voltage (V)/ DC Load Current (A)
11.9/4
11.9/8
11.9/20.2
11.9/40.2
100%
90%
80%
70%
60%
50%
40%
Efficiency (%)
30%
20%
10%
0% 25% 50% 75% 100% 125%
Loading (% of Rated Output Power)
Time (s)
Voltage Current
Efficiency of the Power Supply
Output
Watts
Efficiency %
Efficiency
5
4
3
2
1
0
-1
-2
-3
-4
-5
%
78.59%
84.74%
86.91%
83.45%
Current (A)
These tests were conducted by a third party independent testing firm on
behalf of the 80 PLUS Program. 80 PLUS is a certification program to
promote highly-efficient power supplies (greater than 80% efficiency in the
active mode) in technology applications. http://www.80plus.org/